Electrification Work Of Ae ( C ) Enquiry Office And Type Iii Staff Quarter At Jal Vihar Colony- 1 Electrification Of Quarter No. A-2 Old Type-Iii Staff Quarter And Ae ( C ) Enquiry Office At Jal Vihar Colony By Carrying Out Following Works:-1.8 Wiring For Light Point / Fan Point / Exhaust Fan Point Call Bell Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Conduit, With Piano Type Switch, Phenolic Laminated Sheet, Suitable Size Msbox And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 1.8.1 - Group-A. 2 1.8.3 - Group-C. 3 1.14 / 3 Wiring For Circuit / Sub-Main Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 1.14.2 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire. 4 1.14.32 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire 5 1.14.24 X 10 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 6 1.29 / 6Supplying And Fixing Metal Box Of 150Mm X 75Mm X 60Mm Deep ( Nominal Size ) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Fron Including Providing And Fixing 3 Pin 5 / 6 Amps. Socket Outlet And 5 / 6 Amps Piano Type Switch, Connection, Painting Etc. As Required. ( For Light Plugs ) . 7 1.30 / 6 Supplying And Fixing Metal Box Of 180Mm X 75Mm X 60Mm Deep ( Nominal Size ) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 Amps Socket Outlet And 15 / 16 Amps Piano Type Switch, Connection, Painting Etc. Required. 8 1.25 / 6Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 9 1.33 / 7Supplying And Fixing 3 Pin, 5 A Ceiling Rose On The Existing Junction Box / Wooden Block Including Connections Etc. As Required. 10 1.34 / 7 Supplying And Fixing Brass Batten / Angle Holder Including Connection Etc. As Required. 11 1.38 / 8Supplying And Fixing Call Bell / Buzzer Suitable For Single Phase, 230 V, Complete As Required. 12 1.41 / 8 Installation, Testing And Commissioning Of Pre-Wired, Fluorescent Fitting / Compact Fluorescent Fitting Of All Types, Complete With All Accessories And Tube / Lamp Etc. Directly On Ceiling / Wall, Including Connections With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. As Required. 13 1.44 / 8 Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rods Of Standard Length Upt 30Cm With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor Single Core Etc. As Required. 14 1.50 / 9 Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. 15 2.2 / 12Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required ( But Without Mcb / Rccb / Isolator ) .8 Way, Double Door. 16 2.10 / 12Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, “C” Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.2.10.1 - Single Pole. 17 2.14.3 / 12Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 Volts, Residual Current Circuit Breaker ( Rccb ) , Having Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63 A. 18 Making Good The Damages By Required Civil Work As Per Requirement.