Construction Of Toilets & Bathrooms & Covered Cycle Parking Stand For Hostel Block B8 & B9 At South Campus Of Iit Mandi.Note:-1. Quoted Rate Should Be Inclusive Of All Applicable Taxes Including Gst ( Nothing Extra Shall Be Payable ) .2. All Statutory Deduction Will Be Made As Per Prevailing Rates.; 1 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In - Charge. Nominal Concrete 1:3:6 Or Richer Mix ( I / C Equivalent Design Mix ) Pipes, Cables Etc. Exceeding 80 Mm Dia. But Not Exceeding 300 Mm Dia. All Kinds Of Soil All Complete As Per The Direction Of Engineer-In-Charge. 2 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. All Kinds Of Soil All Complete As Per The Direction Of Engineer-In-Charge. 3 Excavating Trenches Of Required Width For Pipes, Cables, Etc Including Excavation For Sockets, And Dressing Of Sides, Ramming Of Bottoms, Depth Up To 1.5 M, Including Getting Out The Excavated Soil, And Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc. And Disposing Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M : All Kinds Of Soil Pipes, Cables Etc. Exceeding 80 Mm Dia. But Not Exceeding 300 Mm Dia Pipes, Cables Etc. Exceeding 80 Mm Dia. But Not Exceeding 300 Mm Dia. All Kinds Of Soil All Complete As Per The Direction Of Engineer-In-Charge. 4 Excavating Holes More Than 0.10 Cum & Up To 0.5 Cum Including Getting Out The Excavated Soil, Then Returning The Soil As Required In Layers Not Exceeding 20 Cm In Depth, Including Consolidating Each Deposited Layer By Ramming, Watering Etc, Disposing Of Surplus Excavated Soil, As Directed Within A Lead Of 50 M And Lift Upto1.5 M. All Kinds Of Soil All Complete As Per The Direction Of Engineer-In-Charge. 5 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) All Complete As Per The Direction Of Engineer-In-Charge. 6 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 ( 1 Cement : 4 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources ) All Complete As Per The Direction Of Engineer-In-Charge. 7 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Sizederived From Natural Sources ) All Complete As Per The Direction Of Engineer-In-Charge. 8 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete All Complete As Per The Direction Of Engineer-In-Charge. 9 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers All Complete As Per The Direction Of Engineer-In-Charge. 10 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More All Complete As Per The Direction Of Engineer-In-Charge. 11 Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) All Complete As Per The Direction Of Engineer-In-Charge. 12 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approvedmake, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete All Complete As Per The Direction Of Engineer-In-Charge. 13 Extra For Providing Frosted Glass Panes 4 Mm Thick Instead Of Ordinary Float Glass Panes 4 Mm Thick In Doors, Windows And Clerestory Window Shutters. ( Area Of Opening For Glass Panes Excluding Portion Inside Rebate Shall Be Measured ) All Complete As Per The Direction Of Engineer-In-Charge. 14 Providing And Fixing Aluminium Tower Bolts Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc. Complete :150X10 Mm All Complete As Per The Direction Of Engineer-In-Charge. 15 Providing And Fixing Aluminium Handles Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc. Complete : 125 Mm All Complete As Per The Direction Of Engineer-In-Charge. 16 Providing And Fixing Pvc Rigid Foam Sheet 1Mm Thick On Existing Door Shutters ( Bathroom And W.C. Doors ) Using Synthetic Rubber Based Adhesive All Complete As Per The Direction Of Engineer-In-Charge. 17 Providing And Fixing Fly Proof Stainless Steel Grade 304 Wire Gauge, To Windows And Clerestory Windows Using Wire Gauge With Average Width Of Aperture 1.4Mm In Both Directions With Wire Of Dia. 0.50 Mm All Complete With 12 Mm Mild Steel U Beading All Complete As Per The Direction Of Engineer-In-Charge. 18 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) : For Fixed Portion Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) All Complete As Per The Direction Of Engineer-In-Charge. 19 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) : For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately ) . Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) All Complete As Per The Direction Of Engineer-In-Charge. 20 Providing And Fixing 12Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is:12823 Grade L Type Ll, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer-In-Charge.Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side All Complete As Per The Direction Of Engineer-In-Charge. 21 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) With Float Glass Panes Of 4.0 Mm Thickness ( Weight Not Less Than 10 Kg / Sqm ) All Complete As Per The Direction Of Engineer-In-Charge. 22 Filling The Gap In Between Aluminium Frame & Adjacent Rcc / Brick / Stone Work By Providing Weather Silicon Sealant Over Backer Rod Of Approved Quality As Per Architectural Drawings And Direction Of Engineer-In-Charge Complete Upto 5Mm Depth And 5 Mm Width All Complete As Per The Direction Of Engineer-In-Charge. 23 Providing And Fixing Brass 100Mm Mortice Latch And Lock With 6 Levers Without Pair Of Handles ( Best Make Of Approved Quality ) For Aluminium Doors Including Necessary Cutting And Making Good Etc. All Complete As Per The Direction Of Engineer-In-Charge. 24 Providing And Fixing Aluminium Round Shape Handle Of Outer Dia 100Mm With Ss Screws Etc. Complete As Per Direction Of Engineer-In-Charge Powder Coated Minimum Thickness 50 Micron Aluminium As Per The Direction Of Engineer-In-Charge. 25 Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete As Per The Direction Of Engineer-In-Charge. 26 Steel Work In Built Up Tubular ( Round, Square Or Rectangular Hollow Tubes Etc. ) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete Hot Finished Welded Type Tubes All Complete As Per The Direction Of Engineer-In-Charge. 27 Providing And Fixing Stainless Steel ( Grade 304 ) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature ( Wherever Required ) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I / C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-Incharge, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc. ) All Complete As Per The Direction Of Engineer-In-Charge. 28 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm ( Thickness To Be Specified By The Manufacturer ) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Pointing The Joints With White Cement And Matching Pigment Etc. All Complete As Per The Direction Of Engineer-In-Charge. 29 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) Single Socketed Pipes. 75 Mm Diameter All Complete As Per The Direction Of Engineer-In-Charge. 30 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) Single Socketed Pipes. 110 Mm Diameter All Complete As Per The Direction Of Engineer-In-Charge. 31 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is :5382 Leaving 10 Mm Gap For Thermal Expansion. Coupler 75Mm All Complete As Per The Direction Of Engineer-In-Charge. 32 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is :5382 Leaving 10 Mm Gap For Thermal Expansion. Coupler 110Mm All Complete As Per The Direction Of Engineer-In-Charge. 33 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is :5382 Leaving 10 Mm Gap For Thermal Expansion. Single Tee With Door 75X75x75 Mm All Complete As Per The Direction Of Engineer-In-Charge. 34 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is :5382 Leaving 10 Mm Gap For Thermal Expansion. Single Tee With Door 110X110x110 Mm All Complete As Per The Direction Of Engineer-In-Charge. 35 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is :5382 Leaving 10 Mm Gap For Thermal Expansion. Single Tee Without Door 75X75x75 Mm All Complete As Per The Direction Of Engineer-In-Charge. 36 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is :5382 Leaving 10 Mm Gap For Thermal Expansion. Single Tee Without Door 110X110x110 Mm All Complete As Per The Direction Of Engineer-In-Charge. 37 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is :5382 Leaving 10 Mm Gap For Thermal Expansion. Bend 87.5°75 Mm Bendall Complete As Per The Direction Of Engineer-In-Charge. 38 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is :5382 Leaving 10 Mm Gap For Thermal Expansion. Bend 87.5°110 Mm Bendall Complete As Per The Direction Of Engineer-In-Charge. 39 Providing And Fixing Terminiual Guard 110Mm Dia All Complete As Per The Direction Of Engineer-In-Charge. 40 Providing And Fixing Greating 110Mm Dia All Complete As Per The Direction Of Engineer-In-Charge. 41 Providing And Fixing Floor Trap 110Mm Dia All Complete As Per The Direction Of Engineer-In-Charge. 42 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hardwood Plugs, Screwed With M.S. Screws Of Required Length Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete. 110 Mm All Complete As Per The Direction Of Engineer-In-Charge. 43 Design, Supply, Fabrication & Installation Of Roof For Different Shape Consisting Of Single Skin Minimum 6.00Mm Thick Polycarbonate Transparent Sheet, Uv Stablized, Properly Jointed And Fixed With M.S.Frame, Fasteners, Gutters, Gaskets, Sealants And Necessary Structural Supports As Required As Per Approved Drawings And Specifications. The Work Includes Preparation Of Shop Drawings As Per ManufacturerS Specifications And Approved Architectural Drawings Complete Etc. Which Shall Be Approved By Engineer-In-Charge. ( M.S. Frame Work Shall Be Paid Separately ) All Complete As Per The Direction Of Engineer-In-Charge. 44 12 Mm Cement Plaster Of Mix : 1:4 ( 1 Cement: 4 Coarse Sand ) All Complete As Per The Direction Of Engineer-In-Charge. 45 Distempering With 1St Quality Acrylic Distemper ( Ready Mixed ) Having Voc Content Less Than 50 Gms / Litre, Of Approved Manufacturer, Of Required Shade And Colour Complete, As Per ManufacturerS Specification. Two Or More Coats On New Work All Complete As Per The Direction Of Engineer-In-Charge. 46 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work All Complete As Per The Direction Of Engineer-In-Charge. 47 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete All Complete As Per The Direction Of Engineer-In-Charge. 48 Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required : W.C. Pan With Isi Marked White Solid Plastic Seat And Lid All Complete As Per The Direction Of Engineer-In-Charge. 49 Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin Of 430X260x350 Mm And 340X410x265 Mm Sizes Respectively With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.I Clamps Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required : Range Of Two Urinal Basins With 5 Litre White P.V.C. Automatic Flushing Cistern All Complete As Per The Direction Of Engineer-In-Charge. 50 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm Dia Cp Brass Single Hole Basin Mixer Of Approved Quality And Make, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required:- ( A ) White Vitreous China Wash Basin Size 550X400 Mm With A 15 Mm Cp Brass Single Hole Basin Mixerall Complete As Per The Direction Of Engineer-In-Charge. 51 Providing And Fixing White Vitreous China Pedestal For Wash Basin Completely Recessed At The Back For The Reception Of Pipes And Fittings All Complete As Per The Direction Of Engineer-In-Charge. 52 Providing And Fixing 8 Mm Dia C.P. / S.S. Jet With Flexible Tube Upto 1 Metre Long With S.S. Triangular Plate To Eureopean Type W.C. Of Quality And Make As Approved All Complete As Per The Direction Of Engineer-In-Charge. 53 Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. Flexible Pipe 32 Mm Dia All Complete As Per The Direction Of Engineer-In-Charge. 54 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers All Complete As Per The Direction Of Engineer-In-Charge. 55 Providing And Fixing Toilet Paper Holder : C.P. Brassall Complete As Per The Direction Of Engineer-In-Charge. 56 Providing And Fixing Ptmt Towel Ring Trapezoidal Shape 215 Mm Long, 200 Mm Wide With Minimum Distances Of 37 Mm From Wall Face With Concealed Fittings Arrangement Of Approved Quality And Colour, Weighing Not Less Than 88 Gms All Complete As Per The Direction Of Engineer-In-Charge. 57 Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour 450 Mm Long Towel Rail With Total Length Of 495 Mm, 78 Mm Wide And Effective Height Of 88 Mm, Weighing Not Less Than 170 Gmsall Complete As Per The Direction Of Engineer-In-Charge. 58 Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I / C Cutting And Making Good The Walls Etc. : Internal Work – Exposed On Wall. 20 Mm Dia. Nominal Bore All Complete As Per The Direction Of Engineer-In-Charge. 59 Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I / C Cutting And Making Good The Walls Etc. : Internal Work – Exposed On Wall. 25 Mm Dia. Nominal Bore All Complete As Per The Direction Of Engineer-In-Charge. 60 Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I / C Making Good The Walls Etc. Concealed Pipe, Including Painting With Anticorrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 15 Mm Dia. Nominal Bore All Complete As Per The Direction Of Engineer-In-Charge. 61 Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc. : External Work 20 Mm Dia. Nominal Bore All Complete As Per The Direction Of Engineer-In-Charge. 62 Making Connection Of G.I. Distribution Branch With G.I. Main Of Following Sizes By Providing And Fixing Tee, Including Cutting And Threading The Pipe Etc. Complete : 25 To 40 Mm Nominal Bore All Complete As Per The Direction Of Engineer-In-Charge. 63 Providing And Fixing Brass Stop Cock Of Approved Quality : 15 Mm Nominal Bore All Complete As Per The Direction Of Engineer-In-Charge. 64 Providing And Fixing Brass Stop Cock Of Approved Quality :20 Mm Nominal Bore All Complete As Per The Direction Of Engineer-In-Charge. 65 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : 20 Mm Nominal Bore All Complete As Per The Direction Of Engineer-In-Charge. 66 Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 45 Cm Length 15 Mm Nominal Bore All Complete As Per The Direction Of Engineer-In-Charge. 67 Providing And Fixing C.P. Brass Shower Rose With 15 Or 20 Mm Inlet : 100 Mm Diameter All Complete As Per The Direction Of Engineer-In-Charge. 68 Providing And Fixing G.I. Union In G.I. Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete ( New Work ) 15 Mm Nominal Bore All Complete As Per The Direction Of Engineer-In-Charge. 69 Providing And Fixing G.I. Union In G.I. Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete ( New Work ) 20 Mm Nominal Bore All Complete As Per The Direction Of Engineer-In-Charge. 70 Providing And Fixing G.I. Union In G.I. Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete ( New Work ) 25 Mm Nominal Bore All Complete As Per The Direction Of Engineer-In-Charge. 71 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank All Complete As Per The Direction Of Engineer-In-Charge. 72 Providing And Fixing C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms. 15 Mm Nominal Bore All Complete As Per The Direction Of Engineer-In-Charge. 73 Providing And Fixing C.P. Brass Stop Cock ( Concealed ) Of Standard Design And Of Approved Make Conforming To Is:8931.15 Mm Nominal Bore All Complete As Per The Direction Of Engineer-In-Charge. 74 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 : 15Mm Nominal Bore All Complete As Per The Direction Of Engineer-In-Charge. 75 Providing And Fixing C.P. Brass Extension Nipple ( Size 15Mmx50mm ) Of Approved Make And Quality All Complete As Per The Direction Of Engineer-In-Charge. 76 Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138 Mm, Breadth 102 Mm, Height Of 75 Mm With Concealed Fitting Arrangements. Weighing Not Less Than 106 Gms All Complete As Per The Direction Of Engineer-In-Charge. 77 Cutting Holes Up To 30X30 Cm In Walls Including Making Good The Same: With Common Burnt Clay F.P.S. ( Non Modular ) Bricks All Complete As Per The Direction Of Engineer-In-Charge. 78 Providing And Fixing Square-Mouth S.W. Gully Trap Class Sp-1 Complete With C.I. Grating Brick Masonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size ( Inside ) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design: 100X100 Mm Size P Type With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 All Complete As Per The Direction Of Engineer-In-Charge. 79 Providing And Laying Non-Pressure Np2 Class ( Light Duty ) R.C.C. Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement : 2 Fine Sand ) Including Testing Of Joints Etc. Complete : 150 Mm Dia. R.C.C. Pipe All Complete As Per The Direction Of Engineer-In-Charge. 80 Constructing Brick Masonry Manhole In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) With R.C.C. Top Slab With 1:1.5:3 Mix ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) : 3 Graded Stone Aggregate 20 Mm Nominal Size ) , Foundation Concrete 1:4:8 Mix ( 1 Cement : 4 Coarse Sand ( Zone-Iii ) : 8 Graded Stone Aggregate 40 Mm Nominal Size ) , Inside Plastering 12 Mm Thick With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) Finished With Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : Inside Size 90X80 Cm And 45 Cm Deep Including C.I. Cover With Frame ( Light Duty ) 455X610 Mm Internal Dimensions, Total Weight Of Cover And Frame To Be Not Less Than 38 Kg ( Weight Of Cover 23 Kg And Weight Of Frame 15 Kg ) : With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 All Complete As Per The Direction Of Engineer-In-Charge. 81 Extra For Depth For Manholes Size 90X80 Cm With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5All Complete As Per The Direction Of Engineer-In-Charge.