| 1 | Excavation in any type of soil/road in trenches of size n. exc 1.5M wide & n.exc 1.5M in depth for laying of cable including removal of bricks, tiles laid in cable trench & getting out for repairs to cable in trench at different locations in hard dense soil including in the cable laying way at different locations, as directed. |
| 2 | Demolition of cement concrete in ground floors & pavings, below or above ground level where directed. |
| 3 | Supply and filling Sand under floors/cable trenches for cable protection at specific location or in foundations including consolidation, as directed |
| 4 | Supply and laying of sub-class \"B\" modular bricks, laid dry over straight or curved sutface for cable inside the trenches for protection of cables or as directed. |
| 5 | returning, Refilling in, including spreading, levelling and consolidation of earth in layers not exceeding 0.25M thick in the cable trench of size n.exc. 1.5M wide & n.exc. 1.5M depth or as directed, at different locations . |
| 6 | Supply and laying un-raeinforced precast concret cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40 mm |
| 7 | Supply and laying of 100mm dia galvanised steel, medium grade pipe with ISI mark with all fittings to be laid in trenches or as directed. |
| 8 | Supply and laying of 50mm dia bore of galvanised steel, medium grade pipe with ISI mark with all fittings to be laid in trenches or as directed. |
| 9 | Supply of GI pipe 25 mm dia with ISI mark on it, for cable passing through it for protection of cable at electric pole, laid in tenches, road crossing or as directed. |
| 10 | Supply and laying or fixing or passing through pipe1100 volts grade heavy duty cable with PVC insulated, stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed, 4 core 10 sq.mm conductor size cable, including both end termination with proper glanding & lugging in junction box or pole box or as directed. |
| 11 | Supply and laying or fixing or passing through pipe1100 volts grade heavy duty cable with PVC insulated, stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed, 4 core 25 sq.mm conductor size cable, including both end termination with proper glanding & lugging in junction box or pole box or as directed. |
| 12 | supply and Providing PCC work across road crossing in the trenches and others as to making good disturb surfaces, road etc. including with grouting/ making of foundation with proper curing with mixof type C2-1:3:6 with 40mm graded aggregate etc. complete all as per directed. |
| 13 | Laying of HT/LT cable PVC insulated & PVC sheathed/XLPE power cable of size up to 35 sqmm in the existing trench as required. |
| 14 | Laying of HT/LT cable PVC insulated & PVC sheathed /XLPE power cable of size 95 to 185 sqmm in the existing trench as required. |
| 15 | Laying of HT/LT cable PVC insulated & PVC sheathed /XLPE power cable above of size 185 to 400 sqmm in the existing trench as required. |
| 16 | Supply and fixing cable rout marker with 10cmX10cmX5mm thick G.I plate with inscription there on LT / HT as required, bolted/welded to 35mm X 35mm X 6mm angle iron, 1m long and fixing / growting with concrete the same in ground as required. |
| 17 | Supply and making straight through cable jointing with heat shrinkable jointing kit complete with Jointing material and accessaries suitable for3 core, size 240 sq.mm, XLPE armoured aluminium conductor cable of 11 KV(E) grade cable. |
| 18 | Supply and making cable end termination forindoor termination with heat shrinkable jointing kit complete with jointing materials and all accessories including connection arrangemens (Lugs,SS bolts, nuts and washers, extension copper strips, earthing connection arrangement etc.)suitable for 11 kV(E) grade3 core, 240 sq.mm XLPE armoured aluminium conductor cable with connection inside the 11KV panel or as directed. |
| 19 | Supply and laying of 150mm dia galvanised steel, medium grade pipe with ISI mark with all fittings to be laid in trenches or as directed. |
| 20 | Supply, connection and commisioning / testing of 33 kV, 150 sq.mm HT three core alluminium conductor, XLPE insulated, armoured cable as per IS, Make Polycab, Havells, Finolex, Gloster or equivalent |
| 21 | Supply and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules, suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade 150 sqmm cable. |
| 22 | Supply and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including connection arrangemens (Lugs,SS bolts, nuts and washers, extension copper strips, earthing connection arrangement etc. as required)suitable for 33 kV 3 core, 150 sq.mm XLPE aluminium cable. |
| 23 | Supplying and fixingwith connection of 1100 volts grade heavy duty cable PVC insulated aluminium conductor cross section area 4 Sq.mm, twin core cable circular, served with inner sheathing of PVC tape and overall PVC sheathed for connection from pole junction box to street light fiting including earthing GI wire 4mm with proper clamping, clitting, saddling, passing through pipe with fixing of pipe at pole by 2 Nos. MS clamp and providingflexible metal pipe as required up to the light fitthing connection point for covering of loose cables or as directed. |
| 24 | Supply and fixing of Street light pole junction box 3 Phase& neutral 415V AC made of CRCA sheet steel 2 mm thick, size of box not less than 225 mm(L) x 210mm (W) x 110 mm (D), box enclosure should be water and vermin proof. Door having locking arrangement with mushroom head bolt at one end and other end fixed with hinged with proper gasketing for door closing & protection. Box should have water protection shade at the top and projected at the door. pole boxes comprises with \"clip on type nylon/ PVC connector suitable for 10 sq.mm to 25 sq.mm size conductor of cable, fixed on din rail- 12 Nos., 6 Amps MCB fixed on din rail -1 No., cable gland brass nickel coated suitable for 4x10 Sq.mm and 4x25 Sq.mm armoured Al. conductor cable as per requirement, fixed at bottom of box on detachable gland plate - 02 Nos.\"cable entry at the bottom of box, 2 Nos. earthing connections points shall be provided at box out side. One No. cable entry hole at the bottom of box must be providedwith suitable rubber ring/ bushing for entry of 4 Sq.mm twin core round Al cable for connecting light fitting luminare on the pole. Clamp for fixing of box on the RCC pole made with iron strip size : 30mm width, 3 mm thick and suitable length with suitable size of nut, bolt and washers, Inclusive of one primer coat, one under coat and one finishing coat of smoke gray paint inside and out side ofpole box and clamps etc. |