| 1 | Taking downcarefully old aluminium/copper point wiring for one light, socket or power etc incl all fitings such as switches sockets, holders, light fittings, fan requlators etc and making good the disturbed surface of wall ceiling complete all as speicified and as directed. |
| 2 | Point wiring complete with 1.5 Sq mm PVC insulated cable with copper conductor 1100 Volts grade, multistranded flame retardant low smoke (FRLS) in existing PVC conduit of 20 mm diaconcealed in walls, roof etc with existing 1.6mm thick MS terminal boxes concealed/surface in wallswith and including 3 mm thick laminated hylam sheet top cover for fixing switches, switch sockets outlets etc including provn of 1.5 Sqmm multistranded copper conductor cablePVC insulated unsheathed as earth continuinity cable for one light point controlled by one switch complete all as specified and as directed. |
| 3 | All as per srl item No 2 here-in-before but for One fan/Exhaust fan point controlled by one switchand regulator |
| 4 | All as per srl item No 2 here-in-before but for One socket outlet 3 pin 5 amps on same board. |
| 5 | All as per srl item No 2 here-in-before but for One socket outlet 3 pin 5 amps on independent board. |
| 6 | All as per srl item No 2 here-in-before but for One bell point controlled by one switch |
| 7 | All as per srl item No. 2 here-in-before but with 4 sq mm cable for one 3 pin 15 amps switch socket outlet on independent board with 4 sq mm cable for earth wire drawn through and including 20mm dia PVC conduit and accessories all as specified and directed |
| 8 | M&L for point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable working voltage 1100 volts grade conforming to IS-694 with multistranded copper conductor flame retardant low smoke (FRLS)in includingPVC rigid non metallic 25 mm PVC casing caping (double Lock) including PVC polycarbonate / PVC / rectangular block / box of suitable size fixed by means of brass machine screw and cap washer including size 1.5sqmm (nominal cross sectional areaPVC insulated unsheathed single core multistranded copper conductor cable as earth continuity conductor connected to main switches / DBs or common earth dolly complete all as specified and directed. |
| 9 | All as per srl item No 8 here-in-before but for one ceiling fan /Exhaust fanpoint, controlled by oneway switches 5/6 Amps complete all as specified and directed. |
| 10 | All as per srl item No 8 here-in-before but for one 3 pin socket outlet point, 5/6 Amps on the independent board complete all as specified and directed. |
| 11 | All as per srl item No 8 here-in-before but for one 3 pin socket outlet point, 5/6Amps on the same board with other switches complete all as specified and directed. |
| 12 | All as per srl item No 8 here-in-before but for one bell/buzzer point controlled by one bell push button on independent board complete all as specified and directed. |
| 13 | All as per item No 8 here-in-before but for point wiring with 4 Sq mm (nominal cross sectional area) single core stranded copper conductor for one switch socket out let point, 15/16 ampson the independent board complete all as specified and directed. |
| 14 | Fixing only old serviceable tube light fittings of any type complete all as specified and as directed. Note :- Old serviceable light fittings shall be obtained from taking down of ser item No 1 here-in-before. |
| 15 | S&F Lamp holder, insulated body, with back plate suitable for batten fittings/pendent fittings white/ivory finish complete all as specified and as directed. |
| 16 | S&F Switch piano flush button, white/ivory finish, 5/6 amps, single pole, one way complete all as specified and as directed. |
| 17 | Fixing only Switch piano flush button, white/ivory finish, 5/6 amps, single pole, one way complete all as specified and as directed. Note:-Old serviceable switch shall be obtained from taking down of ser item No 1 here-in-before. |
| 18 | S&F Bell/buzzer push 5/6 amps, flush type, white/ivory finish complete all as specified and as directed. |
| 19 | S&F Ding dong bell, AC, Single pole, 220/240 Volts, white/ivory finish, surface type complete all as specified and as directed. |
| 20 | S&F Switch socket combination, 2 and 3 Pin, 5/6 amps, multipurpose, flush, non shutter, non inter locking type white/ ivory finish complete all as specified and as directed. |
| 21 | S&F Switch socket combination, 2 in 1, 6 pin, 5/6 amps and 15/16 amps multipurpose, white/ivory finish, flush non shutter non inter locking type complete all as specified and as directed. |
| 22 | M&L switch modular 1 way 6 amps 1 module complete all as specified and directed. |
| 23 | M&L switch modular 1 way 16 amps 1 module complete all as specified and directed. |
| 24 | M&L switch modular 2 way 6 amps 1 module complete all as specified and directed. |
| 25 | M&L bell push modular 1 way 6 amps 1 module complete all as specified and directed. |
| 26 | M&L Socket 6 amps modular 2/3 pin 2 module complete all as specified and directed. |
| 27 | M&L Socket 16 amps modular 2/3 pin 2 module complete all as specified and directed. |
| 28 | M&L fan step regulator modular 120 watt 2 module complete all as specified and directed. |
| 29 | M&L modular white cover with frame 1 module complete all as specified and directed. |
| 30 | M&L modular white cover with frame 3 module complete all as specified and directed. |
| 31 | M&L modular white cover with frame 4 module complete all as specified and directed. |
| 32 | M&L modular white cover with frame 6 module complete all as specified and directed. |
| 33 | M&L modular white cover with frame 8 module complete all as specified and directed. |
| 34 | M&L modular metal flush box 1/2 module complete all as specified and directed. |
| 35 | M&L modular metal flush box 3 module complete all as specified and directed. |
| 36 | M&L modular metal flush box 4 module complete all as specified and directed. |
| 37 | M&L modular metal flush box 6 module complete all as specified and directed. |
| 38 | M&L modular metal flush box 8 module complete all as specified and directed. |
| 39 | S&F Sheet metal enclosure for 2 way Distribution Boards (DB’s), single door, single pole & neutral with 100 amps rated bus bar, IP-20 protection suitable for fixing MCB\"S / lsolators after and including taking down old DBwith MCB complete all as specified and directed.Note for Item Ser No 22 to 27:- (i) The rate quoted by the contractor shall include the rate for dismantling and taking out old DBs including disconnecting electrically and reconnecting electrically.(ii) The rate quoted by the contractor shall inculde the rate for making good the disturbed surface by applying white cement to match with existing surface. |
| 40 | S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-43 protection suitable for fixing MCB\"S/lsolators after and including taking down old DBwith MCB complete all as specified and directed. Make : Legrand cat No 507610 or equivalent & approved model of SIEMENS/ ABB make. |
| 41 | S&F Sheet metal enclosure for8 way Distribution Boards (DB’s), double door, single pole and neutral with 200 amps rated bus bar, IP-43 protection suitable for fixing MCB\"S/lsolators after and including taking down old DBwith MCB complete all as specified and as directed.Make : Legrand cat No 507611 or equivalent & approved model of SIEMENS/ ABB make. |
| 42 | S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), doubledoor, Triple pole & neutral with 200 amps rated bus bar, IP-43 protectionsuitable for fixing MCB\"S / lsolator’s after and including taking down old DBwith MCB complete all as specified and directed. Make : Legrand cat No 507670 or equivalent & approved model of SIEMENS/ ABB make. |
| 43 | S&F Sheet metal enclosure for TPN DBs VTPN 4 way Distribution Boards (DB’s), doubledoor, Tripple pole & neutral with 250 amps rated bus bar, IP-43 -IK 09 protectionsuitable for fixing MCB\"S / lsolator’s after and including taking down old DBwith MCB complete all as specified and directed. Make : Legrand cat No 507745 or equivalent & approved model of SIEMENS/ ABB make. |
| 44 | S&F Sheet metal enclosure for TPN DBs VTPN 8 way Distribution Boards (DB’s), doubledoor, Tripple pole & neutral with 250 amps rated bus bar, IP-43 - IP 09 protectionsuitable for fixing MCB\"S / lsolator’s after and including taking down old DBwith MCB complete all as specified and directed. Make : Legrand cat No 507747 or equivalent & approved model of SIEMENS/ ABB make. |
| 45 | S&F Ceiling rose, surface Bakelite, large type, 220/240 volts, three terminals, white/ivory finishcomplete all as specified and directed. |
| 46 | Supply and fixing fan regulator electronic type suitable for 300 Watt (heavy duty) type 250 V, AC forceiling fan complete all as specified and directed. |
| 47 | Dismantling and taking out ceiling fan 230 volts 1200/1400mm sweep any make cutting the old burnt winding rewinding with new super enamelled copper wire as existing guage including insertion of insulating papers threading and insulating with insulating warnish, lathe work, replacement of 2.25/3.15 MFD capacitor, replacement of MS split clamp 02 nos with rubber reeland painting after completion of rewinding process complete all as specified and as directed. |
| 48 | Dismantling and taking out carefully ceiling fan of any size and capacity supply and fixing in replacement of ball bearing of size 6200 to 6204 suitable for ceiling fan 1200/1400mm sweep without disturbing to winding complete all as specified and as directed. |
| 49 | Dimantling and taking out Exhaust fan 230 volts 200 to 450mm sweep any make cutting the old burnt winding rewinding with new super enamelled copper wire as existing guage including insertion of insulating papers threading and insulating with insulating warnish, lathe work, replacement of capacitor, replacement of gun metal bushes and painting after completion of rewinding process complete all as specified and as directed. |
| 50 | Supply and fixing in replacement heating element any size, shape of capacity 1.5/2 KW 230 volt AC supply for electric storage type water heater complete all as specified and directed. |
| 51 | Supply and fix in replacement inner MS water storage tank suitable for 15 ltr storage type water heater complete all as specified and as directed. |
| 52 | All as per srl item No 51 but capacity 25 ltr complete all as specified and as directed. |
| 53 | All as per srl item No 51 but capacity 50 ltr complete all as specified and as directed. |
| 54 | Supply and fix in replacement Thermostat of capacity suitable for 1.5/2 KW 230 volt AC supply for electric storage type water heaters any size/shape complete all as specified and as directed. |
| 55 | Supply and fixing in replacement inlet & outlet assembly any size / shape / Nos of holes suitable for 15 to 50 ltr electric storage type water heaters complete all as specified and as directed. |
| 56 | Supply and fix in replacement fan capacitor 3.15 MFD complete all as specified and as directed. |
| 57 | Supply and fix in replacement electronic driver suitable for LED ceiling lights 36/18 watt complete all as specified and as directed. |
| 58 | M&L for sub main wiring with 2 run of 4 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core flame retardant low smoke cable (FRLS) of working voltage 1100 volts gradewith stranded copper conductorincludingone run of 2.5 Sqmm (nominal cross sectional area) PVC insulated unsheathed flame retardant cable (FR) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly drawn with existing 20 mm diaPVC rigid non- metallic conduit after and including taking down / dismantling old sub main wiring including old conduit / casing capping / wooden batten etc of any description complete all as specified and as directed. |
| 59 | M&L for sub main wiring with 2 run of 6 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core flame retardant low smoke cable (FRLS) of working voltage 1100 volts gradewith stranded copper conductorincludingone run of 4 Sqmm (nominal cross sectional area) PVC insulated unsheathed flame retardant cable (FR) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly drawn with existing 20 mm diaPVC rigid non- metallic conduit after and including taking down / dismantling old sub main wiring including old conduit / casing capping / wooden batten etc of any description complete all as specified and as directed. |
| 60 | Supply and fixing in replacement of LED PRIDE ESSENTIAL wall mounted LED light 20 Watt LED, 6500K with decorative ultra slim square profile LED lighting fixture with extruded polycorbonate environmental friendly energy efficiant complete all as specified and directed. Make as per Havells Cat Part.No: LHEXAWP7IN1W020 or Equivalent in Philips & CG. |
| 61 | Supply and fixing in replacement of E LITE LED PRIDE PLUS NEO wall mounted LED light 10 Watt LED, 6500K with decorative ultra slim square profile LED lighting fixture with extruded polycorbonate environmental friendly energy efficiant complete all as specified and directed.Make as per Havells Cat Part.No: LHEXACP7IN1W010 or Equivalent in Philips & CG. |
| 62 | Supply and fixing in replacement OCTANE LED 2X2 PANEL 36 Watt LED ceiling light fitting suitable for arm strong /grid ceiling with electronic driver complete with all accessories internally pre-wired and including connecting up with twin core copper conductor cable with suitable size complete. Make:-Havells Cat Part No. LHEBAEP5PV1W036 or equivalent in CG/Philips. |
| 63 | Supply and fixing in replacement OCTANE LED PANEL SQUARE 1 x 1, 15 Watt LEDceiling light fitting suitable for arm strong /grid ceiling withelectronic driver complete with all accessories internally pre-wired and including connecting up with twin core copper conductor cable with suitable size complete. Make:-Havells Cat Part LHEBHEP7IZ1W015 or equivalent in CG/Philips. |
| 64 | Supplying and fixing in replacementof HEXA 10W IP66 environmental friendly, ultra modren energy saving surface mounted decorative hexagonal bulk head back lit LED luminaire comprising of high briteness LEDs and making necessary connections complete all as specified and as directed.Make Havells Cat Part. No HEXAFT10WLED857SSYMBOPC or Equivalent in Philips & CG. |
| 65 | Supply and fix in replacement FLORETINE WL 2 LS B22 SS decorative wall mounting brushed nickel finish fixture with opal glass diffucer suitable with 9 watt LED lamp B22 base , complete all as per Havells cat part No : LHFOAJE2TZ1060 or equivalent in CG/Philips |
| 66 | Supply and fix in replacement TRIM PLUS LED PANEL ROUND aesthetically designed recesses mounted panel in a light weight plastic body of capacity 15 watt 6000K suitable for ceiling cutout 145mm dia and height 37mm complete all as per Havells cat part No LHEBFCP7IZ1W015 or equivalent in CG/Philips. |
| 67 | S&F MCB, Tripple pole & neutral, 63 amps, 415 volts, ‘C’ curve, 10 KA complete all as specified and asdirected (Make : Legrand Cat No 408683 or equivalent & approved model of SIEMENS/ ABB make). |
| 68 | S&F MCB, Single pole & neutral, 6 to 32 amps, 240 volts, ‘C’ curve, 10KAcomplete all as specified and as directed (Make : LegrandCat No 408609 to 408617 or equivalent & approved model of SIEMENS/ ABB make). |
| 69 | S&F MCB, Single pole & neutral, 40 to 63 amps, 240 volts, ‘C’ curve, 10KAcomplete all as specified and as directed (Make : LegrandCat No 408618 to 408620 or equivalent & approved model of SIEMENS/ ABB make). |
| 70 | S&F MCB, Single pole, 6 to32 amps, 240 volts, ‘C’ curve, 10 KAcomplete all as specified and as directed (Make :Legrand Cat No 408587 to 408595 or equivalent & approved model of SIEMENS/ ABB make). |
| 71 | Supply and fix in replacement MCCB 160 amps 4 pole 16 KA model DPX3 160 suitable for VTPN DBs complete all as per Legrand cat part No 420007 or equivalent in ABB or L&T. |
| 72 | Supply and fix in replacement MCCB 100 amps 4 pole 16 KA model DPX3 160 suitable for VTPN DBs complete all as per Legrand cat part No 420007 or equivalent in ABB or L&T. |
| 73 | Supply and fixing in replacement LED bldg security light/street light 20 watt 6500K with best in class design and rebust heat sink along with class leading IP,IK and surge protections for long lasting performance complete all as per Havells cat part No LHEXAYP7PN6K020 or equivalent in Philips or CG. |
| 74 | Labour only for taking out of any DB of any make for attending NO light /Earth leakage complaintsfrom technical area and disconnecting the wires/cables from terminal blocks and connection to feeder and cutting/removing the damaged worn out conductor/wires portion and reconnecting the cable to terminal box after servicing and making serviceable condition testing complete all as specified and as directed.Note:material used for serviceable condition will be measured seperately. |
| 75 | Note For Day to Day maintenance:- (i) The contractor will be alloted complaint on daily basis and sufficient resources will be deployed by him/her for completion of day to day complaint within 24 hrs from the time of reporting.Any delay beyond above mentioned time limit penalty at the rate of Rs.50 per complaint per day as mentioned in relevant clause of contract. (ii) A detailed log of complaints with completion/non completion remarks from users & MES will be maintained by the contractor and same will be updated on daily basis in consultation with Engineer In Charge or JE detailed by him duly signed. (iii) The contractor will make suitable arrangement for emergent complaints and will notify auth rep/Engr In Charge about extraordinary circumstances for probable non completion or delay in rectification of complaits beyond state time limit set for disposal complaint in case of any dispute the decision of accepting officer willl be final and binding in this regard. (iv) The quoted rate deemed to be incluisive of transportation and other expenses required for the resorce deployment at the complaint site around at Airforce station thanjavur. (v) The contractor will maintain suitable inventories and range of spares required to meet the complaints as same will be reviewed periodically by Engineer In Charge to streamline complaints disposal system (vi) No light/earth leakage complaints has to be attended immediately and feed back to be get from user and intimation to Engineer In Charge or JE detailed by him duly signed. |