| 1 | M&L for construction of header made out of MS pipe of 300 mm dia, (Thickness of MS pipe not less than 12mm), 4 mtr length (In Two piece of each 2 mtr Length), A butterfly Valve 300 mm dia fixed centre of MS pipe with Flange, Flanges are tighten with nut bolts and two washers etc of suitable size and length complete and providing holes forfixing/welding MS pipe pieces with One flanged end for fixing of 02 Nos sluice valve of size 150 mm diaand 04 Nos of 100 mm dia. MS pipe should be fixed on PCC in foundation with PCC 1:3:6 type C1 (using 20 mm graded trap stone aggregate) (30 cm in below G.L & 30 cm above GL) & anchoring with MS strip at 03 place (MS strip should be grouted in PCC as suitable) and masonary block constructed with 230 mm thick bricks, sub class \"B\" bricks builts in cement mortar 1:4 and 15mm thick plastering to brick masonary in cement mortar, including Excavation and earth work complete all as specified and directed.Note (i) Quoted Rates are also included to fixing/welding ofMSpipes cut pieces as required size/type/length on site each for all 06 Nos inlet/outlet water supply pipeline connections & all type PCC foundation & Brick work complete (ii) All T&P, materials will be provided by the contractor without any extra cost. (iii) MS fittings like, Flange, Dead Plate, Bends, Reducers etc and Sluice/Butterfly valves should be measured and paid separetaly under appropriate items below. |
| 2 | Supply & Fix for Butterfly valve of size 300 mm and connected with necessary bolts, nuts & 02 Nos of washers, gaskets etc complete all as specified and directed. |
| 3 | Supply and fix in renewal 150mm dia cast iron sluice valve PN-1.6 conforming to IS 14846/2000, ISI Mark with MS spindle and iron wheel head with both ends flanged with new rubber gasket, bolts and nuts at any location complete all as specified and directed. |
| 4 | Supply and fix in renewal 100mm dia cast iron sluice valve PN-1.6 conforming to IS 14846/2000, ISI Mark with MS spindle and iron wheel head with both ends flanged with new rubber gasket, bolts and nuts at any location complete all as specified and directed. |
| 5 | Supply & Fix in renewal 150mm size for CI non return valve (NRV) conforming to IS 5312, ISI marked with GM flap and connected with necessary bolts, nuts & washers, gaskets etc complete complete all as specified and directed. |
| 6 | Taking up Cast iron water main (including all fittings) with spigot and socketed ends and lead joints including burning out lead joints for pipe of bore 100 mm complete all as specified and directed. |
| 7 | Taking up Cast iron water main (including all fittings) with spigot and socketed ends and lead joints including burning out lead joints for pipe of bore 150 mm complete all as specified and directed. |
| 8 | Taking up Cast iron water main (including all fittings) with spigot and socketed ends and lead joints including burning out lead joints for pipe of bore 300 mm complete all as specified and directed. |
| 9 | Supply, laying and testing DI pipes with double flanged ends centrifugally cast, class K-9 with cement mortor lining inside the pipes & Zinc coated out side as perIS8329/2000in any length fixed on pillar and wall of 300 mm bore sizes complete all as specified and directed. |
| 10 | Supply, laying and testing DI pipes with double flanged ends centrifugally cast, class K-9 with cement mortor lining inside the pipes & Zinc coated out side as perIS8329/2000in any length fixed on pillar and wall of 150 mm bore sizes complete all as specified and directed. |
| 11 | Supply, laying and testing DI pipes with double flanged ends centrifugally cast, class K-9 with cement mortor lining inside the pipes & Zinc coated out side as perIS8329/2000in any length fixed on pillar and wall of 100 mm bore sizes complete all as specified and directed. |
| 12 | M & L for Cutting of existing Cast iron pipes in position for insertion of bends (any type, radius and angle) Tapers any type (Straight bends, increasing, decreasing or double socket etc) Tee pieces, single branch \"Y\" junction,double branch, cross (all sockets or sockets & spigot) collars, Caps & plugs for flanged of pipes 150 mm dia bore branch connection etc complete all as specified and directed.Note : DI Special fittings shall be measured and paid separately |
| 13 | M&L forDI fittings such as bends (any type, radius and angle) Tapers any type (Straight bends, increasing, decreasing or double socket/flanged etc) Tee pieces, single branch \"Y\" junction,double branch, cross (all sockets or sockets & spigot/ all flanged/restrain Joint etc) collars, Caps & restrain flanges, plugs for spigot socketed/Flanged pipes upto 300 mm dia bore complete all as specified and directed. |
| 14 | Taking upor down steel tubing and connections including cleaning for refixing or removal to store of size 50 mm dia complete all as specified and directed. |
| 15 | Taking upor down steel tubing and connections including cleaning for refixing or removal to store of size 25 mm dia complete all as specified and directed. |
| 16 | Taking upor down steel tubing and connections including cleaning for refixing or removal to store of size 20 mm dia complete all as specified and directed. |
| 17 | Supply & Laying in trenches galvanised steel water tubing ofmedium grade with all fittings such as bends, elbows, tees, unions, nipples, short pieces etc as required at site of size 50 mm dia complete all as specified and directed.Note :- (i) Excavation and earth work shall be measured and paid seperately under relevant item of Sch A (ii) The rates quoted inclusive of cutting, jointing and testing of the pipe. |
| 18 | Supply & Fixing galvanised steel water tubing of medium grade with all fittings such as bends, elbows, tees, unions, nipples, short pieces etc and fixed complete to walls and ceilings or laid in floors all as directed of size 25 mm dia complete all as specified and directed.Note:- (i) The rates quoted inclusive of cutting, jointing and testing of the pipe. |
| 19 | Same all as per item No. 18 above but of size 20 mm dia. |
| 20 | S&F gun metal gate valves with iron wheel head screwed at both ends for iron pipes complete including dismantling of old unserviceable gate valve fixed at any location of Size 50 mm dia complete all as specified and directed. |
| 21 | Same all as per item No. 20 above but of size 25 mm dia. |
| 22 | Same all as per item No. 20 above but of size 20 mm dia. |