}

Tender For Cystoscopy Cart (Urology), Mumbai-Maharashtra

Tata Memorial Centre has published Tender For Cystoscopy Cart (Urology). Submission Date for this Tender is 05-06-2024. Surgical Instrument Tenders in Mumbai Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

43197226
Corrigendum : Tender For Cystoscopy Cart (Urology)
Global Tenders
Indian
Maharashtra
Mumbai
05-06-2024

Tender Details

Tender For Cystoscopy Cart ( Urology ) ; Model Name: Make: Year Of Introduction: Year Of Probable End Of Support: 1 Full High Definition ( Hd ) Camera System 1 Pc A. Camera Control Unit 1. Outputs- 1 X Dvi , 2 X Hd Sdi ( 1920*1080 ) 2. Dvi , Hd ( Length 3M ) Should Be Supplied 3.Should Have Inbuilt / External Recording With External Hdd Of 2Tb B. Camera Head 1 Pc 1. Image Sensor Should Be Of 3 X 1 / 3 & Ccd / Cmos With Atleast 2 Head Camera Buttons For Zoom, Focus, White Balance Etc. 2. Image Resolution- 1920 X 1080P 3.Integrated Zoom Lens F = 15-28 Mm Or Better 4. Camera Cable Should Be Atleast 3M Long 2 Led Light Source 1 Pc A. High Performance Led B. Led Lamp Life Should Be 10000Hrs Or Better 3 Fibre Optic Cable 2 Pc A. Should Be Heat Resistant, Have Enhanced Light Transmission B. Diameter 4.8Mm, Length 230Cm C. Should Be Autoclavable & Have Telesope Adaptor & Light Adaptor 4 Medical Grade Monitor 2 Pcs A. Display Technology- Full Hd B. Image Resolution- 1920 X 1080 C. Screen Size- 26Inches Or Better D. Image Aspect Ratio- 16:9 E. Monitor Should Be Compatible With Existing Camera Processor E Vision Pro And Camera Control Unit 1.A 5 Recording Unit 1 Pc 1 Should Be A Modular And Preconfigured System For Intraoperative Documentation Of Still Images And Videos. 2 Should Record Still Images And Videos In Full Hd ( With Resolution 1920 X 1080 ) With No Degradation In Image Quality. 3 Video Recording Format Should Be Mpeg 4 Avc / H.264 4 Still Image Recording Format Should Be Bmp / Tiff / Jpeg 5 Compatible Media Should Be Internal Hdd / Blu-Ray Disks / Dvd / Usb Stick 6 Internal Hdd Capacity Should Be Atleast 1Tb 7 Should Have Structured & Clear User Guidance To Fill Patients Data ( Id, Procedure Name, Sex, Surgeons Name , Etc ) , And Have Access For Functions Like Play, Recording Start-Stop, Pause, Capture. 8 Supported Color System Should Be Pal, Ntsc 9 Should Have An In-Built Display Monitor Or Separate Hd Monitor Should Be Provided Which Allows To Record Or Capture In Real Time 10 Should Have Video Input Signals Such As Dvi, Y / C, Composite 11 Serial Remote- Rs 232C, Stereo Mini Pin Jack 12 Should Have Pacs & Dicom Compatibility 13 It Should Be Stand Alone Recorder. Pc & Software Based Recoder Is Not Acceptable. 6 Trolley With Electrical Point & Multiple Shelves 1 Pc 7 Telescope 4Mm, 30° 3 Pcs A. Should Be Autoclavable, Have Enlarged View B. Diameter Should Be 4Mm, Length 30Cm. C. Fibre Optic Light Transmission Should Be Incorporated D. Should Be Provided With Sterilization Tray For Each Scope 8 Telescope 4Mm, 0° 1 Pc A. Should Be Autoclavable, Have Enlarged View B. Diameter Should Be 4Mm, Length 30Cm C. Fibre Optic Light Transmission Should Be Incorporated D. Should Be Provided With Sterilization Tray For Each Scope 9 Cystoscopy Sheath With Obturator 20Fr ( ±1 Is Acceptable ) 1 Pcs 10 Cystoscopy Sheath With Obturator 17Fr ( ±1 Is Acceptable ) 2 Pcs 11 Cystoscopy Sheath With Obturator 22Fr / 23Fr ( ±1 Is Acceptable ) 1 Pcs 12 Resectoscopy Sheath 26 Fr 3 Pcs A. Should Have Connecting Tubes For In & Outflow B. Should Have Oblique Beak With Standard Obturator C. Rotatable Inner Tube Should Be Provided 13 Working Element Cutting Should Be By Means Of Thumb Grip. The Finger Support Is Not Movable. In Rest Position, The Electrode Is Inside The Sheath 2 Pcs Working Element Set Should Consist Of: A. Cutting Loops 20 Pcs B. Coagulating Electrodes 5 Pcs C. Collins Knife 5 Pcs D. High Frequency Cords 4 Pcs E. Viu Knife 4 Pcs F. Halfround Knife 1 Pc G. Visual Obturator 2 Pc H.Straight Loop Enblock 1 Pc 14 Optical Urethrotomy Sheath With Half Round Sheath 1 Pc A. Obturator Should Be Supplied 15 Optical Biopsy Forceps Rigid- Should Have Double Action Jaw 2 Pc 16 Cystoscopy Flexible Biopsy Forceps 7 Fr ( Oval Spoon ) 2 Pc A. Should Be Flexible, Double Action Jaw, 7 Fr, Length 40Cm 17 Telescope Bridge With 1 Instrument Channel 3 Pcs 18 Telescope Bridge With 2 Instrument Channel 1 Pc 19 Cystoscopy Grasping Forceps 7 Fr- With Alligator Jaw, Length 40Cm, Flexible-2 , Rigid-1 3 Pcs 20 Urovac Bladder Evacuator 4 Pcs 21 Toomey Syringe ( 50Cc ) 2 Pcs 22 Urethral Dilator Set Male & Female 1 Pc 23 Cystoscopy Penile Clamp 5 Pcs 24 Otis Urethrotome 1 Pc 25 Otis Urethrotome Blade 2 Pcs 26 Flexible Blue Dilator Set 1Pcs 27 Bugbee Electrode 3Mm 2 Pcs 28 Bugbee Electrode 5Mm 2 Pcs 29 Should Be Provided With Instrument Box 3 Pcs 30 Flexible Video Cystoscope 1 Pc 1 Should Be High Resolution Reusable Flexible Video Cystoscope 2 Insertion Tube Outer Diameter Should Be 16-17 Fr 3 Field Of View Should Be 100 ° Or More 4 Working Channel Diameter 6-7 Fr Or Better 5 Angulation Range Should Be Approx 200 ° Up & 130 ° Down Or Better 6 Working Length Should Be Around 380Mm 7 Should Be Compatible To Camera Control Unit 1.A. 8 Should Be Provided With Sterilization Tray 31 All The Instruments Should Be Ce / Fda / Bis / Icmed Certified And Of Single Parent Company Except Trolley , Urovac, Toomey Syringe, Urethral Dilator Set, Cystoscopy Penile Clamp, Otis Urethrotome With Blade, Bugbee Elctrode, Instrument Box, Grasping Forcep 7Fr And Biopsy Forcep 7Fr. 32 Should Perform Yearly Calibration / Validation And Preventive Maintenance ( 2Nos ) During Warranty & If Entered Into Amc ( Includes Unlimited Breakdown Calls ) / Cmc ( Which Will Include Spare Replacement, Consumable Spares, Breakdown Calls ) Testing & Measuring Equipment Used Should Be Traceable To Si Units Through National / International Standards ( As Per Nabl / Nabh Norms ) . To Submit Sops For Pms At The Time Of Installation / Commissioning. 33 Please Submit The Technical Data Sheet Along With The Brochure As A Tender Document With Reference To The Quoted Make & Model. 34 Please Specify List Of Consumables / Consumable Spares ( I.E.Spares Need To Be Replaced At Regular Intervals, Maybe Quarterly / Half Yearly / Yearly Such As Annual Maintenance Kit Etc. ) If Any. 35 Please Specify Pre Installation Requirements [ Electrical, Hvac, Compressed Air ( Please Specify Required Air Pressure ) , Water Requirement ( Ro / Di / Distilled Water With Its Pressure, Flow Rate Per Hour ) ; If Any Of The Above Is Essential ] 36 Please Specify Footprint Size & Weight. 37 Demo Of The Quoted Model , Will Be Required If So Desired By The User, After The Opening Of The Technical Bid And Prior To Opening Of Financial Bid. This Is For Technical Evaluation. 38 Predispatch Inspection At Factory Will Be Required If Desired By Authorities. 39 Please Visit The Site To Check Whether Quoted Model Can Be Accomodated In The Available Space. 40 Should Be Ce / Fda / Bis / Icmed Approved 41 Please Specify Power Consumption. 42 Unpacking And Shifting The Consignment To The Installation Site Is To Be Included In The Scope Of Supply. Bidder / Manufacturer / Authorized Service Provider Should Take Responsibility To Lift / Shift The Consignment From Unloading Site To The Installtion Site. Unloading Site Shall Be Stores Department, Main Building Basement, Tmh. If Needed , Bidder Has To Arrange For The Laboures At No Charge To Tmh. ( Before Submitting The Quotation, Bidders May Visist Tmh To Know Unloading And Installtion Site. 43 Local Service Support: Should Have Local Office And Service Support / Service Engineer For Attending The Breakdown Calls. 44 Response Time: Should Not Be More Than 06 Hrs From Lodging A Breakdown Complaint On Toll Free Or By Email. 45 Warranty- 2 Years 46 Cmc- Cost Per Annum Will Be Considered For All Bidders For 8 Years After Warranty. Include 2 Preventive Maintenance / Year And All Breakdown Visits. All Bought Out Items Used In System Should Also Be Included In The Warranty & Cmc. Warranty & Cmc Should Include Upgrades / Update Cost, No Separate Software Licence Fees Will Be Payable. 47 Back To Back Assurance To Be Taken By The Supplier From Oem To Supply Spares For Minimum 10 Years And To Be Submitted. 48 Buyback Offer To Be Given For Existing Cystoscopy Cart Make: Sholly Qty 1 No

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 20-05-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-05-2024
2 21-05-2024 Corrigendum I Date 05-06-2024

Key Value

Document Fees
Refer document
EMD
INR 151900.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail