}

Bids Are Invited For 1.01 Rewiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq.Mm Frls Pvc Insulated Copper Single Core Cable And 1.5 Sq.Mm Frls Pvc I, Meerut-Uttar Pradesh

Government Departments has published Bids Are Invited For 1.01 Rewiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq.Mm Frls Pvc Insulated Copper Single Core Cable And 1.5 Sq.Mm Frls Pvc I. Submission Date for this Tender is 29-04-2024. Electrification Work Tenders in Meerut Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43199619
Bids Are Invited For 1.01 Rewiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq.Mm Frls Pvc Insulated Copper Single Core Cable And 1.5 Sq.Mm Frls Pvc I
Open Tender
Indian
Uttar Pradesh
Meerut
29-04-2024

Tender Details

Bids Are Invited For 1.01 Rewiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq.Mm Frls Pvc Insulated Copper Single Core Cable And 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable As Earth Wire In Existing Surface / Recessed Steel / Pvc Conduit Including Dismantling As Required ( For Type Ii& Type Iii Qtrs. ) Group -A 2 Rewiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq.Mm Frls Pvc Insulated Copper Single Core Cable And 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable As Earth Wire In Existing Surface / Recessed Steel / Pvc Conduit Including Dismantling As Required ( For Type Iv Qtrs. ) Group -B 2.99 Rewiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable As Earth Wire In Existing Surface / Recessed Steel / Pvc Conduit Including Dismantling As Required. 3.98 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. ( A ) 3 X 1.5 Sq. Mm 4.97 6 X 1.5 Sq. Mm 5.96 3 X 2.5 Sq. Mm 6.95 6 X 2.5 Sq. Mm 7.94 3 X 4 Sq. Mm 8.93 6 X 4 Sq. Mm 9.92 Supplying And Fixing Of Following Sizes Of Steel Conduit Along With Accessories In Surface / Recess Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. ( A ) 20 Mm 10.91 ( B ) 25 Mm 11.9 Supplying And Fixing Metal Box Of Following Sizes ( Nominal Size ) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Painting Etc. As Required ( A ) 100 Mm X 100 Mm X 60 Mm Deep 12.89 ( B ) 180 Mm X 100 Mm X 60 Mm Deep 13.88 ( C ) 200 Mm X 250 Mm X 60 Mm Deep 14.87 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box / Cover Including Connections Etc. As Required. ( A ) 5 / 6 Amps Switch 15.86 2 Way 5 / 6 A Switch 16.85 15 / 16 A Switch 17.84 3 Pin 5 / 6 A Socket Outlet 18.83 6 Pin 15 / 16 A Socket Outlet 19.82 Bell Push 20.81 Supplying And Fixing 3 Pin, 5 A Ceiling Rose On The Existing Junction Box / Wooden Block Including Connections Etc. As Required. 21.8 Supplying And Fixing Brass Batten / Angle Holder Including Connection Etc. As Required. 22.79 Supplying And Fixing Call Bell / Buzzer Suitable For Single Phase, 230 V, Complete As Required 23.78 Supplying And Fixing 12 Way , Double Door, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 24.77 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. ( A ) Single Pole 25.76 Supplying And Fixing 40 Amp, Double Pole, 240 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 26.75 Supplying And Fixing Cable End Box ( Loose Wire Box ) Suitable For Following Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface / Recess, Complete With Testing And Commissioning Etc. As Required. ( A ) For 10 Way, Double Door Spn Mcbdb 27.74 Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal / Coke And Salt As Required 28.73 Supplying And Laying 6 Swg G.I. Wire At 0.50 Metre Below Ground Level For Conductor Earth Electrode, Including Connection / Termination With Gi Thimble Etc. As Required 29.72 Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required. 30.71 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 31.7 Supplying And Fixing Of Fancy Wall Bracket Suitable For 1X13 Watt Led / Cfl Luminaries For Operation On 230 Volt 50 Hz. Ac Supply Complete With All Accessories I / C 9 Watt Led / Cfl Lamp Including Connections Etc.Complete As Required.Make-Havells / Philips / Decon Or S / S Make ) 32.69 Suppling , Installation, Testing And Commissioning Of 1200 Mm. Ceiling Fan, Including Wiring The Down Rods Of Standard Length ( Upto 30 Cm ) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required. ( Cromption / Havells / Usha / Orient Or Other Isi Marked ) 33.68 Supplyinf & Fixing Of 18 Watt 230Volt Led Tube Light Fitting Directly On Ceiling / Wall, Including Connections With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. As Required. ( Make Philips, Syska Or Ss Make ) 34.67 Supplying And Laying, Fixing I / C End Termination Of Following Size 1.1 Kv Lt Armoured Cable Of Multicore Aluminium Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Extruded Pvc Type St2 Outer Sheathed, Armoured With Galvanised Steel Flat Strip, Conforming To Is:7098 ( Part-1 ) / 1988 Etc. As Reqd. ( M / S Finolex, Havells, Polycab Kie Industries Ltd, Rr Kabel, V-Guard Industries Ltd Make ) ( A ) 4X16 Sq.Mm Alumn. Conductor 35.66 2X10 Sq.Mm Alumn. Conductor 36.65 Supply, Installation, Testing And Commissioning Of Cubical Type Floor Mounting Energy Meter Panel Fabricated Out Of 1.6 Mm C.R.C.A. Sheet With Suitable Size Frame, Hinged Type Door, Front & Back Openable, Powder Coating After Treatment Of Crca Sheet, Sign Writing. Suitable For Operation On 415 Volts, 3 Phase, 4 Wire 50 Hz A.C. Supply With Following Incoming & Outgoing Switches / Energy Meters Etc. Complete As Reqiured. ( I ) 200 Amp Alum. Bus Bar 4 Strip Supported On Smc Insulator For 3 Phase And Neutral ( Ii ) Two Nos. Earth Studs With 25 Mm X 5 Mm Copper Bus Bar Across The Panel For The Earth Connection ( Iii ) 5 Mm Thick Bakelite Sheet With Locking Arrangment Of Each Compartment For Mounting Of Energy Meter. Iv ) Panel Mounted On Base Frame Made Of M.S. Channel Of Size 75Mm. X 40 Mm. X 4.8Mm. Thick I / C 15 Cm.Long 6 Legs Etc. Complete As Reqiured. A ) In Commer : ( I ) 125 Amp. Tpn ( Sdf ) With Hrc Fuses- 01 No. Conforms To Is-13947 - Part I & Iii / Iec-947 Part I & Iii, ( Ii ) Leds Type 22.5Mm Dia Indication Lamp With Hrc Fuses / Mcb For ( R-Y-B ) And On-Off– 01 Sets. ( B ) Outgoing ( I ) Lcd Display Ac Single Phase Static Energy Meter Of Accuracy Class 1.0, Rating 5-30A, 240V, 50Hz, Kwh, Kvah Compact Meter With Sealing Screw Provision With Dp Mcb 32 Amp.Connection With 6Mm. Dia Copper Conductor Pvc Insulated Cable- 06 Nos. ( Make For Tpn & Energy Meter, Make- Hpl / L&T Or S / S Make ) ( Note:- Drawing Got Approved From Engineer Incharge Before Fabrication Of Panel ) 37.64 Supply, Installation, Testing And Commissioning Of Cubical Type Floor Mounting Energy Meter Panel Fabricated Out Of 1.6 Mm C.R.C.A. Sheet With Suitable Size Frame, Hinged Type Door, Front & Back Openable, Powder Coating After Treatment Of Crca Sheet, Sign Writing. Suitable For Operation On 415 Volts, 3 Phase, 4 Wire 50 Hz A.C. Supply With Following Incoming & Outgoing Switches / Energy Meters Etc. Complete As Reqiured. ( I ) 200 Amp Alum. Bus Bar 4 Strip Supported On Smc Insulator For 3 Phase And Neutral ( Ii ) Two Nos. Earth Studs With 25 Mm X 5 Mm Copper Bus Bar Across The Panel For The Earth Connection ( Iii ) 5 Mm Thick Bakelite Sheet With Locking Arrangment Of Each Compartment For Mounting Of Energy Meter. Iv ) Panel Mounted On Base Frame Made Of M.S. Channel Of Size 75Mm. X 40 Mm. X 4.8Mm. Thick I / C 15 Cm.Long 6 Legs Etc. Complete As Reqiured. A ) In Commer : ( I ) 125 Amp. Tpn ( Sdf ) With Hrc Fuses- 01 No. Conforms To Is-13947 - Part I & Iii / Iec-947 Part I & Iii, ( Ii ) Leds Type 22.5Mm Dia Indication Lamp With Hrc Fuses / Mcb For ( R-Y-B ) And On-Off– 01 Sets. ( B ) Outgoing ( I ) Lcd Display Ac Single Phase Static Energy Meter Of Accuracy Class 1.0, Rating 5-30A, 240V, 50Hz, Kwh, Kvah Compact Meter With Sealing Screw Provision With Dp Mcb 32 Amp.Connection With 6Mm. Dia Copper Conductor Pvc Insulated Cable- 04 Nos. ( Make For Tpn & Energy Meter, Make- Hpl / L&T Or S / S Make ) ( Note:- Drawing Got Approved From Engineer Incharge Before Fabrication Of Panel ) 38.63 Supply, Installation, Testing And Commissioning Of Out Door Cubical Type Floor Mounting Three Phase Feeder Panel Fabricated Out Of 2.0 Mm C.R.C.A. Sheet With Suitable Size Frame, Hinged Type Door, Front & Back Openable, Powder Coating After Treatment Of Crca Sheet, Sign Writing. Suitable For Operation On 433 Volts, 3 Phase, 4 Wire 50 Hz A.C. Supply With Following Incoming & Outgoing Switches As Per The Specification Attached ( I ) 04 Nos. 300 Amp. Alumn. Bus Bar 4 Strip Supported On Smc Insulator For 3 Phase And Neutral ( Ii ) Two Nos. Earth Studs With 25 Mm X 5 Mm Copper Bus Bar Across The Panel For The Earth Connection ( Iii ) Panel Mounted On Base Frame Made Of M.S. Channel Of Size 75Mm. X 40 Mm. X 4.8Mm. Thick I / C 50 Cm.Long 6 Legs Etc. Complete As Reqiured. ( A ) ( I ) Incommer -250 Amp. Tp&N ( Sdf ) I / C Hrc Fuses- 01 No ( Ii ) Leds Type 22.5Mm Dia Indication Lamp With Hrc Fuses / Mcb For ( R-Y-B ) And On-Off– 01 Sets. ( B ) Outgoing - ( I ) 125 Amp. Tp&N ( Sdf ) I / C Hrc Fuses -04 Nos. ( Ii ) 125 Amp. Alumn. Bus Bar For Inter-Connection Of Out Going Cables. ( Make-For Tpn , Hpl / L&T Or S / S Make ) ( Note:- Drawing Got Approved From Engineer Incharge Before Fabrication Of Panel ) Total Quantity : 2654

Key Value

Document Fees
Refer document
EMD
INR 24089.0 /-
Tender Value
INR 12.04 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail