Tender For Repair And Maintenance Of Street Light Timer Lt Panel Bus Bar And High Mast Light And Its Allied Services At Basoli And Janglote Under Ge Basoli, basoli-Jammu And Kashmir

Military Engineer Services has published Tender For Repair And Maintenance Of Street Light Timer Lt Panel Bus Bar And High Mast Light And Its Allied Services At Basoli And Janglote Under Ge Basoli. Submission Date for this Tender is 09-01-2024. Electrification Work Tenders in basoli Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

41066885
Corrigendum : Tender For Repair And Maintenance Of Street Light Timer Lt Panel Bus Bar And High Mast Light And Its Allied Services At Basoli And Janglote Under Ge Basoli
Open Tender
Indian
Jammu And Kashmir
Basoli
09-01-2024

Tender Details

Tender For Repair And Maintenance Of Street Light Timer Lt Panel Bus Bar And High Mast Light And Its Allied Services At Basoli And Janglote Under Ge Basoli; 1 Excavation In Trenches N.Exc 1.5 Mtr Wide And N.Exc 1.5Mtr In Depth For Foundation Of Pole And Laying Of Ug Cable And Getting Out In Any Type Of Soil Complete All As Specified And Directed. 2 Returning Filling In And Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exceeding 25Cm Completed All As Specified And Directed. 3 Removing Excavated Material N.Exc50m And Depositing Where Directed At A Level N.Exc 1.5M Above The Starting Point Complete All As Specified Anddirected. 4 M&L For Pcc ( 1 : 4 : 4 ) Type B-2 Using 40Mm Graded Crushed Stone Aggreghate F2r Foundation Of Poles And Stay Assembly Complete All As Specified And Directed.. 5 Supply And Laying In Trenches Or Passing Through Pipe Or Fixing To Pole / Wall Ug Cable Xlpe 16 Sqmm 4 Core, Pvc Insulated, Armoured Heavy Duty Electric Cable With Aluminum Conductor, 1100 Volts Grade, Complete All As Specified And Directed. Note : ( I ) Earth Work / Sand Cushioning Shall Be Measured And Paid Separately . 6 Taking Out The Old Unsvcablein Trenches Or Passing Through Pipe / Fixed To Pole / Wall Xlpe Insualted Any Size / Core Armourned Heavy Duty Electric Cable And Removing From Site Complete All As Specified And Directed. 7 S&F Dwc High Density Polyethelene Pipesin Replacement Having 63 / 50Outer Diamm, Inner As Per Site Requirement Having Corrugation On The Wall And Plain Surface On The Inner Wall Conforming To Is: 14930 ( Part I & Ii ) For Protection Of Underground Cable Laid Along Pole / Along Wall / In Pcc On Gl / Roof And Including All Fittings As Required At Sitecomplete All As Specified And Directed. 8 S&F Structural Steel Work Conforming To Grade Fe-410S As In Cross Arms, Bracing, Supports, Clamps And Back Plates Fabricated From Structural Steel Sections, Including , Nuts, Bolts, Washers, Welding , Bending Cold Or Hot Drilling Holes For Bolts In Any Shape Or Size As Indicated Or Directed And Inclusive Of One Primer Coat, One Under Coat , One Finishing Coat Of Aluminium Paint And Epoxy Coating, Including Taking Down Old Corroded Structural Steel Complete All As Specified And Directed. 9 S & F Of Street Light Control Panel Three Phase, 430 Volt Of Contractor Size 32 Amp Tp For Maximum Load 6 Kw Astronomical Type Confirms To Is / Iec60947-4-1 With Protecion Ip-54, Suitable For Outdoor Installation. Control Panel Having Extended Wide Bad Coil & Frls Internal Wiring Suitable Size. In Built Short Circuit Protection Should Be Prrvided And Complies With Class H Insulation. All Components ( I.E Astronomical Timer, Contractor, Mcb & Panel Should Be Same Oem ) Complete All As Specified And Directed 10 S & F Of Street Light Control Panel Three Phase, 430 Volt Of Contractor Size 65 Amp Tp For Maximum Load 12 Kw For Maximum Of Astronomical Type Confirms To Is / Iec60947-4-1 With Protecion Ip-54, Suitable For Outdoor Installation. Control Panel Having Extended Wide Bad Coil & Frls Internal Wiring Suitable Size. In Built Short Circuit Protection Should Be Prrvided And Complies With Class H Insulation. All Components ( I.E Astronomical Timer, Contractor, Mcb & Panel Should Be Same Oem ) Complete All As Specified And Directed 11 Supply And Fixin Repair / Replacementled Street Light Fitting Of Capacity 45 Watt Energy Saving & Environmental Friendly Long Life Versatile Pressure Die Cast Aluminiumwith Ptotection Ip66 And Impact Reistance Of Ik07 With High Power Leds As Light Suorce With Electronic Chip And Driverefficacy 100 Lm / W 5700 K Suitable For Pole Dia 54Mm ( Max ) Completeall As Specified And Directed 12 Supply And Fixin Replacementled Street Light Fitting Of Capacity 60 Watt Energy Saving & Environmental Friendly Long Life Versatile Pressure Die Cast Aluminiumwith Ptotection Ip66 And Impact Reistance Of Ik07 With High Power Leds As Light Suorce With Electronic Chip And Driver Efficacy 100 Lm / W 5700 Ksuitable For Pole Dia 54Mm ( Max ) Complete All As Specified And Directed 13 Supply And Fixin Replacement Flood Light Of Capacity 50 Watt Energy Saving & Environmental Friendly Long Life Versatile Pressure Die Cast Aluminiumwith Ptotectionip66 Made Out Pressure Die Cast Aluminium Housing Suitable Lens & Toughened Glass With High Power Leds As Light Source With Electronic Chip And Drivercompleteall As Specified And Directed 14 Supply And Fixin Replacement Flood Light Of Capacity 60 Watt Energy Saving & Environmental Friendly Long Life Versatile Pressure Die Cast Aluminiumwith Protectionip66 Made Out Pressure Die Cast Aluminium Housing Suitable Lens & Toughened Glass With High Power Leds As Light Source With Electronic Chip And Driver Completeall As Specified And Directed 15 Supply And Fixin Replacement Flood Light Of Capacity 150 Watt Energy Saving & Environmental Friendly Long Life Versatile Pressure Die Cast Aluminiumwith Protectionip66 Made Out Pressure Die Cast Aluminium Housing Suitable Lens & Tughened Glass With High Power Leds As Light Source With Electronic Chip And Driver Ofcompleteall As Specified And Directed 16 Supply And Fixin Replacement Flood Light Of Capacity 200 Watt Energy Saving & Environmental Friendly Long Life Versatile Pressure Die Cast Aluminiumwith Ptotectionip66 Made Out Pressure Die Cast Aluminium Housing Suitable Lens & Toughened Glass With High Power Leds As Light Source With Electronic Chip And Driver Ofcompleteall As Specified And Directed 17 Supply Andfixin Replacement For Junction Box Of Size 300X250x150mm Made Out Of 1.6 Mm Thick Crca Sheet Powder Coated Front Hinged Door With Openable And Self Closing Arrangements Including Aluminium Bus Bar3 Phase 4 Wire System Of Size 20Mm X 5Mm Fixed On Smc / Dmc Insulators And Cable Entry Glands For Connections And Mcb Sp 6 Amps-01 No All As Required And Fixed To Poles With Ms Clamp Made Out Of Ms Flat Iron Of Size 25X5mm And Including Nuts, Bolts And Washers Complete All As Specified And Directed. 18 Supply, Installing, Testing And Commissioning Factory Made And Tested Lt Panel Out Door Type, Platform Mounted Suitable For 3Phase 4 Wire, 50 Hz, Ac Supply System Base Bus Bar Chamber With Insulatedbusbar 375 Amps ( 3 Nos ) Phase And 150 Amps For Neutral Rating Installed On Porcelain Insulator. The Panel Shall Be Dust And Vermin Proof Ip65 Class Protection And Made Out Of 3.15 Mm Thick Crca Ms Sheet And 40 Mm X 40 Mm X 6 Mm Thick Angle Iron Frame Works, Powder Coated Finish Over One Coat Of Red Oxide Primer Outside Two Coats Of Red Oxide Primer Inside, Front Opening Type With Approns For Cable Ending With Double Door Shutter And Locking Arrangement ( Including Provn Of 65 Mm Godrej ( Freedom ) Lock With 2 Keys, Insulated Copper Conductor Frls Is-699 Marked 1100 Volt Grade But Seathed Cable Adequate Size But Not Less Than 4 Mm Size Complete All As Specified And Directed And Comporising Of Following:- ( A ) Mccb 100Amps, 4 Pole, 415 Volts 16 Ka Ics=100% Icu Including All Arrarngments. ( Incoming ) ( B ) Mcb 63 Amps Tp 16 Ka 415 Volts25 Ka Ics=100% Icu -1 No ( Outgoing ) ( C ) Mcb 32 Amps Spn, 10 Ka 230 Volts -3 Nos ( Outgoing ) ( D ) Ryb Led Indicator Lamp- 03 Nos ( E ) Digital Volt Meter With Selector Switch 0-500 Volts - 01 No

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 02-01-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-01-2024
2 18-12-2023 Corrigendum No 01 BOQ 02-01-2024
3 30-12-2023 Corrigendum No 02 Other 02-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
INR 15 Lakhs /-