Providing Electrical Work As Per Requirements For Municipal Council Dharashiv- Temporary Electrification, Cctv Etc. 2 Providing Temporary Illumination Consisting Of Led Flood Light Fitting 100W, Having Colour Temp Up To 6500K, Ip65, Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Erected With Mains, Switchgears With Continuous Earth Wire Erected And Dismantled With Using Scaffolding Up To Three Days 3 Providing Temporary Illumination Consisting Of Flood Light Fitting 200 W Complete Led Fitting Having Colour Temp Up To 6500K, Ip65, Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Required Switchgear Erected And Dismantled With Using Scaffolding Up To Three Days. 4 Providing Temporary Illumination Consisting Of Flood Light Fitting 300 W Complete Led Fitting Having Colour Temp Up To 6500K, Ip65, Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Required Switchgear Erected And Dismantled With Using Scaffolding Up To Three Days. 5 Providing Temporary Illumination Consisting Of White / Colour Series Lights With 8Mm Led Miniature Lamps Of 2 To 3.4V [ 1000Nos ] With Cap With Required Switchgears Erected And Dismantled With Rotor Effect As Approved Without Scaffolding Up To Three Days. 6 Providing Temporary Illumination Consisting Of White / Colour Series Lights With 8Mm Led Miniature Lamps Of 2 To 3.4V [ 1000Nos ] With Cap With Required Switchgears Erected And Dismantled With Rotor Effect As Approved With Scaffolding Up To Three Days. 7 Providing Temporary Illumination Consisting Of Water Proof Led Par Light, 54 Pieces X 3W, 230V, 50Hz, With Rgbw Controller Complete Erected With Mains, Switchgears With Continuous Earth Wire Erected And Dismantled Without Using Scaffolding Up To Three Days 8 Providing Temporary Illumination Consisting Of Water Proof Led Par Light, 54 Pieces X 3W, 230V, 50Hz, With Rgbw Controller Complete Erected With Mains, Switchgears With Continuous Earth Wire Erected And Dismantled With Using Scaffolding Up To Three Days 9 Providing Temporary Illumination Consisting Of Water Proof Hmi Par Light, 4000 W, 230V, 50Hz, Colour Temp 6500K Housing Of Pressure Die Cast Aluminium Alloy [ Multi Colour ] Complete Erected With Mains, Switchgears With Continuous Earth Wire Erected And Dismantled Without Using Scaffolding Up To Three Days 10 Providing Temporary Illumination Consisting Of Water Proof Hmi Par Light, 4000 W, 230V, 50Hz, Colour Temp 6500K Housing Of Pressure Die Cast Aluminium Alloy [ Multi Colour ] Complete Erected With Mains, Switchgears With Continuous Earth Wire Erected And Dismantled With Using Scaffolding Up To Three Days 11 Providing Temporary Xlpe / Pvc Armoured Cable 4 Core 50 Sq Mm Aluminium Conductor With Continuous 12 Swg G.I. Earth Wire Complete Erected With Gland And Lugs And Switchgears And Required Cable Protector Wherever Necessary Up To Three Days 12 Providing Temporary Xlpe / Pvc Armoured Cable 4 Core 95 Sq Mm Aluminium Conductor With Continuous 10 Swg G.I. Earth Wire Complete Erected With Gland And Lugs And Switchgears And Required Cable Protector Wherever Necessary Up To Three Days 13 Providing Temporary Digital Projector Having Full Hd 1080P Resolution With White And Colour Brightness At Range Of 3000-4000Lm, Hdmi Port, Usb Port, Av Port, Computer Port With Spring Loaded White Screen Connected With Necessary Mains, Required Switchgears And Maintaining The Same During The Function Including Dismantling. 14 Providing, Maintaining And Operating Temporary Public Address System On Hire Consisting 02 Nos. Solid State Heavy Wattage Amplifier 250 Watts ( One For Working And Another For Stand By Emergency ) Working On Ac / Generator And 24 Volt Car Battery Supply, 06 Nos. Of Matching Of 100 Volt Line ( 200 Watts ) Box Type Speakers / Sound Column, 02 Nos Super Sensitive Microphone With Suitable Size Of Microphone Holding Stand. The System Shall Be In 15 Providing, Maintaining And Operating Temporary Dual Pa Uhf Wireless Microphone On Hire Consisting 01 Nos. Receiver Having S / N Ratio 100Db, Frequency Response 50-15000Hz, Controls Like On / Off Switch, Volume Control And 02 Nos. Of Handheld Wireless Transmitter With New Aa Batteries Having On / Off Switch, Channel Frequency Display, Carrier Frequency Range 630-664Mhz For One Day. 16 Providing And Maintaining Temporary Cordless ( Hand Type Or Lapel Type ) Super Sensitive Uhf Microphone ( 1 No Stand By ) For One Day. 17 Providing, Commissioning And Maintaining Temporary Cctv System With 8 Channel Nvr, Ip Video / Audio Input - 1 No, Ip Based 4.0 Mp, Full Hd, Ir Ip Dome Camera - 2 Nos, Ip Based 4.0 Mp, Full Hd, Ir Ip Ptz Camera - 2 Nos, 4Tb Hard Disk - 2 No, 42 Full H D Professional Display - 1 No, 8 Port Poe Switch - 1 No, Power Supply Unit To Camera - 1 No, On Line Ups - 1 No With Necessary Mains, Switchgears On Hire Basis For One Day 18 Providing, Commissioning And Maintaining Additional Ip Based 4.0 Mp, Full Hd, Ip67, Ir Ip Ptz Camera In Existing Cctv System With Necessary Mains, Switchgears On Hire Basis For One Day. 19 Hiring Charges For Supplying And Maintaining 230 / 415 V, 50 Cycles Ac Generating Set 3 To 10 Kva Capacity With Necessary Fuel, Mains, Switchgears And Accessories Complete With Continuous Running On Load / No Load As Per Requirements Complete With Self Certification. 20 ???? ( 10 X 10 ) ( ????? ????? ) 21 ?????????? 5 ??? ??? ???? ????? 22 ?????????? 5 ??? ??? ???? / ????? ????? 23 ???? ( 10 X 10 ) ( ??. ??. ???? ????? ) 24 ???????? ???? ( ??. ????????? ??????? ????? ??????? ????? / ?. ?????? ?????? ????? ??????? ) 25 Office, Admin Building, Schools Electrification, Street Light Repair, Flood Light For Water Pump House, Generator Repair, Ac Repairetc. 26 Supplying And Erecting Pvc Trunking ( Pvc Casing-N-Capping ) Of Size 32 Mm With Accessories On Wall / Ceiling As Per Specification No: Wg-Ma / Con. 27 Supplying And Erecting Mains With 2X1.5 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places As Per Specification No: Wg-Ma / Bw 28 Supplying And Erecting Mains With 2X2.5 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places. As Per Specification No: Wg-Ma / Bw 29 Supplying And Erecting Mains With 2X4 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places. As Per Specification No: Wg-Ma / Bw 30 Supplying And Erecting Mains With Wp 2 X 4 Sq. Mm. 1100 V Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete Erected With Required Size Of Porcelain Reel Insulators And 16 Swg G.I. Binding Wire. 31 Supplying And Erecting Mains With Wp 2 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete Erected With Required Size Of Porcelain Reel Insulators And 16 Swg G.I. Binding Wire 32 Supplying And Erecting Mains With Wp 4 X 4 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete Erected With Required Size Of Porcelain Reel Insulators And 16 Swg G.I. Binding Wire 33 Supplying And Erecting Mains With Wp 4 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete Erected With Required Size Of Porcelain Reel Insulators And 16 Swg G.I. Binding Wire 34 Supplying And Erecting Mains With Wp 3 X 4 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete Erected With Required Size Of Porcelain Reel Insulators And 16 Swg G.I. Binding Wire 35 Supplying And Erecting Mains With Wp 3 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete Erected With Required Size Of Porcelain Reel Insulators And 16 Swg G.I. Binding Wire 36 Supplying And Erecting Modular Type Switch 6A / 10A Duly Erected On Provided Plate And Box With Wiring Connections Complete. 37 Supplying And Erecting Modular Type Switch 16A Duly Erected On Provided Plate And Box With Wiring Connections Complete 38 Supplying And Erecting Modular Type 3 Pin 6A Multi Socket With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections 39 Supplying And Erecting Modular Type 3 Pin 6 / 16A Multi Socket With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete. 40 Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 1 Module Complete Duly Erected 41 Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 2 Module Duly Erected. 42 Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 6 Module Duly Erected 43 Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 12 Module Duly Erected. 44 Supplying And Erecting 6 To 32 A, 10Ka, Spmcb Suitable To Fix In 1 Module Of Modular Switch In Provided Box Complete & Duly Concealed With Necessary Material And Connected 45 Supplying And Erecting 16 To 32 A, 10Ka, Dpmcb Suitable To Fix In 2 Module Of Modular Switch In Provided Box Complete & Duly Concealed With Necessary Material And Connected. 46 Supplying And Erecting Pvc Surface Modular Double Mounting Plate 1 Module Complete Duly Erected. 47 Supplying And Erecting Pvc Surface Modular Double Mounting Plate 2 Module Complete Duly Erected. 48 Supplying And Erecting Pvc Surface Modular Double Mounting Plate 6 Module Complete Duly Erected. 49 Supplying And Erecting Pvc Surface Modular Double Mounting Plate 12 Module Complete Duly Erected. 50 Point Wiring For Light / Bell / Exhaust Fan In Pvc Trunking ( Casing-Capping ) With 1.5 Sq.Mm ( 2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories As Per Specification No: Wg-Pw / Sw 51 Point Wiring For Ceiling Fan In Pvc Trunking ( Casing-Capping ) With 1.5 Sq.Mm ( 2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories As Per Specification No: Wg-Pw / Sw 52 Point Wiring For Independent Plug In Pvc Trunking ( Casing-Capping ) With 1.5 Sq.Mm ( 2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories As Per Specification No: Wg-Pw / Sw 53 Supplying And Erecting Led Square / Circular Max. 18 W Down Lighter / Panel Light Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 2000 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd<10%, P.F. >0.95, Operating Range Of 120-270V, Surge Protection Of2.5 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete 54 Supplying And Erecting Led Panel Light ( 600Mm X 600Mm ) Max. 30 W Having Crca Powder Coated Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 3600 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd<10%, P.F. >0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50, 000 Hrs. At L70b50 Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete 55 Supplying And Erecting Led Strip Light 5M Length Max. 95 W Ip20 Class Having Minimum Lumens Output Of 1600 Lumens / M, Min. Efficacy Of 90 Lumen / W, Cri>80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd<10%, P.F. >0.95, Operating Range Of 230-270V, Life Class Of 30, 000 Hrs. At L70b50 Including Driver With 1 Year Warranty. 56 Making Suitable Size Recess In Any Type Of False Ceiling For Erection Of Flush Type Down Lighter And Finishing The Background To Match The Original Surface Upto 20W. 57 Making Suitable Size Of Recess In Any Type Of False Ceiling For Erection Of Flush Type Led Panel Light 600Mm X 600Mm / 1200X300mm And Finishing The Background To Match The Original Ceiling Surface. 58 Supplying & Erecting Inverter Led Batten 20W Tube Light Fitting With Polycarbonate Housing, Heat Sink, Integrated Hf Electronic Driver, Min. 2600 Mah Lithium Ion Battery With Charging Time Of 8-10 Hours And Backup Time Of Min. 3 Hrs. With Minimum 25% Of Initial Watts Having Luminous Efficacy Of 100 Lumen / Watt, Cri>80, Cct Of 6500K And Thd<=20% Having Useful Life Of Minimum 25000 Hrs. With Overheating Protection 59 Supplying & Erecting Uv Fly Killer / Bug Catcher Light Fitting Having 2 X 20W Uv Tube Lights To Cover Min. Area Of 500 Sq.Ft With Powdered Coated M.S. / Steel Body Suitable To Work On 230V, Ac Supply Having Top Mounting Arrangement With Ss Chain Complete And 3 Core 1 Mtr. Flexible Wire With 1 Year Warranty. 60 Supplying And Erecting Electronic Type Cordless Call Bell Erected On T.W. Board Having Portable Bell Push Working On 9V D.C. Battery And ( Effective Range Upto 45 Meter ) Bell On 250 V A.C. Supply. 61 Supplying & Erecting 5W-7W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base. 62 Supplying And Erecting Regular / Standard Model Ceiling Fan Of 600Mm. Sweep Complete Erected In Position As Per Specification No. Fg-Fn / Cf 63 Supplying And Erecting Regular / Standard Model Ceiling Fan Of 900 / 1050 Mm. Sweep Complete Erected In Position As Per Specification No. Fg-Fn / Cf 64 Supplying And Erecting Regular / Standard Model Ceiling Fan Of 1400Mm. Sweep Complete Erected In Position As Per Specification No. Fg-Fn / Cf 65 Supplying And Erecting Cabin Fan Of A.C. 230 V. 50 Cycles 400 Mm. Sweep Complete With Necessary Brackets For Fixing Cabin Fans, Wire Etc. 66 Supplying And Erecting Fresh Air Cum Exhaust Fan Of Light Duty 250 V A.C. 50 Cycles 300Mm. 1400 Rpm Rust Proof Body & Blades, Wire Mesh, Duly Erected, Complete. 67 Supplying & Fixing Anchor Type Fastener Fan Hook, With 2 Nos. Of 10 Mm Dia X 75 Mm Long With Necessary Materials For Ceiling Fan. 68 Supplying And Erecting Fan Hook Box Of 10 Mm M.S. Round Bar Bounded To The R.C.C. Bars Upto 50 Mm Length Each Side And Pierced Through A 16 S.W.G. Thick Aluminium / M.S. Bowl 100 Mm Dia. Or Equivalent Square Size And Having Depth Upto 75 Mm Complete Erected With Duly Painted By One Coat Of Red Oxide Paintand Two Coats Of Paint Erected In Position And Without Any Leakage Of Slurry Of Cement Concrete On Either Side Of The Box And Positioned To The Bottom Level Of The Slab. 69 Supplying And Erecting Electronic Type Step Regulator For Ceiling Fan 600 / 900 / 1200 / 1400 Mm. Sweep, Complete Erected On Provided Switch Board. 70 Supplying And Erecting Integrated Led Flood Light Fitting Max. 70W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 8400 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.90, Operating Range Of 140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 71 Supplying And Erecting Street Light Bracket Made From 25 Mm. Dia ‘B’ Class G.I. Pipe, 0.6M. In Length Along With Pole Cap Of 300 Mm Length And 80 Mm Dia Duly Welded With Provided Leads As Per Specification No. Fg-Bkt / Bpc 72 Supplying And Erecting Street Light Wall Bracket Made From 25 Mm. Dia ‘ G.I. Pipe 1.2 M. In Total Length Complete As Per Specification No. Fg-Bkt / Wb 73 Electrician 74 Supplying & Erecting Seamless Outside & Inside, Smooth, Dry And Clean Copper Pipe With Rohs Compliant Suitable For Refrigerant Having 22Swg Thickness And Inner Dia / Size 16Mm Complete. 75 Supplying, Installing, Testing And Commissioning Of Single Phase, 230V, 50 Hz, 1400 To 1600Va Digital Pure Sine Wave Inverter With Backup Time Of ........ Hrs. Based On Insulated Gate Bipolar Transistor ( Igbt ) Technology Complete As Per Specification No. Ap-Inv 76 Supplying, Installing, Testing And Commissioning Of Single Phase, 230V, 50 Hz, 2500 Va Digital Pure Sine Wave Inverter With Backup Time Of ........ Hrs. Based On Insulated Gate Bipolar Transistor ( Igbt ) Technology Complete As Per Specification No. Ap-Inv 77 Supplying And Erecting 12V / 180Ah Tubular Battery With Battery Terminal Wire, Duly Charged With 36 Months Warranty Complete 78 Supplying And Erecting 12V / 200Ah Tubular Battery With Battery Terminal Wire, Duly Charged With 36 Months Warranty Complete 79 Providing Annual Comprehensive Maintenance Contract For 1.5Trsplit / Window Air Conditioning Unit Complete As Per Terms And Conditions. Job Includes 1 ) Quarterly Servicing 2 ) On Call Repair 3 ) Replacement Of All Spares Within 24 Hours 4 ) Sending Standby Manpower For Vip Movement. The Job Exclude Sheet Metal Work And Plastic Material. 80 Providing Annual Comprehensive Maintenance Contract For 2Trsplit / Window Air Conditioning Unit Complete As Per Terms And Conditions. Job Includes 1 ) Quarterly Servicing 2 ) On Call Repair 3 ) Replacement Of All Spares Within 24 Hours 4 ) Sending Standby Manpower For Vip Movement. The Job Exclude Sheet Metal Work And Plastic Material. 81 Providing Replacement Of Existing Unserviceable Rotary / Scroll Compressor Of Air Conditioner 1.5Tr By New One Of Same Capacity With Guarantee For One Year With Provided Refrigerant Complete 82 Providing Replacement Of Existing Unserviceable Rotary / Scroll Compressor Of Air Conditioner 2Tr By New One Of Same Capacity With Guarantee For One Year With Provided Refrigerant Complete. 83 Providing Replacement Of Existing Unserviceable Rotary / Scroll Compressor Of Air Conditioner 2.5Tr To 4.5Tr By New One Of Same Capacity With Guarantee For One Year With Provided Refrigerant Complete. 84 Providing Flushing Out Cooling Coil And Condenser Coil Of Airconditioner Unit Refrigerant Pipes Internally With Dry Nitrogen Pressure, Complete 85 Providing Replacement Of Unserviceable Starting Relay For Ac Unit 86 Providing Replacement Of Unserviceable Starting Capacitor For Ac Unit 87 Providing Replacement Of Unserviceable Running Capacitor For Ac Unit. 88 Providing Replacement Of Unserviceable Pcb For Ac Unit Upto 3Tr Capacity 89 Providing Vaccumising The Airconditioner System To 200 Micron And Charging With Refrigerant R32 For Ac Unit. 90 Providing Replacement Of Existing Unserviceable Condenser Coil Of 40 / 80 / 150 Litre Cooling Capacity Water Cooler By New One Of Same Capacity, Testing To The Satisfaction Of Site Engineer For Cooling And Along With Guarantee For One Year With Suitable Refrigerant 91 Providing Replacement Of Existing Unserviceable Compressor Of 150 Litre Cooling Capacity Water Cooler By New One Of Same Capacity Along With Suitable Refrigerant With Guarantee For One Year. 92 Supplying And Erecting Candle Filter With Filter Pot For Water Cooler 93 Providing Replacement Of Base Tray Of Water Cooler Of Any Capacity 94 Supplying And Erecting On Load Four Pole Automatic Transfer Switch, 415V, 200A, 50 Hz With Enclosure, Flexibility Of Neutral Connection, Line And Load Reversibility, Changeover With Phase Barriers, Source Separator, Terminal Covers Along With Staggered Termination For Cable Connection And Ats Controller With Provision Of Time Delay Protection Of Ov, Uv, Phase Sequence Changing, Single Phasing And Event Logging, Connected With Provided Leads Complete Complying To Is / Iec 60947-3 Part-1 / 6 95 Supplying, Erecting & Marking Spmcb 6A To 32A, B-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb 96 Supplying, Erecting & Marking Spmcb 40A To 63A, B-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb 97 Providing & Erecting 3 Pole Mccb, 415V, 200A, Rated Short-Circuit Breaking Capacity 25 Ka ( Ics=100% Of Icu ) , Adjustable Thermal ( Overload ) Setting And Adjustable Magnetic Setting With Provided Leads, Provision For Installation Of Shunt / Uv / Trip Alarm Contact And Mccb Should Have Phase Barriers Both Sides, With Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure / Panel As Per Specification No. Sw-Swr / Mccb 98 Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 100A Erected On Polished Wooden Block 99 Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 200A Erected On Polished Wooden Block. 100 Supplying And Erecting Metal Work In Crca Sheet Including Iron Work For Supports With Fabrication Of Boxes, Panel Boards, Etc. Including Cutting, Bending, Drilling, Welding, Riveting, Treated With Anti-Rust Treatment And Duly Powder Coated Or Painted With One Coat Of Red Lead Paint And 2 Coats Of Enamel Paint Complete. 101 Supplying And Erecting Gi Sheet 0.6 Mm ( 24 Swg ) Having Zinc Coating Of 275 Microns With Galvanization Process Compliance To Is 2629:1985 To Be Used For Fabrication Of Boxes Panel Boards Etc. Including Cutting, Bending, Drilling, Welding, Riveting Etc. And Painting With One Coat Of Red Lead Paint And 2 Coats Of Enamel Paint. 102 Supplying And Erecting Plywood 6 Mm Thick Fixed To Wall Or On Provided Panel Board With Necessary Materials Such As Screws, Wall Fasteners Supports, Nuts Bolts Etc. Complete. 103 Supplying And Erecting 50 Kvar, 440 V 3 Phase, 50 Hz., Contactor Logic & Intelligent Relay Micro Apfc Passive Filter Panel, Consisting Of Suitable Steps Of App / Mpp Type Capacitor Units With Detuned ( Harmonic Filter ) Reactors Of Suitable Rating , Apfc Panel Shall Be Compliance To Iec 61439 And Power Quality Iec 61921 Standard As Per Specification No Cp-Ed / Apfc 104 Supplying And Erecting 100 Kvar, 440 V 3 Phase, 50 Hz., Contactor Logic & Intelligent Relay Micro Apfc Passive Filter Panel, Consisting Of Suitable Steps Of App / Mpp Type Capacitor Units With Detuned ( Harmonic Filter ) Reactors Of Suitable Rating , Apfc Panel Shall Be Compliance To Iec 61439 And Power Quality Iec 61921 Standard As Per Specification No Cp-Ed / Apfc 105 Supplying And Erecting 250 Kvar, 440 V 3 Phase, 50 Hz., Contactor Logic & Intelligent Relay Micro Apfc Passive Filter Panel, Consisting Of Suitable Steps Of App / Mpp Type Capacitor Units With Detuned ( Harmonic Filter ) Reactors Of Suitable Rating , Apfc Panel Shall Be Compliance To Iec 61439 And Power Quality Iec 61921 Standard As Per Specification No Cp-Ed / Apfc 106 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 3½Core 400 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 107 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 3 Core 50 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 108 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core 10 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 109 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core 16 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 110 Supplying , Erecting & Terminating Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 11 Kv ( E ) , 3 X 95 Sq. Mm. Aluminium Conductor Laid In Provided Trench / Pipe As Per Specification No. Cb-Ht 111 Providing & Erecting Epoxy Straight Through Joint Outdoor / Indoor For Lt Xlpe Armoured Cable 70 To 95 Sq Mm., With Necessary Material As Per Specification No. Cb-Jt / Lt 112 Providing & Erecting Epoxy Straight Through Joint Outdoor / Indoor For Lt Xlpe Armoured Cable 300 Sq Mm., With Necessary Material As Per Specification No. Cb-Jt / Lt 113 Providing & Erecting Epoxy Straight Through Joint Outdoor / Indoor For Lt Xlpe Armoured Cable 400 Sq Mm., With Necessary Material As Per Specification No. Cb-Jt / Lt 114 Providing And Erecting Heat Shrinkable Indoor Termination Kit For 11 Kv ( E ) Xlpe Ht Cable 3X Up To 95 Sq. Mm. With Necessary Material As Per Specification No. Cb-Jt / Ht 115 Providing And Erecting Heat Shrinkable Indoor Termination Kit For 11 Kv ( E ) Xlpe Ht Cable 3X240 To 300 Sq. Mm. With Necessary Material As Per Specification No. Cb-Jt / Ht 116 Providing And Erecting Heat Shrinkable Indoor Termination Kit For 11 Kv ( E ) Xlpe Ht Cable 3X400 Sq. Mm. With Necessary Material As Per Specification No. Cb-Jt / Ht 117 Providing And Erecting Heat Shrinkable Out Door Termination Kit For 11 Kv ( E ) Xlpe Ht Cable 3 X Up To 95 Sq. Mm. With Necessary Material As Per Specification No. Cb-Jt / Ht 118 Providing And Erecting Heat Shrinkable Outdoor Termination Kit For 11 Kv ( E ) Xlpe Ht Cable 3X400 Sq. Mm. With Necessary Material As Per Specification No. Cb-Jt / Ht 119 Supplying & Erecting Single Compression Type Brass Cable Glands For 3½ Core 95 Sq Mm For Xlpe Armoured Cable As Per Specification No. Cb-Gl 120 Supplying & Erecting Single Compression Type Brass Cable Glands For 3½Core 300 Sq Mm For Xlpe Armoured Cable As Per Specification No. Cb-Gl 121 Supplying & Erecting Single Compression Type Brass Cable Glands For 3½Core 400 Sq Mm For Xlpe Armoured Cable As Per Specification No. Cb-Gl 122 Supplying & Erecting Crimping Type Copper Lugs For Cable 95 Sq Mm Complete As Per Specification No. Cb-Cl / Cu 123 Supplying And Erecting Rolled Steel Joist ( Girder ) Pole 150 X 80 Mm / 150 X75 Mm ( 14.9 Kg / M ) With Base Plate In Provided Foundation As Per Specification No. Oh-Pl / Rsj 124 Supplying & Erecting Ms Pole Bracket For Guarding / Lt Oh Line, Fabricated From Angle Iron 50X50x6mm And 1100Mm Long For Necessary Nos. Of Provided Insulators, And Erecting On Pole With 50X6mm Clamp Complete As Per Specification No. Oh-Pl / Bkt 125 Supplying & Erecting Ms Pole Bracket For Guarding / Lt Oh Line, Fabricated From Ism Channel 75X40x6mm And 550Mm Long For Necessary Nos. Of Provided Insulators And Erecting On Pole With 50X6mm Clamp Complete As Per Specification No. Oh-Pl / Bkt 126 Supplying & Erecting Ms Pole Bracket For Guarding / Lt Oh Line, Fabricated From Ism Channel 75X40x6mm And 1100Mm Long For Necessary Nos. Of Provided Insulators And Erecting On Pole With 50X6mm Clamp Complete As Per Specification No. Oh-Pl / Bkt 127 Supplying And Erecting V Cross Arm With Ism Channel Of 100X50x6mm Or 22 / 33Kv Ht Oh Line With Arrangement To Fix Insulator At 45Mm From The End & Horizontal Distance Between Insulators 1530Mm Bent At Angle Of 60 Degree Keeping Base 310Mm And The Total Vertical Height Of V Cross Arm As 460Mm, And Fixed On Pole With Ms Clamp Of 80X10 Mm, Nut Bolts, Washers Complete As Per Specification No. Oh-Pl / Vca 128 Supplying And Erecting 75X40 X6mm With 4.4Mm Thick Web And 7.3Mm Thick Flange Channel ( Top Pin ) With Clamp Of Suitable Length So As To Maintain Vertical Clearance Of 1065Mm For 11Kv, 1320Mm For 22Kv Between Insulators For Erection Of Top Pin Insulators Complete As Per Specification No. Oh-Pl / Vca 129 Supplying & Erecting Single Pole Cut Point Channel Set Of For 11Kv Ht Oh Line Two Channel Of Size 100X50x6mm 1.6M Long Having Stud Angle Of Size 50X50x6mm 1.5M Long With Necessary Clamps, Nut Bolts Etc. Complete As Per Drawing 130 Supplying And Erecting All Aluminium Stranded Conductors 7 / 2.21 Mm. Complete. ( Gnat ) ( 73.77Kg / Km ) As Per Specification No. Oh-Con / Aac 131 Supplying And Erecting All Aluminium Stranded Conductors 7 / 3.10 Mm. Complete. ( Ant. ) ( 145.0 Kg / Km ) As Per Specification No. Oh-Con / Aac 132 Supplying And Erecting Acsr Conductor Of Size 6 / 1-2.59 Mm Complete. ( Weasel ) ( 127.7 Kg / Km ) As Per Specification No. Oh-Con / Acsr 133 Supplying And Erecting Pin Type Lt Medium Insulator 100Mmx 62Mm Dia. With Suitable G.L. Spindle, Nut, Bolts Complete 134 Supplying And Erecting Aluminium Bobbin With G.L. ( Shackle ) Strip, Nuts Complete. 135 Providing And Fixing Gi Earthing Stud With Necessary Materials 136 Supplying And Erecting Porcelain Disc Type Insulator 45Kn With Necessary Hardware Suitable For 11Kv Line, Complete As Per Specification No. Oh-Ins / Di 137 Supplying And Erecting Porcelain Pin Type Insulator With Gi Pin Suitable For 11Kv Line, Complete As Per Specification No. Oh-Ins / Pn 138 Supplying And Erecting Distribution Class, 11 Kv Thyrite Type Lightening Arrester With Nut Bolts, On Provided Ms Channel As Per Specification No. Oh-Ins / La 139 Supplying And Erecting G.I. Fly Stay Set For Pole Including Straining Screw, G.L. Stay Wire, 7 / 10 Swg ( For To 15M Long ) With Pole Clamp, Made Of 50X6mm Ms Flat, Erected On Provided Rsj Pole Complete. ( Add. Rs. 25 / - Per M For Extra Length Beyond 15 M ) 140 Supplying And Erecting Guarding Loop Using G.L. Wire No. 8Swg For Lt Oh Line Of Horizontal Formation Erected With 20Swg G.L. Wire As Binding Wire And 50Mm Section On Each Side Complete. 141 Supplying And Erecting Fibre / Pvc Spacers For Lt Overhead Line 3 To 5 Conductors Complete Erected. 142 Supplying And Erecting Pole Clamp Made From 50X10mm Ms Flat For Pole Or Pipe, Post Erected With 15Mm Bolts And Nuts Duly Painted With One Coat Of Red Oxide And Two Coats Of Aluminium Paint Complete. 143 Supplying And Erecting ‘D’ Type Pole Clamps, Fabricated From 50X6mm Ms Flat With 15Mm Bolts And Nuts Fixed To Steel Tubular Pole Duly Painted With One Coat Of Red Oxide And Two Coats Of Aluminium Paint Complete 144 Supplying And Fixing Ms Base Plate 30X30x0.6Cm Size Fixed To The Pole Base Either By Welding 12Mm Dia Fixed At Position 145 Supplying And Fixing Ms Round Base Plate 25Cm Dia And 10Mm Thick Fixed To Pole Welded And Fixed At Position 146 Dismantling The Existing Pole Above 6 M Height With Brackets, Clamps, Insulators, Stay From The C.C. Foundation And Making The Site Clear By Refilling The Pits With Excavated Materials And Bringing It To The Ground Level 147 Dismantling The Existing Overhead Line Including G.I. Wires Of All Sizes Without Damaging & Making The Coils In Suitable Sizes. 148 Providng Earthing With Galvanized Iron Earth Plate Size 60 X 60 X 0.6 Cm Complete With All Materials, Testing & Recording The Results As Per Specification No. Ea-Ep 149 Providing Pipe Type Earthing With 40Mm. Dia. G.I. Pipe Or 20 Mm Dia. G.I. Rod Complete With All Materials Testing And Recording The Results As Per Specification No. Ea-Ep 150 Supplying And Erecting 11 Kv Outdoor Type Gang Operated Air Break, Triple Pole Switch 200 A Capacity With 3 Post Pin Type Insulator Per Phase, Mounted In Horizontal Or Vertical Position With Necessary Channels On Provided Cross Arm With Adequate Length Of C Class G.L. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground Level With Necessary Clamp. 151 Supplying And Erecting 11 Kv Outdoor Type Gang Operated Air Break, Triple Pole Switch 400 A Capacity With 3 Post Pin Type Insulator Per Phase, Mounted In Horizontal Or Vertical Position With Necessary Channels On Provided Cross Arm With Adequate Length Of C Class G.L. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground Level With Necessary Clamp. 152 Supplying And Erecting 33 Kv Outdoor Type Gang Operated Air Break, Triple Pole Switch 200 A Capacity With 3 Post Pin Type Insulator Double Stack Per Phase, Mounted In Horizontal Position With Necessary Channels On Provided Cross Arm With Adequate Length Of C Class G.L. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground Level With Necessary Clamp 153 Supplying And Erecting, 11 Kv Outdoor Type Drop Out Fuse With Insulator Complete With Fuse Holders, Fuse Barrel With Metal Fitting, Fuse Element Mounted On M.S. Channel With Working Current Of 15A Capacity Complete Erected On Provided Cross Arm 154 Supplying And Erecting, 33 Kv Outdoor Type Drop Out Fuse With Insulator Complete With Fuse Holders, Fuse Barrel With Metal Fitting, Fuse Element Mounted On M.S. Channel With Working Current Of 15A Capacity Complete Erected On Provided Cross Arm. 155 Supplying And Erecting 11 Kv Fuse Barrel With Metal Fittings Complete 156 Supplying Heavy Duty Operating Rod, Outer Dia 25 Mm & Inner Dia 20 Mm Suitable For 11 Kv With Brass Couplings Etc. For Removing Drop Out Fuses At 6 Meters Length, 4 Pieces Each With Rain Shade With Hand Grip Including Earthling Chain 1.5M Complete 157 Supplying And Erecting Copper Tubular Bus 20 Mm Dia 1.6 Mm ( 16 Swg ) Thick For The Use Of High Tension Over Head Bus And Erected On Provided Ht Insulators With Clamps, Nuts And Bolts Complete. ( Weight Per Meter Of Bus Is About 1.7 Kg. ) 158 Supplying, Erecting, Testing And Commissioning Of Microprocessor Based Amf Panel Suitable For Diesel Generating Set Of Up To 10 Kva Capacity Single / Three Phase, 230 / 415 Volts, 50Hz A.C. With All Standard Features, Safeties Etc As Per Specification No. Gen-Amf. 159 Carrying Out Servicing Of Dg Set Up To 50 Kva With / Without Amf Panel Of Any Make To Ensure Smooth Running Of Dg Set For 30 Mins On Load. Checking For Abnormal Sound And Leakages, Carry Out Visual Inspection Of All Moving Parts, Oil Levels, Oil Filters, Fuel Filters, Air Filters And Clean Them Properly, Rectify The Minorleakages If Any. Inspect Alternator, Stator And Rotor For Normal Speed & Proper Frequency, Examine Battery Charging With Monitoring System And Recording Voltages, Checking Battery Cells Gravity And Topping Up With Distilled Water, Checking V Belts With Necessary Adjustment, Checking And Retightening Of Nut Bolts Including Coupling Bolts Of Engine And Alternator, Checking & Cleaning Of Radiator And Leakage Testing Checking Of Radiator & Fuel Supply Hose Pipes, Checking Of Avr, Excitation Diodes, Its Connections Confirming Proper Output Voltage. Checking & Resetting Of Valve Tappets, Cleaning Of Dg Set Internally Using Blower, Cleaning Radiator, Attending Breakdowns As And When Required During One Month Period Or During Vip Visit Within 2 Hours Of Intimation And Submit The Servicing Report To Engineer In Charge. ( Non Comprehensive ) As Per Specification No. Gen-Ser-Amc 160 Making Trench In Soft Soil Having 0.75 M Depth And Minimum 0.3 M Width For Laying Provided Cables Up To Voltage Level Of 1.1Kv Complete As Per Specification No. Cw-Exn-Ctr 161 Making Trench In Hard Murum / Tar Road Having 0.75 M Depth Andminimum 0.3Mtr Width As Per Is For Laying Provided Cables Up To Voltage Level 1.1Kv Cable Complete As Per Specification No. Cw-Exn-Ctr 162 Making Cement Concrete Foundation Including Excavation ( 60 X 60 X 150 ) Cm Deep In 1:3:6 Cement Concrete 20 X 25 Mm Stone Metal, ( 45 X 45 X 45 ) Cm / 45 Cm Dia. X 45 Cm Height Plinth Duly Plastered, With Necessary Curing And Finishing Complete. ( Above 6 M To 9 M Poles ) 163 Making Cement Concrete Foundation Including Excavation ( 60 X 60 ) Cm X Deep 1 / 6 Of Pole Length In 1:3:6 Cement Concrete 20 X 25 Mm Stone Metal, 45 Cm X 45 Cm X 45 Cm / 45 Cm Dia. X 45 Cm. Height Plinth Duly Plastered, With Necessary Curing And Finishing Complete. ( For Above 9 M Poles ) 164 Making Cement Concrete Foundation Including Excavation ( 60 X 60 X 150 ) Cm Deep In 1:3:6 Cement Concrete, ( 20 To 25 ) Mm Stone Metal With Necessary Curing And Finishing Complete. ( For Stay ) . 165 Making Cement Concrete Foundation In 1:3:6 Cement Concrete, ( 20 To 25 ) Mm. Stone Metal Duly Plastered With Necessary Curing For Complete. ( Pole Muffing Or Any Other Purpose ) .