| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 23-03-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 30-03-2024 |
| 2 | 12-03-2024 | Corrigendum-02 | BOQ | 23-03-2024 |
| 3 | 08-03-2024 | Corrigendum01 | Date | 23-03-2024 |
| Sl. No. | Item Description |
| 1 | Disconnectingelectric connection of Split/Window air conditioner ,watercooler of any capacityfrom any height and taking down/ keep aside for servicing the samecleaning inside, cleaning of fins by means of airblower and water with pressure jet , cleaning of air filter, remove dust from body, tightening of loose nut bolt, washer, rubber gasket,tightening of loose wiring, loose connection and repair of parts, wornout nutbolt, washers, gasket,valves,temperature sensor,swing motoretc and necessary cutting, welding/soldering works with replacement of rusted bodywith new MS/GI Sheets of suitable size and making the appliancefullyfunctionaland re-assembling and re-installation in same/other position and testing complete all as specified and directed. Note: (i) All repairs works shall be carried out at MES store yard and cost of transportation shall deemed to be included in quoted rates.(ii) All new spare parts to be replaced will be measured and paid separeately under respective items BoQ. |
| 2 | Supply only starting/running capacitor of 5 to 30 mfd capacity for compressor ofWindow/Split Type ACs( 1.5 TR/2.0 TR) complete all as specified and directed. |
| 3 | Supply only starting/running capacitor of 30 to 80mfdcapacity for compressor of Window/Split Type ACs( 1.5 TR/2.0 TR) complete all as specified and directed. |
| 4 | Supply only starting/running capacitor upto 5mfd capacity for Fan motor ofWindow/Split Type ACs( 1.5 TR/2.0 TR) complete all as specified and directed. |
| 5 | Supply only Air Filtersuitable of AC (Window/Split type)1.5 TR/2.0 TR Capacitycomplete all as specified and directed. |
| 6 | Supply only brass suction/discharge valve of size 1/4 \",3/8\",1/2\", 5/8\"for 1.5TR/2.0TRof split AC/window AC complete all as specified and directed. |
| 7 | Supply only Swing motor suitable for 1.5 TR / 2 TRwindow/split type ACscomplete all as specified and directed.Make :- LG/Voltas/Lloyd. |
| 8 | Supply only temperature sensor for 1.5 TR / 2 TR window/split typeAC complete all as specified and directed. Make :- LG/Voltas/Lloyd. |
| 9 | Supply only compressor shut off valve of suitable size for window/split ACup to 2.00 TRcapacitycomplete all as specified and directed. |
| 10 | Supply only brass flare nuts size of1/4 \",3/8\",1/2\", 5/8\"complete all as specified and directed. |
| 11 | Supply only remote hand set of window/split type air conditioner of cap 1.5/2.0 TR of existing make with and including pencil cells AAA type complete all as specified and directed. |
| 12 | Supply only drain pipe of3 mtr length suitable for split type air conditioner of 1.5/2.0 TR of existing make complete all as specified and directed. |
| 13 | Detection and rectification of leakages in refrigerant line bynitrogen gas to find outleakage inwindow / split type AC(1.5/2.0TR)/water cooler of any model/make and ensuring the complete systems leak proof flushing out nitrogen gas including checking the system and charging/Topup of refrigerant gas R-134A / R 22/R-32 or any other refrigerant gas as requiredwith appropriate quantity including testing for smooth functioning and re-assembling and re-installation in same/other position complete all as specified and directed. |
| 14 | S&F Thermostat Switchas per exsisting size/model (Window/Split Type) 1.5 TR/2.0 TR Capacity ACs including taking out unserviceable Thermostat Switch from ACcomplete all as specified and directed. |
| 15 | S&F Thermostatsensor of AC (Window/Split Type) 1.5 /2.0 TR capacity including taking out old unserviceable Thermostat sensor complete all as specified and directed. |
| 16 | S&F in repairof copper tubing 1/4\", 1/2\",3/8\" diacomplete all as specified and directed. |
| 17 | M&L for Starting Relay of AC(Window/Split Type) 1.0/1.5 TR/2.0TR Capacityincluding taking out unserviceable Relay from ACcomplete all as specified and directed. |
| 18 | M&L for Selector Switch of Window AC 1.5 TR/2.0 TR Capacity including taking out unserviceable Selector Switch from ACcomplete all as specified and directed. |
| 19 | M&L for Strainer with Capillary tube/capillary tube of Window/ Split Type AC 1.5 /2.0TR Capacity including taking out unserviceableCapillary Tubefrom ACcomplete all as specified and directed. |
| 20 | S&F in replacement PVC conduit 20mm dia medium grade including all clamps & accessories and connecting the condensate pipe of ACs toconduit for proper drainout of condensate water from ACs upto 3(three) storey building complete all as specified and directed. |
| 21 | S&F ofPVC nylon imbraided pipe15 mm dia forcondensed waterdrain fitted on wallincluding all fittings complete all as specified and directed. |
| 22 | S&F in repair of foam insulation heavy duty for 1.5TR/2.0TR window/split ACs refrigerant line as per exsisting size complete all as specified and directed. |
| 23 | M&L for refrigerant gas charging (Top up)with required quantity of refrigerant R-22/R 32/R 407/R 410 or any other refrigerant as per the requirement in window & split ACs,water cooler of any capacity and make for its smooth functioning after carrying out vaccum and pressure test including necessary soldering/brazing to prevent leakage all as specified and directed. |
| 24 | Taking out defective condensor fan motor from window type AC of capacity 1.5/2.0 TRtransporting defective motor of any make & capacity from site at any height toworkshop dismantling the burnt winding & rewinding theblower motor with the required size of super enamelled copper winding wire of suitable gauge including insulation, varnishing, greasing, testing complete and transporting to back to site and refixing complete all as specified and directed. |
| 25 | All as per item No 24.00 above but for condenser fan motor of split AC (1.5/2.0TR) |
| 26 | All as per item No 24.00 above but for blower fan motor of split AC ( 1.5/2.0TR) |
| 27 | M&L for taking down of window/Split type AC of any capacity or model from any height/ any floor up to threestorey buildingand shifting to another locationin the sameor other building and refixing at New Location including testing of leakage and charging/top up of specified gasas per the make of the AC and make it fully functional again at new locationcomplete all as specified and directed. |
| 28 | S&F cooling coil with fins made of copper suitable for Window type AC (1.5/2.0 TR) as per existing model/size including removing of old cooling coil complete all as specified and directed. |
| 29 | All as per item No 28.00 above but forsplit AC ( 1.5/2.0TR) |
| 30 | S&F condensing coil with fins made of copper suitable for Windowtype AC (1.5/2.0 TR) as per existing model/size including removing of old condensing coilcomplete all as specified and directed. |
| 31 | All as per item No 30.00 above but forsplit AC ( 1.5/2.0TR) |
| 32 | S&F new condensor fan of 1.5/2.0 TR split ACmotor as per exsisting make/model with copper winding of suitable guage including taking out old unserviceable condensor fan moter complete all asspecified and as directed.Make:Voltas/Blue star/LG/Samsung |
| 33 | All as per item No 32.00 above but for 1.5/2.0 TR window AC |
| 34 | S&F new condenser fanblade as per exsisting make/model 1.5/2.0 TR window/split AC with copper winding of suitable a guage including taking out old unserviceable condensor fan blade complete all asspecified and as directed.Make:Voltas/Blue star/LG/Samsung |
| 35 | Dismantling of defective condensing unit ( outdoor unit) of spilt type AC of 1.5 TR capacityand supply and fixing new condensing unitcomplete with compressor,condensing coil, coil frame, wiring kit and running capacitor, relay,condensing motorwith blade complete all as specified and directed. |
| 36 | S&F in repair ofPCB for Split ACs of any type of capacity 1.5/2.0 TR complete all as specified and directed. |
| 37 | S&F in repairofPCB forwindow type ACs of any type of capacity 1.5/2.0 TRcomplete all as specified and directed. |
| 38 | M&L for removing brunt wiring kitof window /spilt type ACs, water cooler with best qualitynew wiring kit suitable type of PVC insulated copper conductor cable including thimbles sleaves of suitable size & shape complete all as specified and directed. |
| 39 | S&F PVC blower for SplitType AC 1.5/2.0 TR Capacity of approved Make and required Size to suit existing AC including removal of unserviceable blower complete all asspecified and as directed. |
| 40 | All as per item No 39.00 above but forwindow AC ( 1.5/2.0TR) |
| 41 | Dismantling of defective PCB of window/Split AC of1.5/2.0 TR capacity of any make & type andrefixingafter repairing the PCB to ensure proper functioning of the AC complete all as specified and directed. |
| 42 | M&L for writing of SM/MES No etc on window AC,Split AC,Water cooler,Desert coolerwith synthetic enamel paint of any colour on site using stencil complete all as specified and directed. |
| 43 | M&L for dismantling of unserviceable/worn out hermetically sealed unit compressorfrom windowACand supply and fixing compressor, suitable for existing model/make of capacity 1.5/2 TRwindow type AC including brazing with suction and discharge line, checking the system for leak proof and includingcharging of refrigerant gas R-134 A /R 22 /R-32 in appropriate qty after makingvaccum the complete systemand testing the AC for proper functioning complete all as specified and directed. |
| 44 | All as per item No 43.00 above but forsplit AC ( 1.5/2.0TR) |
| 45 | Dismantling of defective indoor unit of 1.5 TR capacity split typeAC and supply & fixing new indoor unit of the same capacity & make which includes all parts in it and connecting the copper tubing by brazingand recharging withrefrigerant gas as required quantitymaking air conditioner functional complete all as specified and directed. |
| 46 | S&F12 mm thick prelaminated, panticle board, BWR, grade 1, one side decorative teak veneers and other side commercial veneered finished fixing in small pices around window AC to make air tighton wall/window including necessary cutting, drilling or fixing with screws etc complete all as specified and directed. |
| 47 | S&F of2nd class Hardwood (Sal) fillets, cross sectional area 45mm X 45mm splayed or chamfered edge including polishing etc to fixon all four sides of window type AC to make secure on wall/window including necessary cutting, drilling or fixing with screws etc complete all as specified and directed. |
| 48 | S&F in repair of stand mounting bracket (heavy duty)for split AC (1.5/2.0TR) made of 2mm thick high steel power coating for rust prevention suitable for wall/floor mountedout door AC unit,including fixing with suitablefastenerson exsisting location/building (upto three storey) complete allas specified and as directed. |
| 49 | S&F in replacement water collection tray made out of CGI sheet 2 mm thick suitable for window AC upto 2 Ton capacity and connect it to nearest PVC pipe/ drain etc complete all as specified and directed. |
| 50 | S&F inrepair reverse cycle solenoid valve in splittype AC 1.5 / 2 TR capacitywithnecessaryextension to suction/ discharge copper tubing & toggle switch complete all as specified and directed. |
| 51 | S&F in repair front grill quality for window AC of 1.5 TR/ 2 TRof Make LG/Carrier / Blue Star/Samsung/videocon complete all as specified and directed. |
| 52 | S&F Sheet metalenclosure with socket plug top and MCBs single pole with a two pin and earth plug andsocket complete with one single pole MCB of\"C\" series of capacity 16-32 Amp including taking out the old unserviceable complete all as specified and directed. |
| 53 | M&L metal clad Industrial plug top ISI mark 2 pin with earth 250 Voltsincluding taking down old unserviceable complete all as specified and directed. |
| 54 | S&F in replacement MCB SP 16-32Amps rating of \"C\" seriesto be housed in industrial socket complete all as specified and directed. |
| 55 | M&L Metal clad Industrial socketISI mark with earth 250 Voltsincluding taking down old unserviceable complete all as specified and directed. |
| 56 | S&F sub main wiring using approved colour coding (Phase-red, Neutral-black, Earth-green) complete with two single core FRLS PVC insulated and unshealthedstranded copper conductor cable 4 Sqmmas current carrying conductor and one run of 4.0 Sqmm as earth contunity conductor, voltage rating 1100 volt, ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with standard accessories including taking down old unserviceable submain wiring complete all as specified and directed. Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and PVC conduit shall be measured as one unit. |
| 57 | M&L for removing the desert cooler from its existing position at any height from stand or pillar, removing the side panels, taking out unserviceable wood wool pads or loose pads including supporting jali (HDPE plastic /steel wire mesh)and disposed to a distance not exceeding 50 metres away as directed and spray painting with synthetic enamel paint of approved tint (inside and outside) including one coat of black japan paint in side the base of tank after preparation of old painted surfaces and reassembling and fixing in positionincluding oiling and greasing of fan kit, water pump motor, refixing wood wool pad secured with new HDPE soft mesh complete all as specified and directed. |
| 58 | Taking down of unserviceabledetachable type perforated side panel from exsisiting desert coller S&F new perforated side panel made out 22 gauge PGI sheetsuitable for desert cooler over all size of 0.75mx0.75mx0.91m mtrcomplete all as specified and directed. |
| 59 | S&F in replacement of unserviceable wood wool pads with supreme quality white wood wool (set of three) in repair includingPVCpipe pieces 03 Nos of required length & dia for connection of water distributor/ elbows of desert coolers of complete all as specified and directed. |
| 60 | Supply and fixing in replacement of supreme quality white wood woolin loose suitable for industrial desert coolercomplete all as specified and directed. |
| 61 | S&F in repair of switch piano flush button single pole one way 15 Amp, 240 Volts in desert cooler conforming to IS 3854 ISI markedcomplete all as specified and directed. |
| 62 | S&F in repair of Polycarbonate Plug top 3 pin 6/16 Amp of desert cooler complete all as specified and directed. |
| 63 | Supply and fixing in repair ofcopper conductor three core PVC insulated and sheathed cable size 1.50 sqmmISI mark for desert cooler etc complete all as specified and directed. |
| 64 | Supply and fixing in renewal of desert cooler submersible pump having power of 18/20W,and output 1200 Ltr/hr single phase 230 Volt AC, (ISI marked) suitable for evaporating type desert cooler including fixing clamp inside the desert cooler complete all as specified and directed |
| 65 | Supply and fixing in renewal of desert coolersubmersible pumphaving power of 40W &3500 Ltr/Hr output, single phase 230 Volt AC, (ISI marked)suitable for Industrial type cooler including fixing clamp inside the Industrial type cooler complete all as specified and directed |
| 66 | S&F in repair ofsteel multi wing exhaust fan blade set of best quality as per existing type and size of16\"/18\" sweep heavy duty for desert cooler complete all as specified and directed. |
| 67 | Taking down unserviceable fresh air fan motor (Fan kit) from desert cooler and supply and fixing new fresh air fan kit of copper winding (150-300Watt),1500 RPM,230 Volts single phase as per exiting sample/ size and fixing in same position by providing new nut, bolts, washer, MS frame/side arms and rubber pads etc including testing complete all as specified and directed. |
| 68 | Taking downunserviceableexhaust fan (heavy duty) of 16\"/18\"sweep size,2800 rpm from desert cooler, supply and fixing newexhaust fan (copper winding) of same capcity complete with fan blade ,fixing in the same position by providing new nut, bolts, washer, MS frame/side arms and rubber pads etc including testing complete all as specified and directed. |
| 69 | Taking out defectiveexhaust fan of 16\"/18\"of any make from desert/industrial coolerand transporting it tocontactor\"s workshop, opening of fan motor , taking out rotor, cutting out the burnt winding ,cleaning the slots and rewinding of the same with the existing size of super enameled copper winding wire including insulation varnishing, greasing, painting reassembling testing and fixing in position complete all as specified and directed. |
| 70 | Taking out defective desert cooler fan ofcapacity upto 300watt, 1500rpm capacity from desert coolerrewinding of the same with the existing size of super enameled copper winding including varnishing, greasing, painting reassembling testing and fixing in positioncomplete all as specified and directed. |
| 71 | Taking down unserviceable exhaust fan frame and S&F fan frame and supporting Leg for exhaust fan including nut, bolts, washer Rubber,clamp etc complete Set complete all as specified and directed. |
| 72 | S&F in repairof capacitor upto 4.5Mfd for desert cooler fancomplete all as specified and directed. |
| 73 | S&F ply wood 6mm thick, cut to shape as required on site and fixing on wall/ window/ cooler opening with and including necessary nuts & bolts/ screws complete all as specified and directed. |
| 74 | M&L for removing of perished body of desert cooler over all size 0.750x0.750x0.910 mtr from existing site andreplace the same with new body made out of 22 gauge PGI sheet by means of fabrication welding/ jointing having tank size approximete 0.750x0.750x0.230mtr and front grillmade out of 26 gauge PGI sheet 0.460x 0.460mtr size for air flow direction,03 Nos perforated sheet side panels size Approximate 0.680x0.610mtr of each and also having electric control panel consisting two nos 5amp switch, one rotary speed regulator switch complete and duly painted with two coats of synthetic enamel paint over one coat of primer internally and externally including fixing the exiting fan kit & Pump motor received from old unserviceable Desert Cooler including all electrical connections, testing and commisioning complete all as specified and directed. |
| 75 | Taking out the unserviceable sealed compressor unit from water cooler andS&F New Sealed compressor unit of existing sample, suitablefor 40/80 Ltr &60/120 Ltr capacity of water cooler replace with newcompressor (duly tested) and checking the complete system for leak proof and including charging of refrigerant gas R-134 ain appropriate quantity and testing for smooth functioning complete all as specified and directed. |
| 76 | Supply and fixing in replacementof evaporator coil ISI marked suitable for water cooler of any make/type/ capacity including all fixing accessories and making connection / detecting leakage and gas charging etc complete all as specified and directed. |
| 77 | S&F in repairof starting/running capacitor upto 30Mfd for blower motor of water coolerhaving capacityof 40/80 & 60/120 ltrcomplete all as specified and directed. |
| 78 | S&F starting/ over load Relay for Water Cooler having capacity 40/80 and 60/120 Litres ofany make including removing unserviceable relay complete all as specified and directed. |
| 79 | S&F thermostat switch /relay suitalbe for water cooler having capacity 40/80 and 60/120 Litres of any make including removing unserviceable onecomplete all as specified and directed. |
| 80 | S&F condenser coil(copper tubing) for Water Cooler having capacity 40/80 and 60/120 Litres ofany make including removing unserviceable condenser coil complete all as specified and directed. |
| 81 | Taking out the burnout blower motor from water cooler andS&F New single phaseblower motor (copper winding) of existing sample/size suitablefor 40/80 Ltr & 60/120 Ltr capacity of water cooler complete all as specified |
| 82 | S&F in replacement defective push cock 15 mm bore brass chromium plated heavy duty suitable for water cooler of any make and capacity complete all as specified and directed. |
| 83 | S&F in replacement stainless steel waste water tray suitable for water cooler upto 150 ltrs capacitycomplete all as specifed and directed. |
| 84 | Taking out defectivewater cooler blower motor any make/size fromcooler upto 60/120 ltr capacity , cutting out the burnt winding cleaning the slots and rewinding of the same with the existing size of super enameled copper winding wire includinggreasing, reassemblingcomplete all as specified and directed. |
| 85 | S&F 05 KVA wall mounted type stabilizer for automatic operation single phase naturally air cooled indoor type designed for input variation between 170Vto 285V and with output voltage stabilizer at 230V with accuracy of +/-2.5% completeand taking out old unserviceable stabilizer complete all as specified and directed. |
| 86 | S&F in repair of PCB with high & low voltage cut off suitable for 4 KVA/5 KVA voltage stablizers of any make complete all as specified and directed. |
| 87 | S&F in repair of power transfromers suitable for voltage stablizers of capacity 4/5 KVAcomplete all as specified and directed |
| 88 | M&L for repairing to base/stand of water cooler of any make/type/capacity upto 60/120 Ltr including welding of MS/GI sheet 16 SWG of suitable size to fill up rusted patches, grinding and applying base material for smooth surface and applying two coat of synthetic enameled spray paint of existing colour over one coat of primer etc complete all as specified and directed. |
| 89 | Taking down ceilling fan/exhaust/air circulating fan of any size or make by disconnecting electric connection and removing from site for rewinding,servicing, painting of fans and refixing the same position or all as directed. |
| 90 | Cleaning, washing, greasing, oiling and varnishing of ceiling fan of any size and make complete all as specified and directed. |
| 91 | M&L for opening and rewinding with super enamelled copper winding wire of existing size of ceiling fan 1200/1400 mm sweep complete all asspecified and directed. Note : Cost of transportaion from site to workshop in deemed to be includedin quoted rates. |
| 92 | All as per ser item No 91.00 here-in-before but for exhaust fans/wall mounted fan of any size (200mm/250mm/450 mm) sweep. |
| 93 | M&L for replacement of defective ball bearing for ceilling fan of 1200 mm sweep size (Bearing make/size SKF-6201/6202/ or equivalent) complete all as specified and directed. |
| 94 | M&L for replacement of defective capacitor of size 2.5/3.5 mfd for any type of fans suitable for 250 V including making connection complete all as specified and directed. |
| 95 | M&L for replacement of flexible copper conductor cable 3 core PVC insulated & PVC sheathed 1100 Volts grade size of cable 23/0.0076 complete all as specified and directed. |
| 96 | M&L for painting of ceilling fans any make of size upto 1400 mm at site with one coat of superior quality synthetic enamelled spray paint of approved make by spraying, filling cavities with filler after preparation of surface and wirting letter as per existing such as (MES AC12345) with black systhetic enameled paint 1\" high on both sides of fans all as specified and directed. |
| 97 | S&Fin replacement Metal ExhaustfanAC single phase 230 voltof size 380 mm sweep,with minimum 1300 RPMwith louvers and shutter connecting up including provision of cable from ceiling rose. |
| 98 | S&Fin replacement Metal Exhaust fan AC single phase 230 voltof size 450 mm sweepwith minimum 2400 RPM heavy dutywith lovoure and shutter connecting up including provision of cable from ceiling rose etc complete all as specified and directed. |
| 99 | S&Fin replacement wall mountedfans 230 volts with minimum 1300 RPMsingle phase oscillating 250 mm sweep suitable for wall mounting complete all as specified and directed. |
| 100 | S&Fin replacement PVC ventillation fan, working on single phase, 230 Volts, 50 Hz of sweep 200 mm with louverswith minimum 1300 RPM complete including fixing arrangement, grouting of Bolts in wall etc all as specified and as directed.Note :- For the item 97.00 to 100.00 : Old unservicealbe fans shall be deposited in MES store yard. |
| 101 | Takingdownexisting unserviceable/old point wiring surface /batten includingfitting fixtures ,ceiling roses, pendant/angle holders, regulators, sockets,switches andPVC conduitcomplete all as specified and directed. |
| 102 | Material and labour for point wring ,using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with FRLS PVC insulated and unshealthedstranded copper conductor cable 1.5 sqmm single coreconforming to IS 694 including medium duty concealed unplasticised PVC conduit conforming to IS 9537(part-3) and ISI marked not less than 20 mm dia with concealed in wall pressed steel terminal box of not less than 2 mm thick of required size including painting terminal boxs inside and outside with two coat of synthetic enamle paint over one coat of red oxide primerwith top cover3 mm thickbakelight laminated sheetwith brass screws and Cup washer with all assessories including FRLS PVC insulated and unshealthedstranded copper conductor cable 1.5 sqmm single core in green colouras earth wireconnected to earth dolly complete all as specified and directed . |
| 103 | One light/fan/exhaust fan point/call bell point controlled by 1 No,one way 5/6 Amp switch. |
| 104 | One 3 pin /5 pin socket outlet 5 Amp controlled by 1 No one way 5/6 Amp switch on same board along with other switches ,fan regulator etc. |
| 105 | One 3 pin /5 pin socket outlet 5 Amp controlled by 1 No one way 5/6 Amp switch on independent board. |
| 106 | One light point controlled by two 2-way switches |
| 107 | Material and labour for point wring ,using approved colour coding (Phase-red,Neutral-black,Earth-green) complete for one socket outlet 15 Amp on independent board with FRLS PVC insulated and unshealthedstranded copper conductor cable 2.5 sqmm single coreconforming to IS 694 including medium duty concealed unplasticised PVC conduit conforming to IS 9537(part-3) and ISI marked not less than 20 mm dia with concealed in wall pressed steel terminal box of not less than 2 mm thick of required size including painting terminal boxs inside and outside with two coat of synthetic enamle paint over one coat of red oxide primerwith top cover3 mm thickbakelight laminated sheetwith brass screws and Cup washer with all assessories including FRLS PVC insulated and unshealthedstranded copper conductor cable 2.5 sqmm single core in green colouras earth wireconnected to earth dolly complete all as specified and directed . |
| 108 | S&F switch piano flush button single pole two way 6 Amp, 240 Volts conforming to IS 3854 ISI marked complete all as specified and directed . |
| 109 | S&F switch piano flush button single pole one way 6 Amp, 240 Volts conforming to IS 3854 ISI marked complete all as specified and directed. |
| 110 | S&Ffor socket outlet, 5 Pin, 6 Amp flush type conforming to IS 1293 ISI markedcomplete all as specified and directed. |
| 111 | S&F switch piano flush button single pole one way 15 Amp, 240 Volts conforming to IS 3854 ISI marked complete all as specified and directed. |
| 112 | S&Ffor socket outlet, 3 Pin, 15 Amp flush type conforming to IS 1293 ISI marked complete all as specified and directed. |
| 113 | S&Fceiling rose, surface Bakelite,isolated bodythree terminals complete all as specified and directed. |
| 114 | S&F Electronic fan regulator steped type(flush type) 240 volt ,50Hz,single phase on existing phenotic laminated sheetand connecting complete all as specified and directed. |
| 115 | S&F sheet metal enclosures (MCB Distribution board) when MCB’s to be used singlepole and neutral 8 ways 220 volt with 200 amps rated bus bar, double door with bus bar neutral link earth bar, Din rail, necessary blanking plated, including fixing DB flush in wall complete with making good disturbed surfaces as per existing specified and directedincluding taking down old one. |
| 116 | S&F MCBs single pole, 10 KA ,6 Amp to 30 Amp 240 Volts,and of \"\"B\"\" series with required wiring connections and lugs etcincluding taking down old one complete all as directed. |
| 117 | S&F MCBs single pole and neutal,32 Amp to 40 Amp 240 Volts,and of \"\"B\"\" series with required wiring connections and lugs etcincluding taking down old one complete all as directed. |
| 118 | Material and Labour for earthing complete with Steel earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded by 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same.GI plate connected with galvanised iron earth wire 4.00 mm dia by means of Copper nuts, bolts and washers.GI wire shall be laid in 20 mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following provisions complete all as specified and shown in electrical plate No 3 of SSR Part-I & including testing on completion and taking out old materials of earthing :-(a)GI wire of 4 mm dia.(b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits)(c)Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1, exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar 75mm centre to centre both ways with 2 Nos MS handles of 12mm diamild steel TMT bars suitable for carrying of pit cover.(d) All PCC work shall be in 1:2:4 type B-1 using 20mm graded stone aggregate. |
| 119 | S&F decorative, wall mounting, champagne gold finish fixture with plastic body suitable and including9 W LED lamp B22 base complete including taking down the old holder complete all as directed by engg in charge. Make: Havells Cat pat No LHFOECE1TZ1O014 or equivalent in PHILIPS/Orient Electric/Crompton |
| 120 | S&F in repair LED bulb 9 W complete all as specified and directed. |
| 121 | S&F in repair Lamp holder, PVC/Polycarbonate type with back plate suitable for batten complete all as specified and directed. |
| 122 | S&F in replacement 20W LED tube with double side connection, 6000K complete all as specified and directed. |
| 123 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC box type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for mounting on flat roofincluding connecting up with driver three core flexible copper conductor cases of suitable size complete including taking down oldconventional light fitting complete all as specified and directed. |
| 124 | Supply and fixing LEDround shape 12 watt ,6 inch dia,1320 lmcomplete with driver, holders & LED lamp suitable for mounting on flat roofincluding connecting up with driver three core flexible copper conductor cases of suitable size complete including taking down oldconventional light fitting complete all as specified and directed. |
| 125 | S&F in repair switch piano flush button single pole one way 6 Amp, 240 Volts conforming to IS 3854 ISI marked complete all as specified and directed. |
| 126 | S&F in repair for socket outlet, 5 Pin, 6 Amp flush type conforming to IS 1293 ISI marked including complete all as specified and directed. |
| 127 | S&F in repairswitch piano flush button single pole one way 15 Amp, 240 Volts conforming to IS 3854 ISI marked complete all as specified and directed. |
| 128 | S&F in repair for socket outlet, 3 Pin, 15 Amp flush type conforming to IS 1293 ISI marked complete all as specified and directed. |
| 129 | S&F in repair electronic fan regulator steped type(flush type) 240 volt ,50Hz,single phase on existing phenotic laminated sheetincluding taking down old one and connecting complete all as specified and directed. |
| 130 | S&F in repair Lamp holder, PVC/Polycarbonate type with back plate suitable for batten complete all as specified and directed. |
| 131 | S&F in repair modular switch single pole one module 6 Amp complete all as specified and directed. |
| 132 | S&F in repair modular socket single pole two module 6 Amp complete all as specified and directed. |
| 133 | S&F in repair modular switch single pole one module 15/16 Amp complete all as specified and directed. |
| 134 | S&F in repair modular socket single pole two module 15/16 Amp complete all as specified and directed. |
| 135 | S&F in repair modular white cover plate with frame 4 module complete all as specified and directed. |
| 136 | S&F in repair modular white cover plate with frame 6 module complete all as specified and directed. |
| 137 | S&F in repair modular white cover plate with frame 8 module complete all as specified and directed. |
| 138 | S&F in repair switch socket combination 2 in 1 , 5 & 15 amps complete all as specified and directed. |
| 139 | S&F Decorative ultra slim round profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient,18/20 watt,50 Hz including taking down the old unserviceable ligh fitting complete all as specified and directed. |
| 140 | S&F bulkhead light 10 watt suitable for outdoor application including taking down the old unserviceable light fitting complete all as specified and directed. Make: Havells Cat pat:RUGBYGENXFTS10WLED865SSYMBOPC or equivalant in Crompton/Phillips/Orient Electric. |
| 141 | S&F in repair PVC insulated FR-LSH, multistranded, 1100 Volts, single core flexible copper conductor of size 1.5 sqmm including fixing as per existingpointcomplete all as specified and directed. |
| 142 | S&F in repair PVC insulated FR-LSH, multistranded, 1100 Volts, single core flexible copper conductor of size 2.5 sqmm including fixing as per existingpointcomplete all as specified and directed. |
| 143 | S&F in repair PVC casing caping of size 20 x 12 mmfixing on wall as per existing including all fixing arrengementcomplete all as specified and directed. |