Tender For Rewiring / Modernization / Modification Of Lab Area At Opf Kanpur.; 1 Demolition Of Cement Concretein Any Position ( Unreinforced ) Of Any Description And. 2 Demolition Of Brickwork Or Stone / Boulder Masonry, Laid Dry 3 M&L Brick Works With Sub Class B Bricks, Straight Or Curved On Plan Exceeding 6 Mtr Mean Radius Built In Cm 1:6 All As Specified And Directed By Eic &Sic 4 Taking Down Cement Plaster On Brick Wall Of Any Description Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water Etc. 5 Taking Down Existing Wall Panelling / False Ceiling And Similar Work 6 ( M&L ) Door Closer Aluminium Die Cast Body, Hydraulically Regulated Designation No. 3 Universal Type. 7 S / F 15 Mm Toughned Glass As In Hinged Doors, Partitions Automatic Doors And Similar Work Including Cutting To Shape, Drilling Holes Required. , Heavy Duty Hydraulic Double Action Floor Spring Along With Top Pin / Set Of Pivots Conforming To Is: 6315 Or Any Approved Make As Per Direction Of Engineer In Charge 8 ( M&L ) Brick Work With Sub Class ‘B’ Bricks Straight Or Curved On Plan Exc. 6M Mean Radius With 1:6 Cement Mortar Or As Directed By Eic / Sic. 9 ( M&L ) Cement Concrete ( 1:2:4 , 40Mm Graded Aggregated ) In Surface Channels And Drainsand Mass Concrete Or As Directed By Eic / Sic. 10 ( M&L ) Rcc In Column, Pillars, Posts And Struts 11 ( M&L ) Mild Steel Bars 10Mm Dia And Over, Cut To Length, Bent To Shap Required, Including Rings, Cranking Bending Spirally For Hooping For Columns, Hooking Ends And Binding With And Including Milding Steel Wire Or As Per Directive Of Eic / Sic. 12 Anodised Aluminium Snap Grid Frame Work For False Ceiling All As Specified 13 M&L 6Mm Thick Gypsum Board Ceiling Both Side Laminated Self Imposed Texture Boardsfixed To A Snap Grid Made Out Of Anodised Aluminium T-Sections ( Size Of Grid 605 Mm X605mm ) In Ceiling Complete All As Specified And As Directed. Note: The Aluminium Snap Grid Frame Work Shall Be Measured & Paid For Separately. 14 ( M & L ) 3Mm Thick Cement Base Wallcare Putty On Wall And As Directed By Eic / Sic. 15 ( M&L ) Preparation Of Oldsurfaces & Apply Two Coats Of Oil Bound Distemper As Directed By Eic / Sic. 16 ( M & L ) Rendering 15 Mm Thick On Fair Faces Of Brick Work Or Concrete Surface With Cement Plaster 1 : 4, Brushing Neat Cement Slurry With 3.0Kg Of Cement Per Sq. Metreall As Directed Byeic / Sic 17 Removing Building Materialsetc To A Distance Of 1.0 Km Or Under, Including Loading, Unloading And Stacking At The Destination. 18 Small Partition Work With Veneered Decorative Plywood 12 Mm , Grade 1 ( With Bwr Resin ) With Decorative Face Veneers On Both Faces; Fixed With Screws To Timber Frame Work Including All Assessary / Hardware 19 M / L Granite ( Of Any Type ) 20Mm Thick , Bedded And Jointed With Grey Cement Slurry And Pointed With White Cement With Admixture Of Pigment To Match The Shade Of Granite Stone Including Grinding And Polishing Complete 20 Providing Edge Moulding To 18-20Mm Thick Stone Of Counters Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete 21 Solid Pvc / Wpc Wall Lining Consisting Of 5Mm Thick Wood Grain Single Side Prelam Pvc Sheet Used Instead Of Plain Sheet And Fixing At Site As Per Requirement With Provision Of Decorative Laminate Type 1 Of Surface Finish 0.9 Mm Thick, Colour And Pattern As Approved, Fixed With Approved Adhesive As Per ManufacturerS Instruction 22 Providirg & Laying Of Special Congxund For Floor By Surfee Preparaion By Cleaning / Gnnding The Surface To Remove Any Dust, Dirt And Any Loose Material By Means Of Blower / Vaccume Cleaner Of Soaked Oil By Burning The Floor Only By Applying Covete Primer With 3Mm Screed, Applying Topcoat Of Self Leveling Epxoxy Compound 2Mm Thick Of Approved Colour By Spike Roller Myk Schomburg / Pedillte / Fosroc / Itwdevcon / Krayon Corporation / Asian / Sakshi Chem Science Pvt. Ltd Make Or Equivalent. The Construction Ard Expansion Joints Shall Be Filled With Flexible Sealing Compound And Made Good Before Applying Epoxy Compound To Avoid Cracks Etc. In Future, All As Specified & Directed By Engg-In-Charge. 23 ( M&L ) Preparation ( Rubbing Down And Stopping Of Existing Distempered / Painted Surfaces.Of Old Plastered Surfaces ) Of Walls And Applying Two Coats Of Coloured Exterior Acrylic Water Emulsion Paint ( 1St Quality ) Over And Including 2.8 To 3 Mm Thick Birla White / Jk White / Berger Wall Putty ( To Achieve Smooth Surfaces ) And A Coat Of Acrylic Primer As Specified And Approved Shade As Per Directed By Sic / Eic. Make: Apex Ultima ( Asian ) Or All Guard Weather Coat ( Berger, Shalimar, Nerolac ) Or Equivalent As Per Approved By Sic / Eic. 24 S / F Chimney Auto Clean Wall And Ceiling Mounted , Filterless Technologywith A Motion Sensor. The Combination Of Its Beautiful Appearance And Toughened Quality . Maximum Suction Capacity Chimney Comes With A Suction Capacity Of 1500 Cubic Meters Per Hour, As It Is Less Noisy, Low On Maintenance, And Energy-Efficient.With A Baffle Filter . Oil Collector, 3 Led Lamps .Heat Auto-Clean Technology. Including Chimney Pipe ( Flexible Aluminium Exhaust Duct Pipe 10 Feet ) 6 Inch Hose Pipe ( 7 M ) For Each. 25 S / F Sound Proof Kitchen Sink Heavy-Duty Premium Quality Chrome Matt Finish ( 24×18×10 ) Including All Accessories And Fittings. 26 S / F Brass Automatic Touchless Sensor Faucet Tap ( Chrome ) Sense-One Pillar Tap Faucet Including All Accessories And Fittings. 27 S / F Brass, Concealed Circular Body Diverter Full Set With Overhead Shower, Hand Shower And Bath Tub Spout ( Chrome ) Faucet Set 28 S / F Of Powder Coating Aluminum Doors / 2-Track Or 3-Track Aluminium Sliding Window, Frame Section Weighing 0.85 To 1.1 Kg / M And Shutters Aluminum Section Weighing O.55Kg / Mnot More Than 4 Sqm , Including Half Part With Glazing , 4.8 Mm Thick First Quality Glasss Necessary And Half With Pre Laminated Board 12Mm, Interior Grade Both Sides Laminated Joining Cleats Glazing Clips Riber Neoprene Packing Handles 2 Nos In Each Door / Window Hings, Latches, Tower Bolts, Door Aldrops, Door Stopers, Powder Coating Snap Beading Screws Etc. Complete All As Specified. 29 Manufacturing, Supplying And Fixing Retro Reflective Mandatory / Regulatory Sign Boards Of 900 Mm Diametre With Support Length Of 3750 Mm And Made Up Of 2 Mm Thick Aluminium Sheet, Face To Be Fully Covered With High Intensity Encapsulated Type Heat Activated Retro Reflective Sheeting Conforming To Type - Iv Of Astm-D 4956-01 In Blue And Silver White Or Other Colour Combination Including Subject Matter, Message ( Bi-Lingual ) , Symbols And Borders Etc. As Per Irc ; 67:2001, Pasted On Substrate By An Adhesive Backing Which Shall Be Activated By Applying Heat And Pressure Conforming To Class -2 Of Astm-D-4956-01 And Fixing The Same With Suitable Sized Aluminium Alloy Rivets @ 20 Cm C / C To Back Support Frame Of M.S. Angle Iron Of Size 25X25x3 Mm Along With Theft Resistant Measures, Mounted And Fixed With 2 Nos. M.S. Angles Of Size 35X35x5 Mm To A Vertical Post Made Up To M.S. Tee Section Ismt 50X50x6 Mm Welded With Baseplate Of Size 100X100x5 Mm At The Bottom End And Including Making Holes In Pipes, Angles Flats, Providing & Fixing M.S. Message Plate Of Required Size, Steel Work To Be Painted With Two Or More Coats Of Synthetic Enamel Paint Of Required Shade And Of Approved Brand & Manufacture Over Priming Coat Of Zinc Chromate Yellow Primer ( Vertical Ms-Tee Support To Be Painted In Black And White Colours ) .Backside Of Aluminium Sheet To Be Painted With Two Or More Coats Of Epoxy Paint Over And Including Appropriate Priming Coat Including All Leads And Lifts Etc. Complete As Per Drawing , Specification And Direction Of Engineer-In-Charge. 30 Credit Of Old / Un-Usable Fals Celing / Particle Boardpanelling Including Grid Any Type And Size. 31 Credit Of Existing Steel Window / Door 32 Credit Of Old Bricks 33 Credit Of Old Brick Bats 34 ( One Light Point Or One Fan Point Controlled By One Switch With Cables 2.5 Sq. Wiring With Copper Conductor Cables Frls. Pvc Single Core, Sheathed Cable M&L 35 ( M & L ) One 3 Pin Socket Outlet. 15 Amps, Independent, With Copper Cables 4 Sq. Mm Size With Pvc Conduit 36 ( M & L ) Modular Switch 1 Way 6A, 1 Module 37 ( M& L ) Modular Box With Cover Plate 3 Moduel 38 ( M& L ) Modular Box With Cover Plate 3 Moduel 39 ( S & F ) Socket 6A / 16A - 2 / 3 Pin Combined, 2 Module, 40 Supplied & Fixed, 240 V, 20 Amp, Single Pole 41 Supplied & Fixed 415 V, 32 Amp, Triple Pole And Earth Encolsure With A Three Pin And Earth Plug With Socket Complete With One Triple Pole Mcb. 42 Supply And Fixing Led Luminaire 600 Mm X 600 Mm, 40Watt, 220 V Ac Recessed Type With High Efficiency Pmma Diffuser Soft Glare Free Light Complete Efficiency Pmma Diffuser Soft Glare Free Light Complete With Driver, Holders & Led Lamp Suitable For Roof Ceiling Including Connecting Up With Driver Three Core Flexible Copper Conductor Cases Of Suitable Size 43 Taking Down Carefully Copper / Aluminium Point Wiring ( Light, Fan, Socket Or Power ) Complete, ( Fittings Such As Switches, Ceiling Roses, Pendants, Regulators Sockets Etc. To Be Measured Separately ) , Removing Materials To Store For Keeping In Safe Custody For Reuse At Site And Making Gooddisturbed Surfaces Of Walls, Floors, Etc. 44 Circuit 2X1.5 Sq. Mm + 1X1.0 Sq. Mm Earth Wire In Pvc Conduit ( S&F ) 45 Circuit 2X6.0 Sq. Mm + 1X4.0 Sq. Mm Earth Wire, ( S&F ) In Pvc Conduit 46 Circuit 4X6.0 Sq. Mm + 2X4.0 Sq. Mm Earth Wire, In Pvc Conduit ( S&F ) 47 Isolator Four Pole Supplied & Fixed 415V, 100A 48 Isolator Tpn Supplied & Fixed, 415V, 40A 49 Cutting Holes In Brick Walls In Mud Mortar For Inserting Holdfasts And Making Good Dismantled Portion In Cement Mortar 1:3 Or Cement Concrete 1:2:4 Type B-1 As Required But In Brick Walls Built In Cement Mortar Or Cement Lime Mortar And Stone Walls Built In Lime Mortar, Depth Of Embedded Portion Of Holdfasts Or Lugs Measured From The Face Of The Jamb Into The Wall 50 Cuttingcutting Chases, Pinning In. Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; And Cutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Etc., And Making Good, Cutting Not Exc 10 Cm Girth 51 M&L Xlpe Insulated, Armoured, Heavy Duty Electric Cable Withaluminium Conductor, 1100 Volts Grade, Cross-Sectional Area 35 Sq. Mm 3 .5Core 52 Supplied & Fixed Isolator Sp 240V, 40A 53 M&L Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit / Pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required 2Mm Dia Galvanised Iron Or Steel Wire 54 M&L Ceiling Rose, 3 Phase / Pvc / Polycarbonate, Isolated Body 55 Tpn, Db, Dd, 8Way 415 V 56 S & F Wall Bldcfan Market Rate 57 Electrical Pannel 58 Indoor / Outdoor Machine1 Air-Conditioning System With Ceiling Suspended Ductable Units Along With Associated Works:High Static Ducatable Inverter Heating Cooling Ceiling Mounted Unit With Independent Circuit Energy Efficienct Scroll Compressor With 410 Gas Filled Capacity-11 Tr ( Including All Taxes Gst Etc ) 59 Installation / Commissioning Work ( Including All Taxes Gst Etc ) :Ducting Tata / Sail / Including Duct Support, Angle Frame, Nut Bolt Etc, 24 G, 22 G.Acoustic Lining Of Duct With 13 Mm Open Cell Nitrile Rubber Insulation With Suitable Adhesive From Inside Of Duct.Thermal Duct Insulation With 9 Mm Nitrile Shet With Factory Laminated Metpet Cladding.Suction And Discharge 16 / 18G Copper Piping Of Required Size From Indoor To Outdoor Unit With Insulation 9 Mmelectrical Work And Associated Cabling4cx 5Mm1c X 1.5 Mm8swg Earthing Wireyou Have To Provide Us With The Required Incomer Power And Earthing Along With Main Switch At Outdoor Panel. Rates Are Included With Required Control Panelinitial Nitroget Testing, Ref. 410 Gar Charging, Commissioningv.I. Padscanvass Connectionms Fabricated Outdoor Standvoltage Stablizers, If Required To Botain Voltage As Under: 415V + / - %, Three Phas, 50 Cycles