Tender For Onsite Checking And Testing Of 132Kv Current Transformer With All Applicable/ Routine Tests As Per Standards With Test Reports & Any Detected Fault Report

Issued by Government Departments · Jalgaon, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
22 Jan 2024
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Offline

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jalgaon → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for onsite checking and testing of 132kv current transformer with all applicable/ routine tests as per standards with test reports & any detected fault report onsite checking and testing of 132kv potential transformer with all applicable/routine tests as per standards with test reports & any detected fault report. onsite checking and testing of 132kv lightening arrestors with all applicable/routine tests as per standards with test reports & any detected fault report. onsite checking and testing of 132kv sf6 circuit breaker with all applicable/routine tests as per standards with test reports & any detected fault report. onsite checking and testing of 33kv current transformer with all applicable/ routine tests as per standards with test reports & any detected fault report. onsite checking and testing of 33kv potential transformer with all applicable/routine tests as per standards with test reports & any detected fault report. onsite checking and testing of 33kv sf6/vacuum circuit breaker with all applicable/ routine tests as per standards with test reports & any detected fault report. onsite checking and testing of 33kv lightening arrestors with all applicable/ routine tests as per standards with test reports & any detected fault report onsite checking & testing of 33kv power transformer (of any ratings) with all applicable/ routine tests of transformer, oltc mechanism & rtcc panel operation including checking of all connections, safety equipments, oil level, oil bdv test etc of the transformer with maintaining all power & control connections complete as per standards with test reports & any detected fault report. onsite checking & testing of 132kv main & auxillary/ transler bus with all applicable/ routine tests including checking of insulators, connectors, conductor complete for the applicable tests required as per standards with test reports & any detected fault report onsite checking, & testing of scada system panels(any make) with all applicable/ routine tests of system installed for switchyard including checking of all control connections, perform operation of protection & control features of system with all operations tobe carried out from the scada system panels by maintaining remote & local activities of switchyard equipments including checking & testing of all indications, annuciators & monitoring from control room complete as per standards with test reports & any detected fault report. onsite checking and testing of plcc system/panels including ups with all applicable/ routine tests for all connected equipments/accessories with necesary test & trials as per msetcl standard complete with test reports & any detected fault report. onsite checking, & testing of various panels (any make) with all applicable/ routine tests of incommer panel, feeder panel, c & r panel, bus protection panel, bus coupler panels etc panels required for the 132 kv or 33kv substations with checking of all control connections, perform operation of protection & control features of system with all operations tobe carried out from the scada system (if available) panels by maintaining remote & local activities of switchyard equipments checking & testing of all indications, annuciators & monitoring from control room complete as per standards with test reports & any detected fault report. onsite gas filling for 132 kv or 33kv sf6 circuit breaker with required pressure as per is supply & erection of electrostatic energy (ese) lightning arrester, early streamer emission air terminal (eseat) with following specifications: eseat protection radius 107 mtr. with suitable mast height, with triggering time of 60 micro second as per nfc 17-102: 2011 which release the ascending discharge excitation in good time of stored electrostatic energy which is present in atmosphere. the eseat air-terminal shall be tested as per nfc 17-102:2011 (annexure c) to support a 100ka current (waveform 10/350 µs). test to be performed in compliance with nfc 17 102 version 2011. the eseat should be able to work in both (positive and negative) lightning polarities. the eseat should be testing in the eseat shall be in strict compliance with the new test guidelines as per annex c of the revised nfc 17 102 version 2011 for ese lightning protection system. the eseat shall be made of stainless steel 304l grade non- corrosive metallic components, electronic circuit, triggering device etc generate the streamer. the following test should be conducted for eseat in high voltage laboratory as per nfc 17-102: 2011 annex c clause c a. general test: visual inspection, identification and marking b. mechanical test: for inspecting dimensional characteristic c. environmental test: salt mist test humid sulphurous atmosphere treatment e. early streamer emission test: compared the relative break-down time of eseat with srat the eseat should be type tested by cpri for impulse current of 70 ka (8/20 µs) for one of the samples. the eseat to be a fully autonomous system requiring no external power supply. the eseat shall be testable on site. the eseat should be sustainably designed to mitigate its environmental impact the eseat to be mounted on provided base & support arrangements warranty: 5 years (60 months) from the date of commissioning with supply of minimum 6 digit electro- mechanical lightning discharge counter mounted on down conductor having following features: a. range of intensity: 1 ka (8/20 ps) 100 ka (10/50 ps) b. working temp of -20°c to +60°c c. protection class: ip 65 d. easy to monitor and install and no maintenance required. e. standards applicable: iec 62561 lightning protection system components (lpsc) - part 6: requirements for lightning strike counters (lsc) lightning strike counter to be mounted at a height of about 2mtr from ground level with provided pole clamp this item proposed to installed as per the technical specifications; along with 3 nos of fast electrode mode fe-88, 1 mtr long gl earthing with 25 kgs earth enhancing compound; 5 mtr gi mounting pole with base plate, 7 mtr of 70 sq.mm cooper flexible cable, 35 kgs gl strip and accessories.

AI Tender Summary

OUR REF NO 41706685
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 22-01-2024
Authority
Authority Name Irrigation Department
Work Description Tender for onsite checking and testing of 132kv current transformer with all applicable/ routine tests as per standards with test reports & any detected fault report onsite checking and testing of 132kv potential transformer with all applicable/routine tests as per standards with test reports & any detected fault report. onsite checking and testing of 132kv lightening arrestors with all applicable/routine tests as per standards with test reports & any detected fault report. onsite checking and testing of 132kv sf6 circuit breaker with all applicable/routine tests as per standards with test reports & any detected fault report. onsite checking and testing of 33kv current transformer with all applicable/ routine tests as per standards with test reports & any detected fault report. onsite checking and testing of 33kv potential transformer with all applicable/routine tests as per standards with test reports & any detected fault report. onsite checking and testing of 33kv sf6/vacuum circuit breaker with all applicable/ routine tests as per standards with test reports & any detected fault report. onsite checking and testing of 33kv lightening arrestors with all applicable/ routine tests as per standards with test reports & any detected fault report onsite checking & testing of 33kv power transformer (of any ratings) with all applicable/ routine tests of transformer, oltc mechanism & rtcc panel operation including checking of all connections, safety equipments, oil level, oil bdv test etc of the transformer with maintaining all power & control connections complete as per standards with test reports & any detected fault report. onsite checking & testing of 132kv main & auxillary/ transler bus with all applicable/ routine tests including checking of insulators, connectors, conductor complete for the applicable tests required as per standards with test reports & any detected fault report onsite checking, & testing of scada system panels(any make) with all applicable/ routine tests of system installed for switchyard including checking of all control connections, perform operation of protection & control features of system with all operations tobe carried out from the scada system panels by maintaining remote & local activities of switchyard equipments including checking & testing of all indications, annuciators & monitoring from control room complete as per standards with test reports & any detected fault report. onsite checking and testing of plcc system/panels including ups with all applicable/ routine tests for all connected equipments/accessories with necesary test & trials as per msetcl standard complete with test reports & any detected fault report. onsite checking, & testing of various panels (any make) with all applicable/ routine tests of incommer panel, feeder panel, c & r panel, bus protection panel, bus coupler panels etc panels required for the 132 kv or 33kv substations with checking of all control connections, perform operation of protection & control features of system with all operations tobe carried out from the scada system (if available) panels by maintaining remote & local activities of switchyard equipments checking & testing of all indications, annuciators & monitoring from control room complete as per standards with test reports & any detected fault report. onsite gas filling for 132 kv or 33kv sf6 circuit breaker with required pressure as per is supply & erection of electrostatic energy (ese) lightning arrester, early streamer emission air terminal (eseat) with following specifications: eseat protection radius 107 mtr. with suitable mast height, with triggering time of 60 micro second as per nfc 17-102: 2011 which release the ascending discharge excitation in good time of stored electrostatic energy which is present in atmosphere. the eseat air-terminal shall be tested as per nfc 17-102:2011 (annexure c) to support a 100ka current (waveform 10/350 µs). test to be performed in compliance with nfc 17 102 version 2011. the eseat should be able to work in both (positive and negative) lightning polarities. the eseat should be testing in the eseat shall be in strict compliance with the new test guidelines as per annex c of the revised nfc 17 102 version 2011 for ese lightning protection system. the eseat shall be made of stainless steel 304l grade non- corrosive metallic components, electronic circuit, triggering device etc generate the streamer. the following test should be conducted for eseat in high voltage laboratory as per nfc 17-102: 2011 annex c clause c a. general test: visual inspection, identification and marking b. mechanical test: for inspecting dimensional characteristic c. environmental test: salt mist test humid sulphurous atmosphere treatment e. early streamer emission test: compared the relative break-down time of eseat with srat the eseat should be type tested by cpri for impulse current of 70 ka (8/20 µs) for one of the samples. the eseat to be a fully autonomous system requiring no external power supply. the eseat shall be testable on site. the eseat should be sustainably designed to mitigate its environmental impact the eseat to be mounted on provided base & support arrangements warranty: 5 years (60 months) from the date of commissioning with supply of minimum 6 digit electro- mechanical lightning discharge counter mounted on down conductor having following features: a. range of intensity: 1 ka (8/20 ps) 100 ka (10/50 ps) b. working temp of -20°c to +60°c c. protection class: ip 65 d. easy to monitor and install and no maintenance required. e. standards applicable: iec 62561 lightning protection system components (lpsc) - part 6: requirements for lightning strike counters (lsc) lightning strike counter to be mounted at a height of about 2mtr from ground level with provided pole clamp this item proposed to installed as per the technical specifications; along with 3 nos of fast electrode mode fe-88, 1 mtr long gl earthing with 25 kgs earth enhancing compound; 5 mtr gi mounting pole with base plate, 7 mtr of 70 sq.mm cooper flexible cable, 35 kgs gl strip and accessories.
Basic Detail
Tender No 32
Bidding Type Tender
Location
City Jalgaon
State Maharashtra
Key Dates
Publish Date 17 Jan 2024
Submission Date 22 Jan 2024
Open Date 22 Jan 2024
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
cfba53b2-2627-4228-b262-3471b9e6eed7.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 17, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 22, 2024
17:00 IST

Bid Submission Deadline

Offline submission at the designated office.

Completed
Jan 22, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

cfba53b2-2627-4228-b262-3471b9e6eed7.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender