Carrying Out Various Electric Works On Semi Turn Key Basis For System Strengthening In Municipal Area In The Area Of Ee, Eudd I, Ii, Iii, Mathura Under The Jurisdiction Of Se, Eudc, Mathura- 1 Cartage Of Following Material From Store Centre, Mathura To Work Site. 2 St Pole ( 11 Mtr. Long ) ( Bottom Portion Galvanized ) 3 8.5 Mtr. Long Pcc Pole 4 11 / 0.43 Kv 400 Kva T / F 5 11 / 0.43 Kv 250 Kva T / F. 6 Lt Aerial Bunch Conductor 3X120sqmm. 7 Aluminium Armoured Cable 2X10 Sq.Mm. 8 Aluminium Armoured Cable 4X10 Sq.Mm. 9 Aluminium Armoured Cable 4X25 Sq.Mm. 10 Lt Al. Xlpe Cable 1X400 Sq.Mm. 11 Lt Al. Xlpe Cable 1X240 Sq.Mm. 12 Lt Al. Xlpe Cable 1X630 Sq.Mm. 13 Lt Al. Xlpe Cable 1X1000 Sq.Mm. 14 Lt Pvc Cable 1X400 Sq.Mm. 15 Lt Pvc Cable 3.5X70 Sq.Mm. 16 Lt Pvc Cable 3.5X150 Sq.Mm. 17 Lt Pvc Cable 3.5X240 Sq.Mm. 18 Lt Al. Xlpe Cable 3.5X240 Sq.Mm. 19 33 Kv Xlpe Cable 3X300 Sq.Mm. 20 33 Kv Xlpe Cable 3X120 Sq.Mm. 21 11 Kv Xlpe Cable 3X185 Sq.Mm. 22 33 Kv Line Isolator 23 33 Kv Bus Isolator 24 33 Kv 3X300 Sq.Mm. Outdoor Type Cable Jointing Kit 25 33 Kv 3X120 Sq.Mm. Outdoor Type Cable Jointing Kit 26 11 Kv 3X185 Sq.Mm. Outdoor Type Cable Jointing Kit 27 Distribution Box 28 11 Kv Pin Insulator With Pin 29 33 Kv Pin Insulator With Pin 30 11 Kv Disc. Insulator With Fitting 31 11 Kv Fuse Set 32 11 Kv V Type Steel Cross Arm 33 Acsr Dog Conductor 34 Acsr Weasel Conductor 35 Acsr Ins. Weasel Conductor 36 Stay Complete 37 Stay Wire 38 Cartage Of Above Material Like Various Size St / Pcc Poles, Distribution T / F. 33 Kv, 11 Kv, Lt Cable, Dog / Weasel Conductor, Jointing Kit, Insulator, Pin Insulator, Channel, Clamps Etc. From Store Center, Mathura To Work Site And Dismentled Material From Site To Dvvnl Store. 39 Digging Of Pit & Erection Of New Single Support St Pole ( 13 / 11 Mtr. Long ) Including Grouting Of Pole And Fixing Of All Clamps, Cross Arm, Pin / Disc Insulator & Other Accessories With Providing Stone Pad As Per Relevant Drawings. Any Fabrication If Required For Above Support. 40 Digging Of Pit & Erection Of New Single Support Pcc Pole ( 8.5 Mtr. Long ) Including Grouting Of Pole And Fixing Of All Clamps, Cross Arm, Pin / Disc Insulator & Other Accessories With Providing Stone Pad As Per Relevant Drawings. Any Fabrication If Required For Above Support. 41 Digging Of Pit & Erection Of New Double Pole Structure St Pole ( 13 / 11 Mtr. Long ) Including Grouting Of Pole And Fixing Of All Sturucture Accessories, Clamps, Cross Arm, Pin / Disc Insulator & Other Accessories With Providing Stone Pad As Per Relevant Drawings. Any Fabrication If Required For Above Support. 42 Providing & Fixing Of Ms Top Channel 125X65x2240 Mm. 43 Providing & Fixing Of Ms Top Channel 125X65x3200 Mm. 44 Providing & Fixing Of Ms Dropper Channel 100X50x2028mm. 45 Providing & Fixing Of Ms Dropper Channel For 33 Kv 46 Providing & Fixing Of Ms Tee-Off Channel 47 Providing & Fixing Of Clamp For Tee-Off Channel 48 Providing & Fixing Of Ms Angle Iron 65X65x6mm, 4300 Mm Long Bracing With 4 No. Clamp 49 Providing & Fixing Of Ms Angle Iron 65X65x6mm, 2700 Mm Long Bracing With 4 No. Clamp 50 Laying Of Acsr Dog Conductor 51 Laying Of Acsr Weasel Conductor 52 Laying Of Ins. Weasel Conductor 53 Earthing Of St / Pcc Pole / Body Earthing Of T / F. 54 Installation & Fixing Of 33 Kv Line Isolator 55 Installation & Fixing Of 33 Kv Bus Isolator 56 Providing & Fixing Of G.I. Dipped Structure For 33 Kv Line Isolator & Bus Isloator 57 Providing & Fixing Transformer Bushing Boots For Safety The Cable Terminal ( 11 Kv ) ( 03 Nos. In 01 Set ) 58 Supply & Erection Of Insulating Tape / Heat Shrinkable Rubber Slip For Lt Bushing ( 1.1 Kv ) With Complete Covering 59 Providing & Fixing Wooden Packing 60 Providing & Fixing Of 33 Kv Main Bus Bar With G.I. Dipped Structure 61 Supply And Replacement Of 1.1 Kv Heat Shrinkable State Through Joint Kit Of Diffrent Sizes Cableslike 50 Sq Mm 3.5, 4 Corealuminium Armored Xlpe Cable Make: 3M / Rechem 62 Supply And Replacement Of 1.1 Kv Heat Shrinkable State Through Joint Kit Of Diffrent Sizes Cableslike 70 Sq Mm 3.5, 4 Corealuminium Armored Xlpe Cable Make: 3M / Rechem 63 Supply And Replacement Of 1.1 Kv Heat Shrinkable State Through Joint Kit Of Diffrent Sizes Cableslike 120 Sq Mm 3.5, 4 Corealuminium Armored Xlpe Cable Make: 3M / Rechem 64 Supply And Replacement Of 1.1 Kv Heat Shrinkable State Through Joint Kit Of Diffrent Sizes Cableslike 240 Sq Mm 3.5, 4 Corealuminium Armored Xlpe Cable Make: 3M / Rechem 65 Supply & Fixing Of Empty Panel Boxes & Covers Of C Panel Along With Mounting Structureand Its Installation By Grouting & Plinthing Of Structure In Aspect Ratio Of 1:4:8 Cement:Sand:Concrete , 300X300x800 Mm Size Concrete Of Each Legs. ( For C Type 0.288 Cum For 4 Legs ) . 66 Supply & Fixing Of Empty Pannel Boxes Cover For C Panel With Hinges & Lock Hook ( Suitable For Existing Panel Installed At Various Site ) 67 Supply & Fixing Of Empty Pannel Boxes Cover For B-1, B-2, B-3 Front And Back Panel Cover With Hinges & Lock Hook ( Suitable For Existing Panel Installed At Various Site ) 68 Supply & Fixing Of Empty Pannel Boxes Cover For A-1, A-2, A-3, A-5Front And Back Panel Cover With Hinges & Lock Hook ( Suitable For Existing Panel Installed At Various Site ) 69 Supply & Fixing Of Ats Switch ( 400 Amp. ) With Mounting Structure & Controller & Suitable Box Of 02 Mm Thickness Crca Panel With Retro Fitting In Existing Panel. 70 Laying Of 3X120 Sqmm. Ab Conductor For Lt Line On Erected Poles. 71 Laying Of Aluminium Armoured Cable 2X10sq.Mm. 72 Laying Of Aluminium Armoured Cable 4X10 Sq.Mm. 73 Laying Of Aluminium Armoured Cable 4X25 Sq.Mm. 74 Providing & Fixing Of G.I. Pipe 50Mm Dia 75 Providing & Fixing Of G.I. Pipe 6 Dia 76 Providing & Fixing Of G.I. Pipe Clamp 77 Providing & Fixing Of G.I. Wire 78 Providing & Fixing Of Pvc Pipe 2 Dia 79 Providing & Fixing Of Pvc Pipe 3 Dia 80 Providing & Fixing Of Al. Thimble 10Sqmm. 81 Providing & Fixing Of Al. Thimble 16Sqmm. 82 Providing & Fixing Of Aluminium Binding Wire 6 Swg 83 Fixing Of 11 Kv Disc Insulator With Fitting 84 Providing & Fixing Holding Clamp For Cross Arm 85 Providing & Fixing Of Dead End Clamp With I Hook 86 Providing & Fixing Of Suspension Clamp With I Hook 87 Providing & Fixing Of Piercing Clamp 88 Stay Complete With Concreting 89 Laying Of Stay Wire 90 Providing & Fixing Stay Clamp 91 Concreting Of Pole ( Stp 13 Mtr. / 11 Mtr. ) Pcc Pole 92 Painting Of St Pole With Red Oxide 93 Providing & Fixing Of Danger Board 94 Providing & Fixing Of Barbed Wire 95 Providing & Fixing Of Stone Pad 96 Providing & Fixing Of P.G. Clamp 97 Providing & Fixing Number Plate 98 Fixing Of 11 Kv V Type Steel Cross Arm 99 Fixing Of 11 Kv Pin Insulator With Pin 100 Fixing Of 33 Kv Pin Insulator With Pin 101 Installation Of Distribution Box 102 Providing & Fixing Clamp For Distribution Box 103 Providing & Fixing Ms Nut, Bolt & Washer 104 Providing & Fixing Holding Clamp With Nut & Bolt 105 Providing & Fixing 10 Mm Aluminium Lugs 106 Providing & Fixing 25 Mm Aluminium Lugs 107 Providing & Fixing 70 Mm Aluminium Lugs 108 Providing & Fixing 150 Mm Aluminium Lugs 109 Providing & Fixing 240 Mm Aluminium Lugs 110 Providing & Fixing 400 Mm Aluminium Lugs 111 Providing & Fixing 630 Mm Aluminium Lugs 112 Providing & Fixing 1000 Mm Aluminium Lugs 113 Providing & Fixing Of Cable End Termination Using Total Double Compression Brass Glands For 3.5X70 Sq.Mm. Xlpe Cable 114 Providing & Fixing Of Cable End Termination Using Total Double Compression Brass Glands For 3.5X150 Sq.Mm. Xlpe Cable 115 Providing & Fixing Ofcable End Termination Using Total Double Compression Brass Glands For 3.5X240 Sq.Mm. Xlpe Cable 116 A-1 Type Distribution Panelincomming :- 1250 Amp. Acb ( Fp ) Outgoing :-400 Amp. 04 Nos., 250 Amp. 02 Nos. Mccb Tpswitchgear Make : Scheinder / Abb / Siemens / L&T.Supply &Erectionofelectrical Control Panel For Outdoor Application With Incoming Acb Having Short Circuit And Earth Fault Protection And Outgoing MccbSshall Be Tp Type With Extended Rotary Handel, Spreader Sets And Phase Barriers.The Switch Board Panel Shall Be Fabricated With 2 Mm Sheet Thickness, Double Door Type, Floor Mounting Base Channel With Detachable Gland Plate And Seprate Incoming Chamber As Well As Metering Chamber With Digital Multi Function Meter, Instrument Fuses, Current Transformer And Phase Indicators, Cable Allay Section With Proper Horizontal / Vertical Bus Bar Etc Complete In All Respect.The Jobincludesthe Disconnection, Dismantling And Replacement Of Burn Cables Ends And Joints Enclosure Etcof A-1 Type Existing Panel As Per The Direction Of Engineer In-Charge. 117 A-2 Type Distribution Panelincomming :- 800 Amp. Acb ( Fp ) Outgoing :- 400 Amp. 02 Nos., 250 Amp. 02 Nos. Mccb Tpswitchgear Make : Scheinder / Abb / Siemens / L&T.Supply &Erectionofelectrical Control Panel For Outdoor Application With Incoming Acb Having Short Circuit And Earth Fault Protection And Outgoing MccbSshall Be Tp Type With Extended Rotary Handel, Spreader Sets And Phase Barriers.The Switch Board Panel Shall Be Fabricated With 2 Mm Sheet Thickness, Double Door Type, Floor Mounting Base Channel With Detachable Gland Plate And Seprate Incoming Chamber As Well As Metering Chamber With Digital Multi Function Meter, Instrument Fuses, Current Transformer And Phase Indicators, Cable Allay Section With Proper Horizontal / Vertical Bus Bar Etc Complete In All Respect.The Jobincludesthe Disconnection, Dismantling And Replacement Of Burn Cables Ends And Joints Enclosure Etcof A-2 Type Existing Panel As Per The Direction Of Engineer In-Charge. 118 A-3 Type Distribution Panelincomming :- 630 Amp. Acb ( Fp ) Outgoing :-250 Amp. 04 Nos. Mccb Tpswitchgear Make : Scheinder / Abb / Siemens / L&T.Supply &Erectionofelectrical Control Panel For Outdoor Application With Incoming Acb Having Short Circuit And Earth Fault Protection And Outgoing MccbSshall Be Tp Type With Extended Rotary Handel, Spreader Sets And Phase Barriers.The Switch Board Panel Shall Be Fabricated With 2 Mm Sheet Thickness, Double Door Type, Floor Mounting Base Channel With Detachable Gland Plate And Seprate Incoming Chamber As Well As Metering Chamber With Digital Multi Function Meter, Instrument Fuses, Current Transformer And Phase Indicators, Cable Allay Section With Proper Horizontal / Vertical Bus Bar Etc Complete In All Respect.The Jobincludesthe Disconnection, Dismantling And Replacement Of Burn Cables Ends And Joints Enclosure Etcof A-3 Type Existing Panel As Per The Direction Of Engineer In-Charge. 119 B-1 Type Distribution Panel With Motrised Change Over Switch 400 Amp. & Ats Control System.Incomming :- 400 Amp. Mccb ( Fp ) Outgoing :-250 Amp. 03 Nos. Mccb Tp & 160 Amp. 02 Nos. Mccb Tp.Switchgear Make : Scheinder / Abb / Siemens / L&T.Supply &Erectionofelectrical Control Panel For Outdoor Application With Incoming And Outgoing MccbSshall Be With Extended Rotary Handle, Spreader Sets And Phase Barriers.The Switch Board Panel Shall Be Fabricated With 2 Mm Sheet Thickness, Double Door Type, Floor Mounting Base Channel With Detachable Gland Plate And Seprate Incoming Chamber As Well As Metering Chamber With Digital Multi Function Meter, Instrument Fuses, Current Transformer And Phase Indicators, Cable Allay Setion With Proper Horizontal / Vertical Bus Bar Etc Complete In All Respect.The Jobincludesthe Disconnection, Dismantling And Replacement Of Burn Cables Ends And Joints Enclosure Etcof B-1 Type Existing Panel As Per The Direction Of Engineer In-Charge. 120 B-2 Type Distribution Panel With Motrised Change Over Switch 250 Amp. & Ats Control System.Incomming :- 250 Amp. Mccb ( Fp ) Outgoing :-125 Amp. 05 Nos. Mccb Tp.Switchgear Make : Scheinder / Abb / Siemens / L&T.Supply &Erectionofelectrical Control Panel For Outdoor Application Wiht Incoming And Outgoing MccbSshall Be With Extended Rotary Handle, Spreader Sets And Phase Barriers.The Switch Boar Panel Shall Be Fabricated With 2 Mm Sheet Thickness, Double Door Type, Floor Mounting Base Channel With Detachable Gland Plate And Seprate Incoming Chamber As Well As Metering Chamber With Digital Multi Function Meter, Instrument Fuses, Current Transformer And Phase Indicators, Cable Allay Setion With Proper Horizontal / Vertical Bus Bar Etc Complete In All Respect.The Jobincludesthe Disconnection, Dismantling And Replacement Of Burn Cables Ends And Joints Enclosur Etcof B-2 Type Existing Panel As Per The Direction Of Engineer In-Charge. 121 C Paneldisconeccting And Dismentlingof Existing C Panel And Supply, Installation Testing Commisioning Offactory Fabricated&Wired Metalcladdustandverminproof Double Door Typeoutdoor Application Stand Mounting.M.S. Channel Base Incliding Channel Stand With Bottom Cable Entreis The Panel Boardshall Havesuitablecapacity Electrolytic Alumininum Busbars Asper Is8623 Or Above Istulated With Heat Shrink Sleeving And Mounted On Nonhygroscopic Supports Such As Cmc / Bmc Support. Panel Shall Be Completewithsuitablecableendboxes, Double Compression Glands. Panel Comparment Having Special Provision For Internal Locking System For Stop The Electricity Theft The Panelboard Shall Be Fabricated With A Minimum Thickness 2 Mm. With Seven Tank Process Powder Coated. Panel Haveing Proper Space For Connectingincomming And Outgoing Cable Terminations. 122 Earthing Of C Type Lt Panel By Earth Rod 123 Digging Of Trench By Making Pits / Open Trench Method After Due Survey With The Help Of Utility Detector Of Existing Electrical / Telephonic Cable / And Other Utilites Of Public Utilites Departmentand Laying, Testing, Commisiong & Energization Of 33 Kv Xlpe Cable Of Size 3X300 Sqmm. Xlpe By Open Trench Including All Material Like Brick & Sand And Back Filling And Proper Dresing. 124 Digging Of Trench By Making Pits / Open Trench Method After Due Survey With The Help Of Utility Detector Of Existing Electrical / Telephonic Cable / And Other Utilites Of Public Utilites Departmentand Laying, Testing, Commisiong & Energization Of 11 Kv Xlpe Cable Of Size 3X185 Sqmm. Xlpe By Open Trench Including All Material Like Brick & Sand And Back Filling And Proper Dresing. 125 Laying Of Lt Al. Xlpe Cable 1X400 Sq.Mm. 126 Laying Of Lt Al. Xlpe Cable 1X240 Sq.Mm. 127 Laying Of Lt Al. Xlpe Cable 1X630 Sq.Mm. 128 Laying Of Lt Al. Xlpe Cable 1X1000 Sq.Mm. 129 Laying Of Lt Pvc Cable 3.5X70 Sq.Mm. 130 Laying Of Lt Pvc Cable 3.5X150 Sq.Mm. 131 Laying Of Lt Pvc Cable 3.5X240 Sq.Mm. 132 Laying Of Lt Pvc Cable 1X400 Sq.Mm. 133 Laying Of Lt Xlpe Cable 3.5X240 Sq.Mm. 134 Laying Of 33 Kv, 3X300 Xlpe Cable Air On Double Pole Structure & Filling Of Cable Joint Kit With Proper Dressing. 135 Laying Of 33 Kv, 3X120 Xlpe Cable Air On Double Pole Structure & Filling Of Cable Joint Kit With Proper Dressing. 136 Laying Of 11 Kv, 3X185 Xlpe Cable Air On Double Pole Structure & Filling Of Cable Joint Kit With Proper Dressing. 137 Filling & Fixing Of Outdoor Type Cable Jointing Kit For 33 Kv 3X300 Sqmm. Xlpe Cable 138 Filling & Fixing Of Outdoor Type Cable Jointing Kit For 33 Kv 3X120 Sqmm. Xlpe Cable 139 Filling & Fixing Of Outdoor Type Cable Jointing Kit For 11 Kv 3X185 Sqmm. Xlpe Cable 140 Installation Of 11 Kv Fuse Set 141 Providing And Fabrication Of 33 Kv G.I. Dipped Terminal Gantry With Complete Accessories 142 The Construction Of New Plinth Of Size 6’X6’X4’ Aboveground Level And One Ft. Below The Ground Level For 400 / 250 Kva Transformer 143 Installation Of Following Transformer On Plinth / Double Pole With All Connecting Accessories Jumering Etc. Including Carriage Of Transformers From Store Centre, Mathura To Work Site. 144 400 Kva Transformer On Plinth 145 250 Kva Transformer On Plinth 146 Construction Of M.S Angle Fencing Of Size ( 3M X3m X2m ) Around The Plinth Of 400 / 250 Kva Transformer And Gap Between The M.S Angle Should Not Be More Than 65Mm. 147 Complete Gel Earthingof 11 / 0.4 Kv 250 / 400 Distribution Transformer, Various A-Type & B-Type Lt Panel By Digging Pits 6” Dia Upto 3 Mtr. Deep Including Chemical Filled Pipe In Between ( Pipe-In-Pipe ) Isi Mark B Grade & Connecting With G.I Strip Of Size 50Mm X 6Mm With Neutral / Body Of 11 / 0.4 Kv Distribution Transformer To Above Pipe-In-Pipe ( Pip ) And Filling Of Chemical Crystalline Conductive Mixture Containing Highly Conductive Material Around The ( Pipe-In-Pipe ) Up To 3 Mtr. Including Making Of Chamber At The Top Of The Earthing. Other Details Are As Below:-1.Earth Pipe Material – Mild Steel, Galvanised.2-Main Electrode Diameter – 42.4Mm.3-Auxiliary Electrode Pipe, Diameter – 76Mm.4-Wall Thickness Of Main Electrode :- 2.6Mm.5-Wall Thickness Of Auxiliary Ist Whole:- 3.2Mm.6- Length Of Earthing Electrode ( Pip ) :- 3 Meter. 148 Control Room Extension ( All Materaial Like Brick, Sand, Cement, Concrete, Tmt Bar, Etc Will Be Provided By Contractor ) 149 Cartage Of Old Existing T / F. With Other Required Accessories, Old & Damaged Lt Panel, Lt Line With Associated Infra / Scrap, Lt Ab Conductor From Work Site To Store Center, Mathura 150 Proper Road Restoration Pucca ( If Required ) Rates Shall Be Acceptable, If Not Given Above For The Same Work. 151 Proper Road Restoration Kaccha ( If Required ) Rates Shall Be Acceptable, If Not Given Above For The Same Work.