Tender For Supply Ofmaterial, Design, Erection, Testing, Commissioningfor Providing Sop To Command And Control Centre Building Uesd No. I Dharamshala Under Ed Dharamshahala. ( Seop-69 / 2023-24 ) .-11 / 0.4Kv, 400 Kva Distribution Transformer 2 Prov. Distribution Transformer 11 / 0.4 Kv, 400Kva Cu Wound 3 Prov. St Pole 9 Mtrs. Long 4 Prov. Rcc Muff ( 2000Mm ) With Concrete Filling 5 Prov. X-Arm ( Channel Iron ( 100X50x6 Mm ) Length: 2800Mm X2 Nos. ) For Incomer Line 6 Prov.Ms Angle Iron ( 50X50x6 Mm ) , Length : 2800Mm X 1Nos For La’S 7 Prov. X-Arm { Channel Iron ( 75X40x6mm ) Length : ( 2800Mmx 4 Nos. ) For Supporting Do Fuse Unit 7 Go Switch. 8 Transformer Belting & Knee Bracing 9 Prov. X –Arm ( Channel Iron ( 100X50x6mm ) Length : 2800Mm X 2 Nos. ) For Transformer Bed 10 X-Arm ( Channel Iron ( 100X50x6mm Length 460Mm X 2 Nos. For Supporting Main Channel Of Transformer ) 11 Ms Angle Iron ( 50X50x6 Mm Length 2800 Mm X 2 Nos. 12 Ms Angle Iron ( 35X35x5 Mm ) Length 460X 2 Nos. 13 Ms Angle Iron ( 50X50x6mm ) Length 950X 2 Nos. For Bed Knee Bracing 14 Transformer Lt Distribution Box And Go Switch Fixing Assembly 15 Ms Angle Iron ( 50X50x6mm ) Length: 2800Mm X 2 Nos. 16 Ms Angle Iron ( 50X50x6mm ) Length: 450Mm X1 Nos. 17 Go Switch Handle Supporting ( Channel Iron 75X40x6 Mm Length 460 Mm 18 Go Ab Switch Unit ( 11Kv, 400A, 25Ka ) Triple Pole O / D Type 19 D.O. Fuse Unit 20 Surge Arrester 9 Kv Station Class ( Porcelain Type ) 21 Discs Insulator Set ( Comprising 1 Nos. Disc ( Porcelain, Bs, 12Kv, 90Kn ) Including Dead End Clamps Etc. 22 Stay Set Complete 23 Stay Wire ( 7 / 3.15Mm ) ( 7.0Kg Per Stay Set ) 24 Pipe Earthingset 25 Lt Distribution Panel Boxwith Acb And 400Amp 3 Nos O / G With Variable Current Settings 26 Half Clamp ( M.S. Flat 50X 6 Mm ) 27 Full Clamps ( M.S. Flat 50X 6 Mm ) 28 Nuts And Bolts Of Various Size ( Galvanized / Coated ) ( Preferably 16 Mm ? Or More ( With Flat And Spring Washers ) 29 Aluminum Thimble 30 Aluminum Thimble 31 Danger Plate 32 Barbed Wire 33 Lt Cable 3.5Core ( 240Mm2 ) 34 Ht Meter 11Kv , - / 5A 35 Ct Pt Unit 30 / 5A 36 12C Control Cable A / W Gi Pipe & Other Allied Accessories Etc 37 Aluminum Paint 38 Transformer Bed Civil Work 39 Prov. Chain Link Fancing, Amgle Iron , Gate For Transformer Fancing 40 Erection Chargescomplete In All Respect 41 Transportation Charges 42 11 Kv Ht Line On Cable 43 11Kv Cable 3Cx70sqmm ( Xlpe Insulated ) 44 Steel Tubular Poles ( 9 M, Working Load > 200 Kgf / M² ) 45 Muffs With Concerete Filling 46 Stay Set Complete 47 Stay Wire ( 7 / 3.15 Mm ) ( 7.0 Kg Per Stay Set ) & For Messenger Wire 48 Full Clamp For Stay 49 X-Arm ( Horizontal ) - Ms Channel Iron: 100X50x6, Length [ 600 Mm ] 3 In No. 50 X-Arm: [ Channel Iron ( 100X50x6 Mm ) , Length : 2800 Mm X 2 Nos ] For Transformer Bed 51 X-Arm: [ Channel Iron ( 75X40x6 Mm ) , Length : ( 2800 Mm X 4 Nos ] For Supporting Do Fuse Unit & Go Switch 52 Ms Angle Iron ( 50X50x6 Mm ) , Length : ( 2800 Mm ) X 2 Nos 53 Half Clamp For Cross Arm 54 Anchoring Assembly For Ht 55 Suspension Assembly For Ht 56 Facade Hooks For Ht 57 Cable Termination Kit 58 Ht Earthing Set Complete ( Preferbly Coil Earthing ) 59 Go Ab Switch Unit ( 11Kv, 400A, 25 Ka ) Tripple Pole O / D Type 60 D.O Fuse Unit 61 Discs Insulator Sets ( Comprising 1 No. Disc: ^^ ( Porcelain, Bs, 12 Kv, 90 Kn ) Including Dead End Clamps Etc. ) 62 Aluminium Paint. 63 Erection Charges Of Cable Complete In All Respect 64 Erection Charges Poles & Stay Sets Complete In All Respect 65 Transportation Charges 66 11 Kv Ht Line Strengthening Of 11Kv Upstrem Network 67 Aaac 7 / 3.81 Mm 68 St Pole 10 Mtr. Long W / L 200 Kg 69 Rcc Muff Of 2000 Mm Length 70 Run Thro Str ( Delta Formation ) 71 X-Arm: [ Ci ( 100X50x6mm ) , L:1270 Mm I / C Tolerance Of 100 Mm Either Side ) 72 Ai ( 50X50x6 Mm ) , L-750Mm X 2 Nos. 73 Pole Top Bracket ( Msci:100X50x6mm-100Mm ) 74 11 Kv Pin Insulator 75 Dead End Structure 76 Belt Set-Ms Ai:50X50x6 Mm, L-1800 Mmx 2 Nos 77 X-Bracing Set-Ms Ai:50X50x6, L-2125 Mmx 2 Nos 78 X Arm ( Horizontal ) -Ms Ci:100X50x6, L-2340 Mmx 2 Nos.Delta Formation 79 Disc Insulator Set Polymeric Bs, 90Kn ( Cleaves And Tong ) 80 Ht Stay / Guy Arrangement 81 Stay Set Complete In All Respect 82 Stay Wire ( 7 / 3.15 Mm ) 83 Earthing 84 Ht Earthing Set Complete 85 Single Continous Earth Wire ( Gi, 8Swg ) Alongwith 2 Wire Length For Avg One Road Crossing @20 M And Additionl 1% ( Sag & Wastge ) @0.102 Kg / M 86 Eye Hook For Earth Wire 87 Earth Wire Clamp 88 Ms Ci :75X40x6, L-2400 Mm 89 Half Clamp [ On Double Pole Dead End Str:4 Nos, On Run Through Str:02 Nos. ] 90 Full Clamp [ On Double Pole Dead End Str:4 Nos, On Run Through Str:02 Nos. ] 91 Danger Plate 92 Nut & Bolt Of Various Size ( Galvenised / Coated ) With Flat And Spring Washer ) 93 11Kv Rmu Ct, S 100-200 / 1A 94 Barbed Wire 95 Aluminium Paint 96 11 Kv Go Switch 97 D O Fuse Unit 98 Erection Charges Of 11Kv Linecomplete In All Respect 99 Transportation Charges 100 Civil Works 101 Excavating, Supplying And Filling Of Local Earth ( Including Royalty ) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. 102 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:5:10 ( 1 Cement : 5 Coarse Sand ) : 10 Graded Stone Aggregate 40 Mm Nominal Size ) 103 Supplying, Filling, Spreading & Leveling Stone Boulders Of Size Range 5 Cm To 20 Cm, In Recharge Pit, In The Required Thickness, For All Leads & Lifts, All Complete As Per Direction Of Engineer-In-Charge. 104 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 1:2:4 ( 1 Cement : 2 Coarse Sand ) : 4 Graded Stone Aggregate 20 Mm Nominal Size ) 105 Quantities Are Mentioned Above Are Tentative And Actual Quantity Shall Be Worked Out After Check Survey To Be Carried Out By The Successful Tender And Detailed Engineering And Finalization Of Tower Location Chart.Payment Shall Be Made As Per Approved Bill Of Material / Actual Quantities Measured At Site.