Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-03-2024 | Corrigendum | Technical Bid | 29-03-2024 |
| Sl. No. | Item Description |
| 1 | Implants List |
| 2 | DHS set*barrel length 38mm,25 mm SS lag screw 22 & 16 mm tread (50 to 115mm in 5mm increment) and top screw & angle 125 to 140 degree plate 3 hole to 18 hole & corresponding4.5 mm screw for plate |
| 3 | Pediatric D.H.S. Set SS |
| 4 | D.C.S set* 95 degree Plate bareel length 38/25mm with lag screw12.5/8mm from 50 to 115mm and top screw and plate length 4 hole to 24 hole SS4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20, 22, 24 holesNote:- 1.The implants listed from Item No. 1 to 3 set include plate,lag screw,top screw and screw for plate so price quotation should be given accordingly2.The implants listed from Item No. 1 to 3 should be supplied along with all the instruments required for insertion (for which no extra charges/rent will be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between theimplant-instrument fitting. |
| 5 | Angle Blade Plateset (950) SSBlade size 50, 55, 60, 65, 70 & 75 mm.plate hole4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18 holes with screw for respective plate |
| 6 | Condylar Buttress Plate with screw ss3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 HolesNote:- The implants listed from Item No. 4 to 5 should be supplied along with the Specific instrumentation required for their insertion (for which no extra charges/rent will be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between the implant- instrument fitting. |
| 7 | Trochanteric Stabilisation Plate to be used with DHS & PFN of varius hole with screw and instrument |
| 8 | Contoured Locking Plate for Fracture shaft femur 4.5 mm (Right & Left)- as per AO specifications. 3, 5, 7, 9, 13, (Combi holes) with corresponding screw SS |
| 9 | Distal Femur Locking Compression Plate 4.5mm (Right & Left) 4 hole to 18 hole with correspondingscrew SSAnatomical pre-shaped & Contoured with self-tapping Locking Head Screws; with Round Locking Holes for metaphyseal portion of plate & Combiholes for shaft of plate.should be supplied along with the Specific instrumentation required for their insertion (for which no extra charges/rent will be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between the implant- instrument fitting. |
| 10 | Medial & Lateral Proximal Tibial Buttress PlateRt & Lt (T- & L- shape)- as per AO specifications. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes with corresponding screw SS |
| 11 | Proximal Medial Tibial Plate 3.5 mm Rt & Lt with corresponding screw SS1. Anatomically pre shaped and low profile.2. Two different plate design for left and right side with indication on side of plate.3. Plate should have 2 mm holes for Proximal Fixation with k-wire and sutures for meniscal repair.4. Holes should accept 3.5 mm locking head or 3.5 mm Standard Cortical Screws from 4 to 20 holes with increment of 2 holes. |
| 12 | Proximal Lateral Tibial Locking Plate for 4.5 mm screws Rt & Lt with corresponding screw SS1. Anatomically pre shaped and low profile design, two different plate design for left and right with indication on plate.2. Round metaphyseal locking holes and combi holes in shaft portion for locking and standard screws.3. Different angulation in proximal part of the plate to avoid primary and secondary loss of reduction.4. Should be compatible for less invasive technique.5. Holes should accept 5 mm locking head or 6.5 mm standard cancellousl screws from 5 to 13 holes |
| 13 | L C P 3.5 mm Proximal Lateral Tibial Plate Rt & Lt with corresponding screw SS1. Anatomically pre shaped and low profile,.plate should have three to four 2 mm holes in most proximal part for fixation with k-wire and suture .2. Should have holes for four convergent 3.5 mm locking screws designed to allow locking screws to support medial fragment,plate design should allow screws in head of the plate to support the subchondral bone.3. Shaft portion should have combi holes to accept 3.5 mm locking head screws and3.5 mm standard cortical screw.4. Should be available in left and right sides with 4 to 16 holes with 2 hole increaments |
| 14 | posteromedial anatomicalproximal tibia plate 3.5mm wth corresponding screw1. Anatomically pre shaped and low profile.2. Two different plate design for left and right side with indication on side of plate.3. Plate should have 2 mm holes for Proximal Fixation with k-wire. |
| 15 | L- Buttress Plates for Right & Left side wth corresponding screw3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes |
| 16 | L- Buttress Locking Plates for Right & Left side 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes wth corresponding screw |
| 17 | T- Buttress Plates for Right & Left side wth corresponding screw3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes |
| 18 | T- Buttress Locking Plates for Right & Left side 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes wth corresponding screw |
| 19 | Hockey Plate For Tibia (Right & Left) 5, 7, 9, 11, 13, 15, 17 Holes wth corresponding screw |
| 20 | Hockey Locking Plate For Tibia (Right & Left) 5, 7, 9, 11, 13, 15, 17 Holes wth corresponding screw |
| 21 | Contoured Medial/ Antero-lateral Plate for Lower end Tibia 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes wth corresponding screw |
| 22 | Distal Medial Tibial Locking Plates 2.7/ 3.5 mm wth corresponding screw1. Anatomically pre-shaped and low profile and specific for right and left side with Indication of side on plate, compatible with less invasive fixation.2. Rounded edges screw heads should be received into Distal section of plate to allow multiple locking head screw placement of 2.7/ 3.5 mm to provide adequate fixation of metaphyseal portion of tibia, and size 4 to 14 holes with increment of 2 holes. |
| 23 | Anterolateral Distal Tibial Locking Plate 3.5 mm wth corresponding screw1. Anatomically pre shaped and low profile and specific for right and left side with indication of side on plate. Plate should have head holes to accept 3.5 mm Locking head or standard cortical or 4 mm standard cancellous screw.2. Head should be received into the plate.3. Size from 5 to 21 holes with increment of 2 holes |
| 24 | Clover Leaf Plate wth corresponding screw3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes |
| 25 | Clover Leaf Locking Plate wth corresponding screw3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes |
| 26 | Cobra Head Plate wth corresponding screw3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes |
| 27 | Cobra Head Locking Plate wth corresponding screw3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes |
| 28 | Hook Plate wth corresponding screw3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes |
| 29 | Hook Locking Plate wth corresponding screw3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes |
| 30 | Proximal Humerus Locking Plate (PHILOS Plate) wth corresponding screw Anatomically pre-countoured platesShould have precisely fitting sleeves for precision placement of screws. Should accept 3.5 mm Locking Head Screws.The Screws provided should be available from 26 to 60 mm length.The head of the plate should have holes for securing tuberosities to the plate with sutures.Should have low profile of the screws heads to prevent tissue irritation. 3, 4, 5, 6, 7, 8, 9, 10, 12 Holes |
| 31 | Contoured Locking Plate for Distal End Humerus medial and lateral coloumb 3.5 mm wth corresponding screw(Prices to be quoted separately for the following 2 items)1. Anatomically pre-countoured plates for Distal Medial Humerus for anatomical fit with left & right version Should have precisely fitting sleeves for precision placement of screws. Should accept self-tapping Locking Head Screws.The shaft portions of the plate should have Combi holes.Should have low profile of the screws heads to prevent tissue irritation. 3, 5, 7, 9 & 14 Holes2. Dorso-lateral Plates with & without Lateral support with right & left versions Anatomically pre-countoured platesThe shaft portions of the plate should have Combi holesShould have low profile of the screws heads to prevent tissue irritation. 3, 5, 7, 9 & 14 Holes |
| 32 | Calcaneal Plate with corresponding screw SS. |
| 33 | Calcaneal Locking Plateswith corresponding screw SS. |
| 34 | Clavicle Locking Plate- Antero-superior type with corresponding screw SS. |
| 35 | Clavicle Locking Plates- Anterior type with corresponding screw SS. |
| 36 | Clavicle Hook Plate with corresponding screw SS. |
| 37 | Elise Plate/ Contoured Plate for Distal End Radius. 3, 4, 5, 6, 7, 8, 9, 10 Holes with corresponding screw SS. |
| 38 | Locking Elise Plate/ Contoured Locking Plate for Distal End Radius. 3, 4, 5, 6, 7, 8, 9, 10 Holes with corresponding screw SS. |
| 39 | H-Plate with corresponding screw SS.3, 4, 5, 6, 7, 8, 9, 10 Holes |
| 40 | Y- Plate with corresponding screw SS..3, 4, 5, 6, 7, 8, 9, 10 Holes |
| 41 | D.C.P. Small with corresponding screw SS..4, 5, 6, 7, 8, 9, 10, 12, 14 Holes |
| 42 | D.C.P. Narrow with corresponding screw SS.4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes |
| 43 | D.C.P. Broad with corresponding screw SS..4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes |
| 44 | L.C.D.C.P Small with corresponding screw SS..3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes |
| 45 | L.C.D.C.P. Narrow with corresponding screw SS.3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes |
| 46 | L.C.D.C.P. Broad with corresponding screw SS..3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes |
| 47 | L.C.P Small with corresponding screw SS.3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes |
| 48 | L.C.P. Narrow with corresponding screw SS.3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes |
| 49 | L.C.P. Broadwith corresponding screw SS.3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes |
| 50 | Semitubular Plates 4.5mm.with corresponding screw SS.3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes |
| 51 | Semitubular Plates 3.5mm with corresponding screw SS.3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes |
| 52 | 1/3 rd Tubular Plates 4.5mm with corresponding screw SS.3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes |
| 53 | 1/3 rd Tubular Plates 3.5mm with corresponding screw SS.3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes |
| 54 | Quarter-Tubular Plates 2.7 mm. 3, 4, 5, 6, 7, 8 Holes with corresponding screw SS. |
| 55 | Straight Mini Plates 2.0 mm & 1.5 mm. 20 Holes with corresponding screw SS. |
| 56 | Reconstuction Plates 3.5mm with corresponding screw SS.3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes |
| 57 | Reconstuction Locking Plates 3.5mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes with corresponding screw SS. |
| 58 | Reconstuction Plates 4.5mm with corresponding screw SS. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes |
| 59 | Reconstuction Locking Plates 4.5mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes with corresponding screw SS. |
| 60 | 16 mm threaded Cannulated Cancellous Screws 4 mm.25, 30 ….115 mm, in 5 mm increment. |
| 61 | 32 mm threaded Cannulated Cancellous screws 4 mm25, 30…….115 mm, in 5 mm increment. |
| 62 | Fully threaded Solid Cancellous Screws 4 mm25, 30…….115 mm, in 5 mm increment |
| 63 | 16 mm threaded Solid Cancellous Screws 4 mm25, 30,…….115 mm, in 5 mm increment |
| 64 | 32 mm threaded Solid Cancellous screws 4 mm25, 30,…….115 mm, in 5 mm increment |
| 65 | Fully threaded Cannulated Cancellous Screws 6.5 mm25, 30,…….115 mm, in 5 mm increment |
| 66 | 16 mm threaded Cannulated Cancellous Screws 6.5 mm25, 30,…….115 mm, in 5 mm increment |
| 67 | 32 mm threaded Cannulated Cancellous screws 6.5 mm25, 30,…….115 mm, in 5 mm increment |
| 68 | Fully threaded Solid Cancellous Screws 6.5 mm (20 TPI)25, 30,…….115 mm, in 5 mm increment |
| 69 | 16 mm threaded Solid Cancellous Screws 6.5 mm (20 TPI)25, 30,…….115 mm, in 5 mm increment |
| 70 | 32 mm threaded Solid Cancellous screws 6.5 mm (20 TPI)25, 30,…….115 mm, in 5 mm increment |
| 71 | Fully threaded Locking Cannulated Cancellous Screws 6.5 mm25, 30,…….115 mm, in 5 mm increment |
| 72 | 16 mm threaded Locking Cannulated Cancellous Screws 6.5 mm25, 30,…….115 mm, in 5 mm increment |
| 73 | 32 mm threaded Locking Cannulated Cancellous screws 6.5 mm25, 30,…….115 mm, in 5 mm increment |
| 74 | Fully threaded Locking Solid Cancellous Screws 6.5 mm25, 30,…….115 mm, in 5 mm increment |
| 75 | 16 mm threaded Locking Solid Cancellous Screws 6.5 mm25, 30,…….115 mm, in 5 mm increment |
| 76 | 32 mm threaded Locking Solid Cancellous screws 6.5 mm25, 30,…….115 mm, in 5 mm increment |
| 77 | Cannulated Cancellous Screws of 4mm & 6.5mm in 16mm & 32mm Thread from length 30 to 130mm in (5mm, increment) TITANIUM |
| 78 | Washer Round, 13 mm, 10 mm, 7.0 mm, 4.5 mm. |
| 79 | Spiked Washer, 13.5 mm, 8.0 mm, 3.2 mm. |
| 80 | Nut for 4.5 mm Cortex Screw. |
| 81 | Malleolar Screw,4.5 mm 15, 20, 25,………100 mm |
| 82 | Herbert’s screwNote:- The implants listed from Item No. 18 to 97 should be supplied along with all the instruments required for insertion (for which no extra charges/rent will be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between the implant-instrument fitting. |
| 83 | Interlocking Femur Nail (As per AO specifications) with Compatible Locking Bolts Diameter Length8 mm340 to 440 mm9 mm340 to 440 mm10 mm340 to 440 mm11 mm340 to 440 mm12 mm340 to 440 mm |
| 84 | Interlocking Solid Femur Nail (As per AO specifications) with Compatible Locking Bolts Diameter Length8 mm340 to 440 mm9 mm340 to 440 mm10 mm340 to 440 mm11 mm340 to 440 mm12 mm340 to 440 mm |
| 85 | Recon Nail (Right & Left) (As per AO specifications) with Compatible Locking BoltsDiameter Length8 mm340 to 440 mm9 mm340 to 440 mm10 mm340 to 440 mm11 mm340 to 440 mm12 mm340 to 440 mm |
| 86 | Proximal Femur Nail (P. F. N.)LONG right & left (As per AO specifications) with Compatible Locking Bolts Diameter Length8 mm340 to 440 mm9 mm340 to 440 mm10 mm340 to 440 mm11 mm340 to 440 mm12 mm340 to 440 mm |
| 87 | Proximal Femur NailSHORT9mm to 13mm right & left |
| 88 | Trochanteric Entry Femur Nails with Compatible Locking Bolts Diameter Length8 mm340 to 440 mm9 mm340 to 440 mm10 mm340 to 440 mm11 mm340 to 440 mm12 mm340 to 440 mm |
| 89 | Supracondylar Nail (As per AO specifications) with Compatible Locking Bolts Diameter Length10 mm150,200,250,300 mm11 mm150,200,250,300 mm12 mm150,200,250,300 mm |
| 90 | Interlocking Tibia Nail (As per AO specifications) with Compatible Locking Bolts DiameterLength8 mm 280 to 380 mm9 mm 280 to 380 mm10 mm 280 to 380 mm11 mm 280 to 380 mm |
| 91 | Interlocking Distal Tibia Nail (As per AO specifications) with Compatible Locking Bolts DiameterLength8 mm 280 to 380 mm9 mm 280 to 380 mm10 mm 280 to 380 mm11 mm 280 to 380 mm |
| 92 | Interlocking High/Upper Bent Tibia Nail (As per AO specifications) with Compatible Locking BoltsDiameterLength8 mm 280 to 380 mm9 mm 280 to 380 mm10 mm 280 to 380 mm11 mm 280 to 380 mm |
| 93 | Interlocking Solid Tibia Nail (As per AO specifications) with Compatible Locking Bolts Diameter Length8 mm 280 to 380 mm9 mm 280 to 380 mm10 mm 280 to 380 mm11 mm 280 to 380 mm |
| 94 | Expert Tibial Nail (As per AO specifications) with Compatible Locking Bolts Diameter Length8 mm 280 to 380 mm9 mm 280 to 380 mm10 mm 280 to 380 mm11 mm 280 to 380 mm |
| 95 | Interlocking Humerus Nail (As per AO specifications) with Compatible Locking Bolts Diameter Length6 mm200 to 300 mm7 mm200 to 300 mm8 mm200 to 300 mm |
| 96 | Interlocking Bolts (As per AO specifications) Diameter Length2.9 mm12 to 30 mm3.9 mm14 to 48 mm4.9 mm16 to 120 mm |
| 97 | Proximal Bolt RECON (As per AO specifications) DiameterLength6.4 mm60 to 110 mm |
| 98 | Proximal Bolt RECON Cannulated (As per AO specifications)Diameter Length6.4 mm60 to 110 mm |
| 99 | Proximal Bolt P.F.N. Cannulated (As per AO specifications) Diameter Length6.4 mm60 to 110 mm8.0 mm60 to 120 mmNote:- The implants listed from Item No. 98 to 112 should be supplied along with all the instruments required for insertion (for which no extra charges/rent will be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between theimplant-instrument fitting. |
| 100 | Kuntscher’s Nail7, 8, 9, 10, 11, 12 mm diameterNote:- The implant listed in Item No. 113 should be supplied along with all the instruments required for insertion (for which no extra charges/rent will be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between theimplant-instrument fitting. |
| 101 | V-NailNote:- The implant listed in Item No. 114 should be supplied along with all the instruments required for insertion (for which no extra charges/rent will be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between theimplant-instrument fitting. |
| 102 | Square Nail for Ulna2, 2.5, 3, 3.5 mm diameter |
| 103 | Square Nail for Radius2, 2.5, 3, 3.5 mm diameterNote:- The implants listed in Item No. 115 & 116 should be supplied along with all the instruments required for insertion (for which no extra charges/rent will be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between the implant-instrument fitting. |
| 104 | Rush Nail.2.5, 3, 3.5 mm diameter.Note:- The implant listed in Item No. 117 should be supplied along with all the instruments required for insertion (for which no extra charges/rent will be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between theimplant-instrument fitting. |
| 105 | Ender’s Nail.3.5, 4, 4.5 mm diameter. |
| 106 | Titanium Elastic Nailing System (TENS).Note:- The implant listed in Item No. 118 & 119 should be supplied along with all the instruments required for insertion (for which no extra charges/rent will be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between theimplant-instrument fitting. |
| 107 | Non fenestrated bipolar prosthesis37, 39,…………….51, 53 mm |
| 108 | Fenestrated bipolar prosthesis37, 39,…………….51, 53 mm |
| 109 | Thompson Endo-Prosthesis.37, 39, 41, 43, 45, 47, 49, 51, 53 mm.Long stem Austin moore prosthesis37, 39,……………………..51, 53 |
| 110 | Short stem Austin moore prosthesis37, 39,……………………..51, 53 |
| 111 | Austin Moore Endo-Prosthesis.37, 39, 41, 43, 45, 47, 49, 51, 53 mm. |
| 112 | Austin Moore Endo-Prosthesis XL Finish. 37, 39, 41, 43, 45, 47, 49, 51, 53 mm.Note:- The implant listed from Item No. 120 & 127 should be supplied along with all the instruments required for insertion (for which no extra charges/rent will be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between theimplant-instrument fitting. |
| 113 | Bone cement (Price tobe quoted separately for the following 4 items)1.High viscosity Poly Methyl Meth-Acrylate 40gms with working time of 5-6 min.2.Medium to low viscosity Poly Methyl Meth-Acrylate 40gms.3.High viscosity Poly Methyl Meth-Acrylate 40gms with working time of 5-6 min with Gentamycin.4.Medium to low viscosity Poly Methyl Meth-Acrylate 40gms with Gentamycin.Cement Gun should be provide by the dealer as loan instruments without extra charges during Total Hip Replacement surgeries.Cost of Disposable Nozzle to be provided separately . |
| 114 | Cement stopper size …7,8,9……to………….16mmCalcium sulphate bone substitutes |
| 115 | Granules & Wedges 1.G Bone Synthetic HAgranules 10cca. B tri Calcium phosphate granules 1.4 to 2.8mm per porosity 60% Bone Substitutes-5gm, 10gm, 20gm |
| 116 | Cemented TotalHip Replacement THR -*Stem should be as per Standard Design with metal of sufficent strength to withstand life-time use in the patients. Different sizes and offsets to be quoted.*Cup of Polyethylene High Density High Molecular Weight Highly Crosslinked with anti-oxidative manufacturing & storing process (to increases the shelf life) with different offsets.*Cup Sizes : - 38 to 60 mm Outer Diameter and Odd Numbers Sizes*Cemented THR with Polished taper stem with tapering on both planes made of Cobalt Crome Material*Should be having different sizes to cater for small stature, thin built patient& dysplastic hip as well as large hips.*Modularity for neck length and head sizes 22, 28, 32 and 36 mm.*Acetabular component should be metal backed as well as all poly.*Metal back should have modularity to use polyethylene as well as Ceramic.*All Polyethylene liner as well as cups should be made of highly Cross- linked High Molecular Weight polyethylene with measures to prevent Oxidation .*The metal used for stem should be of high tensile strength and fatigue strength like Cobalt-Chrome.Note:-1. Company should be US-FDA /CE/ GMP certified..2. Should provide a technician intraoperatively wherever applicable.3. Should provide suitable size cutting saw with drills (pneumatic/electric) , wherever applicable.4. Should provide all the complementary instrumentation and trials given/provided by the manufacturing company for the application of implant during operation.5. Catalogue/ list of these instrumentation and trials should be included in tender quotations.6. The Cemented and Uncemented Hips should have modularity for interchangibility of cups, heads and stems.7. Only those Joint designs to be sent which have had a proven field record of longevity as substantiated by published literature, the tenderer should provide the required documents |
| 117 | Uncemented T.H.R.*The stem of the Femoral Component should have Double Taper Geometry with Plasma Hydroxy-Appetite coating with at least thickness of the coating of100to200micronsorPorouscoatedwithsufficientporesizeand thickness of porous coating to have optimal bony ingrowth.The Stem should have narraow Distal tip along with highly polished Neck of Angle 135 and 126 Degrees*The stem should accept metal (Cobalt- Chrome) as well as Ceramic Head (Bilox Delta , Zirconium ,Alumina with Zirconia)*There should be modularity regarding size of head & neck length.*Cup of Polyethylene High Density High Molecular Weight Highly Crosslinked with anti-oxidative manufacturing & storing process (to increases the shelf life) with different offsets. Preferably the cup should have longer posterior wall with flange for cement pressurization.*Metal Back cup with Porous Coating and Stikite Coating Resistance for better fit and coating with design to lock into the host bone to provide primary fixation with provision for screw fixation*Should accept liners made up of Highly Cross-Linked High Molecular Weight Poly-Ethylene & Delta Ceramic (Alumina with Zirconia).*The Femoral Head should be made up of Cobalt-Chrome or Delta-Ceramic and ZIrconium and should have different Neck length.*Metal screws for fixation of metal cup.*The whole system should have modularity & inter-changibility.*The Prices should be quoted separately for stems, cups liners of polyethylene and ceramic as per specifications mentioned above and as well as for metal & ceramic heads of different sizes as per specifications quoted above. |
| 118 | uncemented T.H.R. (Ceramic on poly)a. HA Coated femoral stem of different size b. ceramic headfrom 28mm to 36mm with variable neck length c.uncemented acetabulam cup HA coated with option for screw for head 28mm to 36mm with same cup d. acetabular highly cross link poly cup liner different size should accommodate 28mm to 36mm head e. corresponding cup screw Note:-1. Company should be US-FDA /CE/ GMP certified..2. Should provide a technician intraoperatively wherever applicable.3. Should provide suitable size cutting saw with drills (pneumatic/electric) , wherever applicable.4. Should provide all the complementary instrumentation and trials given/provided by the manufacturing company for the application of implant during operation.5. Catalogue/ list of these instrumentation and trials should be included in tender quotations.6. The Cemented and Uncemented Hips should have modularity for interchangibility of cups, heads and stems.7. Only those Joint designs to be sent which have had a proven field record of longevity as substantiated by published literature, the tenderer should provide the required documents |
| 119 | Hybrid T.H.R a.SS Cemented moduler stem (small medium large double tappered highly policed collar less self centering variable offsets )b.moduler enternal head variable size with variable neck length.C. HA cottated Acetabulam cup with screw of different size d.Highely cross link poly cup liner different size e. stem centralizer f. cement restrictor g. Screw for cup Note:-1. Company should be US-FDA /CE/ GMP certified..2. Should provide a technician intraoperatively wherever applicable.3. Should provide suitable size cutting saw with drills (pneumatic/electric) , wherever applicable.4. Should provide all the complementary instrumentation and trials given/provided by the manufacturing company for the application of implant during operation.5. Catalogue/ list of these instrumentation and trials should be included in tender quotations.6. The Cemented and Uncemented Hips should have modularity for interchangibility of cups, heads and stems.7. Only those Joint designs to be sent which have had a proven field record of longevity as substantiated by published literature, the tenderer should provide the required documents |
| 120 | Revision T.H.R.*Revision stem, Modular Straight Cylindrical And Double /Triple Tapered, Porous coated having Slines for cortical fit in the size of 190 ,240 and 300 different lengths.*The diameter and length of the stem should be variable with a provision to address curve of the femur with long stem.*Modularity should be provided for version, offsets, calcar loss and neck length.*Revision cups to be provided with large diameter of upto 65 mm with augments for bone loss in the form of cages and metal rings, as well as, wedges. All these to be quoted separately.Note:-1. Company should be US-FDA /CE/ GMP certified..2. Should provide a technician intraoperatively wherever applicable.3. Should provide suitable size cutting saw with drills (pneumatic/electric) , wherever applicable.4. Should provide all the complementary instrumentation and trials given/provided by the manufacturing company for the application of implant during operation.5. Catalogue/ list of these instrumentation and trials should be included in tender quotations.6. The Cemented and Uncemented Hips should have modularity for interchangibility of cups, heads and stems.7. Only those Joint designs to be sent which have had a proven field record of longevity as substantiated by published literature, the tenderer should provide the required documents |
| 121 | Acetubalar mesh SS |
| 122 | Acetubalar cage of various size |
| 123 | Trabecular Acetubalar augment variuous size & shape |
| 124 | Trarbecular Acetubalar screw various size |
| 125 | Regular Shoulder prosthesis & Reverse Shoulder Prosthesis (Prices to be quoted separately)35 mm, 39 mm |
| 126 | Total elbow prosthesis Regular and custom made |
| 127 | Radial head prosthesis 16 mm x 4 mm x 6 mm18 mm x 4 mm x 6 mm18 mm x 5 mm x 6 mm20 mm x 5 mm x 8 mmNote:- The implants listed in Item No. 134 to 136 should always be supplied along with the suitable instrumentation (for which no extra charges/rent will be levied),which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between the implant- instrument fitting. |
| 128 | Continuous loop endobutton - Titanium madeContinuous loop endobutton One size titanium button with multiple pre-measured loop sizes of 15, 20, 25, 30,35, 40mm lengths.Preloaded with polyester braid suture (#5 leading suture & #2 flipping suture) |
| 129 | Low- Profile Cancellous Screws Titanium madeLow profile head to reduce soft tissue irritation6.5 mm diameter screw 25, 30, 35, 40mm lengths |
| 130 | Spiked and suture WashersWasher 14 and 18 mm |
| 131 | Tibial Post Fixation Screw Titanium madeDia 6.5 mm and 30 mm length |
| 132 | Shaver Blades and Burrs (SS alloy / platinum tip)Single cutting: Razor sharp toothed inner blade No teeth on outer window4mm, 4.5 mm 5mm 5.5mm Straight and angled Double Cutting: The narrow gap between inner and outer cutting surfaces4mm, 4.5 mm 5mm 5.5mmStraight and angledResector: 4mm, 4.5 mm 5mm 5.5mmStraight and angledBurrsBarrel burrs 4mm, 4.5 mm 5mm 5.5mm 6 flute and 12 fluteRound Burrs 4mm, 4.5 mm 5mm 5.5mm6 flute and 12 flute |
| 133 | Spiked Ligament Staple Titanium made Small and large |
| 134 | Cannulated Cross Pin Titanium made 30mm |
| 135 | Cannulated Interference Screws- Roundhead Titanium/Bio absorvable? Standard 4.5mm hex for easier insertion and removal.?in diameters 8mm, 9mm, 10mm and 11mm.?in lengths 20mm, 25mm, 30mm and 35mm. |
| 136 | Cannulated Interference Screws- Fully Threaded Titanium/Bio absorvable?in diameters 8mm, 9mm, 10mm and 11mm. in lengths 20mm, 25mm, 30mm and 35mm |
| 137 | Braided Composite suture (i.e. Bio Fiber/fiber wire)? multi-strand,longchainultra-highmolecularweightpolyethylene (UHMWPE) core with a braided jacket of polyester and UHMWPE? Tapered ,cutting ,reverse cutting and diamond end ,3/8 circle and 1/2 circle?white; white/blue; white/green colours.? USP size 2/ EP size 5.? length 38 inches/90 cms. |
| 138 | Braided polyester suture( i.e.Ethibond )?braided, sterile, surgical suture composed of Poly (ethylene terephthalate).?prepared from fibers of high molecular weight, long-chain, linear polyesters having recurrent aromatic rings as an integral component.? coated with polybutilate or poly {oxy-1, 4 butanediyloxy (1, 6-dioxo-1, 6 hexanediyl)? 2-0 and 5-0 with 4 strands |
| 139 | 5mm synthetic, braided, non-absorbable suture (i.e. Mersilene tape) from fibers of high molecular weight, long-chain, linearpolyesters |
| 140 | Titanium Interference screws for ACL repair. Sizes 8 mm, 9 mm, 10 mm, 11 mm, 12 mm. |
| 141 | Titanium Endo-Button. |
| 142 | Titanium Endo-Disc.Note:- The implants listed from Item No. 137 to 151 should always be supplied along with the suitable instrumentation (for which no extra charges/rent should be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between the implant- instrument fitting. |
| 143 | A. O. Open Clamps. 2.5, 3.5, 4.5 mm. |
| 144 | A. O. Closed Clamps. 2.5, 3.5, 4.5 mm. |
| 145 | Cylindrical/ Universal Clamps. 2.5, 3.5, 4.5 mm. |
| 146 | Rod to Rod Clamp. |
| 147 | Transverse Clamp. |
| 148 | Cortical Schanz Pin 4.5 mm. |
| 149 | Cortical Schanz Pin 4.0 mm. |
| 150 | Cortical Schanz Pin 3.5 mm. |
| 151 | Cortical Schanz Pin 3.0 mm. |
| 152 | Cortical Schanz Pin 2.5mm. |
| 153 | Cancellous Schanz Pin 5 mm. Cancellous Schanz Pin 6 mm. |
| 154 | Tubular Rod. |
| 155 | Connecting Rod.4, 5, 8, 10, 11 mm diameter.4”, 6”, 8”, 10”, 12”, 14”, 16”, 18”.100- 200 mm with 50 mm of increment. |
| 156 | A.O. Type External Fixator R/U. |
| 157 | Finger Distractor. |
| 158 | Radius Ulna Distractor. |
| 159 | Rail Road Fixator for Femur/ Tibia.Note:- The implants listed from Item No. 152 to 169 should always be supplied along with the suitable instrumentation (for which no extra charges/rent should be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between the implant- instrument fitting. |
| 160 | Illizarov’s Ring Fixator. Half Ring.80, 100, 120, 140, 160, 180, 200, 220, 240 mm. |
| 161 | Italian Femoral Arches 900, 1200.80, 100, 120, 140, 160, 180, 200, 220, 240 mm. |
| 162 | Multiple Fixation Clamps. |
| 163 | Schanz Pin Fixation Bolts. |
| 164 | Oblique Supports. |
| 165 | Threaded Rods. 8 mm diameter.75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450 mm. |
| 166 | Telescopic Rods.75, 100, 125, 150, 175, 200, 250, 300, 350, 400 mm. |
| 167 | Male & Female Post. 2, 3, 4, 5 hole set. |
| 168 | Male & Female Hinges. |
| 169 | 1 hole set. |
| 170 | Connection Plates. 5, 6, 7, 8 holes. |
| 171 | Twisted Plates. 5, 6, 7, 8 holes. |
| 172 | Illizarov’s Wires Bayonet Type. 1.5, 1.8, 2.0 mm. |
| 173 | Illizarov’s Wires Olive Type. 1.5, 1.8, 2.0 mm. |
| 174 | Connecting Bolt. |
| 175 | Connecting Nut 10 mm. |
| 176 | Wire Fixation Bolts Cannulated. |
| 177 | Wire Fixation Bolts Slotted.Note:- The implants listed from Item No. 170 to 186 should always be supplied along with the suitable instrumentation (for which no extra charges/rent should be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between the implant- instrument fitting. |
| 178 | JESS External fixator set. |
| 179 | Pelvic C Clamp. |
| 180 | Nails for Pelvic C Clamp. |
| 181 | Steinman Pin.3, 3.5, 4, 4.5, 5 mm. |
| 182 | Denham Pin.3, 3.5, 4, 4.5, 5 mm. |
| 183 | Kirschner Wire double ended Trocar Tip/ Threaded Tip. Diameter 1, 1.5, 2, 2.5, 3 mm.Length 6”, 9”, 12”.Note:- The implants listed in Item No. 192 should always be supplied along |
| 184 | with the suitable instrumentation (for which no extra charges/rent should be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between the implant- instrument fitting. |
| 185 | S.S. Wire Reel. 16 to 28 Gauze.Note:- The implants listed in Item No. 193 should always be supplied alongwith the suitable instrumentation (for which no extra charges/rent should be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between the implant- instrument fitting. |
| 186 | Knowel’s Pin. |
| 187 | A.M. Pin. |
| 188 | Gigli Saw Wire. |
| 189 | Titanium Pedicle Screw & Rod Set (MRI- compatible). |
| 190 | Titanium Cage (MRI- compatible). 10mm, 13mm, 16 mm, 19 mm. |
| 191 | Titanium Staple (MRI- compatible). |
| 192 | Titanium Transverse Connector (MRI- compatible). |
| 193 | Titanium Mono- Axial Screws (MRI- compatible).5.3 mm 30 mm, 35 mm, 4 0 mm, 45 mm.6.0 mm 30 mm, 35 mm, 40 mm, 45 mm. |
| 194 | Titanium Poly- Axial Screws (MRI- compatible).5.3 mm 30 mm, 35 mm, 40 mm, 45 mm.6.0 mm 30 mm, 35 mm, 40 mm, 45 mm. |
| 195 | Hartsheel Implants for Spine (MRI- compatible). |
| 196 | Cervical Plates (MRI- compatible). |
| 197 | Harrington Rod System (MRI- compatible). |
| 198 | Bipolar Prosthesis with modularityBipolar with fixed neck length Component TypeSize(i) Stem 1. Modular Small,medium,large(ii)Head 1. Modular Size 39,41,43……….59 mm |
| 199 | Varying neck lengths with increments of 2.5 mm to 3.5 mm.Component TypeSize(i)Stem Standard(ii) Head39,41,43……….59 mm |
| 200 | Mono axial locking screw 4.5 mm, 5.5 mm, 6.5 mm diameter 30-50 mm with 5 mm of increament |
| 201 | Mono axial locking screw 6.5 mm diameter (Iliac screw) 60 – 75 mm with 5 mm of increament |
| 202 | Cross link (Inter connector) 5 mm |
| 203 | Cervical H-plate ordinary hole 4 hole 20 – 35 mm with 2.5 mm of increament |
| 204 | Cervical H-plate ordinary hole 6 hole 35 – 55 mm with 2.5 mm of increament |
| 205 | Cervical H-plate ordinary hole 8 hole47.5 – 65 mm with 2.5 mm of increament |
| 206 | Cervical spine locking plate 5 hole 25, 29, 33 mm |
| 207 | Cervical spine locking plate 8 hole 37, 41, 45 mm |
| 208 | Drummonds wire without button |
| 209 | Drummonds wire with button |
| 210 | Sublaminar wire 12” Note:- The implants listed from Item No. 197 to 217 should always be supplied along with the suitable instrumentation (for which no extra charges/rent should be levied), which shall be returned back after completion of the operation, & which should be of the same company as the implant, so as to avoid mismatch between the implant- instrument fitting.Titanium plates with bar & Without bar 4 Hole titanium plate (1.5mm, 2mm, 2.5mm) |
| 211 | Disposable Pulse Lavage Tubings. |
| 212 | BASIC Total Knee Replacementa.femoral components co-cr various sizes b.Tibial components cocr variable size c.Tibil insert variable sizesd.patellar button various sizee.Mobile bearing & fixed bearing Kneesf.Cruciate-Retaining/ Cruciate-Scarificing Designs/ Deep Dished Design of Highly Cross Link Materialg.All components should be separately quoted.Note:-1. Company should be US-FDA /CE/ GMP certified..2. Should provide a technician intraoperatively wherever applicable.3. Should provide suitable size cutting saw with drills (pneumatic/electric) , wherever applicable.4. Should provide all the complementary instrumentation and trials given/provided by the manufacturing company for the application of implant during operation.5. Catalogue/ list of these instrumentation and trials should be included in tender quotations.6. The Cemented and Uncemented kneeshould have modularity for interchangibility 7. Only those Joint designs to be sent which have had a proven field record of longevity as substantiated by published literature, the tenderer should provide the required documents |
| 213 | Total Knee Replacement All polyethylene &metal backMobile bearing & fixed bearing KneesHighly polished and Asymetric tibial tray to prevent back wear in Fixed bearing knee and Natural fit to the TibiaAdequate sizes & modularity of Tibial insert to be provided.Pateller component should to be quoted separatelyCruciate-Retaining/ Cruciate-Scarificing Designs/ Deep Dished Design of Highly Cross Link MaterialFor revision,Constraint designs with Intramedullary extension .Designs for achieving high flexion.All components should be separately quoted.Note:-1. Company should be US-FDA /CE/ GMP certified..2. Should provide a technician intraoperatively wherever applicable.3. Should provide suitable size cutting saw with drills (pneumatic/electric) , wherever applicable.4. Should provide all the complementary instrumentation and trials given/provided by the manufacturing company for the application of implant during operation.5. Catalogue/ list of these instrumentation and trials should be included in tender quotations.6. The Cemented and Uncemented Knee should have modularity for interchangibility 7. Only those Joint designs to be sent which have had a proven field record of longevity as substantiated by published literature, the tenderer should provide the required documents |
| 214 | antibiotic spacer mould for infected T.H.R all size & disposable |
| 215 | antibiotic spacer mould for infected T.K.R all size & disposable |
| 216 | Consumable for T.H.R a.HIP U drape plastic imperviousb.Cling drapec.pulse lavage disposable d.Coutery pencil & Suction cannula disposable |
| 217 | Consumable for T.K.R a.knee O drape plastic imperviousb.Cling drapec.pulse lavage disposable d.Coutery pencil & Suction cannula disposabl |
| 218 | Tibial tunnel guide system for ACL Reconstruction (should have locking system with variable angleadjustment from 35 to 60 degree |
| 219 | Cannulated flower tip drill bit with laser making for calculation of bone tunnel length for ACL reconstruction Size 5,6,7,8,9,10,11 mm |
| 220 | Femoral off set guide for 4,5 ,6,7 7 mm |
| 221 | Drill tip graft passing pin 2.4mm |
| 222 | Drilling wird 2.4mm |
| 223 | Graft preparation board |
| 224 | Tedon stripper, 7mm dia close ended |
| 225 | Thickness tester |
| 226 | shaver blades all sizes |
| 227 | suture disc |
| 228 | bio screw driver |
| 229 | ACL repair Implant Bioabsorbale interference screw size 7-11mm, L 20-30mm |
| 230 | Tedon stripper, 7mm dia close ended |
| 231 | Thickness tester |
| 232 | shaver blades all sizes |
| 233 | suture disc |
| 234 | bio screw driver |
| 235 | ACL repair implants Titanium with rounded thread soft cannulated interference screws dia 7-10mm L20,25,30mm |
| 236 | ACL Repair Implant Bioabsorable interence screw size 7-11mm, L20-30mm |
| 237 | ACL repair implant tibial biobsorable interferencescrew with proximal slop to flush fix in anterior tibial cotex size 7-11mm,L20-30mm |
| 238 | shoulder cannula disposable |
| 239 | 3 mm knotted bio absorabable anchor |
| 240 | 2.3 mm knot less bio-absorabable anchor |
| 241 | 2.9mm knot less bio-absorabable anchor |
| 242 | 2.3mm knot less PEEK anchor |
| 243 | 2.9mm knot less PEEK anchor |
| 244 | 3.5 mm knot less bio-absorabable anchor |
| 245 | 3.5mm knot less PEEK anchor |
| 246 | 5.5mm knot les PEEk anchor |
| 247 | ALL PEEk anchor for double & single row cuff repaid Dia4,5,5.5,&6.5mm |
| 248 | Suture passer 45 degree left and right |
| 249 | suture passer 90 degree left and right |
| 250 | Suture shuttle needle |
| 251 | UHMW #2 number white/coloured suture with needles |
| 252 | UHMW #2 number stripped colour with needles |
| 253 | Acromio-clavicular joint dislocation repair system having button on one side & suture disc on other side connerted with suture wire |
| 254 | Radio frequency ablation probe (different angle) for arthroscopy, disposable (please quote rate for one radio frequencyablation probe only and machine generator to be provided by conpany for ablation probe use for surgem) |
| 255 | The Stem should be Collerless Fully Porous Coated with Double /Triple Tapered Design |
| 256 | The Femoral Stem should be available in Standard and Extended Offset options |
| 257 | The Stem Should be available in All Sizes starting from 01 up to 8 ,total 12 sizes |
| 258 | The Tapered Geometry should have option of 12/14 design and compatibility of Heads |
| 259 | The Femoral Heads Sizes should be available in All Sizes from offset -3 ,0,+4,+8 and +12 |
| 260 | The Femoral Heads should have option of All Material Includes Metal Heads/ Cobalt Crome / Oxinium and Bilox Delta Heads |
| 261 | The Acetabular Poly Liner should have Highly Cross link Poly Ethylene liner |
| 262 | The Highly Cross link Poly Ethylene should have 20 Degree Extender Lip on Posterio Superio Wall of Liner |
| 263 | The Acetabular Shell Should have Three holes for Screw Fixation |
| 264 | The Acetabular Shell should have Stikttie Coated Titanium Shell Sizes from 42 to 64 mm |
| 265 | The Acetabular Shell Should have Taper Lock Design and Coampatible to accommodate 6.5 mm Screws self Locking |
| 266 | The Implants Should have Registry Follow up Data and USFDA , CE Certified |
| 267 | The Acetabular Shell should have compatibility to accommodate Ceramic Liner made Bilox Delta Material |
| 268 | The Femoral Component Made of Cobal Crome with Hiflex Design |
| 269 | The Femoral Component Should Have Low Anterior Flange to reduce Notching and Better Fit |
| 270 | Posterior Stabilised Design with Asymetric Tibial Design to Mimic Natural Fit of Tibial Component |
| 271 | The prosthesis should have Option of Cruciate Retaining Design |
| 272 | The Poly Liner Should have Highly Cross Link Poly |
| 273 | The Constraint Liner Should be Compatible with Primary Tibial Base Plate |
| 274 | The Primary Tibial Base Plate should be compatibale with Extended Rods Option size from 100 mm to 150mm |
| 275 | All the TKR Instruments should have Anterior Referencing and Posteiror Referencing |
| 276 | The Insert /Poly Thickness should have 9mm ,11mm,13mm,15mm,18mm and 21mm |
| 277 | The Primary Prosthesis should have Titaniyum Base Plate with Highly Polished surface to reduce Wear backside poly |
| 278 | One Pack of Bone Cement 40gm to be provided along with One TKR Set |
| 279 | The Construct should adhere the Guidelines of NPPA |
| 280 | Drill bits (1mm) |
| 281 | Drill bits (1.5mm) |
| 282 | Drill bits (2mm) |
| 283 | Drill bits (2.5mm) |
| 284 | Stainless Steel Wire (26 Gauge) |
| 285 | Erich arch bar |
| 286 | Titanium plates with bar & Without bar 4 Hole titanium plate (1.5mm, 2mm, 2.5mm) |
| 287 | Titanium plates with bar & Without bar 2 Hole titanium plate (1.5mm, 2mm, 2.5mm) |
| 288 | Titanium plates with bar & Without bar Continous plate titanium plate (1.5mm, 2mm, 2.5mm) |
| 289 | Titanium plates with bar & Without bar L Shaped titanium plate (1.5mm, 2mm, 205mm) |
| 290 | Titanium screw (should be cross hole) 1.5mm (4mm, 6mm, 8mm, 10mm) |
| 291 | Titanium screw (should be cross hole) 2 mm(4mm, 6mm, 8mm, 10mm) |
| 292 | Titanium screw (should be cross hole) 2.5mm (4mm, 6mm, 8mm, 10mm) |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail