}

Tender For Construction Of New Gym & Equipment For Kalyan Sangha Rani Rashmoni Ghat Road Bagmore Kanchrapara, North 24 Parganas District., North 24 Parganas-West Bengal

Government Departments has published Tender For Construction Of New Gym & Equipment For Kalyan Sangha Rani Rashmoni Ghat Road Bagmore Kanchrapara, North 24 Parganas District.. Submission Date for this Tender is 06-02-2024. Gym Equipment Tenders in North 24 Parganas West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

41783772
Tender For Construction Of New Gym & Equipment For Kalyan Sangha Rani Rashmoni Ghat Road Bagmore Kanchrapara, North 24 Parganas District.
Open Tender
Indian
West Bengal
North 24 Parganas
06-02-2024

Tender Details

Tender For Construction Of New Gym & Equipment For Kalyan Sangha Rani Rashmoni Ghat Road Bagmore Kanchrapara, North 24 Parganas District.- 1 Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary). (Payment to be made on area cleared) 2 Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm. 3 (c) Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS6313 (part -II) 1981. ( Mode of measurment will be per Sq.m of plan area of plinthtreated.) 4 Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation. 5 Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints withlocal sand. 6 Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) 7 Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. Pakur variety 8 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety 9 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (i)Tor steel/Mild Steel 10 Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. 11 Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. 12 Brick work with 1st class bricks in cement mortar (1:6)(b) In superstructure, ground floor 13 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor 14 Labour for Chipping of concrete surface before taking up Plastering work 15 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](i) With 1:6 cement mortar (b) 20 mm thick plaster 16 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](i) With 1:6 cement mortar (b) 15 mm thick plaster 17 Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m. 18 M.F. suspended ceiling made with 12.5 mm thick Gypsum plaster board including G.I. perimeter channel of 0.55 mm flush (having two flanges 20 mm and 30 mm respectively and web 27 mm ) along with perimeter of ceiling with G.I. intermediate channel of 0.9 mm thick size 45 mmx15mm placed at 750 mm c/c with G.I. ceiling angle of size 25 mmx10mmx0.55 mm thick fixed to the ceiling with G.I. Cleat and steel expansion fastener ceiling section 0.55 mm thick of size 51.50 mmx26mm fixed to the intermediate channels with the help of connecting clip and in the direction of perpendicular to the intermediate channel of 300 mm c/c 12.5 mm thick Gypsum plastered board are to be fixed under ceiling section as above by machine screws. The boards are to be joined and finished with jointing compound, paper tape and application of top coat etc. as per the direction of Engineer-in-charge. (The rate includes of cost of all materials including taxes, cost of accessories, fittings and fixtures, scaffolding and labour charges etc. complete) In ground floor 19 Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturers specification and as per direction of the EIC. In Ground Floor:(b) Two Coats 20 Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturers specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost ofprimer. In Ground floor (Two Coat)c) Super Protective100% Acrylic Emulsion. 21 Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturers specification and as per direction of the EIC. (In Ground Floor) (a) One Coat i) Water based interior grade Acrylic Primer 22 Protective and Decorative Textured exterior high class matt finish paint of approved quality, composed of special Tharmoplastic Resin containing fine crystalline additives derive from Granite as per manufacturers specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor Two Coat 23 Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) 24 Supplying, fitting & fixing UPVC pipesapproved brand pipes: (ii) 110 mm dia R.W.P 25 Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (e) Sal : Malayasian 26 Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In ground floor. (In case of non-supply of single plank, penal rate of reduction of 20% will be made)(i) 50mm thick shutters with 25mm thick panel of size 30 to 45 cm(a) Ordinary Teak Wood. 27 Iron socket bolt of approved quality fitted and fixed complete. (e) 300mm long x 10mm dia bolt. 28 Iron socket bolt of approved quality fitted and fixed complete. (b) 100mm long x 10mm dia bolt. 29 Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (i) 100mm. X 75mm. X 3.50mm. 30 Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (i) 75mm. X 60mm. X 3.15mm. 31 Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately)(a) 40mm X 6mm, 250mm Length 32 i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.(a) 250mm long 33 Iron catch hook of approved quality fitted and fixed to shutter and chowkat.(a) 6mm dia x 100mm long. 34 (A) Iron door ring of approved quality fitted and fixed with nut and washer complete. (i) 50mm dia. 35 Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. 36 (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary:(a) On timber or plastered surface :(iv) Two coats (with any shade except white) 37 (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i)Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. 38 Providing and fixing factory made door frame (single rebate) made of single piece extruded solid PVC profile with homogenous fine cellular structure having smooth outer integral skin having 62mm width x 32 mm thickness (the door frame is to be made with single piece extruded solid pvc profile whereas no sheet pasted profile shall be applied for door frame fabrication) and shall be fixed to wall as per instructions of Engineer – in – charge using 100 x 8 sheet metal CSK screws. 39 Supplying, Fitting & Fixing 30 mm thick thick both side prelaminated Double Leaf Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of approved make and manufacture, M.S. frame covered with 5 mm th. heat moulded PVC “C” channel of size 30 mm th, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on either sides forming styles; and 5 mm th. 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm tapered in 45 degree on the inner side to form top & bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel with 10 mm (5 mmx2) th.,20 mm wide cross PVC sheet as gap insert for top rail and bottom rail. Paneling of 5 mm th. both side PVC sheet to be fitted in the M.S. frame welded/sealed to the styles &rails with 7 mm (5 mm+2 mm) th.x15 mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive. An additional 5 mm th. PVC strip of 20 mm which is to be stuck on the interior side of the “C” channel using PVC solvent adhesive etc. complete excluding all necessary hardwares as per direction of Engineer-in-Charge. In ground floor 40 25 mm. thick damp proof with cement concrete (1:1.5:3) (with graded stone aggregate 10 mm. normal size) and painting the top surface with a coat of bitumen [VG.40 ] using 1.7 kg. per sq.m. including heating the bitumen and cost and carriage of all materials complete. [Bitument to be supplied by the Agency] 41 Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brand conforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) = 0.08 %] in floor, skirting etc. using polymerised adhesive of 6mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course and joints grouted with admixture of white epoxy grout materials of approved brand including spacer -2mm as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete as per direction of Engineerin-Charge.(Note: This work should not be executed without specific permission of Superintending Engineer)(b) ln Ground FIoor:(size not Iess than 800mmX 800 mm X 10.2 mm thick) 42 Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohrs hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturers specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor). b) In Ground Floor: Sizes-600 mm x600mm x10 mm with breaking strength > 1500 N 43 Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 m 44 Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-incharge.The rate includes the cost of labour, adhesive and all incidental charges thereof. In ground floor Glossy/Matt/Suede excluding surface texture or metallic lustre.(i) Thickness of laminate 1.5mm 45 Sanitary & Plumbing all total complete 46 Saupply, fitting & fixing Gym Equipments. (As per local market) 47 ELECTRICAL WORKSupply and fixing 240V, 30/32A, DP with fuse on line L&N Sheet steel Main Switches on flat frmae on wall (Make Standard) 48 Supplying and fixing double-door SPN MCB DistributionBoard Enclosure Supply & Fiing(2+8) way SPN MCBDB L&T with IP- 42/43 protection, concealed in wall after cutting the wall & mending Rood the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachmenta) 40A DP MCB Isolator & Necy. connection-1no, b) 6 to 32A SP MCB as required breaking capacity 10 KA &C characterstic--8 nos 49 Supplying and Drawing 1,1 KV Grade single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) of the following sizes alkathene pipe recessed in wall.A)2x4-1x2.5 sq mm through 25 mm alka pipe (SPNDB) 50 Distribution wiring in 1,1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire with 1x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) for ECC in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall for horizontal & vertical runs and in suitable size PVC casing-capping (Precision make) for ceiling portion only, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size Ph &N copper bar & earthing attachment flushed in wall incl. mending good damages to original finish [only PVC casing- capping on ceiling and remaining portion concealed] (Average run 8 mtr) 51 Distribution wriring in 1,1 KV Grade 3x1.5 sq single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in 19mm bor 3mn thick polythene pipe complete with all accesories embeded in wall to 240v6A 5 pin plug point inci. S&F 240V 6A 3 pin modular type plug socket & modular type switch (brand appr. by EIC) 52 Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block /round bakelite on wall/ceiling. 53 Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by ElC) on existing Modular Gl switch board with top cover plate incl. making necy. connections etc. 54 Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1x 4 SWGGI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F15 mm dia Gl pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven tO an average depth of 3.65 Mts. below the ground level as below (By ISI-Medium Gl pipe) 55 Fixing only single/ twin fluorecent light fiting complet with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastner. 56 Supplying and fixing of Box type fan clamp of 150 dia & 800 mm depth made of 16 SWG CRCA sheet withcone end duly sealed by cover, properly welded, incl. S&F 12 mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 Swg steel binding wire, incl. supplying & covering the box with alkathene sheet placed in order to prevent concrete from entering the box 57 Fixing only outdoor/street Iight type fluorecent light fiting or MV light Fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes/ providing camping arrangement & necy. GI reducer as required. S&F 40MM gi PIPE (ISI- Medium) quality 1.5 mts average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core standed annealed copper wire and making connections as required and mencing good damages to wall incl. painting etc. 58 Electrical Non Schedule Itemsof 4 20W single LED Tube light (make Crompton Cat. No. IGP 131 LTS- 16, 1X2OW LTT8-20W/ Philips) 59 Supply of 45W LED Compound light fittings with Ipô5 protection (Crompton:LSTP-45-CDL/PHILIPS) 60 Supply ,Fitting & fixing, 125mm round panel light complete with all acessaries incl S/F copper flex wire.(AS PER LOCAL MARKET) 61 Supply ,Fitting & fixing, LED STRIP complete with all acessaries inc S/F copper flex wire.(AS PER LOCAL MARKET) 62 Supply of 2 Nos A.C 2 Ton capacity complete with all acessaries incl S/F copper flex wire.(Rate taken from local market price) 63 Installation of Marbel Falak (Lumpsum)

Key Value

Document Fees
INR 2950 /-
EMD
INR 71100.0 /-
Tender Value
INR 35.54 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail