}

Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Creation Of63 Kva And 25Kva Sub Stations Along With Erection Of 11 Kv Line On 9 Mtr. Longst Poles, 30Mm Sqacsr Weasel Conductor & Lt Line On 8 Mtr. St Poleat Wss Peoni U, peoni-Jammu And Kashmir

Power Development Department has published Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Creation Of63 Kva And 25Kva Sub Stations Along With Erection Of 11 Kv Line On 9 Mtr. Longst Poles, 30Mm Sqacsr Weasel Conductor & Lt Line On 8 Mtr. St Poleat Wss Peoni U. Submission Date for this Tender is 13-03-2024. Bolts Tenders in peoni Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

42370892
Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Creation Of63 Kva And 25Kva Sub Stations Along With Erection Of 11 Kv Line On 9 Mtr. Longst Poles, 30Mm Sqacsr Weasel Conductor & Lt Line On 8 Mtr. St Poleat Wss Peoni U
Open Tender
Indian
Jammu And Kashmir
Peoni
13-03-2024

Tender Details

Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Creation Of63 Kva And 25Kva Sub Stations Along With Erection Of 11 Kv Line On 9 Mtr. Longst Poles, 30Mm Sqacsr Weasel Conductor & Lt Line On 8 Mtr. St Poleat Wss Peoni Under Jjm On Turnkey Basis- 1 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 11 Kv Line On 9 Mtr. Long St Poles, 30Mm² Acsr Conductor At Wss Peoni Stage Amb Bhag. 2 9 Mtr. Long St Pole ( St-410 Sp-33 ) 3 Gi V Cross -Arm With Top Bracket Including Clamps 4 Gi Channel X-Arm Including Clamps And Angle For Braces 5 30Mm² Acsr Weasel Conductor 6 11 Kv Go Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical 7 Pg Clamps 8 11 Kv Polymer Composite Pin Insulator 12 Kv, 5 Kn, Lighting Impulse 75 Kv Positive And 80 Kv Negative, Creepage Distance 320Mm. 9 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45 Kn, Lightening Impulse 75Kvpositive And 80 Kv Negative, Creepage Distance 320Mm With Fitting 10 Galvanized Nuts And Bolts 11 Danger Plates With Clamps 12 Anti Climbing Device With Clamps 13 Earthing Complete Bygi Rod 20 Mm, 2.5 Mtr Long Through G.I. Strip 25X3 Mm 14 Painting Of 9 Mtr St Poles With One Coat Of Red Oxide Paint 15 Painting Of 9 Mtr St Poles With Two Coats Of Aluminiumpaint. 16 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 17 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 18 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Installation Of 63 Kvaat Wss Peoni Stage Amb Bhag 19 11 / 0.433 Kv, 3-Phase Distribution Transformer 63 Kva With Bimetallic Terminal Connectors Energy Level-2 Aluminium Wound, & With Lv Cable Box Having Detachable Aluminium Gland Plate 20 Gapless Surge Arrestor, 9 Kv, 10 Ka , La With Polymer Housing Stn. Type 21 11 Kv Go Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical 22 11 Kv Horn Gap Fuse Set 3 Phase 200 A 23 120Mm² 1.1 Kv Grade, Pvc Insulated Stranded Conductor Frls Type 24 9 Mtr. Long St Poles ( St-410 Sp33 ) 25 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45 Kn, Lightening Impulse 75Kvpositive And 80 Kv Negative, Creepage Distance 320Mm With Fitting 26 Gi Channel / Angle / Flat Of Sizes Including Clamps 27 Galvanized Nuts And Bolts. 28 Earthing Of Sub Stn. Excavation Of Earth Pit Of Dia 650Mm & Depth 3000Mm Installation Of Earthing Pipe Of 40Mm Nominal Bore & 4Mm Wall Thickness & Length 2.5 Mtr. Long As Per Is 1239. G.I Strip For Neutral Earthing Of Size 25Mmx3mmfor Connection Of Transforemr Body, Go Set & Lightening Arrestor As Per Is 2629 / 85, Gi Nuts & Bolts Refilled With Earth Enhancement Materials And Earth Chamber With Rcc Slab Cover 29 11 Kv Polymer Composite Pin Insualtor, 12 Kv, 5Kn Lightening Impulse 75 Kv Positve And 80 Kv Negative, Creepage Distance 320Mm 30 Lt Distribution Box For 63 Kva Dtr With Mccb For Incomer And SfuS For Outgoing Circuits 31 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 32 Pg Clamps 33 Danger Plates With Clamps 34 Gi Barbed Wire For Anticlimbing 35 3-Phase 4 Wire Lt Prodigy Meter With Box. 36 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 37 Painting Of St Poles 9 Mtr. Long With1 Coat Of Red Oxide And2 Coat Of Aluminum Paint. 38 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 3 Phase 4 Wire Lt Line On 8 Mtr. St Poles At Wss Peoni Stage Amb Bhag. 39 8 Mtr. Long St Poles ( St-410 Sp15 ) 40 Gi M Clamps For Shackle Insulator 41 30Mm²acsr Weasel Conductor 42 Shackle Insulator 43 Galvanized Nuts And Bolts. 44 Danger Plates With Clamps 45 Anti Climbing Device With Clamps 46 Earthing Complete Bygi Rod 20Mm 2.5 Mtr. Long Through Gi Strip 47 Painting Of St Poles 9 Mtr. Long With1 Coat Of Red Oxide And2 Coat Of Aluminum Paint. 48 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 49 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 11 Kv Line On 9 Mtr. Long St Poles, 30Mm² Acsr Conductor At Stage Puna. 50 9 Mtr. Long St Pole ( St-410 Sp-33 ) 51 Gi V Cross -Arm With Top Bracket Including Clamps 52 Gi Channel X-Arm Including Clamps And Angle For Braces 53 30Mm² Acsr Weasel Conductor 54 11 Kv Go Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical 55 Pg Clamps 56 11 Kv Polymer Composite Pin Insulator 12 Kv, 5 Kn, Lighting Impulse 75 Kv Positive And 80 Kv Negative, Creepage Distance 320Mm. 57 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45 Kn, Lightening Impulse 75Kvpositive And 80 Kv Negative, Creepage Distance 320Mm With Fitting 58 Galvanized Nuts And Bolts 59 Danger Plates With Clamps 60 Anti Climbing Device With Clamps 61 Earthing Complete Bygi Rod 20 Mm, 2.5 Mtr Long Through G.I. Strip 25X3 Mm 62 Painting Of 9 Mtr St Poles With One Coat Of Red Oxide Paint 63 Painting Of 9 Mtr St Poles With Two Coats Of Aluminiumpaint. 64 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 65 Al. Jointing Sleeves 66 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 67 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Creation Of 25 Kva Sub Stn. At Wss Puna. 68 11 / 0.433Kv, 3-Phase 25 Kva Distribution Transformer With Bimetallic Terminal Connectors Energy Level-2, Aluminium Wound, And With Lv Cable Box Havingdetachable Aluminium Gland Plate 69 Gapless Surge Arrestor 9Kv, 10Ka, La With Polymer Housing Station Type 70 11 Kv Go, Ab Switch 3 Phase 3 Pole 200 Amp Vertical 71 11 Kv Horn Gapfuse Set 3 Phase 200A 72 95 Mm² Single Core Cable, 1.1Kv Grade, Pvc Insulated Alumnium Stranded Conductor Frls Type 73 9 Mtr. Long St Pole ( St-410 Sp33 ) 74 11Kv Polymeric Composite Disc Insulator 12Kv, Min Failing Load 45Kn, Lightening Impulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm With Tension Fitting 75 Gi Channel / Angle / Flat Of Sizes Including Clamps 76 Galavinized Nuts And Bolts. 77 Lt Fuse Set Made 50X6mm Angle Iron And 50X6mm Aluminium Bus Bar Strip Fixed On Bus Bar Insulator. 78 Cement Bottoming 1:2:4 Mix As Per Rec Standards 0.5 Cum Per Pole 79 Earthing Of Substation --Excavation Of Earth Pit Of Dia 650 Mm & Depth 3000 Mm, Installation Of Earthing Pipe Of 40 Mm Nominal Bore & 4Mm Wall Thickness & Length 2.5 Mtr Long As Per Is 1239. Gi Strip For Neutral Earthing Of Size 50 Mm X 6 Mm & 32Mm X 3Mm For Connection Of Transformer Body, G.O Set & Lightening Arrestor As Per Is 2629 / 85, Gi Nuts & Bolts, Refilled With Earth Enhancement Materials And Earth Chamber With Rcc Slab Cover.

Key Value

Document Fees
INR 2000 /-
EMD
INR 143300.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail