| 1 | Taking down carefully unserviceable Ceiling Fan of any size from its position, dismantling blade, opening the fan motor, removing the burnt grease, applying new bearing grease, removing of defective parts such as ball bearing, bush bearing, burnt winding, shaft, split pin, condenser, condenser holder, shackle etc. reassembling after replacement of defective parts including replacement of 3 core 0.75 Sqmm flexible copper cable from ceiling rose to connector, hanging in its position properly complete all as specified and directed.Note:- Replacement of unserviceable spare parts shall be measured and paid separately under respective items of this schedule here-in-after as supply only. |
| 2 | Description all as per Sl item No 1.00 but for exhaust fan of any size |
| 3 | Description all as per Sl item No 1.00 butPedestal fan of any size. |
| 4 | Supply only ball bearing of existing size suitable for ceiling fan, exhaust fan, fresh air fan, pedestal fanas that of existing defective one complete all as specified and directed.(Make : Tata/SKF/NBC) |
| 5 | Supply only bush bearing of existing size suitable for ceiling fan, exhaust fan, fresh air fan and pedestal fan ofcomplete all as specified and directed. |
| 6 | Supply only condenser 2.5 MFD complete all as specified and directed.(Make : Usha/Keltran/uptran) |
| 7 | Supply only condenser 4 MFD complete all as specified and directed.(Make : usha/Keltran/uptran) |
| 8 | Material and labour for cleaning and preparing the surfaces of ceiling fan, removing the grease, carbon dust over the fans and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan complete all as specified and directed. |
| 9 | Material and labour for cleaning and preparing the surfaces ofexhaust fan removing the grease, carbon dust over the fans and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan complete all as specified and directed. |
| 10 | Rewinding the stator complete with super enamelled bare copper conductor with the existing size/gaugeand number of turns as that of the old one, insulating, varnishing and pre heating for ceiling fan 1200mm/1400mm sweep complete all as specified and directed. |
| 11 | Description all as per Sl No 10 .00 here in before but Exhaust fan upto 300mm sweep. |
| 12 | Description all as per Sl No 10 .00 here in before but Exhaust fan above 300mm upto 450mm sweep. |
| 13 | Description all as per Sl No 10 .00 here in before butPedestal fan upto 300mm sweep. |
| 14 | Removing the damaged and corroded exhaust fan louvers and replace with new louvers of size up to 300mm sweep complete all as specified and directed. |
| 15 | Removing the damaged and corroded exhaust fan louvers and replace with new louvers of size above 300mm and up to 450mm complete all as specified and directed. |
| 16 | Removing the damaged and corroded exhaust fanblades and replace with new blades of size up to 300mm sweep complete all as specified and directed. |
| 17 | Removing the damaged and corroded exhaust fan blades and replace with new blades of size above 300mm and up to 450mm complete all as specified and directed. |
| 18 | Taking down defective storage water heater of any capacity from buildings after disconnecting carefully water and electric connection, opening the bottom cover replacing the defective parts fixing the cover and refixing in original position reconnecting both water and electric connection and testing complete all as specified and directed.Notes :- Replacement ofspareswill be measured and paid for separately under respective items of the schedule here-in-after as supply only. |
| 19 | Supply only new heating element of capacity 1.5KW with rubber gasket complete all as specified and directed. |
| 20 | Supply onlynew heating element of capacity 2 KW with rubber gasket complete all as specified and directed. |
| 21 | Supply only thermostat suitable for storage type water heater complete all as specified and directed. |
| 22 | Supply only 3 core 2.5 Sqmm copper conductor cable suitable for geysers of any size complete all as specified and directed.(Make : Finolex/Anchor/Plaza) |
| 23 | Supply only Non return valve 15mm dia suitable for geyser complete all as specified and directed. |
| 24 | Supply and fix Metal socket single pole and neutral with two pin and earth socket complete with one single pole MCB 25 Amps complete all as specified and directed.(Make : L&T/Legrand/ ABB/ Siemens/ Schneider/ Havells) |
| 25 | Supply and fix 3 pin plug top suitable for metal socket of capacity 25 Amps complete all as specified and directed.(Make : Standard/Havells/Anchor) |
| 26 | M&L for preparing external surfaces of water heater, cleaning and painting with one coat of synthetic enamel paint of white colour of approved make with brush and writing MES No. complete all as specified and directed. |
| 27 | Supply onlyApparatus plate assembly suitable to fix thermostate, heating elements as ofgeyser and nuts etc complete all as specified and directed. |
| 28 | Supply only Flexible Pipe |
| 29 | Removing thetank from the geyser, brazing to arrest the leakage, reassembling and refixing complete all as specified and directed. |
| 30 | Supply only Bottom inspection chamber cover suitable for 25 Ltrs capacity geyser of any make/model complete all as specified and directed. |
| 31 | Supply only Indication lamp suitable for geyser in round/rectangular shape complete all as specified and directed. |
| 32 | Supply and replace 3 pin plug 15 Amps capacity complete all as specified and directed.(Make : Anchor/Plaza) |
| 33 | Supply onlygeyser tankof capacity 15 Ltrs made out of stainless steel complete all as specified and directed. |
| 34 | Supply onlygeyser tank of capacity 25 Ltrs made out of stainless steelcomplete all as specified and directed. |
| 35 | Supply and fix in repair electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and directed. |
| 36 | Supply and fix in repairmetal meter box, suitable for two nos meter Single piece moulded without any joints,Concealed metal hinges, Mounting screws fitted from inside, Adequate space for meter and cut-outs,Weatherproof complete all as specified and directed. |
| 37 | Supply and fix in repair metal meter box, suitable for 4 nos meter Single piece moulded without any joints,Concealed metal hinges, Mounting screws fitted from inside, Adequate space for meter and cut-outs,Weatherproof complete all as specified and directed. |
| 38 | Supply and fix in repairmetal meter box, suitable for 6 nos meter Single piece moulded without any joints,Concealed metal hinges, Mounting screws fitted from inside, Adequate space for meter and cut-outs,Weatherproof complete all as specified and directed. |
| 39 | Supply and fix in repairmetal meter box, suitable for 8 nos meter Single piece moulded without any joints,Concealed metal hinges, Mounting screws fitted from inside, Adequate space for meter and cut-outs,Weatherproof complete all as specified and directed. |