Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Creation Of 2X250 Kva Sub Station Alongwith Erection Of 11 Kv Line On 9 Mtr. Longst Poles, 30Mm Sqacsrweasel Conductor & Lt Line On 8 Mtr. St Poleat Wss Jandrari Under Jjm On Turnkey Basis- 1 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 11 Kv Line On 9 Mtr. Long St Poles, 30Mm² Acsr Conductor At Wssjandraristage Zero. 2 9 Mtr. Long St Pole ( St-410 Sp-33 ) 3 Gi V Cross -Arm With Top Bracket Including Clamps 4 Gi Channel X-Arm Including Clamps And Angle For Braces 5 30Mm² Acsr Weasel Conductor 6 11 Kv Go Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical 7 11 Kv Polymer Composite Pin Insulator 12 Kv, 5 Kn, Lighting Impulse 75 Kv Positive And 80 Kv Negative, Creepage Distance 320Mm. 8 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45 Kn, Lightening Impulse 75Kvpositive And 80 Kv Negative, Creepage Distance 320Mm With Fitting 9 Galvanized Nuts And Bolts 10 Danger Plates With Clamps 11 Anti Climbing Device With Clamps 12 Earthing Complete Bygi Rod 20 Mm, 2.5 Mtr Long Through G.I. Strip 25X3 Mm 13 Painting Of 9 Mtr St Poles With Two Coats Of Aluminiumpaint. 14 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 15 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 16 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Creation Of 250 Kva Sub Stn. At Wss Jandraristage Zero. 17 11 / 0.433 Kv, 3-Phase Distribution Transformer 250 Kva With Bimetallic Terminal Connectors Energy Level-2 Copperwound, & With Lv Cable Box Having Detachable Aluminium Gland Plate 18 Gapless Surge Arrestor, 9 Kv, 10 Ka , La With Polymer Housing Stn. Type 19 11 Kv Go Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical 20 11 Kv Horn Gap Fuse Set 3 Phase 200 A 21 300Mm² 1.1 Kv Grade, Pvc Insulated Stranded Conductor Frls Type 22 9 Mtr. Long St Pole ( St-410 Sp33 ) 23 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45 Kn, Lightening Impulse 75Positive And 80 Kv Negative, Creepage Distance 320Mm With Fitting 24 Gi Channel / Angle / Flat Of Sizes Including Clamps 25 Galvanized Nuts And Bolts. 26 Earthing Of Sub Stn. Excavation Of Earth Pit Of Dia 650Mm & Depth 3000Mm Installation Of Earthing Pipe Of 40Mm Nominal Bore & 4Mm Wall Thickness & Length 2.5 Mtr. Long As Per Is 1239. G.I Strip For Neutral Earthing Of Size 25Mmx3mmfor Connection Of Transforemr Body, Go Set & Lightening Arrestor As Per Is 2629 / 85, Gi Nuts & Bolts Refilled With Earth Enhancement Materials And Earth Chamber With Rcc Slab Cover 27 11 Kv Polymer Composite Pin Insualtor, 12 Kv, 5Kn Lightening Impulse 75 Kv Positve And 80 Kv Negative, Creepage Distance 320Mm 28 Lt Distribution Box For 250 Kva Dtr With Mccb For Incormer And SfuS For Outgoing Circuits Box For 29 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 30 Pg Clamps 31 Danger Plates With Clamps 32 Gi Barbed Wire For Anticlimbing 33 3-Phase Ht Trivector Meter With Ct Pt Unit 34 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 35 Painting Of St Poles 9 Mtr. Long With 2 Coat Of Al. Paint 36 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 3 Phase 4 Wire Lt Line On 8 Mtr. St Poles At Wssjandraristage Zero. 37 8 Mtr. Long St Poles ( St-410 Sp15 ) 38 Gi M Clamps For Shackle Insulator 39 50Mm²acsr Rabbit Conductor 40 Shackle Insulator 41 Galvanized Nuts And Bolts. 42 Danger Plates With Clamps 43 Anti Climbing Device With Clamps 44 Earthing Complete Bygi Rod 20Mm 2.5 Mtr. Long Through Gi Strip 45 Painting Of 8 Mtr St Poles With Two Coat Of Aluminium Paint 46 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 47 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 48 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 11 Kv Line On 9 Mtr. Long St Poles, 30Mm² Acsr Conductor At Wss Jandraristage First. 49 9 Mtr. Long St Pole ( St-410 Sp-33 ) 50 Gi V Cross -Arm With Top Bracket Including Clamps 51 Gi Channel X-Arm Including Clamps And Angle For Braces 52 30Mm² Acsr Weasel Conductor 53 11 Kv Go Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical 54 Pg Clamps 55 11 Kv Polymer Composite Pin Insulator 12 Kv, 5 Kn, Lighting Impulse 75 Kv Positive And 80 Kv Negative, Creepage Distance 320Mm. 56 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45 Kn, Lightening Impulse 75Kvpositive And 80 Kv Negative, Creepage Distance 320Mm With Fitting 57 Galvanized Nuts And Bolts 58 Danger Plates With Clamps 59 Anti Climbing Device With Clamps 60 Earthing Complete Bygi Rod 20 Mm, 2.5 Mtr Long Through G.I. Strip 25X3 Mm 61 Painting Of 9 Mtr St Poles With Two Coats Of Aluminiumpaint. 62 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 63 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 64 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Creation Of 250 Kva Sub Stn. At Wss Jandrari Stage First. 65 11 / 0.433 Kv, 3-Phase Distribution Transformer 250 Kva With Bimetallic Terminal Connectors Energy Level-2 Copperwound, & With Lv Cable Box Having Detachable Aluminium Gland Plate 66 Gapless Surge Arrestor, 9 Kv, 10 Ka , La With Polymer Housing Stn. Type 67 11 Kv Go Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical 68 11 Kv Horn Gap Fuse Set 3 Phase 200 A 69 300Mm² 1.1 Kv Grade, Pvc Insulated Stranded Conductor Frls Type 70 9 Mtr. Long St Pole ( St-410 Sp33 ) 71 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45 Kn, Lightening Impulse 75Positive And 80 Kv Negative, Creepage Distance 320Mm With Fitting 72 Gi Channel / Angle / Flat Of Sizes Including Clamps 73 Galvanized Nuts And Bolts. 74 Earthing Of Sub Stn. Excavation Of Earth Pit Of Dia 650Mm & Depth 3000Mm Installation Of Earthing Pipe Of 40Mm Nominal Bore & 4Mm Wall Thickness & Length 2.5 Mtr. Long As Per Is 1239. G.I Strip For Neutral Earthing Of Size 25Mmx3mmfor Connection Of Transforemr Body, Go Set & Lightening Arrestor As Per Is 2629 / 85, Gi Nuts & Bolts Refilled With Earth Enhancement Materials And Earth Chamber With Rcc Slab Cover 75 11 Kv Polymer Composite Pin Insualtor, 12 Kv, 5Kn Lightening Impulse 75 Kv Positve And 80 Kv Negative, Creepage Distance 320Mm 76 Lt Distribution Box For 250 Kva Dtr With Mccb For Incormer And SfuS For Outgoing Circuits Box For 77 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 78 Pg Clamps 79 Danger Plates With Clamps 80 Gi Barbed Wire For Anticlimbing 81 3-Phase Ht Trivector Meter With Ct Pt Unit 82 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 83 Painting Of St Poles 9 Mtr. Long With 2 Coat Of Al. Paint 84 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 3 Phase 4 Wire Lt Line On 8 Mtr. St Poles At Wss Jandraristage First. 85 8 Mtr. Long St Poles ( St-410 Sp15 ) 86 Gi M Clamps For Shackle Insulator 87 50Mm²acsr Rabbit Conductor 88 Shackle Insulator 89 Galvanized Nuts And Bolts. 90 Danger Plates With Clamps 91 Anti Climbing Device With Clamps 92 Earthing Complete Bygi Rod 20Mm 2.5 Mtr. Long Through Gi Strip 93 Painting Of 8 Mtr St Poles With Two Coat Of Aluminium Paint 94 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 95 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete