Supply , Commissioning Control Device , Design Supply Erection And Commissioning Of Retrofit Emission Control Device On 750 Kva & 1010 Kva Make- Cummins ( Note:- Terms & Condition As Per Panipat Sugar Mills. ) , Design, Supply, Erection, Commissioning Of Retrofit Emission Control Devices ( Recd ) For 750 Kva 1 No Cummins Diesel Engine Powered D.G Sets Including All Civil Work, Pipe Lines, Structure Etc As Per Site Requirement Along With One Year Amc. ( Work Will Be Completed In All Respect As Per Guild Lines Of Cpcb , Spcb & Commission For Air Quality Management, New Delhi ) Including One Year Amc Make- Cummins D.G Set 750 Kva 01 No Details: - Engine Sr.No- 25453500 Engine Model No.- Kta-38 –G12. 1068 Hp@1500 Rpm The Device Should Be Design, Erected And Commissioned In Such A Way That It Should Not Adversely Affect The Rated Capacity And Normal Working Of Existing D.G Sets. The Device Should Achieve The Air Emission Standard Notified By Commission Of Air Quality Management Mentioned Below. Technology:-Recd Voltage Base Carbon Cutting Technology. Note:- Emission Control Device Should Achieve The Norms Specified By Commission For Air Quality Management Vide Their Notification No. F.No. A-110018 / 01 / 2021-Caqm / 827 ( Dt ) Dated 02-06-2023 And F.No. A-11018 / 01 / 2021-Caqm / 5322-15331 Dated 29.09.2023. Sr.No.Parameters Emission Standard 1.Pm ( At 15% O2 ) 50Mg / Nm3 2. Nox ( At 15% O2 ) 650 Mg / Nm3 3. Co ( At 15% O2 ) 100 Mg / Nm3 Note:-System Should Be Connected With Existing 30 Mtr. Height Stack. Guarantee Period Should Be One Year Regarding Performance Of The Device And Dg Set In All Manner I.E. Load, Fuel Consumption Etc. , Design, Supply, Erection, Commissioning Of Retrofit Emission Control Devices ( Recd ) For 1010 Kva -01 No Cummins Diesel Engine Powered D.G Sets Including All Civil Work, Pipe Lines, Structure Etc As Per Site Requirement Along With One Year Amc. ( Work Will Be Completed In All Respect As Per Guild Lines Of Cpcb , Spcb & Commission For Air Quality Management, New Delhi ) Including One Year Amc Make- Cummins D.G Set1010 Kva 01No. Details: - Engine Sr.No- 25452748 Engine Model No.-Kta-38-G5 1180 Hp@ 1500 Rpm. The Device Should Be Design, Erected And Commissioned In Such A Way That It Should Not Adversely Affect The Rated Capacity And Normal Working Of Existing D.G Sets. The Device Should Achieve The Air Emission Standard Notified By Commission Of Air Quality Management Mentioned Below. Technology:-Recd Voltage Base Carbon Cutting Technology. Note:- Emission Control Device Should Achieve The Norms Specified By Commission For Air Quality Management Vide Their Notification No. F.No. A-110018 / 01 / 2021-Caqm / 827 ( Dt ) Dated 02-06-2023 And F.No. A-11018 / 01 / 2021-Caqm / 5322-15331 Dated 29.09.2023. Sr.No. Parametersemission Standard 1. Pm ( At 15% O2 ) 50Mg / Nm3 2.Nox ( At 15% O2 ) 650 Mg / Nm3 3.Co ( At 15% O2 ) 100 Mg / Nm3 Note:-System Should Be Connected With Existing 30 Mtr. Height Stack. Guarantee Period Should Be One Year Regarding Performance Of The Device And Dg Set In All Manner I.E. Load, Fuel Consumption Etc. , Design, Supply, Erection, Commissioning Of Retrofit Emission Control Devices ( Recd ) ( Technology Based:- Diesel Oxidation Catalyst + Diesel Particulate Filter Base Technology ) For 750 Kva 01 No Cummins Diesel Engine Powered D.G Sets Including All Civil Work, Pipe Lines, Structure With Paint Etc As Per Site Requirement Along With One Year Amc. ( Work Will Be Completed In All Respect As Per Guild Lines Of Cpcb , Spcb & Commission For Air Quality Management, New Delhi ) Make- Cummins Make D.G Set 750 Kva -01No Details:- Engine Sr.No- 25453500 Engine Model No.- Kta-38 –G12. 1068 Hp@1500 Rpm & The Device Should Be Design, Erected And Commissioned In Such A Way That It Should Not Adversely Affect The Rated Capacity And Normal Working Of Existing D.G Sets. The Device Should Achieve The Air Emission Standard Notified By Commission Of Air Quality Management Mentioned Below. Technology:- Diesel Oxidation Catalyst + Diesel Particulate Filter Base Technology Note:- Emission Control Device Should Achieve The Norms Specified By Commission For Air Quality Management Vide Their Notification No. F.No. A-110018 / 01 / 2021-Caqm / 827 ( Dt ) Dated 02-06-2023 And F.No. A-11018 / 01 / 2021-Caqm / 5322-15331 Dated 29.09.2023. Sr.No.Parameters Emission Standard 1. Pm ( At 15% O2 ) 50Mg / Nm3 2. Nox ( At 15% O2 ) 650 Mg / Nm3 3.Co ( At 15% O2 ) 100 Mg / Nm3 Note:-System Should Be Connected With Existing 30 Mtr. Height Stack. Guarantee Period Should Be One Year Regarding Performance Of The Device And Dg Set In All Manner I.E. Load, Fuel Consumption Etc. , Design, Supply, Erection, Commissioning Of Retrofit Emission Control Devices ( Recd ) ( Technology Based:- Diesel Oxidation Catalyst + Diesel Particulate Filter Base Technology ) For 1010 Kva 01 No Cummins Diesel Engine Powered D.G Sets Including All Civil Work, Pipe Lines, Structure With Paint Etc As Per Site Requirement Along With One Year Amc. ( Work Will Be Completed In All Respect As Per Guild Lines Of Cpcb , Spcb & Commission For Air Quality Management, New Delhi ) Make- Cummins Make D.G Set1010 Kva- One Nos. Details:- Engine Sr.No-25452748 Engine Model No.-Kta-38-G5 1180 Hp@ 1500 Rpm. The Device Should Be Design, Erected And Commissioned In Such A Way That It Should Not Adversely Affect The Rated Capacity And Normal Working Of Existing D.G Sets. The Device Should Achieve The Air Emission Standard Notified By Commission Of Air Quality Management Mentioned Below. Technology:- Diesel Oxidation Catalyst + Diesel Particulate Filter Base Technology Note:- Emission Control Device Should Achieve The Norms Specified By Commission For Air Quality Management Vide Their Notification No. F.No. A-110018 / 01 / 2021-Caqm / 827 ( Dt ) Dated 02-06-2023 And F.No. A-11018 / 01 / 2021-Caqm / 5322-15331 Dated 29.09.2023. Sr.No.Parameters Emission Standard 1. Pm ( At 15% O2 ) 50Mg / Nm3 2. Nox ( At 15% O2 ) 650 Mg / Nm3 3.Co ( At 15% O2 ) 100 Mg / Nm3 Note:-System Should Be Connected With Existing 30 Mtr. Height Stack. Guarantee Period Should Be One Year Regarding Performance Of The Device And Dg Set In All Manner I.E. Load, Fuel Consumption Etc.