}

Annual Rate Contract For Repairs Of Lt Control Panels, Voltage Stabilizers And Starters Of Various Capacities By Way Of Replacement Of Components With Allied Works Installed At Various Pumping Stations Under Jal Shakti (Phe) Division Poonch., poonch-Jammu And Kashmir

Public Health Engineering Department has published Annual Rate Contract For Repairs Of Lt Control Panels, Voltage Stabilizers And Starters Of Various Capacities By Way Of Replacement Of Components With Allied Works Installed At Various Pumping Stations Under Jal Shakti (Phe) Division Poonch.. Submission Date for this Tender is 27-03-2024. Electrical Maintenance Tenders in poonch Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

42901298
Annual Rate Contract For Repairs Of Lt Control Panels, Voltage Stabilizers And Starters Of Various Capacities By Way Of Replacement Of Components With Allied Works Installed At Various Pumping Stations Under Jal Shakti (Phe) Division Poonch.
Open Tender
Indian
Jammu And Kashmir
Poonch
27-03-2024

Tender Details

Annual Rate Contract for repairs of LT Control panels, Voltage Stabilizers and Starters of various capacities by way of replacement of components with allied works installed at various pumping stations under Jal Shakti (PHE) Division Poonch. , Disconnection Of Incoming Power Connection From Main Switch / Mccb / Voltage Stabilizer And Checking Of Fault , Making Of Temporary Arrangement For Running Of Pumping Machinery , Replacement Of Damaged Mnx 25 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 25 , Replacement Of Damaged Mnx 45 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 40 , Replacement Of Damaged Mnx 50 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 50 , Replacement Of Damaged Mnx 70 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 70 , Replacement Of Damaged Mnx 80 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 80 , Replacement Of Damaged Mnx 95 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 95 , Replacement Of Damaged Mnx 110 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 110 , Replacement Of Damaged Mnx 140 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 185 , Replacement Of Damaged Mnx 185 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 185 , Replacement Of Damaged Mnx 225 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 225 , Replacement Of Damaged Mnx 250 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 250 , Replacement Of Damaged Kit Of Mnx 25 By Way Of Providing / Fitting Of New Kit , Replacement Of Damaged Kit Of Mnx 45 By Way Of Providing / Fitting Of New Kit , Replacement Of Damaged Kit Of Mnx 50 By Way Of Providing / Fitting Of New Kit , Replacement Of Damaged Kit Of Mnx 70 By Way Of Providing / Fitting Of New Kit , Replacement Of Damaged Kit Of Mnx 80 By Way Of Providing / Fitting Of New Kit , Replacement Of Damaged Kit Of Mnx 95 By Way Of Providing / Fitting Of New Kit , Replacement Of Damaged Kit Of Mnx 110 By Way Of Providing / Fitting Of New Kit , Replacement Of Damaged Kit Of Mnx 140 By Way Of Providing / Fitting Of New Kit , Replacement Of Damaged Kit Of Mnx 185 By Way Of Providing / Fitting Of New Kit , Replacement Of Damaged Kit Of Mnx 225 By Way Of Providing / Fitting Of New Kit , Replacement Of Damaged Kit Of Mnx 250 By Way Of Providing / Fitting Of New Kit , Replacement Of Damaged Kit Of Mnx 45 By Way Of Providing / Fitting Of New Kit , Replacement Of Damaged Kit Of Mnx 50 By Way Of Providing / Fitting Of New Kit , Replacement Of Damaged Coil Of Mnx 70 By Way Of Providing / Fitting Of Coil , Replacement Of Damaged Coil Of Mnx 80 By Way Of Providing / Fitting Of New Coil , Replacement Of Damaged Coil Of Mnx 95 By Way Of Providing / Fitting Of New Coil , Replacement Of Damaged Coil Of Mnx 110 By Way Of Providing / Fitting Of New Coil , Replacement Of Damaged Coil Of Mnx 140 By Way Of Providing / Fitting Of New Coil , Replacement Of Damaged Coil Of Mnx 185 By Way Of Providing / Fitting Of New Coil , Replacement Of Damaged Coil Of Mnx 225 By Way Of Providing / Fitting Of New Coil , Replacement Of Damaged Coil Of Mnx 250 By Way Of Providing / Fitting Of New Coil , Replacement Of Damaged Mpr , Replacement Of Damaged Over Load Relay & P / F New Overload Relay , Replacement Of Damaged Under Load Relay & P / F New Underload Relay , Replacement Of Single Phase Relay & P / Fsingle Phase Relay , Replacement Of Reverse Phase Relay & P / Freverse Phase Relay , Replacement Of Damaged Mccb 100 By Way Of Providing / Fitting Ofmccb 100 Amp , Replacement Of Damaged Mccb 125 By Way Of Providing / Fitting Ofmccb 125 Amp , Replacement Of Damaged Mccb 200 By Way Of Providing / Fitting Ofmccb 200 Amp , Replacement Of Damaged Mccb 250 By Way Of Providing / Fitting Ofmccb 250 Amp , Replacement Of Damaged Mccb 400 By Way Of Providing / Fitting Ofmccb 400 Amp , Replacement Of Damaged Mccb 600 By Way Of Providing / Fitting Ofmccb 600 Amp , Replacement Of Damaged Mccb 100 By Way Of Providing / Fitting Ofmccb 100 Amp , Making Ofincoming Power Connection To Main Switch / Mccb / Voltage Stabilizer And Checking On Full Load. , Upto 100 Amp , Charges For Minor Repair / Servicing Of Lt Control Panel Including Minor Parts Like Meters, Indicators , Timers Etc , Providing / Fitting Ofcircuit Wiring , Providing / Fitting Ofvoltmeter , Providing / Fitting Of Ampmeter , Providing / Fitting Ofamp Selector Switch , Providing / Fitting Ofvolt Selector Switch , Providing / Fitting Ofpush Button , Providing / Fitting Ofindicator Lamps , Providing / Fitting Ofstar Delta Timer , Providing / Fitting Ofterminal Plate , Providing / Fitting Offault Analyzer , Providing / Fitting Ofquartz Timer , Providing / Fitting Ofdelay Timer , Providing / Fitting Ofpower Wiring , Providing / Fitting Ofthermal Overload Relay , Providing / Fitting Ofbus Bar , Providing / Fitting Ofboiled Fuse Link , Providing / Fitting Offuse Holder Suitable For Bolted Fuse Link , Making Ofincoming Power Connection To Main Switch / Mccb / Voltage Stabilizer And Checking On Full Load. , 125 Amp. To 200 Amp , Charges For Minor Repair / Servicing Of Lt Control Panel Including Minor Parts Like Meters, Indicators , Timers Etc , Providing / Fitting Ofcircuit Wiring , Providing / Fitting Ofvoltmeter , Providing / Fitting Of Ampmeter , Providing / Fitting Ofamp Selector Switch , Providing / Fitting Ofvolt Selector Switch , Providing / Fitting Ofindicator Lamps , Providing / Fitting Ofpush Button , Providing / Fitting Ofstar Delta Timer , Providing / Fitting Ofterminal Plate , Providing / Fitting Offault Analyzer , Providing / Fitting Of Quartz Timer , Providing / Fitting Ofdelay Timer , Providing / Fitting Ofpower Wiring , Providing / Fitting Ofthermal Overload Relay , Providing / Fitting Ofbus Bar , Providing / Fitting Ofboiled Fuse Link , Providing / Fitting Offuse Holder Suitable For Bolted Fuse Link , Making Ofincoming Power Connection To Main Switch / Mccb / Voltage Stabilizer And Checking On Full Load. , 225 Amp. To 300 Amp. , Charges For Minor Repair / Servicing Of Lt Control Panel Including Minor Parts Like Meters, Indicators , Timers Etc , Providing / Fitting Ofcircuit Wiring , Providing / Fitting Ofvoltmeter , Providing / Fitting Of Ampmeter , Providing / Fitting Ofamp Selector Switch , Providing / Fitting Ofvolt Selector Switch , Providing / Fitting Ofindicator Lamps , Providing / Fitting Ofpush Button , Providing / Fitting Ofstar Delta Timer , Providing / Fitting Ofterminal Plate , Providing / Fitting Offault Analyzer , Providing / Fitting Ofquartz Timer , Providing / Fitting Ofdelay Timer , Providing / Fitting Ofpower Wiring , Providing / Fitting Ofthermal Overload Relay , Providing / Fitting Ofbus Bar , Providing / Fitting Ofboiled Fuse Link , Providing / Fitting Offuse Holder Suitable For Bolted Fuse Link , Making Ofincoming Power Connection To Main Switch / Mccb / Voltage Stabilizer And Checking On Full Load. , 63 Kva Voltage Stablizer , Rewinding Of Copper Coil , Providing & Fitting Of Rotary Switch As Per Size , Providing & Fitting Of Change Over Switch100 Ampere , Providing & Fitting Of Mccb 100 Ampere , Providing & Fitting Of Indicator , Providing & Fitting Of Selector Switch , Providing & Fitting Of Amperemeter , Providing & Fitting Of Voltmeter , Fresh Transformer Oil Per Litre , Providing & Fitting Of Nut Bolts , Wiring Complete Job With Insultor , Rate Of Old Transformer Oil Per Kg , Disconnecting Of Power Connection Of The Voltage Stabilizer, Dismantling Of Stabilizer By Unscrewing Nut Bolts. Extracting Out Of Stabilizer Coil Structure By Mounting Of Chain Pulley Block With The Help Of Manual Skilled Labour. , Assembling Of Stabilizer, Connecting The Power Connections And Testing On Load. , 100 Kva Voltage Stablizer , Rewinding Of Copper Coil , Providing & Fitting Of Rotary Switch As Per Size , Providing & Fitting Of Change Over Switch250 Ampere , Providing & Fitting Of Mccb 250 Ampere , Providing & Fitting Of Indicator , Providing & Fitting Of Selector Switch , Providing & Fitting Of Amperemeter , Providing & Fitting Of Voltmeter , Fresh Transformer Oil Per Litre , Providing & Fitting Of Nut Bolts , Wiring Complete Job With Insultor , Rate Of Old Transformer Oil Per Kg , Disconnecting Of Power Connection Of The Voltage Stabilizer, Dismantling Of Stabilizer By Unscrewing Nut Bolts. Extracting Out Of Stabilizer Coil Structure By Mounting Of Chain Pulley Block With The Help Of Manual Skilled Labour. , Assembling Of Stabilizer, Connecting The Power Connections And Testing On Load. , 150 Kva Voltage Stablizer , Rewinding Of Copper Coil , Providing & Fitting Of Rotary Switch As Per Size , Providing & Fitting Of Change Over Switch250 Ampere , Providing & Fitting Of Mccb 250 Ampere , Providing & Fitting Of Indicator , Providing & Fitting Of Selector Switch , Providing & Fitting Of Amperemeter , Providing & Fitting Of Voltmeter , Fresh Transformer Oil Per Litre , Providing & Fitting Of Nut Bolts , Wiring Complete Job With Insultor , Rate Of Old Transformer Oil Per Kg , Disconnecting Of Power Connection Of The Voltage Stabilizer, Dismantling Of Stabilizer By Unscrewing Nut Bolts. Extracting Out Of Stabilizer Coil Structure By Mounting Of Chain Pulley Block With The Help Of Manual Skilled Labour. , Assembling Of Stabilizer, Connecting The Power Connections And Testing On Load. , 200 Kva Voltage Stablizer , Rewinding Of Copper Coil , Providing & Fitting Of Rotary Switch As Per Size , Providing & Fitting Of Change Over Switch400 Ampere , Providing & Fitting Of Mccb 400 Ampere , Providing & Fitting Of Indicator , Providing & Fitting Of Selector Switch , Providing & Fitting Of Amperemeter , Providing & Fitting Of Voltmeter , Fresh Transformer Oil Per Litre , Providing & Fitting Of Nut Bolts , Wiring Complete Job With Insultor , Rate Of Old Transformer Oil Per Kg , Disconnecting Of Power Connection Of The Voltage Stabilizer, Dismantling Of Stabilizer By Unscrewing Nut Bolts. Extracting Out Of Stabilizer Coil Structure By Mounting Of Chain Pulley Block With The Help Of Manual Skilled Labour. , Assembling Of Stabilizer, Connecting The Power Connections And Testing On Load. , 250 Kva Voltage Stablizer , Rewinding Of Copper Coil , Providing & Fitting Of Rotary Switch As Per Size , Providing & Fitting Of Change Over Switch400 Ampere , Providing & Fitting Of Mccb 400 Ampere , Providing & Fitting Of Indicator , Providing & Fitting Of Selector Switch , Providing & Fitting Of Amperemeter , Providing & Fitting Of Voltmeter , Fresh Transformer Oil Per Litre , Providing & Fitting Of Nut Bolts , Wiring Complete Job With Insultor , Rate Of Old Transformer Oil Per Kg , Disconnecting Of Power Connection Of The Voltage Stabilizer, Dismantling Of Stabilizer By Unscrewing Nut Bolts. Extracting Out Of Stabilizer Coil Structure By Mounting Of Chain Pulley Block With The Help Of Manual Skilled Labour. , Assembling Of Stabilizer, Connecting The Power Connections And Testing On Load. , Oil Immersed Start Delta Starter , Repair Of Star Delta Oil Immersed Starter Upto 20Hp Capacity By Way Of Replacement Of Damaged Contact Points, No Load Coil, Contact Point Holders , Replacement Of T Oil And Testing. , Repair Of Star Delta Oil Immersed Starter Upto 30Hp Capacityby Way Of Replacement Of Damaged Contact Points, No Load Coil, Contact Point Holders , Replacement Of T Oil And Testing. , Repair Of Star Delta Oil Immersed Starter Upto 40Hp Capacityby Way Of Replacement Of Damaged Contact Points, No Load Coil, Contact Point Holders , Replacement Of T Oil And Testing. , Repair Of Star Delta Oil Immersed Starter Upto 50Hp Capacityby Way Of Replacement Of Damaged Contact Points, No Load Coil, Contact Point Holders , Replacement Of T Oil And Testing. , Repair Of Star Delta Oil Immersed Starter Upto 60Hp Capacityby Way Of Replacement Of Damaged Contact Points, No Load Coil, Contact Point Holders , Replacement Of T Oil And Testing. , Repair Of Star Delta Oil Immersed Starter Upto 70Hp Capacityby Way Of Replacement Of Damaged Contact Points, No Load Coil, Contact Point Holders , Replacement Of T Oil And Testing. , Repair Of Star Delta Oil Immersed Starter Upto 80Hp Capacityby Way Of Replacement Of Damaged Contact Points, No Load Coil, Contact Point Holders , Replacement Of T Oil And Testing. , Repair Of Star Delta Oil Immersed Starter Upto 100Hp Capacityby Way Of Replacement Of Damaged Contact Points, No Load Coil, Contact Point Holders , Replacement Of T Oil And Testing. , Repair Of Star Delta Oil Immersed Starter Upto 125Hp Capacityby Way Of Replacement Of Damaged Contact Points, No Load Coil, Contact Point Holders , Replacement Of T Oil And Testing. , Repair Of Star Delta Oil Immersed Starter Upto 125-150Hp Capacityby Way Of Replacement Of Damaged Contact Points, No Load Coil, Contact Point Holders , Replacement Of T Oil And Testing. , Providing And Laying Of Earthing Of Electro Mechanical Machinery ( Transformer / Motors / Lt Panels / Voltage Stablizer ) , Carriage / Shifting Of 100 Kva Voltage Stabilzer From Pump Room On Head Load To And Fro Up To Stacking Place On Road Side With Loading / Unloading Charges , Carriage / Shifting Of 63 Kva Voltage Stabilzer From Pump Room On Head Load To And Fro Up To Stacking Place On Road Side With Loading / Unloading Charges , Carriage / Shifting Of 50 Kva Voltage Stabilzer From Pump Room On Head Load To And Fro Up To Stacking Place On Road Side With Loading / Unloading Charges , Carriage / Shifting Of 200 / 250 Kva Voltage Stabilzer From Pump Room On Head Load To And Fro Up To Stacking Place On Road Side With Loading / Unloading Charges

Key Value

Document Fees
INR 1000 /-
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail