Tender For Increasing Capacity Of 33 / 11Kv Sub Station Safdarganj From 2X5 Mva To 5+10 Mva In Distt Barabanki.; 1 Safeloading, Carriage And Then Safeunloading Of The Following Material From Store Centres Under The Jurisdiction Of Eeesd Ayodhaya To Dump Site Proper Stacking. 2 33 Kv Bus Isolator 3 33 Kv Lightening Arrestor 4 33 Kv Vcb 800A, 750 Mva 5 Acsr Dog Conductor 6 11 Kv 3 Core Cable 3X300 Mm Xlpe 7 11 Kv Cable 3X185 Sq. Mm Xlpe 8 11 Kv Cable Jointing Kit Indoor 3X300 Sq.Mm. Xlpe 9 11 Kv Cable Jointing Kit Outdoor 3X300 Sq.Mm. Xlpe 10 11 Kv Cable Jointing Kit Indoor 3X185 Sq.Mm. Xlpe 11 11 Kv Cable Jointing Kit Outdoor 3X 185 Sq.Mm. Xlpe 12 24 Volt Battery & Battery Charger With Cabinet 13 M.S. Channel 125X65 ( For Structures ) 14 M.S. Angle 75X75x8 ( For Structures ) 15 Opening Of All The 33 Kv Jumpers, Neutral Connections, Cable Connections, Opening Of Earth Strips And Then Shifting Of 5 Mva T / F From Plinth To Other Side In Yard. 16 Shifting 33 Kv Jumpers, From Actual Position To The New Shifted Place Along With 11 Kv Cable And Other Accessories For Maintaining & Restoring The S / S Supply 17 Plinth Of 10 Mva, 33 / 11 Kv T / Fsexpansion And Major Repairing Of Existing 5 Mva T / F Plinth Of Less Size To 3.5 Mtr X 3.5 Mtr Suitable For 10 Mva T / F By Rcc Work Of Ratio 1:2:4 Using M.S. Bar 10 Mm Dia ( Tor ) Inreinforcement Including Cutting, Bending And Binding In Required Shape Complete In All Respect And Shall Be Plastered / Finished On Top And Side Of The Plinth. 18 Plinth For 33Kv Vcbconstruction Of Plinth Of Size 2.0X1.5X0.9 ( Mtr ) Suitable For Erection Of Super Structure For 33 Kvvcb Including Grouting Of Anchor Bolts In Proper Allingment And Level. Scope Of Work Includes Excavation Of Foundation Base Concreting In Cc 1:6:12 ( Cement, Fine Sand And Brick Ballast ) 1St Class Brick Work In Cement Mortor Of Ratio 1:4 Cc In Ratio 1:4:8 And Rcc Work In Ratio 1:2:4 ( Cement, Coarse Sand And Stone Grit Of 20 Mm Gauge ) As Per Drawing 19 H.T. Cable Layinglaying & Dressing Of 11 Kv, 3X300 And 3X185 Sq.Mm Xlpe Cable Underground From 10 Mva T / F To 11 Kv Incoming Switchgear In The Trench 450Mm Wide, 900Mm Deep, Providing 150Mm Fine Sand Cushion Bench And 150Mm Fine Sand Cushion Above The Cable. The Cable Shall Be Duly Protected By 1St Class Bricks Two Either Side And Third On Top Of The Cables, Laid In Series One After The Other, The Work Includes Supplying Offine Sand And Bricks, Refillingand Rammingof The Left Out Soil, Closing The Trench And Leveling. Spare Cable Shall Be Left And Buried In The Trench In The Safe Of Rings At Both Ends. Cable Laying Work Includes Unrolling, Cutting, Meggering And Sealing Both End Of The Cable. ( All The Material Will Be Supplied By The Contractor ) 20 Erection And Installation Of 33 / 11 Kv10 Mva Transformerdragging Of 33 / 11Kv 10 Mva T / F From Dump Site To Road Site And Shifting Of The T / F From Road Site To New Constructed Plinth Distance About 150Mtr , Along With Loading, Unloading And Carriage, Fixing And Fitting Of All The Accessiories And Filling Of T / F Oil To The Desired Level And Insuring That There Is No Leakage. Erection And Installation Of 33 / 11 Kv, 10 Mva Transformer In A Leveled Position On The Plinth. 21 Installation Of Bus Isolators Assembling And Installation Of Bus Isolator On The Isolator Structure , Adjusting Of Opening Mechanism In Proper Alignment So As To Ensured Smooth Operation Of The Same. In Case Of Line Isolator Proper Operation Of Earth Links Shall Also Be Ensured. The Work Includes Fabrication For Proper Fixing If Required. 22 Installation Of 33 Kv Vcbinstallation Of 33 Kv 750 Mva 800 Amp Vcb On 33 Kv Vcb Structure Along With Earthing By G.I. Strip 50X6 Mm Size With Main Earthmat Of Switchyards Complete In All Respect Including Commissioning. 23 Installation Of Lightening Arrestorsassembling And Installation / Mounting Of Lightening Arrestors On The L.A. Structure / Complete With Making Earth Connection ( Separate ) And Line Connections. The Work Includes Fabrication For Proper Fixing If Required. 24 Installation Of Heat Shrinkable Type Cable Jointing Kits Indoor And O / D End Termination And S / T Joint Suitable For 11Kv Xlpe Cable Confirming To Is Esi-09-13-Is-13573 Of 1992 Amendment I&Ii Vde-0278 Of Latest Version There Of If Any. 25 Cable Stand Structurefabrication & Erection Of 11 Kv Cable Stand Made Of 02 No. M.S Chanel 125X65x6 Mm 3 Mtr. Jointed To Each Other By M.S Channel Horizontally And Also Jointed To Each Other By Means Of 05 No. M.S Strip ( M.S Flat ) 50X6 Mm Of Size 200 Mm Long Each By Welding At Actual Distance Interval As Per Norms. And Grouting In Block Of 300X300x700 Completely Providing 02 No. Cable Clamps Also And Eathing By G.I Strip 50X6 Mm Size With The Earth Mat Of Switchyard Both Side Of Legs And Provideing Clamps , Post / Pin Insulator For Holding Cable. ( All The Materials Will Be Arranged By The Contractor Such That Clamps Nut Bolts And Civil Materials Except M.S Channel. ) 26 Neutral Standfabrication And Grouting Of M.S Channel 125X65 Mm L Shape & In Proper Size And Allignment To Provide Support For The Two Separate Earthing Strips For Pwer T / F Neutral Including Supply & Fixing Of Two No.Flexible Copper Bonds For Neutral Earthing. ( All The Materials Will Be Arranged By The Contractor Such That Clamps Nut Bolts And Civil Materials Except M.S Channel. ) 27 Supply & Laying Of 6X2.5 Sq.Mm. Sq. Armoured Control Cable From Power T / F To Controle Board In The Ground As Per Respo Norm With Proper Connection Vcb, Ct & Control Pannel With T / F To Battery And Battrey Charger, Bucholz Relay, Low Higher And Winding Temperture Protection Alarm Etc With Including All The Civil Material. ( All The Material Will Be Supplied By The Contractor ) 28 Supply & Laying Of 4X2.5 Sq.Mm. Sq. Armoured Control Cable From Power T / F To Controle Board In The Ground As Per Respo Norm With Proper Connection Vcb, Ct & Control Pannel With T / F To Battery And Battrey Charger, Bucholz Relay, Low Higher And Winding Temperture Protection Alarm Etc With Including All The Civil Material. ( All The Material Will Be Supplied By The Contractor ) 29 Supply & Laying Of 2X2.5 Sq.Mm. Sq. Armoured Control Cable From Power T / F To Controle Board In The Ground As Per Respo Norm With Proper Connection Vcb, Ct & Control Pannel With T / F To Battery And Battrey Charger, Bucholz Relay, Low Higher And Winding Temperture Protection Alarm Etc With Including All The Civil Material. ( All The Material Will Be Supplied By The Contractor ) 30 Special Earthing By Way Of Boring And Lowering Of B Class G.I. Pipe 50 Mm Dia 20Mtr Longfrom Ground Upto The Water Level Andit Will Be Connected To The G.I. Strip 50X6 Mm ( Providing & Laying Of G.S. Strip Including Cutting, Welding, Bending Etc. ) For Equipments ( L.A, T / F, C.T., Vcb.Etc ) . The Earth Strip Will Be Welded To The G.I. Pipe. The Work Also Includes Cap & Clamps For Pouring Water, The Cost Of All Material With All Labour & T&P Etc. Complete In All Respect. ( All The Material Will Be Supplied By The Contractor ) 31 Commissioning ( Testing Control Wiring Etc ) Of 10 Mva T / F, .33 Kv Vcb & 33 Kv T / F Control Panel And Its Eqipments, Etc.Installed In Switchyards And 11 Kv Incoming And Outgoing Pannels Complete In All Respect Upto Energising. 32 Painting Ofall Switchyard Sub Station Structures ( Old+New+Fencing ) With One Coat Of Ready Mixed Primer And 2 Coats Of Al.Paint Of Good Quality Including Cost Of Material, Labour And T&P Complete In All Respect. 33 Supply And Fixing Of P.G Clamp For Dog And Connector 34 Installation Of 24 Volt Battery ( 210 Ah ) & Battery Charger With Cabinet. With Its Proper Connection. 35 33 Kv Bay Bus Bar & Stringing.Stringing Of 33Kv Bay Bus Bar By Using And Laying Of Acsr Dog Conductor Including Making Vertical / Horizontal ( Y-Shape ) Jumperconnection Through Pg Clamps And Connecting All The Equipments ( Bus Isolator, P.I. , C.T. , Vcb, L.A & T / F ) With Each Other Through Connecting Clamps. ( All The Material Will Be Supplied By The Contractor ) 36 Reparing And Maintenance If Required Do Replacement Of Electrical And Machnical Components Of 33 Kv Control Pannel&33 Kv Vcb ( I.E, Tripping Coil, Tripping Rod, Mcb, Vaccum Interrupter, Relay, Replacement Of Damage Internal Wiring Etc. ) And Do Over Overhaling Of All Mechanical Parts Of 33 Kv Vcb For Proper Mechanism Work. 37 Reparing And Maintenance If Required Do Replacement Of Electrical And Machnical Components Of 11 Kv Control Pannel& 11 Kv Vcb ( I.E, Tripping Coil, Tripping Rod, Mcb, Vaccum Interrupter, Relay, Replacement Of Damage Internal Wiring Etc. ) And Do Over Overhaling Of All Mechanical Parts Of 11 Kv Vcb For Proper Mechanism Work. 38 Delta Type Earthing Of Power T / F Neutral Earthing Of Power T / F Neutral By Providing 03 No. Of B Class G.I. Pipe 50 Mm Dia 20 Feet Longfrom Ground Upto The Water Level ( Delta Type ) And Providing And Laying G.S. Strip 50 X 6 Mm Including Cutting, Welding, Bending Etc. Complete In All Respect. ( All The Material Will Be Supplied By The Contractor )