Tender For Di-Electric Coating 2000147961 10 10 10 FLOOR PAINTING 500 M2 Email : Amitav.Jena@amns.in Contact : 7381007194 Name : Jena, Amitav - AM/NS India - Elect. & In Item Details : Di-Electric Coating in Electrical Panel room Electrical panel room di electric coating to be applied. MAJOR EQUIPMENT/AREA ELECTRICAL PANEL ROOM: JOB DESCRIPTION /SCOPE OF WORK. : Supply of material as per the TDS and Application of the same as per manufacturer standards/procedures. · All tools & tackles for execution of Job. · PPE’s For workmen. · Transportation for workmen, lodging and boarding. · Before applying new coating, existing floor having di-electric coating to be removed in some panel room. · Test certificate to be provided. MATERIAL PROVIDED BY AMNS: NONE MATERIAL PROVIDED BY CONTRACTOR All materials, tool, tackles <(>&<)> PPE’S ANNEXURE: - Technical specifications For Di-electric Coating- · Di electric, Abrasion, Chemical resistance epoxy system in Electrical panel room-500 SQ. METRE · Electrical Panel room voltage level-11kv. · Preferred Di-electric insulation flooring colour-Blue. · Preferred Make-DEMECH CHEMICAL/PIDILITE · Provide genuine and legal electrical insulation protection meeting breakdown voltage requirements of IS (15652:2006) .Primer,screening and top coating to be done with thickness(only 3000 microns)to be provided for high BDV-83KV · Provide long protective service life. · Anti tracking properties to be ensured. · Prevent surface flame propagation, in case of fire accident occurrence in panel rooms. Page 2 of 4 ArcelorMittal Nippon Steel India Limited AM/NS Pellet Plant Paradeep Village- Udayabatta, Paradeep,Tahasil- Kujang Dist:Jagatsinghpur,754142,Odisha,India GSTIN 21AAACE1741P1ZT PAN AAACE1741P CIN U27100GJ1976FLC013787 Request for Quotation Number 6000107709 Date 06.03.2024 Submission Date 13.03.2024 Coll Req No AMNS deals with OEMs directly. We are very well equipped in every way to import / buy our goods directly from OEMs from any part of the world in a professional manner. We also use the vast global networks of our parent companies where necessary. We do not welcome any contact from intermediaries or Indian Agents of vendors. We assure all OEMs that you do not need to engage anyone to manage your transactions with us.Kindly respond to our RFQs and deal with our officials directly without involving any agents or intermediaries. Offers of vendors who insist on involving intermediaries in dealings with us could be disqualified. Contact for this RFQ null Akhilesh Rathore Contact Email akhilesh.rathore@ext.amns.in MATERIALS / SERVICES Please acknowledge receipt of the RFQ And provide your best quote for below given RFQ details. SR. No PR No. PR Item RFQ Item Services for line Item Quantity UOM Technical Details Other Details · It should be water/weathering resistant. · Good aesthetic look and which can be easily cleaned. · After wear & tear and damage complete system need not to be replaced. In- Situ repairing may be done time to time for very long use. · Monolithic coating to be ensured. · Primer full of adhesion test > 600 psi (concrete failure) · Confirms to standards as in IS:2584-1963/2006. · Finish paints should have followed property: - i)Abrasion resistance (loss/1000 cycles) <(><<)>70 mg ii)Tensile strength >2500 PSI iii)Adhesive pull of strength >700 PSI (Concrete failure) VENDOR SCOPE OF WORK- · Supply of material as per the TDS and Application of the same as per manufacturer standards/procedures. · All tools & tackles for execution of Job. · PPE’s For workmen. · Transportation for workmen, lodging and boarding. · Before applying new coating, existing floor having di-electric coating to be removed in some panel room. · Test certificate to be provided. Item Note : 2 2000147961 20 20 10 FLOOR PAINTING 500 M2 Email : Pravanjan.satapathy@amns.in Contact : 7077769938 Name : Satapathy, Pravanjan - AM/NS India - E&I Item Details : Insulated painting of MRSS floor near 11KV feeder area and 220KV control room of total 500 sq mtrs. approx. Insulated painting of 11KV panel area, 220KV CRP room and battery room. Whole 11KV feeder room, 220KV CRP room and battery room, all are approx. Existing painting of the floor is damaged. Technical specifications For Di-electric Coating- •Di electric, Abrasion, Chemical resistance epoxy system in Electrical panel room-500 SQ. METRE •Electrical Panel room voltage level-11kv. •Preferred Di-electric insulation flooring colour-Blue. •Provide genuine and legal electrical insulation protection meeting breakdown voltage requirements of IS (15652:2006) •Provide long protective service life. •Anti tracking properties to be ensured. •Prevent surface flame propagation, in case of fire accident occurrence in panel rooms. •It should be water/weathering resistant. •Good aesthetic look and which can be easily cleaned. •After wear & tear and damage complete system need not to be replaced. In- Situ repairing may be done time to time for very long use. Page 3 of 4 ArcelorMittal Nippon Steel India Limited AM/NS Pellet Plant Paradeep Village- Udayabatta, Paradeep,Tahasil- Kujang Dist:Jagatsinghpur,754142,Odisha,India GSTIN 21AAACE1741P1ZT PAN AAACE1741P CIN U27100GJ1976FLC013787 Request for Quotation Number 6000107709 Date 06.03.2024 Submission Date 13.03.2024 Coll Req No AMNS deals with OEMs directly. We are very well equipped in every way to import / buy our goods directly from OEMs from any part of the world in a professional manner. We also use the vast global networks of our parent companies where necessary. We do not welcome any contact from intermediaries or Indian Agents of vendors. We assure all OEMs that you do not need to engage anyone to manage your transactions with us.Kindly respond to our RFQs and deal with our officials directly without involving any agents or intermediaries. Offers of vendors who insist on involving intermediaries in dealings with us could be disqualified. Contact for this RFQ null Akhilesh Rathore Contact Email akhilesh.rathore@ext.amns.in MATERIALS / SERVICES Please acknowledge receipt of the RFQ And provide your best quote for below given RFQ details. SR. No PR No. PR Item RFQ Item Services for line Item Quantity UOM Technical Details Other Details •Monolithic coating to be ensured. •Primer full of adhesion test > 600 psi (concrete failure) •Confirms to standards as in IS:2584-1963/2006. •Finish paints should have followed property: - i)Abrasion resistance (loss/1000 cycles) <70 mg ii)Tensile strength >2500 PSI iii)Adhesive pull of strength >700 PSI (Concrete failure) VENDOR SCOPE OF WORK- •Supply of material as per the TDS and Application of the same as per manufacturer standards/procedures. •All tools & tackles for execution of Job. •PPE’s For workmen. •Transportation for workmen, lodging and boarding. •Test certificate to be provided. Item Note : 3 2000150115 10 30 10 FLOOR PAINTING 500 M2 Email : Tanmayee.swain@amns.in Contact : Name : Tanmayee Swain Item Details : Di-Electric Coating in Electrical Panel room Electrical panel room di electric coating to be applied. MCC-9 DI-ELECTRIC COATING IS NOT DONE. JOB DESCRIPTION /SCOPE OF WORK. : Supply of material as per the TDS and Application of the same as per manufacturer standards/procedures. · All tools & tackles for execution of Job. · PPE’s For workmen. · Transportation for workmen, lodging and boarding. · Before applying new coating, existing floor having di-electric coating to be removed in some panel room. · Test certificate to be provided. MATERIAL PROVIDED BY AMNS: NONE MATERIAL PROVIDED BY CONTRACTOR: All materials, tool, tackles & PPE’S ANNEXURE: - Technical specifications For Di-electric Coating- · Di electric, Abrasion, Chemical resistance epoxy system in Electrical panel room-500 SQ. METRE · Electrical Panel room voltage level-11kv. · Preferred Di-electric insulation flooring colour-Blue. · Preferred Make-DEMECH CHEMICAL/PIDILITE. Provide genuine and legal electrical insulation protection meeting breakdown voltage requirements of IS (15652:2006). . Primer, screening and top coating to be done with thickness (only 3000 microns) to be provided for high BDV-83KV. Provide long protective service life. · Anti tracking properties to be ensured. · Prevent surface flame propagation, in case of fire accident occurrence in panel rooms. · It should be water/weathering resistant. · Good aesthetic look and which can be easily cleaned. · After wear & tear and damage complete system need not to be replaced. In- Situ repairing may be done time to time for very long use. · Monolithic coating to be ensured. · Primer Page 4 of 4 ArcelorMittal Nippon Steel India Limited AM/NS Pellet Plant Paradeep Village- Udayabatta, Paradeep,Tahasil- Kujang Dist:Jagatsinghpur,754142,Odisha,India GSTIN 21AAACE1741P1ZT PAN AAACE1741P CIN U27100GJ1976FLC013787 Request for Quotation Number 6000107709 Date 06.03.2024 Submission Date 13.03.2024 Coll Req No AMNS deals with OEMs directly. We are very well equipped in every way to import / buy our goods directly from OEMs from any part of the world in a professional manner. We also use the vast global networks of our parent companies where necessary. We do not welcome any contact from intermediaries or Indian Agents of vendors. We assure all OEMs that you do not need to engage anyone to manage your transactions with us.Kindly respond to our RFQs and deal with our officials directly without involving any agents or intermediaries. Offers of vendors who insist on involving intermediaries in dealings with us could be disqualified. Contact for this RFQ null Akhilesh Rathore Contact Email akhilesh.rathore@ext.amns.in MATERIALS / SERVICES Please acknowledge receipt of the RFQ And provide your best quote for below given RFQ details. SR. No PR No. PR Item RFQ Item Services for line Item Quantity UOM Technical Details Other Details full of adhesion test > 600 psi (concrete failure) · Confirms to standards as in IS:2584-1963/2006. · Finish paints should have followed property: - i)Abrasion resistance (loss/1000 cycles) < 70 mg ii)Tensile strength >2500 PSI iii)Adhesive pull of strength >700 PSI (Concrete failure) Item Note :