| 1 | Taking down carefully (copper/aluminum) point wiring complete of any type (batten/surface conduit) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants regulators etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster or tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed. |
| 2 | Material and Labour for point wiring complete using 1.5 Sqmm PVC insulated unsheathed copper conductor, stranded cable (FR) upto and including working voltage 1100volts grade, drawn through and including non metallic rigidPVC conduit or PVC casing and caping of suitable size including all accessories ISI marked including pressed steel terminal sunken boxes of size 1.2mm covered with 3mm thick plastic laminated sheet ISI marked top cover fixed with Brass screws and unsheathed copper conductor stranded cable(FR) earth continuity wire connected to DBs/sunken boxes/fittings of size 1.5 Sqmm Cross sectional area and all other metal parts with earth dolly for the following:- |
| 3 | (a ) onelight point controlled by one switch 5 Amps |
| 4 | (b ) onefan pointpoint controlled by one switch 5 Amps |
| 5 | (c) One 3pin socket outlet 5 Ampson Independent board |
| 6 | (d ) One 3pin socket outlet 5 Ampsonsame board |
| 7 | ( e) One bell pointcontrolled by one bell push |
| 8 | Supply and fix Switch piano Flush, single pole, one way 5 amp 230 Volts, AC, with ISI mark complete all as specified and directed. |
| 9 | Supply and fix Bell push, single pole, one way 5 amp 230 Volts, AC, with ISI mark complete all as specified and directed. |
| 10 | Supply and fix Socket outlet2 in 1, 5 Amps flush type 230 Volts, AC, with ISI mark complete all as specified and directed. |
| 11 | Supply and fix Bell electric Ding Dong 230 Volts, AC, with ISI mark complete all as specified and directed. |
| 12 | All as per item No.2 above but with 2.5 sqmm PVC insulated unsheathed copper conductor for 15 Amps 3 pin socket. |
| 13 | Supply and fix SwitchSocket Combination2 in 1, 5 Amps /16 Ampsflushtype230 Volts, AC, with ISI mark complete all as specified and directed. |
| 14 | Attending internal/ external electric complaint for maintenance/breakdown, round the clock for maintenance, checking, fault finding and rectification of fault in LT panels/Overhead HT/LT lines, transformers, switchgears and carry out repairs and resume electric supply complete all as specified and directed by Engineer-in-charge.Note:- (a)Day to day complaint rectified by the Electrician shall be written in complaint register and completion report recorded in complaint register and complaint document slip rectified complaints only will be paid.(b) The spares required for the rectification of fault shall be measured under items 10 to 32.(c).(c) 5 Nos complaints will be measured as one job. |
| 15 | Supply only Switch piano Flush, single pole, one way 5 amp complete all as specified and directed. |
| 16 | Supply only ofSocket outlet2 in 1, 5 Amps flush type complete all as specified and directed. |
| 17 | Supply only SwitchSocket Combination2 in 1, 5 Amps /16 AmpsflushtypeComplete all as specified and directed. |
| 18 | Supply only Bell electric ding dong 230 V complete all as specified and directed. |
| 19 | Supply only Bell push 5 Amps one way complete all as specified and directed. |
| 20 | Supply only Electronicfan regulator 230 volts, step type,2 module, 120 watt ISI Marked complete all as specified and directed. |
| 21 | Supply onlyCeiling rose in poly carbonate 3 plates flush type 6 Amps, 250 volts AC complete all as specified and directed. |
| 22 | Supply only Lamp holders bakelite body with back plate suitable for battern fitting/angle fittingcomplete all as specified and directed. |
| 23 | Supply only of Modular switch, one way, 6Amps, one module complete all as specified and directed. |
| 24 | Supply only Modular switch, one way, 16Amps one module complete all as specified and directed. |
| 25 | Supply only Modular switch, two way, 6 Amps one module complete all as specified and directed. |
| 26 | Supply only Modular socket outlet, 6 Amps, 2/3 pin twomodule complete all as specified and directed. |
| 27 | Supply only Modular socket outlet, 6 Amps/ 16 Amps, 2 and 3 pin two module complete all as specified and directed. |
| 28 | Supply only Modular Bell push, 6 Amps one module complete all as specified and directed. |
| 29 | Supply only Condenser 2.5 Mfd AC 240V, complete all as specified and directed. |
| 30 | Supply only Condenser 4 Mfd AC 240V, complete all as specified and directed. |
| 31 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.Make: Bajaj / Havells/Philips/Crompton Greaves. |
| 32 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.Make: Bajaj / Havells/Philips/Crompton Greaves. |
| 33 | Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. Make: Bajaj / Havells/Philips/Crompton Greaves. |
| 34 | Supply only LED bulb 9 watts, 230 volt complete all as specified and directed. Make: Havells/Philips/Crompton Greaves. |
| 35 | Supply only MCB double pole 240 volt B curve 10 KA 25 Amps capacity complete all as specified and directed.Make: Indoasian/ Havells / standard. |
| 36 | All as per ser item No 30 above butMCB TP415 volt C curve 10 KA, rating 16-32 Amps capacity complete all as specified and directed. Make: Indoasian/ Havells/ standard. |
| 37 | All as per ser item No 30 here-in-before but MCB single pole, 6 to 32 Amp 240 voltB curve 10 KA complete all as specified and directed. |
| 38 | Material and labour for Sub main wiring using two runs of single corePVC insulated cable(FR) 4 sqmm copper conductor multi stranded and one run of 4 sqmm copper conductor insulated cable (FR)using as earth wire drawn through and including suitable size PVC Casing and Caping including taking down old aluminium/CopperSub main wirng complete all as specified and directed. Note- 3 run of 4 sqmm PVC copper wire and One run of PVC casing capingshall be measured and paid as oneunit. |
| 39 | Material and labour for Sub main wiring using two runs of single corePVC insulated cable (FR) 6 sqmm copper conductor multi stranded and one run of 6 sqmm copper conductor insulated cable (FR)using as earth wire drawn through and including suitable size PVC Casing and Caping including taking down old aluminium/CopperSub main wirng complete all as specified and directed. Note-3 run of 6 sqmm PVC copper wire and One run of PVC casing caping shall be measured and paid as oneunit. |
| 40 | Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, TPN 4 way, single door, IP-30 protection (4 + 12 module) TPN MCB, 415 V as incomer, SP/DP/TP/TPN as outgoingcomplete all as specified and directed . |
| 41 | Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, SPN 4 way, single door, IP-30 protection DP MCB, 240 V as incomer, SP MCBs as outgoingcomplete all as specified and directed . |
| 42 | All as per ser item No 36 above but SPN 8 way, double door 240 volts |
| 43 | Supply and fix in repairs single pole andneutral enclouser with a two pin andearth plug and socketcomplete with and including one MCB single pole 20 Amps complete all as specified and directed. |
| 44 | Collectingunserviceable ceiling fan 1200/1400mm sweep 230V, AC single phase from store yard of AGE E/M and transporting to local market, cutting unserviceablewinding from fan stater & rewinding same with super enamelled copper winding wire of existing gauge size including throughly cleaning all the components, oiling greasing & replacement of rusted unserviceable screws, hanging clamps with rubber reel, canopy condensers, bush, bearing & flexible copper connection wire etc complete all as directed.Note : (i) Taking down and refixing after repair work shall be measured and paid under Item No.42 above.(ii) Spare such as Hanging clamps, canopy, condenser and flexible copper connection wire, painting, down rod, bearing, bush, clamps etc shall be measured & paid separatetly under item Nos.49 to 56. |
| 45 | All as per item No43 above but exhaust fan 300 mm sweep |
| 46 | All as per item No43 above but exhaust fan 250mm sweep |
| 47 | All as per item No 43 above butwall fan 450 mm sweep |
| 48 | Material and Labour for Scraping down old paint of ceiling fan/ Exahust fan of any size & sweep complete body & blade including down rod filling the cavitieswith filler and making smooth surfaceby applying sand paper painting the ceiling fan by meansspray gun/brush with two coats of synthetic enamel white paint complete all as specified and directed. |
| 49 | Supply only Ball bearing Ser No 6201 or 6202 complete all as specified and directed. Make : MDS/SKF/NBL |
| 50 | Supply only Ball bearing Ser No 6203/6204 complete all as specified and directed. Make : MDS/SKF/NBL or as per existing specifications as per sample |
| 51 | Supply only Gun metal bush for ceiling fan complete all as specified and directed. |
| 52 | Supply only Down rod 300mm long of size 20mm dia ISI marked complete all as specified and directed. |
| 53 | Supply and fixing in repairs oscillating mechanism suitable for wall mounting fan any make and typeall complete all as specified and as directed. |
| 54 | Supply and fixing in repair of Exhaust fan Motor of 300mm sweep heavy duty complete as per samplecomplete all as specified and as directed. |
| 55 | All as per item No 49 above but for 250mmsweep. |
| 56 | Taking down carefully geyser of any make and capacity 25/50ltrs, dismantlingthe geyser for inspection, cleaning of tank, repalcement of defectivepart such as heating element, thermostat switch, spacer ring, safety plug, glass wool, neon lamp, head assembly, rubber gasket, top and bottom cover, inspection plate, copper cable 3 core, 3 pin Top plug, element holding clamp, welding of studs for head assembly, defective inner and outer shell reassembling the geysers with one coat of milky white synthetic enamel spray paint of approved quality after cleaning of all dust rust etc and writingof MES No on the geyser using black paint, Reinstallation of geysers to its original postion complete all as specified.Note :Spare parts such as heating element thermostat switch, spacer ring, heon lamp, head assembly, glass wool, safety plug rubber, gasket, copper cable, top & bottom cover, inspection plate, CP & PVC connection, Plug Top, Outer & Inner shell element holding clamps etcshall be measured & paid for seperately in respective itemshere in after. |
| 57 | Supply only heating element any type (i.e; Cup,thread or triangular) 1.5 KW,220/230 volts ISI marked complete all as specified and directed. |
| 58 | Supply only heating element any type (i.e; Cup,thread or triangular) 2.0 KW,220/230 volts ISI marked complete all as specified and directed. |
| 59 | Supply only Thermostat ISI marked complete all as specified and complete all as specified and as directed . |
| 60 | Supply onlyHead Assy \"Brass\" 8 to 9 holes suitable for 25 ltrs capacity all complete all as specified and as directed . |
| 61 | Supply onlySafety plug \"brass\" ISI marked suitable for 25/50 ltrs geyers complete all as specified and directed. |
| 62 | Supply only PVC connections 15mm size for Hot and cold water connection with rubber washer & brass nuts, ISI marked of length 600mm complete all as specified and directed. |
| 63 | Supply only copper flexible 3 core PVC insulated,PVC sheathed FR, ISI marked of size 2.5 sqmm copper conductor complete all as specified and directed. |
| 64 | Supply only geyser inner assembly of brass with inlet/outlet & over flow provision rubber washer suitable for 25 ltrs capacity all as specified and complete all as specified and as directed . |
| 65 | Supply only bottom cover plate in two halves with self toppiry suitable and as per sample complete all as specified and directed.Make :Bajaj, Peeco, Recold/DITZ |
| 66 | Supply only phase indicator red colour circular/rectangular shape as suitable and as per sample complete all as specified anddirected. |
| 67 | Supply and fixing in repairs non return brass valve of 15mm bore, ISI marked complete all as specified and as directed . |
| 68 | Supply and fixing in repairs pressure release brass valve of 15mm bore ISI marked complete all as specified and as directed . |
| 69 | Supply only PVC connections 15mm size for Hot and cold water connection with rubber washer & brass nuts, ISI marked of length 450mm complete all as specified and directed. |
| 70 | Supply and fixing in repairs Plug top 3 Pin 15 Amps 230 volts complete all as specified and as directed . |
| 71 | Material and labour for servicing including cleaning of condensor & eveporator coils fins with mild detergent and descaling of condensor coil forsplittype AC ofanymake/ capacity aftertaking down the whole unit and refixingat the existing locationor any other new location after servicing allas specified and directed.Note: Spare parts shall be measured and paid separately under relevant item. |
| 72 | Supply and fix in repairs Printed Circuit Board suitable for 1.5/2TR CapacitySplit Unit Air Conditioners including remote, etc. all as specified and as directed.NOTE: Make of PCB shall be of existing manufacturer as compatible with the AC. |
| 73 | Disconnecting, dismantling and taking out existing burnt out compressor fromwindow/Split type Air conditioner 1.5 TR Capacity and supply and fixing sealed unit compresser of existing capacity 1.5 TR, single phase, 230 V AC supply initialy filledwith compressor oil as speciifed by Engr-in-charge and testing on load for 24 hrs in summer. Make : LG/ Voltas/ Samsung complete all as specified and directed. |
| 74 | Disconnecting, dismantling and taking out existing burnt out compressor fromSplit type Air conditioner 2 TR Capacity and supply and fixing sealed unit compresser of existing capacity 2 TR, single phase, 230 V AC supply initialy filledwith compressor oil as speciifed by Engr-in-charge and testing on load for 24 hrs in summer complete all as specified and as directed.Make : LG/ Voltas/ Samsung |
| 75 | Supply and fix in repairs AC blower fan motor for ACsuitable for 1.5/2 TR AC suitable operate on 230 Volt AC supply at 50 Hz complete all as specified and directed. |
| 76 | Supply and fix in repairs insulationNytrile foam insulation suitable for 5/8 inch copper tube as per site requirement of approved makeall as specified and directed . |
| 77 | Supply and fix in repairs insulationNytrile foam insulation suitable for 1/4 inch copper tube as per site requirement of approved makeall as specified and directed . |
| 78 | Supply and fix in repairs Copper tube5/8 inch size as per site requirement of approved makeall as spd and directed . |
| 79 | Supply and fix in repairs Copper tube 1/4 inch size of approved makeall as specifiedand directed . |
| 80 | Supply and fix in replacement of Evaporator unit (indoor unit ) complete suitable for 1.5TRCapacity Split type Air Conditioners all as specified and as directed. Make : LG/ Voltas/Goderj |
| 81 | Supply and fix in replacement ofCondensing (Out door) unit complete including compressor, etc. Suitable for 1.5TRCapcity Air conditioners all as specified and as directed. Make : LG/Voltas/Goderj/Total line/Techmesh |
| 82 | Supply and fix in repairs Evaporator unit (indoor unit ) complete suitable for 2 TR Capacity Split type Air Conditioners 5 star rating with latest ISEER complete all as specified and directed. Make : LG/ Voltas/Goderj |
| 83 | Supply and fix in replacement ofCondensing (Out door) unit complete including compressor, etc. Suitable for 2 TRCapacity Air conditioners Make : LG/Voltas/Goderj/Total line/Techmesh |
| 84 | Supply and chargingR-134 gas to maintain the required cooling effect as and when required in the water cooler, Refrigerator and other cooling applinces incl. (charging cost incl in this item) all as specified and as directed. |
| 85 | Supply and fix in repairs Capacitor 45/50 MFD complete all as specified and directed. |
| 86 | Schedule of Credit (Minus) Rs.14135.00NOTE: Bidder shall insert credit amount of Rs. 14135.00 as ratein Green field under Col-13. |