Tender For Electrical Repair Work Required At Chb Complex-Iii And Iv, Kasturba Niketan Lajpat Nagar, New Delhi- 1 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. 2 A ) Group A 3 A ) Group B 4 Rewiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable As Earth Wire In Existing Surface / Recessed Steel Conduit Including Dismantling As Required. 5 A ) Group A 6 A ) Group B 7 Supplying And Fixing Of Following Sizes Of Steel Conduit Along With Accessories In Surface / Recess Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 8 A ) 20 Mm 9 B ) 25 Mm 10 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 11 A ) 3 X 1.5 Sq.Mm 12 B ) 3 X 4 Sq.Mm 13 C ) 6 X 4 Sq.Mm 14 D ) 3 X 6 Sq.Mm 15 Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 16 B ) 3 Module ( 100Mmx75mm ) 17 C ) 6 Module ( 200Mmx75mm ) 18 D ) 8 Module ( 125Mmx125mm ) 19 E ) 12 Module ( 200Mmx150mm ) 20 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 21 A ) 5 / 6 Amp Switch 22 B ) 3 Pin 5 / 6 Amp Socket Outlet 23 C ) 15 / 16 Amp Switch 24 D ) 6 Pin 15 / 16 Amp Socket Outlet 25 Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. 26 Supplying And Fixing Of Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box I / C Connections But Excluding Modular Plate Etc As Reqd. 27 Supplying And Fixing Suitable Gi Box With Modular Plate And Cover In Front On Surface Or In Recess I / C Providing And Fixing 25A Modular Socket Outlet And 25A Modular Sp Mcb C Curve I / C Connection, Painting Etc As Reqd. 28 Supplying And Fixing 3 Pin, 5 Amp Ceiling Rose On The Existing Junction Box / Wooden Block Including Connection Etc As Required. 29 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet, Steel, Mcb Distributions Board, 240 Volts, On Surface / Recess, Complete With Tinned Copper Busbar, Neutral Busbar, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Phosphatized And Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 30 B ) 16Way Double Door 31 A ) 12Way Double Door 32 C ) 8Way Double Door 33 Supplying And Fixing Of Following Ways Surface / Recess Mounting, Vertical Type, 415 Volts, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 Amps Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting McbS ( But Without McbS And Incomer ) As Required . ( Note : Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required. ) 34 8 Way ( 4 + 24 ) , Double Door 35 Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 36 A ) Single Pole 37 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 38 A ) 40 Amp 39 A ) 63 Amp 40 Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required. 41 A ) 125 Amp, 16 Ka, Tpmccb 42 B ) 250 Amp, 35 Ka, Tpmccb 43 Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal / Coke And Salt As Required. 44 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface / Recessed Conduit / Submain Wiring / Cable As Required. 45 Supplying And Fixing Brass Batten / Angle Holder I / C Connection Etc As Reqd. 46 Supplying And Fixing Of Al. Led Batten Suitable For Conduit / Surface / Suspended Mounting A Stand Alone Fixtre With Power Consumption Of Maximum 20W Producinglumen Output Of 2000 Lumen Or More Having An Integral Driverand 50000Hrs. Of Life At L70. I.E The Lumen Output Of Fiture Reducesof 70% Of Its Original Output After 50000Hrs. Complete With All Accessories / Attachments Etc As Reqd. 47 Supplying Installation, Testing And Commissioningsurface / Recess Mounted Downlighter Of 15-18 Watt Led Square / Roundpanel With Pdc Aluminium Housing And Pmma Diffuser Makes It A Robust Luminairepowder Coated Finshed In White Housing With 5700K To 6000K Suitable For 230Volt 50Hz Ac Supply Etc. As Reqd. 48 Supplying Installation, Testing And Commissioningof 1X4 Led 36Watt Surface / Pendent Mounting Led Flat Panel 1X4Made Of Crca Sheet Steel With High Efficient Leds & Glare Freeopal Diffuser, Ip20i / C Connection With 1.5Sqmm Frls Copper Conductor Single Core Cable Suitable For 230Volt 50Hz Ac Supply Etc As Reqd. 49 Supplying Installation, Testing And Commissioningof 2X2 Led Fitting 36 Watt Energy Saving Surface / Recess Mounted Luminaire With 5700-6000K, 3400-4000 Lumen ( Lm ) High Efficiency Pmma Diffuser Gives Soft Glare Free Light, Suitable For Size 600Mmx600mm False Ceiling I / C Hanging Arrangement With Chain And Makingconnectionwith 1.5Sq Frls Copper Conductor Single Core Cable Suitable For 230Volt 50Hz Ac Supply Etc As Reqd. 50 Supplying, Installation, Testing & Commissioning Of 70Watt Led Flood Light Led Fitting ( Ip-66 ) Made Up Of Pure Polyster Powder Coated Pressure Die Cast Aluminium With Leds Haveoptical Grade Polycarbonate Lens & Electronic Driver For Better Distribution Of Light On Existing Street Light Pole With Power Factor>0.95, Thd<10%, Cri>70% , System Efficacy =120 Lm / W & Cct-3000K To 5700Kwith 4Kv Intertnal Surge Protection Along With Additional Surge Protection Of 10Kv.I / C Makingconnection Etc Complete Suitable For 230Volt 50Hz Ac Supply As Required. 51 Supplying. Installation, Testing And Commissioning Of 300 Mm Sweep Metallic Heavy Duty 900 Rpm Exhaust Fan Suitable For Operation On 230V, 50 Hz Single Phase Ac Supply Complete With Louvers / Shutters In The Existing Opening Including Making The Hole To Suit The Size Of The Above Fan Making Good The Damage And Connections Etc. As Reqd. 52 Supplying & Fixing 400Mm Sweep Wall Mounted Cabin Fan With Speed Regulator Oscilatting Type I / C Testing & Commsisioning Suitable For 230Volt 50Hz Ac Supply Etc As Reqd. 53 Supplying, Installation, Testing And Commissioning Of Ceiling Fan, ( 1200 Mm ) Including Wiring The Down Rods Of Standard Length ( Upto 30 Cm ) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Suitable For 230V, 50Hz Single Phase Ac Supply Etc. As Required. 54 Supplying & Laying Of Following Sizes Of Xlpe Insulated And Pvc Sheathed Aluminium Conductor Armoured Cable On Surface As Reqd. 55 A ) 3 X 6 Sqmm 56 B ) 3X10 Sqmm 57 B ) 3.5 X 35 Sqmm 58 B ) 3.5 X 50 Sqmm 59 Servicing And Overhauling Of The Existing Installed Air Washer Of Capacity 5000Cfm, Including Filter Wash With High Speed Machine , Chemical , Oiling , Greasing Of Pulley Etc Complete As Reqd. 60 Sitc Of The 3Phase Tefc Cast Iron Induction Motor , 3 Hp , 2.2Kw, 415 V, 4 Pole / 1500 Rpm, Dol, Foot Mounted, Copper Winding Including Connection Etc Complete As Reqd. ( Burnt Out / Unserviceable Motor Credit Back To The Contractor ) 61 Supplying And Fixing Of The Pulley Belt Of Required V Shaped Belt Of Size ( Length 77 Width 17Mm ) In The Existing Installed Pulley Of The Air Washer Etc Complete As Reqd. 62 Sitc Of The Self Priming Mono Block Pump 0.5Hp, Single Phase, Discharge Range: 3250 Lph, Head ( M ) : 42M, Flow Rate: 3250 Lph, Low Power Consumption , Rugged Design , Low Voltage , High Efficiencyin The Existing Installed Pulley Of The Air Washer Etc Complete As Reqd. ( Burnt Out / Unserviceable Motor Credit Back To The Contractor ) 63 Credit For Dismantle Materials:- 64 Assorted :Ceiling Fans 65 Assorted :Exhaust Fan 66 Assorted :Wall Fan 67 Assorted :Flood / Street Light Fitting 68 Assorted :100 / 125 / 200 / 250A Mccb 69 Assorted :Switch / Socket / Regulator ( Piano / Modular ) 70 Assorted: Sp / Dp Mcb Upto 63 A 71 Assorted : Sp / Tpn Mcb Db 72 Assorted : Copper Wirewith Insulation 73 Assorted : Ms Conduit 74 Assorted : Gi Box With Modular Plate / Phenolic Sheet 75 Assorted : Al. Conductor Armoured Cable 76 Assorted : Led Batten / Downlighter / Fl. Fitting 77 Assorted : 1X4 / 2X2 Fitting