Tender For Biennial Maintenance Of 440/230Volts Power Distribution System At Hwp (M) Colony (2024-26), Bhadradri Kothagudem-Telangana

Heavey Water Board-HWB has published Tender For Biennial Maintenance Of 440/230Volts Power Distribution System At Hwp (M) Colony (2024-26). Submission Date for this Tender is 22-04-2024. Mechanical engineering Service Tenders in Bhadradri Kothagudem Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

43154020
Tender For Biennial Maintenance Of 440/230Volts Power Distribution System At Hwp (M) Colony (2024-26)
Open Tender
Indian
Telangana
Bhadradri Kothagudem
22-04-2024

Tender Details

Tender For Biennial Maintenance Of 440/230Volts Power Distribution System At Hwp (M) Colony (2024-26)

Key Value

Document Fees
Refer document
EMD
INR 79880.0 /-
Tender Value
INR 39.94 Lakhs /-

BOQ Items

Name of Work: Biennial Maintenance of 440/230Volts power Distribution System at HWP (M) Colony (2024-26)
Sl. No. Item Description
1Maintenance of Sub Main Distributioin Board at Type all Type quarters like cleaning, tightning the incoming & out going terminals at double pole ELCB, MCB and Bus Bar, reterminating the damaged terminal with proper lugging closing the doors with panel lock, screws, including testing/ calibration of ELCB for sensitivity of 30mA etc. including refixing the box to the wall if required twice in a year. Note:- Hard ware materials,lugs, insulation tapes etc. as required for the work in the scope of department but complete Man Power with Tools & Tackels is under the scope of the Contractor.
2Maintenance of Energy Meter Panels like cleaning at the panel inside from dust & vermine, checking, tightning of connections/Terminals at all cut-out/MCBs, Energy Meters incoming, MCB/Isolator, indication lamps and terminations of all out going circuits replacement of all defective componenets, like Energy Meters, MCBs, Bus bars, wiring, lugs, bolt, nuts etc. and checking the locking system of panel doors, and making the same good as required and as directed by the Enigineer Incharge.Each once in a period of once in a year.Note:- Hardware materials, lugs, insulation tapes, cleaning agents etc. as required for the work is in the scope of department but complete Man Power with Tools shall be under the scope of the Contractor.
3Maintenance of Lighting Distribution boards at public buildings like cleaning, checking, replacement of 4 Pole MCB/ELCB, outgoing MCBs, tightening/reterminating the cable ends all out going & incoming inside the box,checking, fixing in position of the box/ cubicle at wall etc. as required and directed by Engineer Incharge. Note: Hardware materials, lugs, insulation tapes etc. as required for the work in the scope of department but complete Man Power with Toolsshall be under the scope of the Contractor.
4Maintenance of Feeder Pillers like cleaning the cubicle inside and outside checking the tightness of incoming and out going cable terminations,retermination of damaged deteriorated lugs, connectors/bolts, connectingwires.Replacement of CMM Type FSDU/MCCB/MCB, Bus-bars, etc. in complete and making the door locking arrangement intact by repair etc. as required as directed by Engineer-incharge. Note: Hardware materials, lugs, insulation tapes, cleaning agents etc. as required for the work in the scope of department but complete Man Powershall be under the scope of the Contractor.
5Maintenance of Distribution boards/ Junction boxes connected to 3 legged, 4 legged and Highmast tower lighting including opening the boxes cleaning the box inside & outside tightning the terminal connections at contactors, timers, MCBs, bus bar, retermination burnt & damaged terminals, replacement of components, checking & making the doors locking arrangement installation etc as required and as directed by Engineer in charge. Note:- Maintenance as above shall be done once in a period of one year the materials like timer, contractor, MCBs, wires & tapes etc as required for work shall be under the scope of the department but man power shall be under the scope of the contractor.
6Maintenance of LT (440Volts) compartamentlised Power Distribution panels comprising with ACBs, MCCBs, SFU, FU,as incoming and outgoing feeder switching devices like cleaning the cubicle, checcking &tightning ofall terminal connections, operational checks of all MCCB, ACB, MCB, indication lamps, replacement of defective components, checking the healthiness of wiring, earthing connections etc. as required and as directed by Engineer in charge. Note:- Maintenance as above shall be done once in a period of one year.The materials like timer, contactors, MCBs, wires & taps etc as required for work shall be under the scope of the department but man powershall be under the scope of the contractor.
7Supply and fixing of following spares for EM Panels, Feeder Pillars and Motors. All materials supply with Engineer Incharge clearence.
830A, 3 way Bakelite connectors,Fusion make or equivalent.(For using in Energy meters panels) - Refer Rate analysis sheet
9800W Air Blower ,Bosch or Dewalt make
10FR3, 250A, B2/B3 Suitable fuse link, FN Type TPN Switch Disconnector fuse unit.
11Max. Motor Output at 415V, 3-Ph, 20HP, 15kW, MN 32 DOL, Direct-on-Line Starters -Refer Rate analysis sheet
12FR3, 250A, Type C03-250, Changeover Switch-Disconnector -Refer Rate analysis sheet
13FR3, 250A, Type C03-250, Changeover Switch-Disconnector with Sheet Steel Encloser -Refer Rate analysis sheet
14Earth work in all kinds of soils, excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. (ESS-2,Energy meters panels,Feeder pillars,etc) -Refer Rate analysis sheet
15Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.(ESS-2) -Refer Rate analysis sheet
16Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering 1:3:6 at ESS-1 & 2 ,etc (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) -Refer Rate analysis sheet
17Providing Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in Cement mortar 1:6 (1 cement : 6 Coarse sand) for damaged energy meters panels replacement wall areas in quarters -Refer Rate analysis sheet
18Providing Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. Complete 40 mm thick with 20 mm nominal size stone aggregate. For using as smooth finish layer after item.No:10 -Refer Rate analysis sheet
19Providing 12mm thick cement plaster of mix 1:4 (1 cement 4 times sand) at all levels -Refer Rate analysis sheet
20Demolishing cement concrete manually by machanically means including disposal of materials with in 50 mts. Lead as per direction of Engineer Incharge. (In ESS-1 & 2) -Refer Rate analysis sheet
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail