Tender For Tender For Supply Of Pacemaker Nad Related Cardiac Items, Udaipur-Rajasthan

Boards / Undertakings / PSU has published Tender For Tender For Supply Of Pacemaker Nad Related Cardiac Items. Submission Date for this Tender is 23-03-2024. Medical Diagnostic x ray Products Tenders in Udaipur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

42686522
Corrigendum : Tender For Tender For Supply Of Pacemaker Nad Related Cardiac Items
Open Tender
Indian
Rajasthan
Udaipur
23-03-2024

Tender Details

Tender For Supply Of Pacemaker Nad Related Cardiac Items , Tender For Pacemaker And Cardiac Related Items , Single Chamber Pacemaker ( Vvir ) With Peel Away Sheath 6 Fr. • Screw In Or Tined Lead •Life Long Battery Warranty • Auto Capture Mode •Minimize Ventricular Pacing Mode • Hysteresis Mode • Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With 6 Fr. Peel Away Sheath • 3.0 T Mri Compatible ( Full Body ) • Usfda / Pmda Approved , Single Chamber Pacemaker ( Vvir ) With Peel Away Sheath 6 Fr. • Screw In Or Tined Lead •Life Long Battery Warranty • Auto Capture Mode •Minimize Ventricular Pacing Mode • Hysteresis Mode • Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With 6 Fr. Peel Away Sheath • 3.0 T Mri Compatible ( Full Body ) • Ceapproved , Dual Chamber Pacemaker ( Ddd ) With Peel Away Sheath 6 Fr. • Screw In Or Tined Lead • Life Long Warranty • Auto Capture Mode • Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With 6 Fr.Peel Away Sheath • 3.0 T Mri Compatible ( Full Body ) • Usfda / Pmda Approved , Dual Chamber Pacemaker ( Ddd ) With Peel Away Sheath 6 Fr. • Screw In Or Tined Lead •Life Long Warranty • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay • Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With 6 Fr.Peel Away Sheath • 3.0 T Mri Compatible ( Full Body ) • Ce- Approved , Dual Chamber Pacemaker ( Dddr ) With Peel Away Sheath 6 Fr. • Screw In Or Tined Lead • Life Long Warranty • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With 6 Fr.Peel Away Sheath • 3.0 T Mri Compatible ( Full Body ) • Usfda / Pmda -Approved , Dual Chamber Pacemaker ( Dddr ) With Peel Away Sheath 6 Fr. • Screw In Or Tined Lead •Life Long Warranty • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay • Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With 6 Fr.Peel Away Sheath • 3.0 T Mri Compatible ( Full Body ) • Ce -Approved , Single Chamber Icd Set • Should Be Supplied With 7.0To7.6 Fr. Defibrillator Lead Shouldbe Compatible With 8 Fr. Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Overspending • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Facility Of Speciallycoated Device For Avoiding Lead Abrasion • Proactive Measurement Of St Segment Changes With Alerts • Usfda / Pmda Approved , Single Chamber Icd Set • Should Be Supplied With 7.0To7.6 Fr. Defibrillator Lead Shouldbe Compatible With 8 Fr. Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Overspending • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Facility Of Speciallycoated Device For Avoiding Lead Abrasion • Proactive Measurement Of St Segment Changes With Alerts • Ce-Approved , Dual Chamber Icd Set • Should Be Supplied With 7.0 To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Lead Profile: Should Be Maximum Up To 5 .8 Fr. And Lead Should Be Compatible With 6 Fr.Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming. • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Proactive Measurement Of St Segment Changes With Alerts • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Usfda / Pmda Approved , Dual Chamber Icd Set • Should Be Supplied With 7.0 To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Lead Profile: Should Be Maximum Up To 5 .8 Fr. And Lead Should Be Compatible With 6 Fr.Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming. • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Proactive Measurement Of St Segment Changes With Alerts • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Ce- Approved , Cardiac Resynchronization Pacemaker With All Accessories - Ra, Rv And Quadripolar Lv Leads And Catheterscrt-P • Lv Lead-Upto 5 Fr. • Rv Lead Up To 5.8 Fr. And Compatible With 6 Fr. Sheath • Atrial Leadup To 5.8 Fr. And Compatible With 6 Fr. Sheath • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • Electrocardiogram Based Av Optimization For Suggesting Optimized Av Delays • Warranty : Minimum 5 Years On Device • Special Algorithms To Predict Lead Failure And Protection Inappropriate Shocks During Failed Lead • Programmable At / Af Alerts With Af Burden Trending • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Special Trigger Mode Biventricular Pacing In Presence Of At / Af • Facility Of Rf Telemetry • Should Be Supplied With 6 Compatible Leads And Introducers For Ra & Rv • Lv Lead Delivery Systems Should Be Compatible With 7 Fr. Ep Catheters Optional • Usfda / Pmda Approved , Cardiac Resynchronization Pacemaker With All Accessories - Ra, Rv And Quadripolar Lv Leads And Catheterscrt-P • Lv Lead-Upto 5 Fr. • Rv Lead Up To 5.8 Fr. And Compatible With 6 Fr. Sheath • Atrial Leadup To 5.8 Fr. And Compatible With 6 Fr. Sheath • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • Electrocardiogram Based Av Optimization For Suggesting Optimized Av Delays • Warranty : Minimum 5 Years On Device • Special Algorithms To Predict Lead Failure And Protection Inappropriate Shocks During Failed Lead • Programmable At / Af Alerts With Af Burden Trending • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Special Trigger Mode Biventricular Pacing In Presence Of At / Af • Facility Of Rf Telemetry • Should Be Supplied With 6 Compatible Leads And Introducers For Ra & Rv • Lv Lead Delivery Systems Should Be Compatible With 7 Fr. Ep Catheters Optional • Ce - Approved , Cardiac Resynchronization Defibrillator With With All Accessories - Ra, Rv And Quadripolar Lv Leads And Catheters Crt-D • Lv Lead-Upto 5 Fr. • Rv Defibrillator Lead : Should Be Supplied Up To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Leadup To 5.8 Fr. And Compatible With 6 Fr. Sheath • 40J Delivered Energy • Pulse Width And Tilt : Programmable As Per Dft • Heart Failure Congestion Monitoring Trends With Alerts • Small Size Below 35Cc • Warranty : Minimum 5 Years • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing ( Optional ) • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Vibratory Patient Alert Optional • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Usfda / Pmda Approved , Cardiac Resynchronization Defibrillator With With All Accessories - Ra, Rv And Quadripolar Lv Leads And Catheters Crt-D • Lv Lead-Upto 5 Fr. • Rv Defibrillator Lead : Should Be Supplied Up To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Leadup To 5.8 Fr. And Compatible With 6 Fr. Sheath • 40J Delivered Energy • Pulse Width And Tilt : Programmable As Per Dft • Heart Failure Congestion Monitoring Trends With Alerts • Small Size Below 35Cc • Warranty : Minimum 5 Years • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing ( Optional ) • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Vibratory Patient Alert Optional • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Ce - Approved , Dual Chamber Pacemaker ( Dddr ) With Peel Away Sheath 6 Fr. –With Conduction System Pacing ( Csp ) • Screw In Or Tined Lead •Standard Warranty Of Minimum 10 Yrs. • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With 6 Fr.Peel Away Sheath • 3.0 T Mri Compatible ( Full Body ) • Usfda / Pmda-Approved , Dual Chamber Pacemaker ( Dddr ) With Peel Away Sheath 6 Fr. –With Conduction System Pacing ( Csp ) • Screw In Or Tined Lead •Standard Warranty Of Minimum 10 Yrs. • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With 6 Fr.Peel Away Sheath • 3.0 T Mri Compatible ( Full Body ) • Ce-Approved , Crt-P With Conduction System Pacing ( Csp ) – With All Accessories Crt-P With All Accessories - Ra, Rv And Quadripolar Lv Leads And Catheterscrt-P • Lv Lead-Upto 5 Fr. • Rv Lead Up To 5.8 Fr. And Compatible With 6 Fr. Sheath • Atrial Leadup To 5.8 Fr. And Compatible With 6 Fr. Sheath • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • Electrocardiogram Based Av Optimization For Suggesting Optimized Av Delays • Warranty : Minimum 5 Years On Device • Special Algorithms To Predict Lead Failure And Protection Inappropriate Shocks During Failed Lead • Programmable At / Af Alerts With Af Burden Trending • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Special Trigger Mode Biventricular Pacing In Presence Of At / Af • Facility Of Rf Telemetry • Should Be Supplied With 6 Compatible Leads And Introducers For Ra & Rv • Lv Lead Delivery Systems Should Be Compatible With 7 Fr. Ep Catheters Optional • Usfda / Pmda Approved , Crt-P With Conduction System Pacing ( Csp ) – With All Accessories Crt-Pwith All Accessories - Ra, Rv And Quadripolar Lv Leads And Catheterscrt-P • Lv Lead-Upto 5 Fr. • Rv Lead Up To 5.8 Fr. And Compatible With 6 Fr. Sheath • Atrial Leadup To 5.8 Fr. And Compatible With 6 Fr. Sheath • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • Electrocardiogram Based Av Optimization For Suggesting Optimized Av Delays • Warranty : Minimum 5 Years On Device • Special Algorithms To Predict Lead Failure And Protection Inappropriate Shocks During Failed Lead • Programmable At / Af Alerts With Af Burden Trending • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Special Trigger Mode Biventricular Pacing In Presence Of At / Af • Facility Of Rf Telemetry • Should Be Supplied With 6 Compatible Leads And Introducers For Ra & Rv • Lv Lead Delivery Systems Should Be Compatible With 7 Fr. Ep Catheters Optional • Ce- Approved , Crt-D With Conduction System Pacing ( Csp ) – With All Accessories Crt-Dwith With All Accessories - Ra, Rv And Quadripolar Lv Leads And Catheters Crt-D • Lv Lead-Upto 5 Fr. • Rv Defibrillator Lead : Should Be Supplied Up To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Leadup To 5.8 Fr. And Compatible With 6 Fr. Sheath • 40J Delivered Energy • Pulse Width And Tilt : Programmable As Per Dft • Heart Failure Congestion Monitoring Trends With Alerts • Small Size Below 35Cc • Warranty : Minimum 5 Years • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing ( Optional ) • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Vibratory Patient Alert Optional • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Usfda / Pmda- Approved , Crt-D With Conduction System Pacing ( Csp ) – With All Accessories Crt-D With With All Accessories - Ra, Rv And Quadripolar Lv Leads And Catheters Crt-D • Lv Lead-Upto 5 Fr. • Rv Defibrillator Lead : Should Be Supplied Up To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Leadup To 5.8 Fr. And Compatible With 6 Fr. Sheath • 40J Delivered Energy • Pulse Width And Tilt : Programmable As Per Dft • Heart Failure Congestion Monitoring Trends With Alerts • Small Size Below 35Cc • Warranty : Minimum 5 Years • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing ( Optional ) • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Vibratory Patient Alert Optional • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Ce- Approved , Pacemaker Lead With Peel Away Sheath Only ( Without Pulse Generator ) For The Existing Company Providing Complete Pacemaker At Rnt Medical College • Usfda / Pmda - Approved , Pacemaker Lead With Peel Away Sheath Only ( Without Pulse Generator ) For The Existing Company Providing Complete Pacemaker At Rnt Medical College • Ce - Approved , Long Sheaths / Introducers- Prefaced Valved Long Sheaths For Rfa With Mullins Curve, Multipurpose Curve, Other Curves, 7F To 9F, Atleast 80- Cm Long, 0.038 Wire Compatible , Long Sheaths / Introducers- Brite Tip Intervention Sheaths With Tip Visualization, Kink Resistant, Cold Shapable With Silicon Coating , Long Sheaths / Introducers- Introducer Sheaths For Electrophysiology, With Various Swartz Curves Sl 0-4, Sr 0-4, 8F, 8.5F , 9F , Long Sheaths / Introducers- Long Sheaths ( Peel Away, Slittable, With Breaking Valve ) For Special Applications Like Coronary Sinus Intubation, Lateral Vein, Special Curves Like Renal, Hook Shape Etc , Long Sheaths / Introducers- Peel Away Introducer Sheaths With Break Away Hwmostatic Valves For Pacing Leads, 5F-12F, 10 Cm – 30 Cm, Optional Infusion Side Port, Radio-Opaque Distal Tip And Multiple Curves , Pacing Lead Stablizers- , Surface Patch For 3 D Mapping – ( Adult & Pediatric ) , Long Sheaths / Introducers- Prefaced Valved Long Sheaths For Rfa With Mullins Curve, Multipurpose Curve, Other Curves, 7F To 9F, Atleast 80- Cm Long, 0.038 Wire Compatible , Long Sheaths / Introducers- Brite Tip Intervention Sheaths With Tip Visualization, Kink Resistant, Cold Shapable With Silicon Coating , Long Sheaths / Introducers- Introducer Sheaths For Electrophysiology, With Various Swartz Curves Sl 0-4, Sr 0-4, 8F, 8.5F , 9F , Balloon Catheter For Non-Contact 3 D Mapping , Diagnostic Ep Catheters- The Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladiumelectrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. All Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Configurations Would Be Pole, French. Curve Of Catheter, Electrode Configuration, Fixed / Deflectable , Woven Ep Diagnostic Catheters – ( Woven Material With Braided Conducting Wire, Ensuring Prolonged Stability ) The Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladiumelectrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. All Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Quadripolar, 5-7, Josephson, 2-5-2-5, Fixed , Cables For Ep & Rfa – The Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladiumelectrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. All Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Quadripolar Cable, Compatible With Quardripolar Catheter , Cables For Ep & Rfa – The Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladiumelectrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. All Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Decapolar Cable, Compatiblewith Decapolar Catheter , Cables For Ep & Rfa – The Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladiumelectrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. All Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Hexapolar Cable, Compatiblewith Hexapolar Catheter , Bi-Directional Steerable Catheters Handle- Thumb Wheel Or Push Pull Automatic Curve Lock Mechanism Electrode – Stainless Steel, Platinum, Palladium Quality Approval – - Description Size ( Fr ) Electrode Spacing ( Mm ) Curve, Small, Large 4.0 , Dual Curve Rf Ablation Catheter Bi-Directional Steerable Electrode – Stainless Steel, Platinum, Palladium Quality Approval – - Description Size ( Fr ) 7.8 Fr Electrode Spacing ( Mm ) 2-5-2 Mm Curve, Medium, , Large, , Extra Large , Ablation Catheters ( Items 1-10 ) - ( All Sizes 4F To 8.5F, All Curves A-K, 270, All Electrode Sizes And Spacing, E.G. ) ( All Itemss Differing In Make / Prices Need To Be Mentioned Seperately. Quote Separately If Different In Terms Of Material, Braiding, Electrode Material Platinum, Palladiumor Stainless Steel Etc ) Quote With Appropriate Connector To Existing Ept 1000 And Stockert Ablators. Ept 1000 Is Not Compatible With Thermocouple And Appropriate Catheters / Connectors Should Be Quoted. Thermistor Catheters Would Therefore By Preferred. In Addition Give Prices Of All Connector Cables / Accessories Seperately. All Items Should Be Compatiblewith Existing Ep Tracer Machine In Rnt Medical College, Udaipur Type Ablation Catheter Regular Tip Size 4 Mm Diameter 6-8Fcurves / Reach All ( Equivalent To A-F, J, K, 270 ) Comments , Balloon Catheter For Non-Contact 3 D Mapping , Ablation Catheters ( Items 1-10 ) - ( All Sizes 4F To 8.5F, All Curves A-K, 270, All Electrode Sizes And Spacing, E.G. ) ( All Itemss Differing In Make / Prices Need To Be Mentioned Seperately. Quote Separately If Different In Terms Of Material, Braiding, Electrode Material Platinum, Palladiumor Stainless Steel Etc ) Quote With Appropriate Connector To Existing Ept 1000 And Stockert Ablators. Ept 1000 Is Not Compatible With Thermocouple And Appropriate Catheters / Connectors Should Be Quoted. Thermistor Catheters Would Therefore By Preferred. In Addition Give Prices Of All Connector Cables / Accessories Seperately. All Items Should Be Compatible With Existing Ep Tracer Machine In Rnt Medical College, Udaipur Type Ablation Catheter Irrigated Tip ( Open ) Tip Sizeanydiameter 7-9Fcurves / Reach All Curves / Reachcomments , Catheters, Cables, Accessories For Endocardial Solutions ( Esi ) Accessories , Reusable Defibrillation / Transcutaneous Pacing Patches ( Suitable For Equipment In . ) , Cryo Catheters ( And Accessories ) For Ablation Of Arrhythmias In Children And Adults – , Leadless Pacemaker With Accessories ( Vvir ) Mode Usfda / Pmda Approved , Leadless Pacemaker With Accessories ( Vvir ) Mode Ceapproved

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-03-2024 Corrigendum Date 19-03-2024
2 18-03-2024 Corrigendum 2 Date 23-03-2024
3 23-03-2024 Corrigendum Technical Bid 23-03-2024

Key Value

Document Fees
INR 1000 /-
EMD
INR 800000.0 /-
Tender Value
INR 4 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail