| 1 | Excavating in trenches in Hard and dense soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, laying of cable etc not exc 10 Sq mtr on plan and not exc 1.5 mtr in depth and getting out complete all as specified and directed by the Engr-in-Charge. |
| 2 | Returning , filling in , including spreading, levelling, watering and wellramming in layers not exceeding 25 cm thick in hard/dense soil complete all as specified and directed by the Engr-in-Charge. |
| 3 | Removing excavated surplus soil to a distance upto 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by the Engr-in-Charge |
| 4 | M&L for sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I. |
| 5 | Supplying and laying un-reinforced precast concrete cable cover Class LV, Type I, flat, size 250mm x 150mm x 40mm laid dry over electric cable for protection complete all as specified and directed by the Engr-in-Charge |
| 6 | Taking out defective cable of following size, XLPE/PVC sheathed 1100 volt/11000V grade heavy duty armoured with aluminium conductor from trenches, from wall/poles/under floor etc,shifting serviceable cable for relaying or removing the unserviceable cable complete complete all as specified and directed by the Engr-in-Charge.Note : (i)Excavation and earth work shall be including in quoted rate. (ii)Unit rate of this item is also includes the removal of brick/tile as cable protection, GI pipe and cable joint etc. and nothing extra shall be admissible on this account.(iii)After taking out the cables from the trench, serviceability of cable shall be checked by the contractor in presence of the Engr-in-Charge and nothing extra shall be paid on this account. |
| 7 | 2 core 10 Sqmm |
| 8 | 4 core16 Sqmm |
| 9 | 3.5 core25 Sqmm |
| 10 | 3.5 core35 Sqmm |
| 11 | 3.5 core50 Sqmm |
| 12 | 3.5 core70 Sqmm. |
| 13 | 3.5 core95 Sqmm |
| 14 | 3.5 core 120 Sqmm |
| 15 | Supplying, laying, jointing and testing of under ground cable XLPE insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core10 Sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete complete all as specified and directed by the Engr-in-Charge. |
| 16 | All as per Srl item No. 7.00but size 4 core16 Sqmm. |
| 17 | All as per Srl item No. 7.00but size 3.5 core25 Sqmm. |
| 18 | All as per Srl item No. 7.00 but size 3.5 core35 Sqmm. |
| 19 | All as per Srl item No. 7.00 but size 3.5 core50 Sqmm. |
| 20 | All as per Srl item No. 7.00 but size 3.5 core70 Sqmm. |
| 21 | All as per Srl item No. 7.00 but size 3.5 core95 Sqmm. |
| 22 | All as per Srl item No. 7.00 but size 3.5 core120 Sqmm. |
| 23 | Material and Labour boring of road crossing of size 100mm dia by using manual drilling with use of machinery equipments complete without damaging the surface at suitable depth for drawing cables/pipe lines etc. complete all as directed. Note : (i)Location of boring holes shall be decided by the Engr-in-Charge as per requirement, nothing extra shall be payable on account of variation in length of crossing of road etc.(ii)During boring soil strata may be changed, hence nothing extra shall be paid to the contractor for boring of holes through different strata/different type of soil. Tenderer is hereby advised to keep in mind this aspect while quoting his rates. |
| 24 | Supplyingand laying as in repairs GI tubing medium gradeincl all accessories for pssing ofcables for mechanical proctection, laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall / floor or alongpoles or as street light poles complete accessories such as bends / sockets / reducers / saddles including necessary threading / drilling works complete all as specified and directed by the Engr-in-Charge. |
| 25 | (a) 80 mm bore |
| 26 | (b) 50 mm bore |
| 27 | Supply & fixing in repair Al cable lugs of size 16 Sqmm as specified |
| 28 | Supply & fixing in repair Al cable lugs of size 25 Sqmm specified |
| 29 | Supply & fixing in repair Al cable lugs of size 35 Sqmm as specified |
| 30 | Supply & fixing in repair Al cable lugs of size 50 Sqmm as specified |
| 31 | Supply & fixing in repair Al cable lugs of size 70 Sqmm as specified |
| 32 | Supply & fixinging in repair Al cable lugs of size 95 Sqmm as specified |
| 33 | Supply & fixing in repair Al cable lugs of size 120 Sqmm as specified |
| 34 | Taking out and Re-laying of existing LT UG cable of any size after jointing using LT cable joining kit complete complete all as specified and directed by the Engr-in-Charge. Note : (i) Excavation incl earth work shall be measured and paid for separately.(ii) Joint shall also be measured and paid for separately under respective item of this Schedule(iii)Cable protection i.e. bricks, sand cushioning etc. shall be measured and paid for separately under respective item. |
| 35 | Supply & fixing LT Cable joining kitstraight through heat shrinkabletype complete with joining materials suitable for LT Armoured cablesof size upto 50Sqmm 3.5 core complete all as specified and directed by the Engr-in-Charge. |
| 36 | Supply & fixing LT Cable joining kitstraight through heat shrinkabletype complete with joining materials suitable for LT Armoured cablesof size 70 Sqmm 3.5 core complete all as specified and directed by the Engr-in-Charge. |
| 37 | Supply & fixing LT Cable joining kitstraight through heat shrinkabletype complete with joining materials suitable for LT Armoured cablesof size 95Sqmm 3.5 core complete all as specified and directed by the Engr-in-Charge. |
| 38 | Supply & fixing LT Cable joining kit outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for LT Armoured cablesof size 95 Sqmm 3.5 core complete all as specified and directed by the Engr-in-Charge. |
| 39 | Supply and fixing as in repairs MCCB, 630A, rupturing capacity 50 KA, 415 volts 4 pole adjustable type complete all as specified and directed by the Engr-in-Charge |
| 40 | Supply and fixing as in repairs MCCB, 400A, rupturing capacity 36 KA, 415 volts 4 pole adjustable type complete all as specified and directed by the Engr-in-Charge |
| 41 | Supply and fixing as in repairs MCCB, 250A, rupturing capacity 36 KA, 415 volts 4 pole adjustable type complete all as specified and directed by the Engr-in-Charge |
| 42 | Supply and fixing as in repairs MCCB, 160A, rupturing capacity 36 KA, 415 volts 4 pole adjustable type complete all as specified and directed by the Engr-in-Charge |
| 43 | Supply and fixing as in repairs MCCB, 125A, rupturing capacity 16 KA, 415 volts 4 pole adjustable type complete all as specified and directed by the Engr-in-Charge |
| 44 | Supply and fixing as in repairs MCCB, 63A, rupturing capacity 16 KA, 415 volts 4 pole adjustable type complete all as specified and directed by the Engr-in-Charge. |
| 45 | M&L in replacment of OFF LOAD change over switch with sheet metal enclosure 415V , 4 pole of capacity 320 Amps including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and directed by the Engr-in-Charge. |
| 46 | Supply & fixing in repair of OFF LOAD change over switch with sheet metal enclosure, 415V , 4 pole of capacity 200 Amps including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and directed by the Engr-in-Charge. |
| 47 | Supply & fixing in repair of ON LOAD change over switch with sheet metal enclosure, 415V , 4 pole of capacity100 Amps including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and directed by the Engr-in-Charge. |
| 48 | Supply & fixing in repair of ON LOAD change over switch with sheet metal enclosure, 415V , 4 pole of capacity63 Amps including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and directed by the Engr-in-Charge. |
| 49 | Dismantling insulators any type, any size from its original position and removing from site complete complete all as specified and directed by the Engr-in-Charge. |
| 50 | Supply & fixing pin type composite/polymer incl one galvanised MS spindle, two washers and one galvanised iron nut, 100 mm height,65 mm dia for 1100 volts grade fixed on poles/cross arms of upto 9 m long complete all as specified. |
| 51 | Supply & fixing shackle type composite/polymer insulator incl galvanised mild steel straps, washers, insulator bolts, washers and nuts for working pressure 1100 volt section of strips 31x5 mm bolt dia 14 mm max dia 115 mm, height 100 mm fixed on poles/cross arms of upto 9 m long, complete all as specified. |
| 52 | Dismantling and taking out the old stay assembly complete incl demolition of plain cement all as specified and directed by the Engr-in-Charge.Note : (i) Unit rate of this item includes the loose/disconnect the all accessories which are connected to stay assy includng necessary excavation as directed.(ii)Existing stay assy are fixed on the LT/HT pole of PCC or steel tubular pole, nothing extra shall be paid on this account. |
| 53 | Material and Labour Stay assembly complete with accessories as shown in electrical plate No 1 incl GI Adjustable Stay Rod of 16 mm Dia, GI Stay wire of size 7/4 mm incl stay clamps, loop type insulator, excavation in any strata and PCC 1:3:6 concrete complete all as specified and directed by the Engr-in-Charge. Note:- Unit rate of this item includes the cost of earthwork, loop type insulator, PCC and stay wire. |
| 54 | Re-stretching the existing LT over head line consisting of 5/4/3 conductors of any size using Mechanical tool and one GI wire after removing serviceable/unserviceable separators carefully including opening and reconnecting of jumpers binding conductor over the insulatorproperly with the help of binding wire 14 SWGand re-fixing separators in its original position complete all as specified and directed by Engineer-in-charge. |
| 55 | Supply & fixing PVC line seperator for separating 3/4/5 LT overhead lines all as specified and directed by the Engr-in-Charge. |
| 56 | Dismantling/taking down old unserviceable ACSR conductor of any size from LTpoles over head electric line after disconnecting from insulators complete all as specified and directed by Engineer-in-Charge. |
| 57 | Supply and fixing/ stringing aluminium conductor steel reinforced (ACSR) stretching properly to achieve proper sag on insulators and binding with aluminium tape/binding wire connectors, PG clamps, jumpers etc complete all as specified and directed by the Engr-in-Charge. |
| 58 | Material and labour for preparation of old surface of steel poleincluding channels and applying two coats of aluminium paint including making five no. alternative yellow & black strips 30 cm height each (upto 1.50 metre height from top of PCC coping & numbering to the poles with synthetic enamel paint complete all as specified and directed by the Engr-in-Charge. |
| 59 | M &L FOR easing and adjusting loose door shutter of LT Panels including replacement of old rusted hinges by new one and welding complete complete all as specified and directed by the Engr-in-Charge.Note:- Use of welding machine is included in the unit quoted rate. |
| 60 | Supply & fixing in repair of Digitalvoltmeters 0-500V , with all connected accessories including connecting up and testingcomplete all as specified and directed by the Engr-in-Charge. |
| 61 | Supply & fixing in repair of DigitalAmmetr0-600A (min), with CTs,all connected accessoriesincluding connecting up and testing complete all as specified and directed by the Engr-in-Charge. |
| 62 | Supply & fixing in repair of LED indicator lamp 240 V, with suitable colour Red/Blue/Yellow/Amber/Green and connected acccessories complete all as specified and directed by the Engr-in-Charge. |
| 63 | Supply & fixing aesthetically designed decorative hot dipped galvanised mild steel step pole with grey powder finish of length 3.5 meter with Top diameter of 76mm. Make: Havells Cat part No. DECO POLE 3.5M TOP Ø 76 MMor equivalent in Bajaj Model GORDIAN/ Crompton |
| 64 | Supply & fixing RINK LED POST TOP 45W Made up of Pressure Die Cast aluminium body and opal PC cover. IP 66 and IK 07 rating Suitable for pole dia Ø 76 mm. Make: Havells Cat part no. RINKPT45 WLED757PSYMTOPCor equivalent in Jaquar cat No-OGL-GRY LGTP07X060XW/ Bajaj Model No. 112362 |
| 65 | Supply & fixing in replacementMCB TP 63 A,Curve C 10KA complete all as specified and directed. |
| 66 | Supply & fixing in replacementMCB TPN 63 A,Curve C 10KA complete all as specified and directed. |
| 67 | Note : Deduction for amount of Rs 68762.00 as listed in Schedule A Part - II ( Schedule of Credit) shall be made while awarding of contract. |