| 1 | M&L for Servicing and maintanence forIndoor and outdoor unit of split type Air conditioners 1.5/2.00 Ton capacity taking down carefully indoor unit servicing and cleaning of filter, blower, Indoor coil assy, PCB, terminal block, frame grill assy incl greasing for blower motor complete withreassembling the same one, includinggood cleaning carefully for outside area used soft cloth with colin/ shopand testing the same to the entire satisfaction of Engineer-in-Charge, complete all as directed. |
| 2 | M&Lin repair for Disconnecting, cutting and taking out EvaporatedCoilfor indoorunitfor 1.5 ton AC Invertor/Non invetor typefind out gas leaking area and brazing work complete and cleaning refitting with testingcomplete all as specified and directed by the Engineer-in-charge. Note :- The cost of itemshall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account. |
| 3 | M&Lin repair for condensing coil disconnecting, cutting and taking outoutdoorunit Condensing coil for outdoor unitfor 1.5 ton AC Invertor/Non invetor type cheacking of gas leaking area and brazing work complete andrefitting with testingcomplete all as specified and directed by the Engineer-in-charge. Note :- The cost of itemshall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account. |
| 4 | M&Lfor Disconnecting, cutting and taking out EvaporatedCoilfor indoorunitfor 2.0 ton AC Invertor/Non invetor typefind out gas leaking area and brazing work complete and cleaning refitting with testingcomplete all as specified and directed by the Engineer-in-charge. Note :- The cost of itemshall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account. |
| 5 | M&Lfor condensing coil disconnecting, cutting and taking outoutdoor unit Condensing coil for outdoor unitfor 2.0 ton AC Invertor/Non invetor type cheacking of gas leaking area and brazing work complete andrefitting with testingcomplete all as specified and directed by the Engineer-in-charge. Note :- The cost of itemshall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account. |
| 6 | M&Lfor condensing coil disconnecting, cutting and taking outoutdoor unit Condensing coil for outdoor unitfor 3.0 ton TowerAC Invertor/Non invetor type cheacking of gas leaking area and brazing work complete andrefitting with testingcomplete all as specified and directed by the Engineer-in-charge. Note :- The cost of itemshall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account. |
| 7 | M&L forDisconnecting, cutting and taking out unserviceable compressor1.5 Ton Window type ACand replacing with same new compressor including soldering /brazing as required withgas charging in the compressor making electrical and machanical connections all inclusive and testing on load complete all as specified and directed by the Engineer-in-charge.Make :Highly/Bluestar/LLoyd/CarrierNote :- The cost of gas shall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account. |
| 8 | M&L forDisconnecting, cutting and taking out unserviceable compressor3.0 Ton Towertype ACand replacing with same new compressor including soldering /brazing as required withgas charging in the compressor making electrical and machanical connections all inclusive and testing on load complete all as specified and directed by the Engineer-in-charge.Make :Highly/Bluestar/LLoyd/CarrierNote :- The cost of gas shall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account. |
| 9 | M&L forDisconnecting, cutting and taking out unserviceable compressorinveter type for 1.5 Ton Split type ACand replacing with same new compressor including soldering /brazing as required withgas charging in the compressor making electrical and machanical connections all inclusive and testing on load complete all as specified and directed by the Engineer-in-charge.Make :Highly/Bluestar/LLoyd/CarrierNote :- The cost of gas shall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account. |
| 10 | M&L for Disconnecting, cutting and taking out unserviceable compressor inverter type for 2 Ton Spilt type ACand replacing with same new compressor including soldering /brazing as required withgas charging in the compressor making electrical and machanical connections all inclusive and testing on load complete all as specified and directed by the Engineer-in-charge.Make :Highly/ Voltas/Bluestar/LLoyd/CarrierNote :- The cost of gas shall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account. |
| 11 | M&L forDisconnecting, cutting and taking out unserviceable compressornon Inverter typefor 1.5 Ton/ 2.00 TON Spilt type ACand replacing with same new compressor including soldering /brazing as required withgas charging in the compressor making electrical and machanical connections all inclusive and testing on load complete all as specified and directed by the Engineer-in-charge.Make :Highly /Bluestar/LLoyd/CarrierNote :- The cost of gas shall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account. |
| 12 | S&F in repair (Existing make & size )Panel control Boardof Invrter type including remote and display of 1.5/ 2.0 Ton AC, complete all as specified and directed. |
| 13 | S&F in repair (Existing make & size )Panel control Boardof non Invrter typeof 1.5/ 2.0Ton AC, complete all as specified and directed. |
| 14 | S&F in repair (existing same size ) Indoor unit blower motorfor 1.5 Ton capacity AC, complete all as specified and directed. |
| 15 | S&Fin repair (existing same size ) Indoor unit blower of fan and bushes for 1.5 Ton capacity AC, complete all as specified and directed. |
| 16 | S&F in repair (existing same size ) Indoor unit blower motor for 2.0 Ton capacity AC, complete all as specified and directed. |
| 17 | S&F in repair (existing same size ) Indoor unit blower of fan and bushes for 2 Ton capacity AC, complete all as specified and directed. |
| 18 | S&F in repair (existing same size )outdoor unit Condensor motorfor 1.5 Ton capacity AC, complete all as specified and directed. |
| 19 | S&F in repair (existing same size )outdoor unitcondensor Fan blade withbushes for 1.5 Ton capacity AC, complete all as specified and directed. |
| 20 | S&F in repair (existing same model & size )outdoor unit condensor motorfor 2.0 Ton capacity AC, complete all as specified and directed. |
| 21 | S&F in repair (existing same model & size )outdoor unitcondensor Fan blade with bushes for 2.0 Ton capacity AC, complete all as specified and directed. |
| 22 | S&F in repair Hot and cold reversivle valve with resistance (eixsiting same model & size ) for 1.5/2.0 Ton capacity AC, complete all as specified and directed. |
| 23 | S&F in repair (existing same model & size )of window AC fan motorfor 1.5/2 Ton capacity AC, complete all as specified and directed. |
| 24 | S&F in repair (existing same model & size ) of window AC fan motor blade 1.5/2 Ton capacity AC, complete all as specified and directed. |
| 25 | S&F in repair running capacitor 45 mfd + 3 mfd for 1.5 ton AC (combined unit), complete all as specified and directed by Engineer-in-Charge. Make :- Apcos/Natraj/Tesla/Spark |
| 26 | S&F in repair running capacitor 50+4 mfd for 2.0 ton AC (combined unit), complete all as specified and directed by Engineer-in-Charge.Make :- Apcos/Natraj/Tesla/Spark |
| 27 | S&F in repair starting capacitor 80 mfd - 100 mfd for 1.5/2.0 ton AC and deep freezer complete all as specified and directed by Engineer-in-Charge. Make :- Apcos/Natraj/Tesla/Spark |
| 28 | S&F in repair (Swing motor for indoor unit, complete all as specified and directed by Engineer-in-Charge. |
| 29 | S&F in repair capacitor 3.15 mfd for indoor unit, all as specified and directed by Engineer-in-Charge.Make :- Apcos/Natraj/Tesla/Spark |
| 30 | S&F in repair starting relay of 1.5/2.0 ton window AC complete all as specified and directed by Engineer-in-Charge.Make :- Renutrol/Indfoss |
| 31 | S&F in repair route pipe (copper tube) of size 3/8\" dia with insulation complete all as specified and directed by Engineer-in-Charge. |
| 32 | S&F in repair route pipe (copper tube) of size 5/8\" dia with insulation complete all as specified and directed by Engineer-in-Charge. |
| 33 | S&F in repair route pipe (copper tube) of size 1/4\" dia with insulation complete all as specified and directed by Engineer-in-Charge. |
| 34 | S&F in repair route pipe (copper tube) of size 1/2\" diawith insulation complete all as specified and directed by Engineer-in-Charge. |
| 35 | S&F in repair flap rest for indoor unit of 1.5/2.0 ton ac (existing size ) completeall as specified and directed by Engineer-in-Charge. |
| 36 | S&F in repair Air filtr for indoor unit of 1.5/2.0 ton ac (existing size ) completeall as specified and directed by Engineer-in-Charge. |
| 37 | S&F in repair (existing same model) codensing coil of outdoor unit complete for 1.5 Ton AC all as specified and directed by Engineer-in-Charge. |
| 38 | M&L for in repair (existing same model) codensing coil of outdoor unit complete for 2.0 Ton AC all as specified and directed by Engineer-in-Charge. |
| 39 | Supply and refilling of gas R-22 & 32 in 2 .0 /1.5 Ton AC including necessary arrangement for gas filling complete all as specified and directed by Engineer-in-Charge. |
| 40 | Supply andrefilling of gas R-410ain 1.5 /2.0 Ton AC including necessary arrangement for gas filling complete all as specified and directed by Engineer-in-Charge. |
| 41 | M&L in repair(existing same model & size ) Copper filter for 2.0 ton split ACcomplete all as specifed and as directed |
| 42 | M&L for in repair (existing same model & size ) Copper filter for 1.5 Ton split AC complete all as specifed and as directed |
| 43 | Supply and replacing (existing same model & size ) Suction valve for 1.5/2.0 ton AC complete all as specifed and as directed |
| 44 | Supply and replacing (existing same model & size ) Discharge valve for 1.5/2.0 tonAC.complete all as specified and as directed |
| 45 | M&Lfor Brazing of condensing / cooling pipe including copper tube etc of sufficent length if required complete all as specified and directed by Engr-in-Chage |
| 46 | Supply and replacingElectronic Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designedlow and high voltage cut out protection for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA. |
| 47 | Supply and replacingElectronic Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designedlow and high voltage cut out protection for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA. |
| 48 | Supply and replacingElectronic Voltage stabilizer of capacity 3 to 5 KVA for automatic operation, single phase naturally air cooled indoor type & designedlow and high voltage cut out protection for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 to 5 KVA. |
| 49 | M&Lfor taking out the voltage stabilizer of capacity 4 to 5 KVA single phase and rewinding of the main transformer unit with standard copper enamelled wire and making connection (internal), testing the stabilizer to the entire satisfaction of Engineer-in-Charge, complete all as directed. |
| 50 | Supply and replacing (existing same model & size ) control card of voltage stabilizer PCB sensor etc.complete all as specified and directed by Engineer-in-Charge. |
| 51 | Supply and replacing selector switch for input and output voltage all as specified and directed by Engineer-in-Charge.Note :- Spares required for repair work will be measured and paid for separately under respective item of BOQ. |
| 52 | Supply only in replacement Ics and relays completeall as specified and directed by Engineer-in-Charge. |
| 53 | Supply only in replacement of ACContactors 2Pole 16 Amps completeall as specified and directed by Engineer-in-Charge. |
| 54 | Supply only in replacement of ACContactors 2Pole 32 Amps completeall as specified and directed by Engineer-in-Charge. |
| 55 | M&L for Taking out the Refrigerator of capacity 280/310 Ltr and replacement of following parts, reassembly of unit and testing the same to the entire satisfaction of the Engineer-in-Charge. |
| 56 | Supply only in replacement compressor invetor/non invetor type sealed unit including necessary brazing work as required. |
| 57 | Supply only in replacement Thermostate switch suitable for 280/310 Ltrs caapcity refrigerator. |
| 58 | Supply only in replacement gas in the compressor of refrigerator of any make and capacity with R-134a gas/ carbon free gas. |
| 59 | Supply only in replacement (existing same model) of defrost timer for domestic refrigerator complete all as specified and directed by the Engineer-in-charge. |
| 60 | Supply only in replacement thermal overload relay for 280/310 Ltrs capacity refrigerator complete all as specified and as directed.Make :- Renutrol/Indfoss or equivalent as approved by GE. |
| 61 | M & L in repair for refrigerator of capacity 165/210 ltr and replacement of the following spares required for repairwork including reassembly and testing all as directed. Note :- Spares required for repair work will be measured and paid for separately under respective item of BOQ. |
| 62 | Supply only in replacement Thermostate switch suitable for 165/210 Ltrs caapcity refrigerator complete all as specified and as directed |
| 63 | Supply only in replacement Capilliary tube including brazing work completeall as specified and as directed by Engineer in charge. |
| 64 | Supply only in replacement thermal over load relay complete all as speciefed and as directed . |
| 65 | Supply only in replacement of compressor sealed unit including necessary brazing work as required. |
| 66 | Supply only in replacement of replacement of Ics and relay complete all as specified and as directed |
| 67 | Supply only in replacement of replacement of PCB Boardcomplete all as specified and as directed |
| 68 | Supply only in replacement for Taking out Deep Freezer 320 Ltr capacity 230 V AC 50HZ , supply and replacement of following unserviceable parts, reassembling the same after repair and testing on load after completionof job, all as directed. Note :- Spares required for repair work will be measured and paid for separately under respective item of BOQ. |
| 69 | Supply only in replacement compressor sealed unit including necessary brazing work as required. Make ; Voltas/ blue star/ carrier |
| 70 | Supply only in replacement blower motor for any cap/size of deep Freezer complete all as specified and as directed . |
| 71 | Supply only in replacement thermal over load relay. Make :- Renutrol/Indfoss or equivalent as approved by GE. |
| 72 | Supply only gasincluding necessary arrangement for gas filling complete all as specified and as directed . |
| 73 | Supply only in replacement of replacement of PCB Boardcomplete all as specified and as directed |
| 74 | Supply only in replacement thermostate switch. Make :- Renutrol/Indfoss or equivalent as approved by GE. |
| 75 | M&L in repair for Taking down indoor/outdoor unit of capacity 1.5/2.0 ton capacity after opening electrical connections, securing the refrigerant gas in the compressor and opening refrigeration pipe line safely. Shifting the inddor/outdoor unit for fixing at new places, mounting after drilling hole over out door unit stands, fixing pvc pipe 80 mm dia withwhite cement and connecting refrigeration pipe line with indoor unit, electrical connection and charging refrigeration gas complete all as specified and directed by Engr-in-Charge. Note :- Additional Refrigerant gas and copper pipe line and insulation will be measured and paid for separately |
| 76 | Supply and replacement complete set of out door unit including compressor,condensing coil and complete acessories of split type AC 2.0 ton capacity, complete all as specified and directed by the Engineer-in-charge.(Make : Voltas/Bluestar/LLoyd/Carrier/ godrej) |
| 77 | Supply and replacement complete set of out door unit including compressor,condensing coil and complete acessories of split type AC 1.5 ton capacity, complete all as specified and directed by the Engineer-in-charge.(Make : Voltas/Bluestar/LLoyd/Carrier/ godrej) |
| 78 | M&L in repair for stands for outdoor unit including drilling hole, nuts bolts, fastners etc complete all as required at site. |
| 79 | M&L in repair for Submain wiring with 2 x single core PVC insulated flexible copper conductor cable FRLS of size 4 sqmm and one single core PVC insulated flexible copper conductor cable of green colour of size 4.0 Sqmm as earth lead in & including surface PVC conduit light grade fixing to wall with clamps complete all as specified anddirected by Engr-in-Charge |
| 80 | S&F in repair forfoming copper tubing insulation Air conditioner insulated Tube 1/2\",1/4\",3/8\" &5/8\" section and discharge pipe for A C cap 1.05/2.0 Ton Split Type |
| 81 | S&F in repair forPVCflexibale Pipe 20/40 MM includingsuitable size of clips,Nails,fixing of walls as per existing complete all as specified and as directed. |
| 82 | S&F in repair for replacementofMetal Clad plug and socket Boxcomplete all as specified and as directed. |
| 83 | M&L in repair for replacement MCB DB Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB20 amps complete all as specified and directed by the Engineer-in-charge. |
| 84 | M&L in repair for Maintenance and servicing of water cooler 40/80, 60/120 and 150 Ltrsat site, cleaning the equipment, checking wiring , running and starting capacitor, thermostatic switch, condenser motor, blower fan, rectification of fault replacement of spare and charging of gas as on required basisconnecting & testing on load for performance complete all as specified and directed by the Engineer-in-charge. Note :- Spares and gas required shall be measured and paid for separately. |
| 85 | M&L in repair for(existing same model)blower motor of water cooler 40/80, 60/120 and 150 Ltrs capacityconnecting & testing on load complete all as specified and directed by the Engineer-in-charge. |
| 86 | Supplyin repair of push cock press push type MS chromium plated suitable for 15 mm bore pipe for water cooler complete all as specified and directed by the Engineer-in-charge. |
| 87 | Supply in repair of float valve with PVC float ball brass stem & fly nut complete with screwed for iron pipe 15 mm bore complete all as specified and directed by the Engineer-in-charge. |
| 88 | Supply & refilling of gas R-34a including necessary arrangement for gas filling complete all as specified and directed by engineer-in-charge. |
| 89 | Supply in repair of compressor water coolersealed unit including necessary brazing work as required complete all as specified and as directed . |
| 90 | Servicingof desert cooler installed at site, cleaning the equipment with air blower fan and wiping , dry and wet cleaning of body and louver preparation of surface for painting with soft wire brush and painting the cooler with one coat of synthetic enamel paint checking the control wiring, fan & motor, tullu pump and replacement of the following plastic part of tullu pump and cooler body and oiling of the pump & motorcomplete all as specified and directed by the Engineer-in-charge. |
| 91 | Supply in repairof wood wool pad set suitable for desert cooler complete all as specified and directed by the Engineer-in-charge. |
| 92 | Supply in repair of Plug top with 1.5 sq mm cable 3 meter long for desert cooler, water cooler & refrigerator completeall as specifed and as directed by Engineer in charge. |
| 93 | Supply in repair ofwater lifting pump single phase,230 vol for desert cooler complete all as specified and directed by the Engineer-in-charge. |
| 94 | Supply and replacement of PVCpipe 15 mm dia for desert cooler as per site requirment and making connection for free flow water complete all as specified anddirected |
| 95 | Supply in Repair of fan motor & Fan blade for desert cooler existing size. All specified and directed |
| 96 | Supply in repair of3 way PVC water distributor for desert cooler including nuts and bolts suitable size & PVC elbow all as specified and directed. |
| 97 | Supply in repair of motor 230 Volts, Single Phase, 1440 RPM for desert cooler complete all as specified anddirected by the Engineer-in-Charge. Make:- Khaitan/Universal or rquivalent as approved by GE. |
| 98 | Supply in repairof indoor unit complete set for split type AC 1.5 ton capacity, complete all as specified and directed by the Engineer-in-charge.(Make : Voltas/Bluestar/LLoyd/Carrier/ godrej) |
| 99 | Supply only and replacement of indoor unit complete set for split type AC 2.0 ton capacity, complete all as specified and directed by the Engineer-in-charge.(Make : Voltas/Bluestar/LLoyd/Carrier/ godrej) |
| 100 | Supply and replacement of relay for split type AC 1.5 ton capacity, contact relay per pole 22 V - 163 complete all as specified and directed by the Engineer-in-charge. |
| 101 | Supply and replacement of cable PVC insulated sheathed 3 core copper conductor size4 sqmm complete all as specified and directed by the Engineer-in-charge. |
| 102 | Supply and replacement of cable PVC insulated sheathed 3 core copper conductor size 2.5 sqmm complete all as specified and directed by the Engineer-in-charge. |
| 103 | Supply and replacement of PVCdrain pipe 3 mtr length suitable for All type ACcomplete all as specified and directed by the Engineer-in-charge. |
| 104 | Supply and replacement of PVC drain pipe 1 mtr length suitable for All type AC complete all as specified and as directed by the Engineer-in-charge. |
| 105 | Taking outofthe splittype AC and refixing of New location /Existinglocation includingservicing Testing/commissioning etc all as speciefied and as directed |
| 106 | M&L for Servicing oftowerAir conditioners 3 .00 Ton capacity indoor unit /Out door unit servicing and cleaning of filter, blower, Indoor coil assy, PCB, terminal block, frame grill assy incl greasing for blower motor complete withreassembling the same one, includinggood cleaning carefully for outside area used soft cloth with colin/ shopand testing the same to the entire satisfaction of Engineer-in-Charge, complete all as directed. |
| 107 | Supplyin repair of replacement ofPCB Boardof Portable Type ACcomplete all as specified and as directed |
| 108 | Supplyin repair of replacement of Blower Motor of Portable Type ACcomplete all as specified and as directed |
| 109 | Supplyin repair of replacement of PCB Displayof Portable Type ACcomplete all as specified and as directed |
| 110 | Supplyin repair of replacement ofPCB motorof Portable Type ACcomplete all as specified and as directed |