| 1 | Erection of 11 KV (HT) Line(Note: For detailed specifications please refer attached SBD which forms a part of the tender) |
| 2 | Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles (410, SP-15) with pit excavation. (As per recommended IS/REC Standard) |
| 3 | G.I Channel/Flat/Angle in shape of Fabricated X-arm Top Bracket, Angle Braced, Clamp etc. |
| 4 | Supplying and fixing of 11 kV Pin Insulators (polymer) with Pins ( 5 KN) (As per recommended IS/REC Standard) |
| 5 | Supplying and fixing of 11 kV Disc Insulators (polymer) Complete with fittings (45KN) depending upon conductor size. (As per recommended IS/REC Standard) |
| 6 | Supplying and fixing of Galvanized Nuts and Bolts of sizes. |
| 7 | Supplying and fixing of Galvanized Stay Set with 50X8 mm Stay Clamp, Guy insulator (02 Nos) anchor plate (200x200x6mm) nut bolts, 2 nos. Turn buckles, 1.80 m long 16 mm diameter solid GS Stay rod & 7/3. 15 dia GI Stranded wire complete |
| 8 | Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site, Laying, stringing, binding and Jumperig of conductor including joints with PG clamps of required size30 mm2 ACSR ( Weasel) (As per recommended IS/REC Standard) |
| 9 | Supply and installation of 11 KV Link Set, 3-phase, 100A (As per recommended IS/REC Standard) |
| 10 | Earthing complete, G.I Rod 20 mm 2.5 Mtr. Long through G.I Wire |
| 11 | Cement Bottoming 1:2:4 Mix as per REC Standard 0.5 Cubic Mtr.Per Pole |
| 12 | Anti Clamping Device |
| 13 | Erection of 11/0.433 kV Distribution Transformer(Note: For detailed specifications please refer attached SBD which forms a part of the tender) |
| 14 | Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and installation of 250 KVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, Copper Wound, oil filled, with LT cable termination box with detachable Copper Gland Plate.(As per recommended IS/REC Standard) (with one year warranty) |
| 15 | Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles (410, SP-15) with pit excavation. (As per recommended IS/REC Standard) |
| 16 | Supply and installation of Gapless Surge Arrestor,9 kV,10 kA, LA with (polymer) housing, Station Type (As per recommended IS/REC Standard) |
| 17 | Supply and installation of 11 kV Horn,Gap Fuse Set, 3-phase, 100A (As per recommended IS/REC Standard) |
| 18 | Supply and installation of 11 kV Link Set, 3-phase, 100A (As per recommended IS/REC Standard) |
| 19 | Supply and fixing of Un Armoured Single Core PVC Cable 220 mm2 alongwith 12 no. Al. thimble 120 mm2 |
| 20 | Supplying and fixing of Galvanized Nuts and Bolts of sizes. |
| 21 | Supplying and fixing of 11 kV Pin Insulators (polymer) with Pins ( 5 KN) (As per recommended IS/REC Standard) |
| 22 | Supplying and fixing of 11 kV Disc Insulators (polymer) Complete with fittings (45KN) depending upon conductor size. (As per recommended IS/REC Standard) |
| 23 | Supplying and fixing of Angle Belt 1.5 Mtr for the protection of transformer |
| 24 | Supply and fixing of LT Distibution fuse set of standard making using clamps/thimbles with Brass Bolts and washers etc. Complete job as per REC standard (Drilling of holes Prohibited). |
| 25 | Supplying and fixing of Angle Brace for transformer bed |
| 26 | Supplying and fixing of Cross X-mar 2.8. Mtr |
| 27 | Cement Bottoming 1:2:4 Mix as per REC Standard 0.5 Cubic Mtr.Per Pole |
| 28 | Excavation of Earthing Pits of dia = 650 mm and depth= 3000 mm, Supplying and fixing of 3 No. sub station earthingby GI Pipe 40 mm or GI Rod 20mm, 2.5 mtr long through GI Strip of 50X6 mm 1 nofor neutral earthing and 25X3 mm 2 nos (for 2 Nos transformer body earth, 2 Nos Pole earth, 1 no. LA Earth and 1 no. GO handle earth). (Note: For LA Earth 1 pipe shall be kept separate) GI Nuts, Bolts and Clamps, refilled with earth enhancement materials and earthing chamber made of brick masonary with RCC Slab Cover. (As per recommended IS/REC Standard) |
| 29 | Erection of 1kM of LT Line on Conductor, 3-Ph, 4-wire, 2-Ph, 3-wire & 1-Ph, 2-wire(Note: For detailed specifications please refer attached SBD which forms a part of the tender) |
| 30 | Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles (410, SP-15) with pit excavation. (As per recommended IS/REC Standard) |
| 31 | Supply and fixing of Mukky clamps for LT Shackle insulators (As per recommended IS/REC Standard) |
| 32 | Supplying and fixing of Shackle Insulators (polymer) ( 16KN) (As per recommended IS/REC Standard) |
| 33 | Supplying and fixing of Galvanized Nuts and Bolts of sizes. |
| 34 | Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site, Laying, stringing and binding of conductor including joints with PG clamps of required size.30 mm2 ACSR (Weasel) (As per recommended IS/REC Standard) |
| 35 | Cement Bottoming 1:2:4 Mix as per REC Standard 0.5 Cubic Mtr.Per Pole |