Tender For Survey,Supply, Transportation, Carriage, Erection,Testing And Commissioning For Creation Of 3X250 Kva & 2X63 Kva Sub Station Alongwith Erection Of 11 Kv Line On 9 Mtr. Longst Poles, 30Mm Sqacsrweasel Conductor & Lt Line On 8 Mtr. St Poleat Wss , Sopore-Jammu And Kashmir

Power Development Department has published Tender For Survey,Supply, Transportation, Carriage, Erection,Testing And Commissioning For Creation Of 3X250 Kva & 2X63 Kva Sub Station Alongwith Erection Of 11 Kv Line On 9 Mtr. Longst Poles, 30Mm Sqacsrweasel Conductor & Lt Line On 8 Mtr. St Poleat Wss . Submission Date for this Tender is 06-01-2024. Electrification Work Tenders in Sopore Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

41156240
Tender For Survey,Supply, Transportation, Carriage, Erection,Testing And Commissioning For Creation Of 3X250 Kva & 2X63 Kva Sub Station Alongwith Erection Of 11 Kv Line On 9 Mtr. Longst Poles, 30Mm Sqacsrweasel Conductor & Lt Line On 8 Mtr. St Poleat Wss
Open Tender
Indian
Jammu And Kashmir
Sopore
06-01-2024

Tender Details

Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Creation Of 3X250 Kva & 2X63 Kva Sub Station Alongwith Erection Of 11 Kv Line On 9 Mtr. Longst Poles, 30Mm Sqacsrweasel Conductor & Lt Line On 8 Mtr. St Poleat Wss Kud Lower Under Jjm On Turnkey Basis.- 1 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 11 Kv Line On 9 Mtr. Long St Poles, 30Mm² Acsr Conductor At Wss Kud Lower Stage Filter Near Tandar Bridge. 2 9 Mtr. Long St Pole ( St-410 Sp-33 ) 3 Gi V Cross -Arm With Top Bracket Including Clamps 4 Gi Channel X-Arm Including Clamps And Angle For Braces 5 11 Kv Go Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical 6 30Mm² Acsr Weasel Conductor 7 Pg Clamps 8 11 Kv Polymer Composite Pin Insulator 12 Kv, 5 Kn, Lighting Impulse 75 Kv Positive And 80 Kv Negative, Creepage Distance 320Mm. 9 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45 Kn, Lightening Impulse 75Kvpositive And 80 Kv Negative, Creepage Distance 320Mm With Fitting 10 Galvanized Nuts And Bolts 11 Danger Plates With Clamps 12 Anti Climbing Device With Clamps 13 Earthing Complete Bygi Rod 20 Mm, 2.5 Mtr Long Through G.I. Strip 25X3 Mm 14 Painting Of 9 Mtr St Poles With Two Coats Of Aluminiumpaint. 15 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 16 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 17 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Installation Of 250 Kvaat Wss Kud Lower Stage Filter Near Tandar Bridge. 18 11 / 0.433 Kv, 3-Phase Distribution Transformer 250 Kva With Bimetallic Terminal Connectors Energy Level-2 Copperwound, & With Lv Cable Box Having Detachable Aluminium Gland Plate 19 Gapless Surge Arrestor, 9 Kv, 10 Ka , La With Polymer Housing Stn. Type 20 11 Kv Go Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical 21 11 Kv Horn Gap Fuse Set 3 Phase 200 A 22 300Mm² 1.1 Kv Grade, Pvc Insulated Stranded Conductor Frls Type 23 9 Mtr. Long St Pole ( St-410 Sp33 ) 24 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45 Kn, Lightening Impulse 75Positive And 80 Kv Negative, Creepage Distance 320Mm With Fitting 25 Gi Channel / Angle / Flat Of Sizes Including Clamps 26 Galvanized Nuts And Bolts. 27 Earthing Of Sub Stn. Excavation Of Earth Pit Of Dia 650Mm & Depth 3000Mm Installation Of Earthing Pipe Of 40Mm Nominal Bore & 4Mm Wall Thickness & Length 2.5 Mtr. Long As Per Is 1239. G.I Strip For Neutral Earthing Of Size 25Mmx3mmfor Connection Of Transforemr Body, Go Set & Lightening Arrestor As Per Is 2629 / 85, Gi Nuts & Bolts Refilled With Earth Enhancement Materials And Earth Chamber With Rcc Slab Cover 28 11 Kv Polymer Composite Pin Insualtor, 12 Kv, 5Kn Lightening Impulse 75 Kv Positve And 80 Kv Negative, Creepage Distance 320Mm 29 Lt Distribution Box For 250 Kva Dtr With Mccb For Incormer And SfuS For Outgoing Circuits. 30 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 31 Pg Clamps 32 Danger Plates With Clamps 33 Gi Barbed Wire For Anticlimbing 34 3-Phase Ht Trivector Meter With Ct Pt Unit 35 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 36 Painting Of St Poles 9 Mtr. Long With 2 Coat Of Al. Paint 37 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 3 Phase 4 Wire Lt Line On 8 Mtr. St Poles At Wss Kud Lower Stage Filter Near Tandar Bridge. 38 8 Mtr. Long St Poles ( St-410 Sp15 ) 39 Gi M Clamps For Shackle Insulator 40 50Mm²acsr Rabbit Conductor 41 Shackle Insulator 42 Galvanized Nuts And Bolts. 43 Danger Plates With Clamps 44 Anti Climbing Device With Clamps 45 Earthing Complete Bygi Rod 20Mm 2.5 Mtr. Long Through Gi Strip 46 Painting Of 8 Mtr St Poles With Two Coat Of Aluminium Paint 47 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 48 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 49 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 11 Kv Line On 9 Mtr. Long St Poles, 30Mm² Acsr Conductor At Wss Kud Lower Stage Teli Bari. 50 9 Mtr. Long St Pole ( St-410 Sp-33 ) 51 Gi V Cross -Arm With Top Bracket Including Clamps 52 Gi Channel X-Arm Including Clamps And Angle For Braces 53 11 Kv Go Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical 54 30Mm² Acsr Weasel Conductor 55 Pg Clamps 56 11 Kv Polymer Composite Pin Insulator 12 Kv, 5 Kn, Lighting Impulse 75 Kv Positive And 80 Kv Negative, Creepage Distance 320Mm. 57 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45 Kn, Lightening Impulse 75Kvpositive And 80 Kv Negative, Creepage Distance 320Mm With Fitting 58 Galvanized Nuts And Bolts 59 Danger Plates With Clamps 60 Anti Climbing Device With Clamps 61 Earthing Complete Bygi Rod 20 Mm, 2.5 Mtr Long Through G.I. Strip 25X3 Mm 62 Painting Of 9 Mtr St Poles With Two Coats Of Aluminiumpaint. 63 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 64 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 65 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Installation Of 250 Kvaat Wss Kud Lower Stage Teli Bari. 66 11 / 0.433 Kv, 3-Phase Distribution Transformer 250 Kva With Bimetallic Terminal Connectors Energy Level-2 Copperwound, & With Lv Cable Box Having Detachable Aluminium Gland Plate 67 Gapless Surge Arrestor, 9 Kv, 10 Ka , La With Polymer Housing Stn. Type 68 11 Kv Go Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical 69 11 Kv Horn Gap Fuse Set 3 Phase 200 A 70 300Mm² 1.1 Kv Grade, Pvc Insulated Stranded Conductor Frls Type 71 9 Mtr. Long St Pole ( St-410 Sp33 ) 72 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45 Kn, Lightening Impulse 75Positive And 80 Kv Negative, Creepage Distance 320Mm With Fitting 73 Gi Channel / Angle / Flat Of Sizes Including Clamps 74 Galvanized Nuts And Bolts. 75 Earthing Of Sub Stn. Excavation Of Earth Pit Of Dia 650Mm & Depth 3000Mm Installation Of Earthing Pipe Of 40Mm Nominal Bore & 4Mm Wall Thickness & Length 2.5 Mtr. Long As Per Is 1239. G.I Strip For Neutral Earthing Of Size 25Mmx3mmfor Connection Of Transforemr Body, Go Set & Lightening Arrestor As Per Is 2629 / 85, Gi Nuts & Bolts Refilled With Earth Enhancement Materials And Earth Chamber With Rcc Slab Cover 76 11 Kv Polymer Composite Pin Insualtor, 12 Kv, 5Kn Lightening Impulse 75 Kv Positve And 80 Kv Negative, Creepage Distance 320Mm 77 Lt Distribution Box For 250 Kva Dtr With Mccb For Incormer And SfuS For Outgoing Circuits. 78 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 79 Pg Clamps 80 Danger Plates With Clamps 81 Gi Barbed Wire For Anticlimbing 82 3-Phase Ht Trivector Meter With Ct Pt Unit 83 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 84 Painting Of St Poles 9 Mtr. Long With 2 Coat Of Al. Paint 85 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 3 Phase 4 Wire Lt Line On 8 Mtr. St Poles At Wss Kud Lower Stage Teli Bari. 86 8 Mtr. Long St Poles ( St-410 Sp15 ) 87 Gi M Clamps For Shackle Insulator 88 50Mm²acsr Rabbit Conductor 89 Shackle Insulator 90 Galvanized Nuts And Bolts. 91 Danger Plates With Clamps 92 Anti Climbing Device With Clamps 93 Earthing Complete Bygi Rod 20Mm 2.5 Mtr. Long Through Gi Strip 94 Painting Of 8 Mtr St Poles With Two Coat Of Aluminium Paint 95 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 96 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 97 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 11 Kv Line On 9 Mtr. Long St Poles, 30Mm² Acsr Conductor At Wss Kud Lower Stage Dogra. 98 9 Mtr. Long St Pole ( St-410 Sp-33 ) 99 Gi V Cross -Arm With Top Bracket Including Clamps 100 Gi Channel X-Arm Including Clamps And Angle For Braces 101 11 Kv Go Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical 102 30Mm² Acsr Weasel Conductor 103 Pg Clamps 104 11 Kv Polymer Composite Pin Insulator 12 Kv, 5 Kn, Lighting Impulse 75 Kv Positive And 80 Kv Negative, Creepage Distance 320Mm. 105 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45 Kn, Lightening Impulse 75Kvpositive And 80 Kv Negative, Creepage Distance 320Mm With Fitting 106 Galvanized Nuts And Bolts 107 Danger Plates With Clamps 108 Anti Climbing Device With Clamps 109 Earthing Complete Bygi Rod 20 Mm, 2.5 Mtr Long Through G.I. Strip 25X3 Mm 110 Painting Of 9 Mtr St Poles With Two Coats Of Aluminiumpaint. 111 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 112 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 113 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Installation Of 250 Kvaat Wss Kud Lower Stage Dogra. 114 11 / 0.433 Kv, 3-Phase Distribution Transformer 250 Kva With Bimetallic Terminal Connectors Energy Level-2 Copperwound, & With Lv Cable Box Having Detachable Aluminium Gland Plate 115 Gapless Surge Arrestor, 9 Kv, 10 Ka , La With Polymer Housing Stn. Type 116 11 Kv Go Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical 117 11 Kv Horn Gap Fuse Set 3 Phase 200 A 118 300Mm² 1.1 Kv Grade, Pvc Insulated Stranded Conductor Frls Type 119 9 Mtr. Long St Pole ( St-410 Sp33 ) 120 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45 Kn, Lightening Impulse 75Positive And 80 Kv Negative, Creepage Distance 320Mm With Fitting 121 Gi Channel / Angle / Flat Of Sizes Including Clamps 122 Galvanized Nuts And Bolts. 123 Earthing Of Sub Stn. Excavation Of Earth Pit Of Dia 650Mm & Depth 3000Mm Installation Of Earthing Pipe Of 40Mm Nominal Bore & 4Mm Wall Thickness & Length 2.5 Mtr. Long As Per Is 1239. G.I Strip For Neutral Earthing Of Size 25Mmx3mmfor Connection Of Transforemr Body, Go Set & Lightening Arrestor As Per Is 2629 / 85, Gi Nuts & Bolts Refilled With Earth Enhancement Materials And Earth Chamber With Rcc Slab Cover 124 11 Kv Polymer Composite Pin Insualtor, 12 Kv, 5Kn Lightening Impulse 75 Kv Positve And 80 Kv Negative, Creepage Distance 320Mm 125 Lt Distribution Box For 250 Kva Dtr With Mccb For Incormer And SfuS For Outgoing Circuits Box For 126 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 127 Pg Clamps 128 Danger Plates With Clamps 129 Gi Barbed Wire For Anticlimbing 130 3-Phase Ht Trivector Meter With Ct Pt Unit 131 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 132 Painting Of St Poles 9 Mtr. Long With 2 Coat Of Al. Paint 133 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 3 Phase 4 Wire Lt Line On 8 Mtr. St Poles At Wss Kud Lower Stage Dogra. 134 8 Mtr. Long St Poles ( St-410 Sp15 ) 135 Gi M Clamps For Shackle Insulator 136 50Mm²acsr Rabbit Conductor 137 Shackle Insulator 138 Galvanized Nuts And Bolts. 139 Danger Plates With Clamps 140 Anti Climbing Device With Clamps 141 Earthing Complete Bygi Rod 20Mm 2.5 Mtr. Long Through Gi Strip 142 Painting Of 8 Mtr St Poles With Two Coat Of Aluminium Paint 143 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 144 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 145 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 11 Kv Line On 9 Mtr. Long St Poles, 30Mm² Acsr Conductor At Wss Kud Lower Stage Borewell Sangyote. 146 9 Mtr. Long St Pole ( St-410 Sp-33 ) 147 Gi V Cross -Arm With Top Bracket Including Clamps 148 Gi Channel X-Arm Including Clamps And Angle For Braces 149 11 Kv Go Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical 150 30Mm² Acsr Weasel Conductor 151 Pg Clamps 152 11 Kv Polymer Composite Pin Insulator 12 Kv, 5 Kn, Lighting Impulse 75 Kv Positive And 80 Kv Negative, Creepage Distance 320Mm. 153 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45 Kn, Lightening Impulse 75Kvpositive And 80 Kv Negative, Creepage Distance 320Mm With Fitting 154 Galvanized Nuts And Bolts 155 Danger Plates With Clamps 156 Anti Climbing Device With Clamps 157 Earthing Complete Bygi Rod 20 Mm, 2.5 Mtr Long Through G.I. Strip 25X3 Mm 158 Painting Of 9 Mtr St Poles With Two Coats Of Aluminiumpaint. 159 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 160 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 161 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Installation Of 63 Kvaat Wss Kud Lower Stage Borewell Sangyote. 162 11 / 0.433 Kv, 3-Phase Distribution Transformer 63 Kva With Bimetallic Terminal Connectors Energy Level-2 Aluminium Wound, & With Lv Cable Box Having Detachable Aluminium Gland Plate 163 Gapless Surge Arrestor, 9 Kv, 10 Ka , La With Polymer Housing Stn. Type 164 11 Kv Go Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical 165 11 Kv Horn Gap Fuse Set 3 Phase 200 A 166 120Mm² 1.1 Kv Grade, Pvc Insulated Stranded Conductor Frls Type 167 9 Mtr. Long St Poles ( St-410 Sp33 ) 168 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45 Kn, Lightening Impulse 75Kvpositive And 80 Kv Negative, Creepage Distance 320Mm With Fitting 169 Gi Channel / Angle / Flat Of Sizes Including Clamps 170 Galvanized Nuts And Bolts. 171 Earthing Of Sub Stn. Excavation Of Earth Pit Of Dia 650Mm & Depth 3000Mm Installation Of Earthing Pipe Of 40Mm Nominal Bore & 4Mm Wall Thickness & Length 2.5 Mtr. Long As Per Is 1239. G.I Strip For Neutral Earthing Of Size 25Mmx3mmfor Connection Of Transforemr Body, Go Set & Lightening Arrestor As Per Is 2629 / 85, Gi Nuts & Bolts Refilled With Earth Enhancement Materials And Earth Chamber With Rcc Slab Cover 172 11 Kv Polymer Composite Pin Insualtor, 12 Kv, 5Kn Lightening Impulse 75 Kv Positve And 80 Kv Negative, Creepage Distance 320Mm 173 Lt Distribution Box For 63 Kva Dtr With Mccb For Incomer And SfuS For Outgoing Circuits 174 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 175 Pg Clamps 176 Danger Plates With Clamps 177 Gi Barbed Wire For Anticlimbing 178 3-Phase 4 Wire Lt Prodigy Meter With Box. 179 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 180 Painting Of St Poles 9 Mtr. Long With 2 Coat Of Aluminum Paint. 181 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 3 Phase 4 Wire Lt Line On 8 Mtr. St Poles At Wss Kud Lower Stage Borewell Sangyote. 182 8 Mtr. Long St Poles ( St-410 Sp15 ) 183 Gi M Clamps For Shackle Insulator 184 30Mm²acsr Weasel Conductor 185 Shackle Insulator 186 Galvanized Nuts And Bolts. 187 Danger Plates With Clamps 188 Anti Climbing Device With Clamps 189 Earthing Complete Bygi Rod 20Mm 2.5 Mtr. Long Through Gi Strip 190 Painting Of 8 Mtr St Poles With Two Coat Of Aluminium Paint 191 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 192 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 193 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 11 Kv Line On 11 Mtr. Long St Poles, 30Mm² Acsr Conductor At Wss Kud Lower Stage Tomator Morh. 194 11 Mtr. Long St Pole ( St-410 Sp-33 ) 195 Gi V Cross -Arm With Top Bracket Including Clamps 196 Gi Channel X-Arm Including Clamps And Angle For Braces 197 11 Kv Go Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical 198 30Mm² Acsr Weasel Conductor 199 Pg Clamps 200 11 Kv Polymer Composite Pin Insulator 12 Kv, 5 Kn, Lighting Impulse 75 Kv Positive And 80 Kv Negative, Creepage Distance 320Mm. 201 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45 Kn, Lightening Impulse 75Kvpositive And 80 Kv Negative, Creepage Distance 320Mm With Fitting 202 Galvanized Nuts And Bolts 203 Danger Plates With Clamps 204 Anti Climbing Device With Clamps 205 Earthing Complete Bygi Rod 20 Mm, 2.5 Mtr Long Through G.I. Strip 25X3 Mm 206 Painting Of 9 Mtr St Poles With Two Coats Of Aluminiumpaint. 207 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 208 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 209 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Installation Of 63 Kvaat Wss Kud Lower Stage Tomator Morh. 210 11 / 0.433 Kv, 3-Phase Distribution Transformer 63 Kva With Bimetallic Terminal Connectors Energy Level-2 Aluminium Wound, & With Lv Cable Box Having Detachable Aluminium Gland Plate 211 Gapless Surge Arrestor, 9 Kv, 10 Ka , La With Polymer Housing Stn. Type 212 11 Kv Go Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical 213 11 Kv Horn Gap Fuse Set 3 Phase 200 A 214 120Mm² 1.1 Kv Grade, Pvc Insulated Stranded Conductor Frls Type 215 9 Mtr. Long St Poles ( St-410 Sp33 ) 216 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45 Kn, Lightening Impulse 75Kvpositive And 80 Kv Negative, Creepage Distance 320Mm With Fitting 217 Gi Channel / Angle / Flat Of Sizes Including Clamps 218 Galvanized Nuts And Bolts. 219 Earthing Of Sub Stn. Excavation Of Earth Pit Of Dia 650Mm & Depth 3000Mm Installation Of Earthing Pipe Of 40Mm Nominal Bore & 4Mm Wall Thickness & Length 2.5 Mtr. Long As Per Is 1239. G.I Strip For Neutral Earthing Of Size 25Mmx3mmfor Connection Of Transforemr Body, Go Set & Lightening Arrestor As Per Is 2629 / 85, Gi Nuts & Bolts Refilled With Earth Enhancement Materials And Earth Chamber With Rcc Slab Cover 220 11 Kv Polymer Composite Pin Insualtor, 12 Kv, 5Kn Lightening Impulse 75 Kv Positve And 80 Kv Negative, Creepage Distance 320Mm 221 Lt Distribution Box For 63 Kva Dtr With Mccb For Incomer And SfuS For Outgoing Circuits 222 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 223 Pg Clamps 224 Danger Plates With Clamps 225 Gi Barbed Wire For Anticlimbing 226 3-Phase 4 Wire Lt Prodigy Meter With Box. 227 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 228 Painting Of St Poles 9 Mtr. Long With2 Coat Of Aluminum Paint. 229 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 3 Phase 4 Wire Lt Line On 8 Mtr. St Poles At Wss Kud Lower Stage Tomator Morh. 230 8 Mtr. Long St Poles ( St-410 Sp15 ) 231 Gi M Clamps For Shackle Insulator 232 30Mm²acsr Weasel Conductor 233 Shackle Insulator 234 Galvanized Nuts And Bolts. 235 Danger Plates With Clamps 236 Anti Climbing Device With Clamps 237 Earthing Complete Bygi Rod 20Mm 2.5 Mtr. Long Through Gi Strip 238 Painting Of 8 Mtr St Poles With Two Coat Of Aluminium Paint 239 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 240 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete

Key Value

Document Fees
INR 3000 /-
EMD
INR 307600.0 /-