}

Annual Plan-S0178 / 24-Malinnyamuktha Navakeralam-Electrification Work For Installation Of Purchased Equipments To Mcf Karalam Gp-Electrification Work For Installation Of Purchased Equipments To Mcf Karalam Gp-General Electrical Work, Thrissur-Kerala

Grama Panchayat has published Annual Plan-S0178 / 24-Malinnyamuktha Navakeralam-Electrification Work For Installation Of Purchased Equipments To Mcf Karalam Gp-Electrification Work For Installation Of Purchased Equipments To Mcf Karalam Gp-General Electrical Work. Submission Date for this Tender is 22-01-2024. Electrical Maintenance Tenders in Thrissur Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

41592726
Annual Plan-S0178 / 24-Malinnyamuktha Navakeralam-Electrification Work For Installation Of Purchased Equipments To Mcf Karalam Gp-Electrification Work For Installation Of Purchased Equipments To Mcf Karalam Gp-General Electrical Work
Tender
Indian
Kerala
Thrissur
22-01-2024

Tender Details

Annual Plan-S0178 / 24-Malinnyamuktha Navakeralam-Electrification Work For Installation Of Purchased Equipments To Mcf Karalam Gp-Electrification Work For Installation Of Purchased Equipments To Mcf Karalam Gp-General Electrical Work-2 90.2.2.1:Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providingswitch Boardmain And Continuous Earthing With No.14 Swg Bare Copper, Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping / Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates ( White ) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And DbS Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. ( Group B / Rohs Compliant Modular Accessories ) .Single Control Light Point With 6A, Plate Ceiling Rose - Short Point 3 90.2.2.6:Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providingswitch Boardmain And Continuous Earthing With No.14 Swg Bare Copper, Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping / Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates ( White ) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And DbS Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. ( Group B / Rohs Compliant Modular Accessories ) .Combined Plug Point With 6 A, 5 Pin Plug Socket Controlled By 6 A Switch In The Same Switch Board As That Of Light Points. 4 90.15.4.2:Supply Conveyance, Installation, Testing And Commissioning Of 36 / 40W Led Street Light Output Greater Than 105Lumen / W 4000-6000 K With Ip 66 Protection Led Chip Make Cree / Lumilled / Nichea With Power Factor Greater Than 0.95 At Full Load, Internal Surge Protection Up To 8 Kv, And Aluminium Pressure Die-Cast Powder Coated Housing, Acrylic Cover Complete With Thd Less Than 10%, Power Factor Greater Than 0.98, Rohs Compliant, Duly Wired Up For Use On 230 V Ac Supply. Driver Compartment Should Be Seperatly Accessible For Maintenance ( Lm 79&80 Certificates From Nabl Accredited Third Party Lab To Be Produced Mentioning Chip Manufacturer ) 5 90.15.4.3:Supply Conveyance, Installation, Testing And Commissioning Of 70W Led Street Light Output Greater Than 105Lumen / W 4000-6000 K With Ip 66 Protection Led Chip Make Cree / Lumilled / Nichea With Power Factor Greater Than 0.95 At Full Load, Internal Surge Protection Up To 8 Kv, And Aluminium Pressure Die-Cast Powder Coated Housing, Acrylic Cover Complete With Thd Less Than 10%, Power Factor Greater Than 0.98, Rohs Compliant, Duly Wired Up For Use On 230 V Ac Supply. Driver Compartment Should Be Seperatly Accessible For Maintenance ( Lm 79&80 Certificates From Nabl Accredited Third Party Lab To Be Produced Mentioning Chip Manufacturer ) 6 90.3.17.1:Supply, Conveyance And Erection Ofthe Following Sizes Of B Class Gi Pipe In Single Section For Post Top Lantern Of All Types On Concrete Base ( Excluding Charges For Concrete Base And Excavation ) And Painting With 2 Coats Of Synthetic Enamel Paint Over A Coat Of Zinc Chromate Primer Etc. As Required.32 Mm Dia Gi Pipe 7 90.15.4.5:Supply Conveyance, Installation, Testing And Commissioning Of 40W Led Flood Light Output Greater Than 105Lumen / W 4000-6000 K With Ip 66 Protection Led Chip Make Cree / Lumilled / Nichea With Power Factor Greater Than 0.95 At Full Load, Internal Surge Protection Up To 8 Kv, And Aluminium Pressure Die-Cast Powder Coated Housing, Acrylic Cover Complete With Thd Less Than10%, Power Factor Greater Than 0.98, Rohs Compliant, Duly Wired Up For Use On 230 V Ac Supply. Driver Compartment Should Be Seperatly Accessible For Maintenance ( Lm 79&80 Certificates From Nabl Accredited Third Party Lab To Be Produced Mentioning Chip Manufacturer ) 8 90.4.1:Supply And Installation Of Suitable Size Ms Rod Type Fan Clamp In The Rcc Slab As Per Is 732 As Required. 9 90.4.5.4:Supply, Installation, Testing And Commissioning Of Ceiling Fan Of Following Sizes Including Wiring The Down Rods Of Standard Length ( Up To 30 Cm ) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required.1200Mm Sweep - Ceiling Fan Complete With Service Value Minimum 4.0 ( Cub Meter / Minute / Watt ) , Air Delivery Minimum 210 ( Cubic Meter / Minute ) , Copper Winding Suitable For 230V / 240V Single Phase Ac Supply 10 1.47:Supplying And Fixing Extra Down Rod Of 10 Cm Length G.I. Pipe, 15 Mm Dia, Heavy Gauge Including Painting Etc. As Required. ( Note: More Than 5 Cm Length Shall Be Rounded To The Nearest 10 Cm And 5 Cm Or Less Shall Be Ignored ) 11 1.27.2:Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.3 Module ( 100Mmx75mm ) 12 1.24.1:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5 / 6 Amps Switch 13 1.24.3:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15 / 16 Amp Switch 14 1.27.5:Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.8 Module ( 125Mmx125mm ) 15 1.27.6:Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.12 Module ( 200Mmx150mm ) 16 1.24.4:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5 / 6 Amp Socket Outlet 17 1.24.5:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15 / 16 Amp Socket Outlet 18 1.25:Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 19 1.26:Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. 20 1.33:Supplying And Fixing 3 Pin, 5 Amp Ceiling Rose On The Existing Junction Box / Wooden Block Including Connection Etc As Required. 21 90.6.10.1:Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required20 Mm 22 90.6.10.2:Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required25 Mm 23 90.6.10.3:Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required32 Mm 24 1.17.2:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.2 X 1.5 Sq. Mm 25 1.17.3:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.3 X 1.5 Sq.Mm 26 1.17.5:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.5 X 1.5 Sq. Mm 27 1.17.7:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.7 X 1.5 Sq. Mm 28 1.17.4:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.4 X 1.5 Sq. Mm 29 1.17.6:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.6 X 1.5 Sq. Mm 30 1.17.11:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.2 X 2.5 Sq. Mm 31 1.17.13:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.4 X 2.5 Sq. Mm 32 1.17.20:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.2 X 4 Sq. Mm 33 1.17.22:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.4 X 4 Sq. Mm 34 1.17.31:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.4 X 6 Sq. Mm 35 2.10.1:Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 36 2.10.5:Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Triple Pole And Neutral 37 90.11.1.10:Supply And Installation Ofsheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages, Colour Washing Etc. As Required4 Way ( 8+12 ) - Three Phase Double Cover ( Ip 42 / 43 ) 38 2.12.1:Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 39 2.11:Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 40 2.13.1:Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 41 2.15.2:Supplying And Fixing Following Rating, Four Pole, ( Three Phase And Neutral ) , 415 Volts, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 42 Od313766 / 2023-2024:Supply And Providing Motor Controller Suitable For Three Phase 10 Hp Motor Including Providing Ameter / Voltmeter , Spp Etc And Giving Connection Etc As Required . ( L&T Mu G15 ( 9-14 ) / Equivlentmake ) 43 Od313872 / 2023-2024:Supply And Providing Motor Controller Suitable For Threephase 3 / 5 Hp Motor Including Providing Ameter / Voltmeter , Spp Etc And Giving Connection Etc As Required . ( L&T Mu G10 Dol ) / Equivlentmake ) 44 90.14.24.2:Supply & Fixingthe Following Power Capacitors 3 Phase Delta Connected In Positon And Giving Connection.2 Kvar, 3 Phase, 440 V, Delta Connected Standard Duty Metalised Poly Propylene Capacitor, Cylinderical Type, Suitable For Direct Connection To Motors. 45 90.14.24.4:Supply & Fixingthe Following Power Capacitors 3 Phase Delta Connected In Positon And Giving Connection.4 Kvar, 3 Phase, 440 V, Delta Connected Standard Duty Metalised Poly Propylene Cylinderical Capacitor Suitable For Direct Connection To Motors. 46 Od313767 / 2023-2024:Supply And Providing 4 Pole Sheet Steel Enclosure On Surface / Recess And Making Good The Damages , Colour Washing Etc As Required . 47 5.4:Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. 48 90.16.3.3:Supply And Clamping The Following Size Of Strips On Surface Of Wall / Parapet / Existing Cable Tray Using Clamps Fabricated From 20 X 3 Mm Gi Flat Duly Painted Or Heavy Duty Gi Spacer Saddles Spacing Of Clamps Not Exceeding 1 M, Making Good The Damages, Colour Washing Etc. As Required ( For Horizontal Run ) 25 X 6 Mm Gi Strip 49 90.16.1.1:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required2.00 Mm Copper Conductor ( 14 Swg ) 50 90.16.1.2:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required2.65 Mm Copper Conductor ( 12 Swg ) 51 90.16.1.3:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg ) 52 90.16.1.4:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required4.00 Mm Copper Conductor ( 8 Swg ) 53 90.16.5.1:Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.2.00 Mm ( 14 Swg ) 54 90.12.7.39:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.4 Core 6 Sq Mm With Factory Made Clamp 55 9.1.32:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.4 X 10 Sq. Mm ( 25Mm ) 56 90.16.5.3:Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.3.15 Mm ( 10 Swg ) 57 90.16.5.2:Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.2.65 Mm ( 12 Swg ) 58 90.16.5.4:Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.4.00 Mm ( 8 Swg ) 59 Od313467 / 2023-2024:Supply And Providing Thefollowingsizesof Bolt And Nut With Washers Onthe Existingm.S Box / Earth Bus Etc. As Requiredincluding Drillingnecessary Holes As Required. 25X6mm Brass Nut And Bolt . 60 Od313468 / 2023-2024:Supply And Providing Thefollowingsizesof Bolt And Nut With Washers Onthe Existingm.S Box / Earth Bus Etc. As Requiredincluding Drillingnecessary Holes As Required. 12X3mm Brass Nut And Bolt . 61 90.16.2.1:Supply And Laying Of The Following Sizes Of B Class Gipipe Laid 0.6 M Below Ground Level Including Excavating Trench Of Suitable Size And Refilling Etc, As Required.15.Mm Dia. G.I Pipe ( Medium Class ) 62 Od313469 / 2023-2024:Supply And Providing Ms Eye Bolt Hook In Wall / Parapet For Binding Support For Ksebservice Wire Connection 63 90.14.5:Supply And Fabrication Conveyance And Installation Of Angle Iron Frame Work For Wall Mounting Panel Board 64 Od313470 / 2023-2024:Supply And Installation Of Abc Type Fire Extinguisherof 5 Kgs.Is 4308. Capacity With Initial Filling In Brand New Cylinder With Powder Coated Finish, Discharge Hose, Wall Mounting Bracket Etc. Complete. The Extinguisher Is Manufactured Strictly As Per Is: 15683:2018. 65 Od313471 / 2023-2024:Supply And Providing 2.00 Mm Thick 3.3 Kv Synthetic Electromeric Fire Retardant Insulating Sheet 66 Od313472 / 2023-2024:Supply And Providing 9 Litre Capaacity Gi Fire Bucket Painted In Post Office Red With Primer Coat Of Red Oxide And Written With White Paint Fire Mounted Ob Ms Angle Frame Work / Wall Bracket Filled With Fine Sand, Painting The Bracket / Floor Stand Including Making Good The Damages, Colour Washing Etc As Required 67 Od313474 / 2023-2024:Preparing Completion And Test Certificates For Kseb Connection 68 Od313475 / 2023-2024:Supply And Fixing The Following Accessories In The Existing Board And Giving Connections Etc.63A 2 Way Neutral Link Mounted On Dmc / Smc Base 69 Od313476 / 2023-2024:Supply And Fixing The Following Accessories In The Existing Board And Giving Connections Etc.63A Hrc Fuse Base With Hrc Fuse Link 70 Od313478 / 2023-2024:Supply And Providing Earth Clamps For Siemens / Tropodor Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands As Required. 4 Sqmm To 16 Sqmm With 12Mm Widex1 Mm Thick Clip.

Key Value

Document Fees
INR 555 /-
EMD
INR 4942.0 /-
Tender Value
INR 1.97 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail