Tender For Supply Of Powergrid Ss51t-765Kv Gis ( Jamnagar ) --1 Gis Bay: 765Kv, 3150 A, 50 Ka, Sf6 Gis Ict Feeder Baymodule As Per Section-Project, Technical Specification 2 Gis Bay: 765Kv, 3150A, 50Ka, Sf6 Gis Bus Reactor Feeder Baymodule As Per Section-Project, Technical Specification 3 Gis Bay: 765Kv, 3150A , 50Ka, Gis Line Feeder Baymodule ( With Pir ) As Per Section-Project, Technical Specification 4 Gis Bay: 765Kv, 3150A, 50Ka, Sf6 Gis Tie Baymodule ( With Pir ) As Per Section-Project, Technical Specification 5 Gis Bay: 765Kv, 3150A, 50Ka, Sf6 Gis Switchable Line Reactor Feeder Baymodule As Per Section-Project, Technical Specification 6 Gis Bay: 765Kv, 3150A, 50Ka, Sf6 Gis Tie Baymodule ( Without Pir ) As Per Section-Project, Technical Specification 7 Gis: 765Kv, 3150A, 50Ka, Sf6 Gis Auxiliary Busmodule For Spare Transformer As Per Section-Project, Technical Specification 8 Gis: 765Kv, , 3150A, 50Ka, Sf6 Gis Auxiliary Busmodule For Spare Reactor As Per Section-Project, Technical Specification 9 Gis: 765Kv, 4000A, 50Ka, Sf6 Gis Bus Bar Module As Per Section-Project, Technical Specification 10 Gis: 765Kv, 3150A, 50Ka, Single Phase Sf6 To Air Bushing 11 Gis: 765Kv, , 3000 / 3150 A, 50Ka, 1 Phase, Sf6 Gas Insulated Bus Duct ( Gib ) Outside Gis Hall 12 Gis: Controlled Switching Device ( Csd ) For 765 Kv, 3 Phase Circuit Breaker 13 Gis: Local Control Cubicles ( Lcc ) 14 Gis T&M Equipment: Sf6 Gas Filling And Evacuation Plant For 765Kv Gis Station 15 Gis T&M Equipment:Portable Partial Discharge Measurement Test Kitwith All Necessary Accessories, Industrial Grade Laptop And Licensedsoftware As Per Technical Specification. 16 Gis T&M Equipment: Sf6 Gas Analyzer 17 Gis T&M Equipment: Sf6 Gas Leakage Detector 18 Gis T&M Equipment: Portable Scissor Lift 19 Spares: 765Kv Gis- Sf6 Gas Pressure Relief Device Assembly Of Each Type 20 Spares: 765Kv Gis-Sf6 Pressure Gauge Cum Switch / Density Monitors And Pressureswitch As Applicable, Of Each Type 21 Spares: 765Kv Gis- Coupling Device For Pressure Gauge Cum Switch For Connectinggas Handling Plant Of Each Type 22 Spares: 765Kv Gis- Rubber Gaskets, O Rings And Seals For Sf6 Gas For Gisenclosure Of Each Type 23 Spares: 765Kv Gis- Molecular Filter For Sf6 Gas With Filter Bags ( 5% Of Total Weight ) 24 Spares: 765Kv Gis- Control Valves For Sf6 Gas Of Each Type 25 Spares: 765Kv Gis- Sf6 Gas ( 5% Of Total Gas Quantity ) 26 Spares: 765Kv Gis- Locking Device To Keep The Dis-Connectors ( Isolators ) And Earthing / Fast Earthing Switches In Close Or Open Position In Caseof Removal Of The Driving Mechanism 27 Spares: 765Kv Gis- Uhf Pd Sensors Of Each Type Along With Bnc Connector For 765Kv Gis 28 Spares: 765Kv Gis- Support Insulators ( Gas Through ) Of Each Type ( Complete Withmetal Ring Etc. ) Along With Associated Contacts And Shields 29 SPARES: 765KV GIS- GAS BARRIERS OF EACH TYPE(COMPLETE WITH METAL RING ETC.) ALONG WITH ASSOCIATED CONTACTS AND SHIELDS 30 SPARES: 765KV GIS- 3150A SF6 TO AIR BUSHING COMPLETE IN ALL RESPECT 31 SPARES: 765KV GIS- LCC SPARES - AUX. RELAYS,CONTACTORS, PUSH BUTTONS,SWITCHES,LAMPS, ANNUNCIATION WINDOWS,MCB,FUSES, TIMERS,TERMINAL BLOCKS ETC. OF EACHTYPE & RATING 32 SPARES: 765KV GIS- ONE POLE OF 3150A CIRCUIT BREAKER WITHOUT PIR WITHINTERRUPTER,MAIN CIRCUIT,ENCLOSURE AND OPERATING MECHANISM COMPLETEIN ALL RESPECT 33 SPARES: 765KV GIS- ONE POLE OF 3150A CIRCUIT BREAKER WITH PIR WITH INTERRUPTER, MAIN CIRCUIT,ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALL RESPECT 34 SPARES: 765KV GIS- Trip coil assembly with resistor for 765kV GIS Circuit Breaker(As applicable) 35 SPARES: 765KV GIS- Closing coil assembly with resistor for765 kV GIS Circuit Breaker(As applicable) 36 SPARES: 765KV GIS- RELAYS,POWER CONTACTORS,PUSH BUTTONS,TIMERS & MCBS ETC.(AS APPLICABLE)OF EACH TYPE FOR 765KV GIS CIRCUIT BREAKER 37 SPARES: 765KV GIS- Auxiliary switch assembly of each type for 765kV GIS Circuit Breaker 38 SPARES: 765KV GIS- OPERATION COUNTER for 765kV GIS Circuit Breaker 39 SPARES: 765KV GIS- HYDRAULIC OPERATING MECHANISM WITH DRIVEMOTOR(FOR HYDRAULIC OPERATED MECHANISM,IF APPLICABLE) for 765kV GIS Circuit Breaker 40 SPARES: 765KV GIS- HYDRAULIC FILTER OF EACH TYPE(FOR HYDRAULIC OPERATED MECHANISM,IF APPLICABLE) for 765KV GIS CIRCUIT BREKAER 41 SPARES: 765KV GIS- HOSE PIPE OF EACH TYPE(AS APPLICABLE) (FORHYDRAULIC OPERATED MECHANISM,IF APPLICABLE) for 765KV GIS CIRCUIT BREKAER 42 SPARES: 765KV GIS - N2 ACCUMULATOR(FOR HYDRAULIC OPERATEDMECHANISM,IF APPLICABLE) for 765KV GIS CIRCUIT BREKAER 43 SPARES: 765KV GIS- VALVES OF EACH TYPE(FOR HYDRAULIC OPERATED MECHANISM,IFAPPLICABLE) for 765KV GIS CIRCUIT BREKAER 44 SPARES: 765KV GIS- PIPE LENGTH(COPPER & STEEL)OF EACH SIZE & TYPE(FOR HYDRAULICOPERATED MECHANISM,IF APPLICABLE) for 765KV GIS CIRCUIT BREKAER 45 SPARES: 765KV GIS- PRESSURE SWITCHES OF EACH TYPE(FOR HYDRAULIC OPERATED MECHANISM,IFAPPLICABLE) for 765KV GIS CIRCUIT BREKAER 46 SPARES: 765KV GIS- PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE(FOR HYDRAULICOPERATED MECHANISM,IF APPLICABLE) for 765KV GIS CIRCUIT BREKAER 47 SPARES: 765KV GIS- HYDRAULIC OIL(5% OF TOTAL OIL QUANTITY)(FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) for 765KV GIS CIRCUIT BREAKER 48 SPARES:765KV GIS- PRESSURE RELIEF DEVICE OF EACH TYPE(FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) for 765KV GIS CIRCUIT BREKAER 49 SPARES: 765KV GIS- COMPLETE SPRING OPERATING MECHANISMINCLUDING CHARGING MECHANISM ETC.(FOR SPRING OPERATED MECHANISM,IF APPLICABLE) for 765KV GIS CIRCUIT BREAKER 50 SPARES: 765KV GIS- COMPLETE HYDRAULIC-SPRING OPERATINGMECHANISM INCLUDING CHARGING MECHANISM ETC.(FOR HYDRAULIC-SPRINGOPERATED MECHANISM,IF APPLICABLE) for 765KV GIS CIRCUIT BREAKER 51 SPARES: 765KV GIS- PRESSURE SWITCHES OF EACH TYPE FOR 765KV GIS CIRCUIT BREAKER(For Hydraulic-Spring Operated Mechanism,if applicable) for 765KV GIS CIRCUIT BREAKER 52 SPARES:765KV GIS- PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE(FOR HYDRAULIC-SPRINGOPERATED MECHANISM,IF APPLICABLE) for 765KV GIS CIRCUIT BREKAER 53 SPARES: 765kV GIS- Single phase of 3150Adisconnector switch including maincircuit,enclosure,driving mechanismand support insulator etc.,complete in all respect 54 SPARES: 765KV GIS- SINGLE PHASE MAINTENANCE EARTHING SWITCH INCLUDING MAINCIRCUIT,ENCLOSURE,DRIVING MECHANISM AND SUPPORT INSULATOR ETC., COMPLETE IN ALL RESPECT 55 SPARES: 765KV GIS - SINGLE PHASE FAST EARTHING SWITCH INCLUDING MAIN CIRCUIT, ENCLOSURE,DRIVING MECHANISM AND SUPPORT INSULATOR ETC.,COMPLETE INALL RESPECT 56 SPARES: 765KV GIS- OPEN/ CLOSE CONTACTOR ASSEMBLY,TIMERS,KEY INTERLOCK,INTERLOCKINGCOILS,RELAYS,PUSH BUTTONS,INDICATING LAMPS,POWER CONTACTORS, RESISTORS,FUSES,MCBS & DRIVE CONTROL CARDS ETC.(AS APPLICABLE)ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 765KV GIS DISCONNECTORSWITCH 57 SPARES: 765KV GIS- OPEN/ CLOSE CONTACTOR ASSEMBLY,TIMERS,KEY INTERLOCK,INTERLOCKINGCOILS,RELAYS,PUSH BUTTONS,INDICATING LAMPS,POWER CONTACTORS, RESISTORS,FUSES,MCBS & DRIVE CONTROL CARDS ETC.(AS APPLICABLE)ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 765KV GIS MAINTENANCE EARTH SWITCH 58 SPARES: 765KV GIS- OPEN/ CLOSE CONTACTOR ASSEMBLY,TIMERS,KEY INTERLOCK,INTERLOCKINGCOILS,RELAYS,PUSH BUTTONS,INDICATING LAMPS,POWER CONTACTORS, RESISTORS,FUSES,MCBS & DRIVE CONTROL CARDS ETC.(AS APPLICABLE)ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 765KV GIS FAST EARTHING SWITCH 59 SPARES: 765KV GIS- LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR DISCONNECTOR 60 SPARES: 765KV GIS- LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR MAINTENANCE EARTHING SWITCH 61 SPARES: 765KV GIS- LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR FAST EARTHING SWITCH(IF APPLICABLE) 62 SPARES: 765KV GIS- DRIVE MECHANISM FOR 765KV GIS DISCONNECTOR SWITCH 63 SPARES: 765KV GIS- DRIVE MECHANISM FOR 765KV GIS MAINTENANCE EARTH SWITCH 64 SPARES: 765KV GIS- DRIVE MECHANISM FOR 765KV GIS FAST EARTHING SWITCH 65 SPARES: 765KV GIS- MOTOR FOR DRIVE MECHANISM FOR 765KV GIS DISCONNECTOR SWITCH 66 SPARES: 765KV GIS- MOTOR FOR DRIVE MECHANISM FOR 765KVGIS MAINTENANCE EARTH SWITCH 67 SPARES: 765KV GIS- MOTOR FOR DRIVE MECHANISM FOR 765KV GIS FAST EARTHING SWITCH 68 SPARES: 765KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER(3 CORES,TYPE-CTA) WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT 69 SPARES: 765KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER(2 CORES,TYPE-CTB) WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT 70 SPARES: 765KV GIS- SINGLE PHASE VT WITH ASSOCIATED ENCLOSURE COMPLETE IN ALLRESPECT 71 SPARES: 765KV GIS- TRANSDUCER FOR CB & CSD 72 SPARES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS-SPARES: 765KV GIS- GIS METALLIC ENCLOSURE 73 SPARES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS-SPARES: 765KV GIS- EXPANSION BELLOWS/ JOINTS 74 SPARES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS-SPARES: 765KV GIS- TEE BEND 75 SPARES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS-SPARES: 765KV GIS- L BEND 76 SERVICES- 765kV GIS: SUPERVISION OF ERECTION OF GIS 77 SERVICES- 765kV GIS:SUPERVISION OF ERECTION OF GAS INSULATED BUS DUCT 78 SERVICES- 765kV GIS:SUPERVISION OF ERECTION OF SF6 TO AIR BUSHING 79 SERVICES- 765kV GIS:TESTING & COMMISSIONING OF GIS 80 SERVICES- 765kV GIS : TESTING & COMMISSIONING OF GAS INSULATED BUS DUCT 81 SERVICES- 765kV GIS : TESTING & COMMISSIONING OF SF6 TO AIR BUSHING 82 SERVICES- 765kV GIS : FINAL SUCCESSFUL HV/ POWER FREQUENCY TESTING OF GIS INCLUDING ARRANGING OF HV TEST KIT ALONG WITH OPERATOR 83 SERVICES- 765kV GIS : INSULATION CO-ORDINATION STUDIES FOR GIS SYSTEM 84 SERVICES- 765kV GIS : TRAINING FOR GIS AT SITE 85 SERVICES- 765kV GIS : TRAINING FOR GIS AT MANUFACTURER WORKS 86 SERVICES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICES: SERVICES- 765kV GIS: REF. UNIT PRICE OF GIS INDIVIDUAL ITEM/ EQUIPMENT - SERVICES FOR SUPERVISION OF ERECTION OF GIS 87 SERVICES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICES: SERVICES- 765kV GIS: REF. UNIT PRICE OF GIS INDIVIDUAL ITEM/ EQUIPMENT - SERVICES FOR TESTING & COMMISSIONING OF GIS 88 SERVICES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICES: SERVICES- 765kV GIS: DEMOBILIZATION AND REMOBILIZATION CHARGES FOR GIS ERECTION SUPERVISION TEAM 89 SERVICES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICES: SERVICES- 765kV GIS: DEMOBILIZATION AND REMOBILIZATION CHARGES FOR GISTESTING & COMMISSIONING TEAM 90 SERVICES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICES: SERVICES- 765kV GIS: DEMOBILIZATION & REMOBILIZATION CHARGES OFHV TEST KIT ALONG WITH OPERATOR