Supply, Installation, Testing And Commissioning Of 2 X 6 Tr Dx Type Precession Air Conditioning System Including Necessary Associated Works Like Refrigerant Piping, Ducting, Etc. , Sitc Of 2*6Tr Dx Type Precession Air Conditioning System Including Necessary Associated Works Like Refrigerant Piping, Ducting, False Celling And Under Deck Thermal Insulation As Per The Boq Enclosed. , Supply, Installation, Testing & Commissioning Of Floor Mounted, Top Discharge With Liquid Receiver High Sensible Dx Type Precision Air Conditioning Unit With Air Cooled Condenser , Supply & Laying Ofsuitable Sized Duly Insulated Hard Drawn Copper Piping For Interconnection Between Indoor & Outdoor Unit, For Both The Hot Gas And Liquid Line. , Supply Of Suitable Size And Core Of 1.1 Kv Grade, Xple Insulated, Pvc Sheathed Armoured Ug Cable , Laying, Termination Using Brass Cable Gland And Lugs, Making Connections Suitably With Copper Conductor Armoured Cable Between Indoor & Outdoor Unit As Required. , Supply Of Suitable Size And Core Of 1.1 Kv Grade, Xple Insulated, Pvc Sheathed Armoured Ug Cable , Laying, Termination Using Brass Cable Gland And Lugs, Making Connections Suitably With Copper Conductor Armoured Cable For Connectivity Between Electrical Mains And Pac Unit Available Within Around 5 Mtr. Of Vicinity As Required , Supply And Installation Of Gi Cable Tray Along With Cover Of Suitable Size Using Necessary Clamps & Hard Wares As Required For Laying Copper Refrigerant Lines And Cables Between Indoor& Outdoor Units. , Sitc Of Suitable Sized Motorised Damper With Actuator On Supply Side Of Pac Unit Including Necessary Wiring From The Existing Fire Alarm Control Panel Within The Building As Required , Supply , Fabrication, Erection Of Gi Rectangular Ducting With 24G With Suitable Box Section Ducts With Tdf Flanges And Connectors Comprising Of Gi Threaded Rods Along With Fastener, Washer And Clamps, Corners, Cleats, Nut & Bolts, Gasket, Silicon Sealant Complete With Necessary Supports With Necessary Plenum , Supply And Installation Of Extruded Aluminiumpowder Coated Supply Air Diffusers With Square Ceiling Plaque Diffuser, Moulded Outer Frame And Removable Plaque Core With Plain Flush Type Frame With Collar Damper With Gss Plenum Boxes For Fixing The Diffusers Along With Suitable Openings For Outer To Outer Size Of 600X600mm , Supply And Installation Of Extruded Aluminiumpowder Coated Return Air Diffusers With Square Ceiling Plaque Diffuser, Moulded Outer Frame And Removable Plaque Core With Plain Flush Type Frame Without Collar Damper Along With Suitable Openings For Outer To Outer Size Of 600X600mm , Supply And Installation Of Extruded Aluminiumpowder Coated Return Air Linear Continuous Grills Without Collar Damper For Fixingabove Pac Location , Supply And Installation Of 19Mm Thickduct Insulation Made Out Of Closed Cell Chemically Cross Linked Polyethylene Foam ( Xlpe ) Laminated With Aluminium Foil On One Side And Class 0 Rating For Supply Air Ducts With Necessary Adhesives And Accessories. , Supply And Making Ofacoustic Insulation Of 19 Mm Thick With 24 Kg / M3 Density For The Plenum With All The Necessary Materials And Hardware , Supply And Installation Of Canvas Connection Along With A Openable Zip For Pac Units As Required. , Supply And Installation Of Suitable Sized Insulated Flexible Duct To Match For The With Aluminium Jacket And Of Glass Wool Insulation For Connection Between Main Supply Duct And Collar Including Universal Clamp And Gi Clamp For Centre Support For Diffuser Connections. , Supply & Installation Of Condensate Drain Piping With Suitable Size Of Upvc Piping With Necessary Insulation , Supply & Installation Of Humidifier Water Piping With Upvc Of Size 25Mm Dia With Accessories Along With Ball Valve Where Ever Necessary. , Supply, Installation, Testing And Commissioning Of Continuous Duty Cycle, Twin Condensate Pump Of Suitable Capacity, And Head As Required. , Supply And Making Under Deck Insulation For Bottom Of Roof Slab Insidethepac Area With 6 Mm Thickness Nitrile Rubber Using Necessary Adhesives And Fixing Accessories , Providing And Fixing Tiled False Ceiling Of Acoustical Suspended Ceiling System With Fine Fissured Tiles Having Board Edges Of M / S Armstrong Or Equivalent With Following Specifications ( A ) The Tiles Shall Have Humidity Resistance Of 99% Rh, Nrc 0.55, Light Reflectance>80%, Thermal Conductivity K=0.052-0.057 W / Moc, Colour White, Fire Performance Class O / Class 1 ( Bs-476 ) With Life Time Warrantee Against Sag In Module Size Of 600Mmx600mmx16mm Laid On 24Xll-Hot Dipped Galvanised Steel Suspension System Having Rotary Stitching On The Main Runner, 1200Mm And 600Mm Cross Tees. , Supply And Fixing Of Exterior Type Sun Control Film For The Existing Window Glasses Of Pac Room. Interior / Exterior , Dismantling, Shiftingof Existing Led Light Fittings - 24 Nos. And Re-Installing Using Necessary Gi Chain And Anchor Fasteners, Making Connections From Existing Point Using1 Sq.Mm X 3 Core Copper Flexible Cable , Dismantling Of Smoke Detectors / Response Indicators - 5 Nos. From Theexisting Ceiling, Shifting, And Re-Installation Using Necessary Cables As Required. , Sub-Total: , Less: Discount ( If Any ) , Grand Total