Supplying Of All Materials, Labour, T&P For Erection , Installation, Testing & Commissioning Of 11 / 0.4Kv 25Kva Dp Mounted S / S = 1 No. ( Handed Over To Tpsodl ) With Proper Fancing, New To 3Ph - 3W, 11 Kv Oh Line = 0.035Kms. ( 2 Span, 1 Spare Ckt ) Using 3X35 Mm2 11Kv Xlpe Cable With 1 No. 9 Mtrs. Long Psc Pole & 1 No. 10 Mtrs. Long Psc Pole For Tapping, Construction Of 11Kv Dp With Ab Switch Using 9 Mtrs. Long Psc Pole & Service Connection 30Mtrs. = 1 No.For 3 Ph Power Supply To Proposed Load Of 07Kw Of Belagada Under Sanakhemundi Block- 1 Supplying Of All Materials, Labour, T&P Forerrection, Installation, Testing & Commissioning Of 11 / 0.4Kv 25Kva Dp Mounted S / S = 1 No. ( Handed Over To Tpsodl ) With Proper Fancing Including Stock, Storage & Insurance, Transporation ( As Per Rec Standard ) And As Per Requirement Of Tpsodl 2 10 Mtr Long, 330 Kg, Psc Pole. 3 Gi Base Plate. 4 Pressure Channel Gi ( 100X50x6 ) Mm. ( 9.20Kg / Mtr ) X 2.80 Mtr.Each X 2 Nos 5 Ab Switch & Hg Fuse Mounting Channel G.I. ( 75X40x6 ) Mm 2.8 Mtr Long 4Nos ( 6.8 Kg. / Mtr. ) 6 Transformer Mounting Channel Gi 100X50x6mm ( 9.20Kg / Mtr. ) X 2.80 Mtr. Each X 2 Nos 7 Transformer Belting Angle Gi ( 50X50x6 ) Mm 7Mtr ( 4.5 Kg. / Mtr. ) 8 Lt Distribution Box Mounting Angle Gi ( 50X50x6 ) Mm ( 4.5 Kg. / Mtr. ) 9 200 Amp 3 Pole Ab Switch 10 200 Amp 3 Pole Hg Fuse 11 La ( 9Kv, 10Ka Class ) 12 Birdproof Cap For 9Kv La 13 11 Kv Pin Insulator Polymer 14 Disc Insulator ( T & C ) 45 Kn Polymer 15 Hw Fitting ( T&C ) 45Kn 16 Ht Stay Set Complete 17 Ht Stay Wire ( 7 / 10 Swg ) 18 Ht Stay Insulator 19 Ht Stay Clamp ( 1.9Kg / Pair ) 20 Pipe Earthing Device 40Mm Dia Medium Gauge 3Mtr Long 21 25X6 Mm Gi Flat ( For Others ) 22 25X4 Mm Gi Flat ( For Lightening Arrester ) 23 Lt Distribution Box Including Kit Kat Fuse 24 25Kva11 / 0.4Kv ( Al ) Transformer Bis Energy Level-Ii 25 Earthing Device Coil Type ( Gi ) 26 G.I Nuts., Bolts & Washer. 27 55 Mmsq Aaa Conductor For Jumpering 28 50 Mm23 & 1 / 2 Corelt Pvc Cable 29 Danger Board 30 Gi Clamp For Danger Board Gi Flat ( 25X3 Mm @ 0.60Kg / Mtr ) 510Mm Length ( 0.306Kg / Piece ) 31 Gi 2Ply 2.5Mm Dia Barbed Wire For Antyclimbing Device 32 Gi Back Clamp For Anticlimbing Devices 25X3 Mm Flat ( 0.6Kg / Mtrs ) Flat Of 510 Mtrs Length = 4 Nos. ( 1.22Kg / Pole ) 33 Sundries ( Painting, Clamp, Connector & Jumpering Materials ) 34 Supplying Of All Materials, Labour, T&P For New To 3Ph - 3W, 11 Kv Oh Line = 0.035Kms. ( 2 Span, 1 Spare Ckt ) Using 3X35 Mm2 11Kv Xlpe Cable With 1 No. 9 Mtrs. Long Psc Pole & 1 No. 10 Mtrs. Long Psc Pole For Tapping, Including Stock, Storage & Insurance, Transporation ( As Per Rec Standard ) And As Per Requirement Of Tpsodl 35 300 Kg, 9 Mtr Long, Psc Pole. 36 300 Kg, 10 Mtr Long, Psc Pole. 37 11Kv F Clamp ( With Galvanisation ) 38 11Kv V Cross Arm ( 10.20Kg. Each ) ( With Galvanisation ) 39 Gi Back Clamp For V Cross Arm ( 11Kv ) ( 0.85 Kg. Each ) 40 Disc Insulator ( T & C ) 45 Kn Polymer 41 Hard Ware Fitting ( T&C ) 45Kn 42 11 Kv Pin Insulator Polymer 43 100X50x6 Mm.Gi Channel ( 9.20Kg / Mtr ) 44 3 X 35 Mmsq 11 Kv Xlep Cable 45 Heat Srinkable Jointing Kit 3 Core 35 Mm2 11Kv Xlep Cable ( Out Door Type ) 46 Lightening Arrester ( 9Kv, 10Ka ) At Xlpe Cable Tapping 47 Birdproof Cap For 9Kv Surge Arrester 48 75X40x6 Mm, Gi Channel For La 49 Strining Of 11Kv Xlpe Cable On Overhead Wit 7 / 12 Swg Gi Stay Wire & Clamp, Connectors & Strain Fittings, Channel Etc., ( Double ) 50 Gi Earthing Electrod 40 Mm Dia Medium Gauge For La & Xlpe 51 Gi Flat 25X6 Mm 52 Ht Stay Set Complete 53 Ht Stay Insulator 54 Ht Stay Clamp ( 1.9Kg / Pair ) 55 7 / 10 Swg Gi Stay Wire 56 Earthing ( Coil Type ) For Support 57 Pg Clamp For 55 Mmsq Aaa Conductor 58 G.I Nuts., Bolts & Washer. 59 Gi 2Ply 2.5Mm Dia Barbed Wire For Antyclimbing Device 60 Gi Back Clamp For Anticlimbing Devices 25X3 Mm Flat ( 0.6Kg / Mtrs ) Flat Of 510 Mtrs Length = 4 Nos. ( 1.22Kg / Pole ) 61 Gi Base Plate. 62 Danger Board 63 Gi Clamp For Danger Board Gi Flat ( 25X3 Mm @ 0.60Kg / Mtr ) 510Mm Length ( 0.306Kg / Piece ) 64 Guarding For Road Crussing 65 Pipe Earthing Device 40Mm Dia Medium Gauge 3Mtr. Long 66 No. 6 Gi Wire For Earthing 67 Sundries. 68 Supplying Of All Materials, Labour, T&P For Erection, Installation, Testing, Commissioning Of Construction Of 11Kv Dp With Ab Switch Using 9 Mtrs. Long Psc Pole Including Stock, Storage & Insurance, Transporation ( As Per Rec Standard ) And As Per Requirement Of Tpsodl 69 300 Kg, 9 Mtr Long, Psc Pole. 70 Pressure Channel Gi ( 100X50x6 ) Mm. 2.80 Mtr. 2 Nos ( 9.20Kg / Mtr ) 71 Ab Switch Mounting Channel & Bracing Channel G.I. ( 75X40x6 ) Mm 2.8 Mtr Long 4Nos ( 6.8 Kg. / Mtr. ) 72 Cross Bracing ( 50X50x6 ) Mm Angle G.I. 4 Mtr Long 2Nos ( 4.50 Kg. / Mtr. ) 73 Supporting Channel For Ab Switch Handle ( 75X40x6 Mm G.I. Channel ) 0.60 Mtr Long 1No ( 6.8 Kg. / Mtr. ) 74 Disc Insulator ( T & C ) 45 Kn Polymer 75 Hw Fitting ( T&C ) 45Kn 76 Pg Clamp For 55 Mmsq Aaa Conductor 77 11 Kv Pin Insulator Polymer 78 Lightning Arrester ( 9Kv, 10 Ka ) Station Class 79 11 Kv Ab Switch 3 Pole 400 Amp ( Hz ) 80 Ht Stay Set Complete 81 Stay Insulator 82 Stay Clamp 83 7 / 10 Swg Gi Stay Wire 84 Earthing Coil Type For Support / Pole 85 Danger Board 86 Gi Clamp For Danger Board Gi Flat ( 25X3 Mm @ 0.60Kg / Mtr ) 510Mm Length ( 0.306Kg / Piece ) 87 Gi Base Plate. 88 G.I. Nuts, Bolts & Washers 89 G.I. Barbed Wire Anticlimbing Device 2Kg Per Support 90 Gi Back Clamp For Anticlimbing Devices 25X3 Mm Flat ( 0.059Kg / Mtrs ) Flat Of 0.510 Mtrs Length = 4 Nos. / Pole ( 1.22Kg. / Pole ) 91 Gi Pipe Earthing Device 40Mm Dia Medium Gauge 3Mtr Long 92 No. 6 Gi Wire For Earthing 93 Saundries 94 Supplying Of All Materials, Labour, T&P For Erection, Installation, Testing, Commissioning Etc. Of Service Connection 30Mtrs. = 1 No. For 07 Kw Loadincluding Stock, Storage & Insurance, Transporation ( As Per Rec Standard ) And As Per Requirement Of Tpsodl 95 35 Mm Sq 31 / 2 Core Pvc Cable 96 No. 8 Swg 4.06Mm Dia Wire 97 63 Amp Kitkat Fuse 98 G.I. Service Conecton Bracket 99 Sundries. 100 Supplying All Materials, Labour, T&P For Construction Of Civil Works. 101 Cement Concreting For Stud & Stay Anchor Plat C.C. 1:3:6 By Using 4Cm Size Hard Granite Metal = ( 0.45Mx0.45Mtrx1.5 ) M = 0.3Cum @ 4158.84 =0.3037Xrs.4158.84 = Rs.1263.03 Or Rs.1270.00 102 Padding & Concreteingfor Supportc.C. 1:3:6 By Using 40Mm Size Hard Granite Metal = ( 0.45Mx0.45Mtrx1.5 ) M = 0.3037Cum @ 4158.84 =0.3037Xrs.4158.84 = Rs.1263.03 Or Rs.1270.00. 103 Coupling For Support With C.C. 1:3:6 By Using 12Mm Size Hard Granite Chips = ( 0.30Mx0.30Mtrx0.45M ) = 0.0405 Cum @ Rs 4754.71 / Cum. = 0.0405 X Rs 4754.71 = Rs.192.57 =Or Say Rs.193.00 104 Materials For Masonry Work For Earth Pit, Charcoal, Salt Etc, . Earthing Chamber Size ( 2X2 ) Rcc Slab Cover. 105 Supplying Of All Materials, Labour, T&P For Construction Of Fencingworks. 106 Rcc Pillar 107 3Ply 2Mm Gi Barbed Wire 108 Coupling Of Pillar ( 15X15X180 With Propor Rcc Concrete ( Including Supply Of All Materials & Labour ) 109 Grill Gate & Locking Arrengment 110 4 Sand Spreading ( Including Supply & Labour ) 111 4 Metal Spreading ( Including Supply & Labour ) 112 Supplying Of All Materials, Labour, T&P Forinstallation, Fitting, Fixing, Testing, Commissioning Etc. Of Internal Wiring Torwss Pump House Including Stock, Storage & Insurance, Transporation ( As Per Rec Standard ) And As Per Requirement Of Tpsodl & Rwss. 113 Iron Frame Of Size 3-0X4-6 Made Out Of Flat Angle Wall Mounted For Fixing Of Bus Bar, Kit Kat, 63A & 32A And Control Pannel Etc. 114 Supplying & Fixing Of 38 / 40 Mm Dia Gi Pipe Of Required Length As Per Ie Rulewith Perforated Holes From Bottom To Top & Upper End Threaded And Fitted With Suitable Flange For Making Connection Of Earth Continuity Wire Fixed By Gi Nut & Bolt And The Earth Pit Have An Altimate Layer Of Charcoal & Salt And Replastering The Grooved, Cutted Walls Of Pump House With Cement Mortar After Laying The Wire From Main Switch To Earth Electrods. 115 Supplying & Fixing Of 63A, 415V I.C. Tpn Main Switch With Fuse Unit, 2 Nos.Of 63Amp. 415V Kit Kat Fuse Mounted On The Iron Frame For Distribution Of Power Supply With Surface Wiring To Fase Indicator Point Fixing On Suitable Size Of Metalic Box With 3 Mm Thick Laminated Plate With All Accessories & Connection. 116 Supplying & Fixing Of 32 Amp 415V Tpn Main Switch With Double Fuse Unit, Fixed On Ms Frame With All Accessories Etc., Complete. 117 Supply , Fitting, Fixing Ofsuitable Wiringupto Single Phase Motor 2 Nos With 63Amp Main Switch, 32 Amp Main Switch 2 Nos With Suitable Bus Bar And 63Amp. Kit Kat Unit Indicator With Provision Of Light Point 3 Nos, Plug Point-1No, Fan Point-1No, And 2 Nos Earthing Device By Providing 16Amp, 230V D.P. Main Switch Fixed On Frame With Nut And Bolt Etc., Complete