Supply Installation Testing Commissioning Of Air Conditioner Machines For Department Of Biochemistry Of University Of Calcutta At Ballygunge Science College Campus With All Related Works. , Sitc Of3 Star Rating 2.0Tr Split Air Cinditioner Machine With R, Kolkata-West Bengal

University Of Calcutta has published Supply Installation Testing Commissioning Of Air Conditioner Machines For Department Of Biochemistry Of University Of Calcutta At Ballygunge Science College Campus With All Related Works. , Sitc Of3 Star Rating 2.0Tr Split Air Cinditioner Machine With R. Submission Date for this Tender is 18-03-2024. Air Conditioner Tenders in Kolkata West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

42621376
Supply Installation Testing Commissioning Of Air Conditioner Machines For Department Of Biochemistry Of University Of Calcutta At Ballygunge Science College Campus With All Related Works. , Sitc Of3 Star Rating 2.0Tr Split Air Cinditioner Machine With R
Open Tender
Indian
West Bengal
Kolkata
18-03-2024

Tender Details

Supply Installation Testing Commissioning Of Air Conditioner Machines For Department Of Biochemistry Of University Of Calcutta At Ballygunge Science College Campus With All Related Works. , Sitc Of3 Star Rating 2.0Tr Split Air Cinditioner Machine With R32 Gas Including Remote Controller Of Following Capacity Suitable For Operation On 230V + / - 10% Volt, 50Hz Single Phase Ac Supply With Air Cooled Evaporator With Copper Coil, Fan And Fan Motor.Air Cooled Copper Condenser, Hermetically Sealed Copper Compressor, Propeller Fan Control Panels Incl Wirings, Necy Power Cable Connections From Unit To Power Socket, Refrigerant Pipe Of Appropriate Size Between Indoor And Outdoor Unit Upto 3 Mtr Length. Both Suction & Delivery Incl. Gas Charging, Complete As Required Make ;Necy Ply Wood Board Of 19 Mm To Be Fixed For Installation Of The Machine, Duly Painting As Per Wall Colour.Hitachi, Daikin, Blue Star, Voltas Or Equivalentproviding And Fixing Copper Pipe With Nitrile Rubber Insulation Not Less Than 0.6Mm Thickness Suitable Size Required For Suction And Return Refrigerant With Suitable Insulation For Above Ac S Complete In All Aspects As Required In Excess Of 3Mtrs / Machine Inclsupply And Laying 20Mm Dia Isi Markedflexiblepvc Pipe Along With Accessories On Surface Of The Wall To Drain Out Condensate Water From Indoor Unit5 To10mm Thickness 3 Dia. Upto G / F Drain. Machine To Be Installed By S And F Factoryfabricated Ms Structure For Placing The 2.0 Tr Capacity Split Outdoor Uniton Existing Building. By Ms Fastner&S Andf 4C Flexib;E Copper Cable Of 4Sq.Mm From Indoor To Outdoor Unit Incl.Connection, Commissioing Testing Etc As Reqd

Key Value

Document Fees
Refer document
EMD
INR 22000.0 /-
Tender Value
Refer document