Provision Of Electrical Installation And Other Allied Works. Construction Of Recreation Centredhalao, Military Road Under Ward 84 Kbz.; 1 Civil Item 2 10.18:Providing And Fixing Circular / Hexagonal Cast Iron Or M.S. Sheet Box For Ceiling Fan Clamp, Of Internal Dia 140 Mm, 73 Mm Height, Top Lid Of 1.5 Mm Thick M.S. Sheet With Its Top Surface Hacked For Proper Bonding, Top Lid Shall Be Screwed Into The Cast Iron / M.S. Sheet Box By Means Of 3.3 Mm Dia Round Headed Screws, One Lock At The Corners.Clamp Shall Be Made Of 12 Mm Dia M.S. Bar Bent To Shape As Per Standard Drawing . 3 110.10:Providing And Fiving Name Board Made Of Ms Sheet 90X60cm, 1Mm Thick With Frame Of Ms Angle 50X50x6mm, Two Diagonal Braces At The Back Of The Sheet Of Ms Flat 40X6mm, Total Height Of The Board Above Ground Level 2.40M, Length Of Legs Below Ground 0.30M Embedded In Cc Block 1:2:4 ( 1 Cement: 2 Coarse Sand: 4 Graded Stone Aggregate 20Mm Nominal Size ) 30X30x45cm Including Excavation And Removal Of Surplus Earth With In 50M Lead, Applying Priming Coat Of Approved Steel Primer, Painting With Synthetic Enamel Paint Of Approved Quality And Lettering With Enamel Paint Of Approved Colour ( One Side ) As Per Drawing / Direction Of Engineer-In-Charge 4 Sr Items 5 Od14343 / 2023-2024:Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cmm / W ) Minimum 6.85, Air Delivery Minimum 215 Cmm, 350 Rpm ( Tolerance As Per Is : 374- 2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. 6 Od14344 / 2023-2024:Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recessed Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. ( B ) 25 Mm 7 Od14345 / 2023-2024:Supply, Installation, Testing And Commissioning Of 3Mm ( Min. ) Acp Sheet Based, Acrylic Raised Letters Led Board With 1X1 M.S. Square Pipe Box Type Frame, Pipe Frame All Open Sides Covered By G.I. Sheet Properly. 8 Od14346 / 2023-2024:P / F Abc Type ( Stored Pressure ) Fire Extinguisher 6 Kg Capacity Isi Mark With Map 70 % Filled With Map Powder Complete In All Respect I / C Fixing Arrangement Etc Complete As Reqd. 9 Od14347 / 2023-2024:Sitc Of Single Phase Monoblock Pump Set Complete With All Accessories Workable On 240 / 415 Volt 50 Hz Ac Supply ( A ) 1 Hp ( 0.75Kw ) Single Phase Pump Set Head From 12-30 Metre Suction And Delivery 25X25 Mm 10 Od14348 / 2023-2024:Supply Of 15 ( 380Mm ) Sweep 1400 Rpm Exhaust Fan Heavy Duty Complete With Shutter, Blade Etc As Reqd. 11 Od14349 / 2023-2024:Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. ( B ) 63 Amps 12 Od14350 / 2023-2024:Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 12 Way, Double Door 13 Od14351 / 2023-2024:Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Reqd. Upto 450 Mm Sweep 14 Od14352 / 2023-2024:Supplying And Fixing Following Size Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 12 Module ( 200Mmx150mm ) 15 Od14353 / 2023-2024:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 6 Pin 15 / 16 Amp Socket Outlet 16 Od14354 / 2023-2024:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3 Pin 5 / 6 Amp Socket Outlet 17 Od14355 / 2023-2024:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 15 / 16 Amp Switch 18 Od14356 / 2023-2024:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 5 / 6 Amps Switch 19 Od14358 / 2023-2024:S / D Following Size Of Frls Pvc Insulated Copper Conductor 1 Core Cable In Existing Surface / Recessed / Pvc / Steel Conduitas Reqd. ( D ) 3X 6 Sq Mm 20 Od14359 / 2023-2024:S / D Following Size Of Frls Pvc Insulated Copper Conductor 1 Core Cable In Existing Surface / Recessed / Pvc / Steel Conduitas Reqd. ( C ) 6X2.5 Sq Mm 21 Od14360 / 2023-2024:S / D Following Size Of Frls Pvc Insulated Copper Conductor 1 Core Cable In Existing Surface / Recessed / Pvc / Steel Conduitas Reqd. ( A ) 3X2.5 Sq Mm 22 Od14361 / 2023-2024:Wiring For Light / Power Plug With 4X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit Alongwith 2 Nos 4 Sq. Mm Fr Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 23 Od14362 / 2023-2024:Wiring For Light / Power Plug With 2 X 4 Sqmm Frlspvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit Alongwith 1 No 4Sqmm Frpvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 24 Od14363 / 2023-2024:Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, CCurve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole 25 Od14366 / 2023-2024:Wiring For Light / Fan Point / Exhaust Fan Point Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recess Medium Class Pvc Conduit With Modular Switch, Modular Plate, Suitable Size Gi Box And Earthing The Point With 1.5Sqmm Fr Pvc Insulated Copper Conductor Single Core Cable Etc As Required. Group C 26 Od14367 / 2023-2024:Providing And Fixing Following Rating And Breaking Capacity Mccb In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required. ( A ) 100 Amp16 Ka 27 Od14365 / 2023-2024:Laying Of One No Pvc Insulated And Pvc Sheathed / Xple Al Conductor Armoured Power Cable Of 1.1Kv Grade Of Size Not Exceeding 25Mm2 On Surface As Required. Upto 35 Sq. Mm ( Clamped With 1Mm Thick Saddle ) 28 Od14368 / 2023-2024:Earthing With G.I. Earth Plate 600Mmx600mmx6mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. ( But Without Charcoal / Coke And Salt ) As Required. 29 Od14369 / 2023-2024:Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 Volts, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 25 Amps 30 Od14370 / 2023-2024:Providing And Fixing 25Mmx5mm Gi Strip On Surface Or In Recess For Connections Etc As Reqd. 31 Od14371 / 2023-2024:Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required. Upto 35 Sq. Mm 32 Od14372 / 2023-2024:Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface / Recessed Conduit / Submain Wiring / Cable As Required. 33 Od14561 / 2023-2024:Supply, Installation, Testing And Commissioning Of 50Mmx50mmx6mm Angle Iron Mounting Stand For Acp Sign Board And Painting With Primer And Finished Paint As Required. 34 App Items 35 122.2.2: P / Fhot Press Sheet Mouldedcompound ( Smc ) Fire Retardant ( Temp. Resistance Up To 200 C ) , Ip 55 Weather Proof Polebox Of Innerdimension 200X160x98mm ( Ns ) Complete With Suitable Arrangement For Fixing Of 2 Nosof 6 To 32 Amp Single Pole Mcb & 63 Amp. Doublepole Isolator ( Mcb / Isolator Excluded ) Withneutral Link Duly Shorting On Din Channel With2 Nos Of Ms Clamps With Ss Back Plateofsuitable Size With Danger Monogram Property Printed On The Coveretc Asreqd. Asreqd. 36 122.2.30.A:Sitc Of 150W Led Flood Light Luminaire Fitted With Lens, Made Of Pressure Die Cast Aluminium Housing & Toughened Glass Cover Complete With The Following Specification As Reqd With Ip 66 Protection ( A ) Total System Wattage =150 Watt + / - 5% ( B ) Luminaire Efficacy>=100 Lm / W ( C ) Power Factor>=0.95 ( D ) Protection Class- Ip-66 37 122.2.38:S / I / T / C Of Surface Mounting Crca Housing 36W Led Luminaire With Acrylic Cover Diffuser With Following Specifications Including Fixing On Existing Wall / Recess With Connections As Reqd. ( A ) Total System Wattage = 36 Watt + / - 5% ( B ) Luminous Efficacy >=95 Lumens / Watt. ( C ) Power Factor >=0.95 38 122.2.39:S / I / T / C Of Led Tube Type Luminaire 20 Watt Rating Complete With Polycarbonate Housing Batten Integrated Electronic Driver Prewired With High Efficient Leds With The Following: ( A ) Total System Wattage 20 Watt + / - 5% ( B ) Luminous Efficacy Lumens / Watt >=95 ( C ) Power Factor >=0.95 39 122.2.83:Supply, Installation, Testing And Commissioning Of Power Distribution Board Made Out Of 1.6 Mm Sheet Steel, Epoxypowder Coated , Specially Designed Al Bus Bar 400A To 630A With Heat Shrinkcable Colour Coated Sleeves Suitable For Accommodating Mccbs / Mcbs / Isolators As Incoming And Outgoing As Required ( Without Mccbs / Mcbs / Isolators ) Complete With Digital Meter Module, Including Voltmeter Ammeter With Selector Switch, Cts Control Fuse And Indicating Lights Including Connections Etc. As Required ( Conforms To Is:8623 ) 40 122.2.84:Supplying And Fixing Of Full Stainless Steel Body Self-Contained Drinking Water Cooler With Cooling Capacity 150Ltr Per Hr, Storage Capacity 150Ltr And Suitable For 230V Supply As Required. 41 122.2.111:Supply And Fixing Of 4.5 Kg Dcp With Co2 Gas Cartridge Fire Extinguisher ( Conforming To Is:2171 With Cylinder Fully Charged ) 42 122.1.3:Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-2C*10 Sqmm