Tender For Mainline Laying And Combined Station Works For Natural Gas Pipeline From Hazaribagh To Ranchi -8.625 Od, Noida-Uttar Pradesh

Indian Oil Corporation Limited-IOCL has published Tender For Mainline Laying And Combined Station Works For Natural Gas Pipeline From Hazaribagh To Ranchi -8.625 Od. Submission Date for this Tender is 18-01-2024. Gas Pipe Line Tenders in Noida Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41003701
Corrigendum : Tender For Mainline Laying And Combined Station Works For Natural Gas Pipeline From Hazaribagh To Ranchi -8.625 Od
Open Tender
Indian
Uttar Pradesh
Noida
18-01-2024

Tender Details

Mainline Laying And Combined Station Works For Natural Gas Pipeline From Hazaribagh To Ranchi -8.625 Od

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Jan-2024 Addendum-1 Date 15-01-2024
2 12-Jan-2024 Addendum-2 Other 15-01-2024
3 15-Jan-2024 Addendum No 3 Date 18-01-2024

Key Value

Document Fees
Refer document
EMD
INR 2836000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:Mainline laying & Combined Station Works for Natural Gas Pipeline from Hazaribagh to Ranchi (8.625” OD)
Sl. No. Item Description
1GST % for the tender Please select the rate of GST in cell AY13. Rate selected shall be applicable for the entire BoQ.
2ML Laying
3\"Laying of Owner-supplied pre-coated mild steel line pipes, including arranging all additional land/construction corridor, beyond Ow ner\"s ROU/ROW, required for Contractor\"s storage, fabrication, access for construction site, movement of construction equipment etc. , receiving and taking over Owner-supplied materials, handling, transportation etc. from Owner\"s issue point to work site, stringingalong Right of Way (ROW)/ pipeline corridor,providing labour, equipment and supply of other inputs & materials/ consumables neces sary to perform and complete the work in all respects in accordance with the contract including, but not limited to, the following w orks:- - Taking delivery of pre-coated/ bare pipes from the designated stockpile location (loading of pipes onto pipe trailors placed insid e stockpile by mainline contractor shall be done by Owner\"s authorized agency), including placing of pipe trailors for taking delive ry of pipes from designated stockpile, carrying out holiday detection and verification of pipes at the time of taking delivery), tra nsportation of pipes to ROW/ work site/ Contractor\"s storage location etc., - Clearing and grading of ROW/ pipeline corridor, cutting of trees, vegetation etc. including keeping record of trees cut, includingde-watering etc., - Stringing of pipes along ROW including providing straw bags/ soft padding below pipe (in Rocky areas requiring blasting for prepar ation of trench, pipes shall be strung after the blasting operation and clearing of trench as per instructions of Site Engineer/ Eng ineer-in-Charge), - Trenching to all depths to maintain clear earth cover as per specification and to fit minimum bend radius, by excavation in all ki nds of terrain & soil, including stripping top soil to a depth of 30cm to the full anticipated width of the ditch and storing this m aterial separately along the ROW to allow re-depositing of the same on top of the backfilled ditch (in cultivable and other areas sp ecially designated by Owner), - Carrying out repair of pipe & coating defects for defects occurring after \"\"taking over\"\" of pipes from Owner, replacement in the case of non-repairable defects and repairing damages to pipe coating including defects/ damages occurring during transportation & ha ndling, - Aligning, bending, lining up, cutting and beveling (as required) of pipes for field adjustments, welding (manual / semi-automatic / automatic), physical inspection of all weld joints by qualified welding engineer/ inspector & carrying out repair of weld-joints f ound defective, -Carrying out 100% radiographic inspection (by X-Ray) of all field weld joints, destructive testing of one weld joint in each Spreadas per specification and direction of Site Engineer, including providing Crawler type Automatic X-Ray machine and external X-Ray ma chine and all other requisite equipment, labour, supervision, materials, approved films, approved consumables, all facilities and pe rsonnel to process, develop, examine and interpret radiographs (by qualified and experienced Radiography Inspector), providing all f acilities to Owner\"s representative(s) for examining radiographs and other tests as required, carrying out repair of weld-joints fou nd defective, carrying out re-radiography and other tests as required on repaired joints, etc., ..... Continuation in next line\"
48.625\" OD
5\"Laying submerged crossings using pipes with or without concrete sheathing across major water course crossings and providing all wor ks,labour, inputs and materials/consumable necessary to perform and complete the work in all respects in accordance with the contrac t, including taking delivery and transportation of Owner-supplied coated pipes to the work site from designated stockpile location, inspection of the coated pipes visually and with holiday detector for defects, arranging all necessary intermediate storage area req uired thereof till the pipes are installed in permanent position, arranging the required additional land for construction purpose, p reparation of site, aligning, bending, lining up and welding the pipe, 100% radiographic inspection of weld joints, coating of fieldweld joints, holiday detection and repair of coating, hydrotesting (both pre- & post-installation) and replacement of pipes/ defect s, excavation of the trench to required depth, as per specifications, in all kinds of soil and conditions including rock trenching a nd maintenance of trench in all kinds of soil including rocky strata, if any, making bunds for stoppage of water flow, de-watering i ncluding installation of well-point system, and laying of the pipeline in approved trench, including de-watering, providing in-situ concreting at coated weld joints to effectively secure the HDPE conduit with mainline pipe, providing \"\"Band IT\"\" make stainless ste el (SS) strips / clamps of 3/4\"\" width for tying HDPE conduit with mainline pipe (two strips per pipe length), backfilling and finalclean-up, stabilisation of the excavated banks by additional means, disposal of waste and surplus in accordance with the contract, and supply of materials (other than those specifically undertaken to be supplied by the Owner under the contract) necessary for or i n the performance of the work or fortemporary or permanent incorporation in the works and allotheracts, matters and things nec essary to complete the pipeline/ crossings in all respects according to the contract and as per directions of Site Engineer/ Enginee r-in-Charge. NOTE : I)Depending upon the site condition & location of each submerged crossing, the Engineer-in-Charge, in consultation with the Contract or, shall decide upon the precise operations necessary for the performance of the work to lay the pipeline across the canal/ drain/ rivers and the cost of all such operations necessary shall be deemed to have been included in the rate for this item. II)Profile of drain / canal bed, ground & top of laid pipe shall be established jointly in presence of Owner both before and after l aying the crossing, by taking levels with reference to nearby permanent structure. III)The banks of the crossing shall be stabilised and suitable brick/ stone masonry bank protection works shall be carried out for t he entire ROW width to prevent bank erosion leading to exposure of the pipeline. The procedure for such measures shall be submitted for Owner\"s approval prior to execution. IV)Concrete sheathing work for submerged crossings shall be paid for separately under relevant item of Schedule of Rates.\"
68.625\" OD
7\"Laying pre-coated pipes in Marshy areas with concrete sheathing including providing all equipment, works,labour, inputs and materia ls/consumable necessary to perform and complete the work in all respects, submission of construction procedure for Owner\"s approval,arranging the required additional land for construction purpose, preparation of site including dewatering, aligning, bending, linin g up and welding the pipe, 100% radiographic inspection of weld joints, coating of field weld joints, holiday detection and repair o f coating, hydrotesting testing and replacement of pipes/ defects, excavation of the trench to required depth in all kinds of soil a nd conditions including rock trenching and maintenance of trench in all kinds of soil including rocky strata, if any, and laying of the pipeline in approved trench, backfilling and final clean-up, stabilisation of the excavated banks, disposal of waste and surplusin accordance with the contract, and supply of materials (other than those specifically undertaken to be supplied by the Owner unde r the contract) necessary for or in the performance of the work or fortemporary or permanent incorporation in the works and allo theracts, matters and things necessary to complete the work in all respects according to the contract. NOTE: 1.Depending upon the site condition, the Engineer-in-Charge, in consultation with the Contractor, shall decide upon the precise op erations necessary for the performance of the work to lay the pipeline across the canal/drain/rivers and the cost of all such operat ions necessary shall be deemed to have been included in the rate for this item. 2.Concrete sheathing work for marshy area laying shall be paid for separately under relevant item of Schedule of Rates. 3. Measurement for this item shall be as per pipe book covering laying in Marshy portion covering laying in Marshy portion covering entire concrete sheathing work only.\"
88.625\" OD
9\"Execution of road/other crossing by Shallow Horizontal Directional Drilling (HDD) technique including mobilization & de-mobilizatio n at site(s), supply of all materials as per the `Scope of Supply\" and all consumables, equipment, manpower & other resources and ar ranging the required land for site preparations and execution of, but not limited to, the following works in accordance with the spe cifications, drawings and as per all provisions of the contract document complete in all respect as per the instructions of the Engi neer – in – charge /Site engineer. Taking delivery and transportation of Owner-supplied 3LPE coated pipes to the work site from designated stockpile location, inspecti on of the coated pipes visually and/or with holiday detector for defects, including arranging all necessary intermediate storage are a required thereof till the pipes are installed in permanent position. Complete site preparation including arranging of required land, setting up of fabrication yard, preparation of temporary arrangementfor pipeline stringing, launching etc Carrying out repair of pipe defects, replacement in the case of non-repairable defects and repairing damages to pipe coating includi ng defects/ damages occurring during transportation and handling. String preparation including repair of pipe and pipe coating defects, welding, non-destructive testing of welds including 100% radio graphy (by X-ray), supply of films & all equipment and providing all facilities to Owner\"s representative(s) for examining radiograp hs, repair of defects in the welds and re-testing etc. Carrying out pre-installation hydrostatic testing of the complete pipeline string, as per the specifications, including repair of de fects and retesting etc. Coating of the field joints of the pipe string to be installed by shallow HDD method with DIRAX heat shrink sleeves of M/s Raychem\"smake, DDXTM Directional Drilling Kit of M/s Canusa or of any other approved make used for HDD crossings. Repair of all coating damages in the pipe section to be laid by shallow HDD method by full encirclement sleeves using suitable cut s ections of approved quality of heat shrink sleeves of M/s Raychem make, DDXTM Directional Drilling Kit of M/s Canusa or of any otherapproved make. Repair of all coating damages in the pipe section to be laid by shallow HDD method by full encirclement sleeves using suitable cut s ections of approved quality of heat shrink sleeves of M/s Raychem make, DDXTM Directional Drilling Kit of M/s Canusa or of any otherapproved make. Fabrication of 89mm OD steel conduit with an inner duct of 40mm OD HDPE pipe for OFC (wherever OFC has to be laid along with the car rier pipeline). Supply & fixing of easy to install heat shrinkable duct end caps for HDPE conduit for OFC (wherever OFC has to be laid along with th e carrier pipeline). ... continuation in next line\"
10\"... in continuation to the previous line Installation of the pipeline and OFC conduit as a bundle crossing below the Road/ other utility horizontally by shallow HDD operatio n to the correct profile as per the approved drawings in a pre-reamed hole of appropriate. Carrying out post-installation coating survey as per approved procedure. Restoration, clean-up and disposal of drilling fluid, waste and all other surplus materials etc. All other works not specifically listed herein, but required as per specifications, drawings, provisions of the contract document, c alculations and construction method statement, leading to successful completion of the works. Note :- The item to be operated under the specific instruction of Engineer in Charge\"
118.625\"
12\"Providing & Laying Concrete sheathing on the carrier pipe i.e., continuous concrete coating (mix 1:1.5:3) using specified (approved ) wire mesh reinforcement as per approved drawing and technical specifications, including supply of cement, steel wire mesh, aggrega te, sand, shuttering and all other materials, consumables, inputs, equipment for concrete sheathing required to complete the job, te sting of concrete coated pipes etc. and as per direction of Engineer-in-Charge. NOTE: I) Payment shall be made for the actual length of pipe coated with concrete. Ends of pipe left uncoated/ shall not be considered in the concrete coating length II) The rates shall include compensation for additional hardship caused in handling and/ or lowering the pipe with concrete coating.The above item shall be executed at the discretion and directions of Engineer-in-Charge. III) The rates shall include the concrete sheathing / coating over weld joints in order to arrive at continuously concrete coated pi peline. This weld joint concrete sheathing / coating shall be applied after the hydrostatic pre-test.\"
138.625\"
14\"Extra for rock trenching for Mainline laying (covered under relevant item of this SOR) as classified by the Engineer-in-Charge and performed by pneumatic tools or by drilling and blasting or by chiselling out including cost of all equipment, materials, labour, co nsumables & inputs to complete the work (excluding sand padding around mainline pipe which shall be paid separately) as per specific ations, approved procedure and instructions of Engineer-in-Charge. Note: 1.Payment shall be made for rock actually excavated at site or calculated based on the trench dimensions stipulated in the specifica tions / drawings, whichever is less. 2.Item shall be operated under specific instructions from Engineer-in-Charge. 3.Controlled Blasting operation shall be carried out only by authorized and trained / skilled manpower, as per approved procedure, a nd taking due care & precaution to adjoining property, people, livestock etc., with due approval from Engineer-in-Charge 4.Sand padding around mainline pipe shall be paid separately as per relevant item in SOR 5. Additional 150 mm depth of excavation to be carried out in rocky area (for pipe trench) to accommodate sand padding\"
15\"Supplying, providing and filling fine sand in trenches in hard rocky stretches (Excluding additional 150mm deep trenching forrocktrenching) around mainline pipe for providing a minimum padding thickness of 150 mm on top as well as at bottom of the mainline pip e. NOTE: (i) Item to be operated under specific instructions from Engineer-in-Charge (ii) Cost of additional depth of 150mm trenching for this item shall be paid separetly under item for \"\"Extra for Rock trenching\"\"\"
168.625\"
17\"Supplying, providing and filling Soft Soil in trenches in hard rocky stretches (excluding additional 150mm deep rock trenching) aro und mainline pipe for providing a minimum padding thickness of 150mm on top as well as at bottom of the mainline pipe. In all cases where rock or gravel or moorum or hard soil is encountered in the bottom of the trench, trench padding, Rock Shield Mat erials and sand/soft soil bags as approved by OWNER/Engineer-in-Charge, shall be provided to safeguard the pipe coating. Padding mat erials shall be graded soil/other suitable material containing no gravel, rock, or lumps of hard soil. The graded soil for padding s hall pass through sieve size ASTM-10 or ISO-2.00. Acceptable padding shall be placed under the pipeline before its installation and around it after installation, to establish at both sides and on top of the pipe a permanent layer of padding. The thickness of compa cted padding shall be at least 150mm. The trench shall be deeper by at least 150mm. The trench shall be evenly and sufficiently padded to keep the pipe, when in place, atleast 150mm above the bottom of excavated trench. NOTE: (i) Item to be operated under specific instructions from Engineer-in-Charge (ii) Cost of additional depth of 150mm trenching for this item shall be paid separetly under item for \"\"Extra for Rock trenching\"\"\"
188.625\"
19\"Supplying, providing and filling fine sand in trenches in stretches other than normal soil and hard rock / boulder stretch (includi ng additional 150mm deep trenching) around mainline pipe for providing a minimum padding thickness of 150 mm on top as well as at bo ttom of the mainline pipe for the complete specified trench width NOTE: (i) Item to be operated under specific instructions from Engineer-in-Charge (ii) Cost of additional depth of 150mm trenching for this item shall be included in this item itself\"
208.625\"
21\"Supplying, providing and filling soft soil in trenches in stretches other than normal soil and hard rock (including additional 150m m deep trenching) around mainline pipe for providing a minimum padding thickness of 150mm on top as well as at bottom of the mainlin e pipe. Padding materials shall be sand/graded soil/other suitable material containing no gravel, rock, or lumps of hard soil. The graded so il for padding shall pass through sieve size ASTM-10 or ISO-2.00. Acceptable padding shall be placed under the pipeline before its i nstallation and around it after installation, to establish at both sides and on top of the pipe a permanent layer of padding. The th ickness of compacted padding shall be at least 150mm. The trench shall be deeper by at least 150mm. The trench shall be evenly and sufficiently padded to keep the pipe, when in place, atleast 150mm above the bottom of excavated trench. NOTE: (i) Item to be operated under specific instructions from Engineer-in-Charge (ii) Cost of additional depth of 150mm trenching for this item shall be included in this item itself.\"
228.625\"
23\"Supplying & providing approved type of extruded polyethylene mesh (rock shield) on mainline pipe to protect the coating against roc ky soil including supply of all inputs such as labour, materials, consumables etc. necessary to perform and complete the work in allrespects in accordance with the specifications, manufacturer\"s recommendation and instructions of Site Engineer / Engineer-in-Charg e. NOTE: 1. Proper lateral as well as transvers overlap shall be provided as per specifications/ manufacturers recommendation\"
248.625\"
25Supply of all materials necessary for fabrication and installation of kilometre posts, direction markers and warning signs at the lo cations as per specifications, excavating & grouting in cement concrete 1:3:6, and all other works necessary for fabrication & insta llation of the markers including cleaning, priming & applying two coats of coal tar based epoxy paint on underground portions, suppl y and application of one coat of primer and two coats of epoxy paint of approved colour and quality on overground portion, stencil l etter cutting for number, direction, chainage etc. and restoration of site to original condition and all other acts, deeds, matters and things and work, labour, inputs and materials/ consumables necessary to perform and complete the work in all respects as per app roved drawing & specifications and as per direction of Site Engineer / Engineer-in-Charge.
26KILOMETER POST
27DIRECTION MARKER
28WARNING SIGN
29Providing and installing RCC (1:1.5:3) boundary pillars as per drawings on both edges of the ROW at 250 metres interval and at everyturning point and/or as directed, including supply of all materials necessary for the fabrication of the pillars, casting and inscr ibing the pillars, excavation of earth, fixing the pillars & backfilling, applying two coats of oil paint over one coat of cement ba sed primer on exposed surface and work, labour, inputs & materials/ consumables necessary to perform and complete the work in all re spect under the contract and as per directions of Site Engineer.
30Carrying out air drying of the pipeline system as per specification and direction of Engineer-in-Charge including supply of all labo ur, materials, equipments, instruments, pigs, barrels etc. complete in all respects.
318.625\"
32Carrying out Nitrogen Purging of the pipeline system as per specification and direction of Engineer-in-Charge including supply of al l labour, materials, equipments, instruments, pigs, barrels etc. complete in all respects.
338.625\"
34Mobilisation/ demobilisation of pigging tools, tackles, consumables, accessories and personnel by contractor at work site including magnetic pig, electronic geometry pig, pig tracking device, preparation and cleaning of the complete mainline / Mainline sections in cluding HDD sections under this tender (but excluding HDD crossings not included under the scope of this tender and to be executed b y separate agency) by running series of pigs for cleaning the line from debris, water & making it dry for launching calliper pigs, r unning of magnetic pig for cleaning of ferrous residue, launching and receiving the electronic & standard calliper pigs, including p ig tracking at 5 to 10 km interval, data retrieval, interpretation of data and submission of reports in the form acceptable to the O wner, including rectification of defects observed from calliper survey, including supply of all labour, materials, equipment & instr uments, calliper pigs, fabrication of launching & receiving barrels, all complete for ascertaining the geometry of the pipeline.
358.625\"
36Preservation of entire pipeline / pipeline sections (including HDD sections) by using inhibited water with uniform inhibitor concent ration adequate for 6 (six) months preservation period as per manufacturer\"s recommendation including arranging water, testing of wa ter, supply of inhibitor, all equipment, manpower, consumables etc. complete as per specifications and direction of Site Engineer / Engineer-in-Charge.
378.625\"
38Taking delivery of MOVs for mainline from Owner\"s stockpile/ godown, preparation of pup pieces of specified length from owner suppli ed pipes of higher wall thickness, welding of pup pieces to both sides of valves, providing instrument tappings in MOVs, hydrostatic ally testing the valves & installing at designated locations on the mainline in accordance with the specifications and drawings, wel ding & 100% radiography of weld joints, repair of weld joints etc., complete in all respect including all works and material in foun dation, RCC underground valve supports etc., including PU Coating of underground portions and painting of overground portions / valv e enclosure etc. with aluminium paint over a coat of primer, and including supply of all materials (other than those specifically un dertaken to be supplied by the Owner), consumables & inputs complete as per specifications, drawings & instructions of Site Engineer/ Engineer-in-Charge.
398.625\"
40\"Carrying out tieing-in and hook-up of mainline pipe with the HDD sections of pipeline (executed by other agency) (Optional) on eith er side of the HDD pipe section , including excavation/ trenching in all kinds of soil including rock, cutting of pipe, making fieldbends out of pre-tested pipes to match the site requirement, welding, carrying out 100% radiography, field joint coating, holiday d etection, repair of damaged coating, backfilling and making through the pipeline etc. complete in all respects. Note: This item shall be operated under specific instructions of Engineer-in-Charge.\"
418.625\"
42Taking delivery and transportation ofbare pipes from owner\"s stockpile, transportation, unloading the pipes at manufacturer\"s work s and fabrication of Long Radius (R=6D) Hot pulled induction bends having tangent length of approximately 1000m at both ends as per specification and delivery of hot pulled bends to site including visual examination, manual U.T. on the entire weld seam, bevelling of ends as per API 5L, supply of all materials, consumables, labour etc. as per specifications and direction of Site Engineer / Engi neer-in-Charge.
438.625\"
44\"Supply of all materials, consumables, providing all equipment & resources for the complete activity of commissioning of Liquid Petr oleum Gas Pipeline (LPG) including Mainline and Stations with proper pressurization of mainline and station piping with Nitrogen, ba tch pigging followed by vaporized LPG and effective line fill by pressurization of line fill LPG as per approved procedure and Speci fication requirementincluding providing expert services for vetting of commissioning procedure and presence of expert to guide & m onitor the complete commissioning activities, providing all supervisory/expert services, other manpower and all resources for the ex ecution of the complete service meeting with international practices and standards, observing all statutory and other governing rule s & standards in all respect and as per the approved scheme and guidance/direction ofEngineer - in - Charge. i) The offer shall be inclusive of supply of nitrogen, pig train, all consumables, taxes, duties as applicable and excluding GST. ii) IOCL\"s responsibility shall be limited to arrangement of a) Fire tender b) Ambulance c) Water supply d) Providing LPG in tanker truck and subsequently lining up of the pipeline system for LPG line fill.\"
458.625\"
46#Design, detailed engineering & installation of pipeline / pipeline & OFC conduit across rivers, NH, SH, Expressways, Railways, etc by HDD method. #Complete work for the crossing (between the limits, as indicated in the approved drawings) including mobilization & de-mobilization at site(s), supply of all materials as per the `Scope of Supply\" and all consumables, equipment, manpower & other re sources and arranging the required land for site preparations and execution of, but not limited to, the following works in accordanc e with the specifications, drawings and as per all provisions of the contract document and instructions of the Owner. #Interpretatio n of data of hydrological / geo-technical surveys furnished by the Owner, carrying out fresh topographic survey of the rivers, NH, S H, Expressways, Railways, etc & developing new profile drawing for the crossing location, carrying out additional surveys required f or collecting data relevant to design and construction of the crossing, performing all engineering & design calculations, preparatio n of all necessary construction drawings for approval of the Owner as per the provisions of contract document, preparation of detail ed construction method statement and design analysis. #Taking delivery and transportation of Owner-supplied 3LPE coated pipes to thework site from designated stockpile location, inspection of the coated pipes visually and/or with holiday detector for defects, inc luding arranging all necessary intermediate storage area required thereof till the pipes are installed in permanent position. #Compl ete site preparation including arranging of required land, setting up of fabrication yard, preparation of temporary arrangement for pipeline stringing, launching etc. #Carrying out repair of pipe defects, replacement in the case of non-repairable defects and repai ring damages to pipe coating including defects/ damages occurring during transportation and handling. #Pre-construction surveys and collection of all necessary data. #String preparation including repair of pipe and pipe coating defects, welding, non-destructive te sting of welds including 100% radiography (by X-ray), supply of films & all equipment and providing all facilities to Owner\"s repres entative(s) for examining radiographs, repair of defects in the.........Continued
47\"....in Continuation of previous.......welds and re-testing etc. #Coating of the field joints of the pipe string to be installed by HDD method with DIRAX heat shrink sleeves of M/s Raychem\"s make, DDXTM Directional Drilling Kit of M/s Canusa or of any other approv ed make used for HDD crossings. #Repair of all coating damages in the pipe section to be laid by HDD method by full encirclement sle eves using suitable cut sections of approved quality of heat shrink sleeves of M/s Raychem make, DDXTM Directional Drilling Kit of M /s Canusa or of any other approved make. #Fabrication of 89mm OD steel conduit with an inner duct of 40mm OD HDPE pipe for OFC (wher ever OFC has to be laid along with the carrier pipeline). #Supply & fixing of easy to install heat shrinkable duct end caps for HDPEconduit for OFC (wherever OFC has to be laid along with the carrier pipeline). #Carrying out air cleaning, gauge pigging and pre-in stallation hydrostatic testing of the complete pipeline string, as per the specifications, including repair of defects and retestingetc. #Installation of the pipeline / pipeline and OFC conduit as a bundle crossing below the rivers, NH, SH, Expressways, Railways,etc by single horizontal directional drilling operation to the correct profile as per the approved drawings. #Carrying out post-ins tallation hydrostatic testing of HDD pipe string (along with transition pipe section). #Carrying out post-installation coating surve y as per approved procedure. #Restoration, clean-up and disposal of drilling fluid, waste and all other surplus materials etc. #Tran sportation of surplus Owner-supplied pipes to the designated stockpile location of the Owner. #Preparation of as-built drawings and other records etc. #All other works not specifically listed herein, but required as per specifications, drawings, provisions of the contract document, calculations and construction method statement, leading to successful completion of the works. Note:-The Contractor shall have the option for installation of 89 mm OFC conduit as Bundled HDD installation along with the HDD inst allation of carrier pipe OR as a separate HDD instalation. However, the payment and payment terms shall remain the same in both the cases.\"
48UPTO 100 METERS (with OFC conduit)
498.625\" in Normal Soil
508.625\" in Rocky Soil
51101 - 300 METERS (with OFC conduit)
528.625\" in Normal Soil
538.625\" in Rocky Soil
54301 - 500 METERS (with OFC conduit)
558.625\" in Normal Soil
568.625\" in Rocky Soil
578.625\" in Normal Soil
588.625\" in Rocky Soil
59#Laying of Owner-supplied pre-coated mild steel line pipes, including arranging all additional land/construction corridor, beyond Ow ner\"s ROW, required for Contractor\"s storage, fabrication, access for construction site, movement of construction equipment etc., re ceiving and taking over Owner-supplied materials, handling, transportation etc. from Owner\"s issue point to work site, stringing alo ng Right of Way (ROW)/ pipeline corridor, providing labour, equipment and supply of other inputs & materials/ consumables necessary to perform and complete the work in all respects in accordance with the contract including, but not limited to, the following works: #Taking delivery and transportation of Owner-supplied coated pipes to the work site from designated Stockpile location, inspection o f the coated pipes visually and with holiday detector for defects, arranging all necessary intermediate storage area required thereo f till the pipes are installed in permanent position;#Clearing and grading of ROW/ pipeline corridor, cutting of trees, vegetation e tc. including keeping record of trees cut, including de-watering etc.;#Stringing of pipes along ROW including providing straw bags/ soft padding below pipe;#Trenching to all depths to maintain clear earth cover as per specification and to fit minimum bend radius, by excavation in all kinds of terrain & soil, including stripping top soil to a depth of 30cm to the full anticipated width of the d itch and storing this material separately along the ROW to allow re-depositing of the same on top of the backfilled ditch (in cultiv able and other areas specially designated by Owner);#Carrying out repair of pipe & coating defects for defects occurring after \"taki ng over\" of pipes from Owner, replacement in the case of non-repairable defects and repairing damages to pipe coating including defe cts/ damages occurring during transportation & handling;#Carrying out 100% radiographic inspection (by X-Ray) of all field weld join ts as per Specifications and Special Conditions of Contract (SCC) and destructive testing of one weld joint as per specification anddirection of Site Engineer, including providing Crawler type Automatic X-Ray machine and/ or external X-Ray machine and all other r equisite equipment, labour, supervision, materials, approved films, approved consumables, all facilities and personnel to process, d evelop, examine and interpret radiographs (by qualified and experienced Radiography Inspector), providing all facilities to Owner\"s representative(s) for examining radiographs and other tests as required, carrying out repair of weld-joints found defective, carryin g out re-radiography and other tests as required on repaired joints, etc.;#Carrying out coating of all field weld joints, by specifi ed coating insulators, including supply of approved joint coating materials, providing all equipment, materials and consumables nece ssary to carry out the job as per manufacturer\"s recommendation;#Carrying out holiday detection at specified voltage level correspon ding .......Continued
60\".....in Continuation of previous.... to coating type as per specifications, and repair of coating, if any;#Laying pipeline by open- cut method at crossings viz., cart-track, village road, metalled/ un-metalled roads, minor water courses (MWC) and restoration of th e site to original condition;#Lowering the pipeline in trench, tieing-in, backfilling with excavated earth and/or other suitable soi l (top soil stored separately during trenching shall be backfilled on top of the ditch) as directed by Site-Engineer;#Carrying out a ir cleaning, gauge pigging and hydrostatic testing (to specified pressure) of the complete pipeline including providing pre-testing of designated sections as approved by Engineer-in-Charge, providing all equipment, pumps, fittings, instruments, dead weight tester etc. and services, supervision, labour, consumables, testing of water, supply & injection of corrosion inhibitor, locating leaks, ifany, and rectification of defects attributable to Contractor, re-testing after rectification etc. and cleaning the pipeline sectionafter successful hydrotesting;#All tie-ins, including tieing-in with HDD section;#Obtaining work permits/ NOC from various authorit ies, having jurisdiction, before execution of work and complying with all stipulations/ conditions/ recommendation of the authoritie s;#Final clean-up and restoration of ROW/ construction corridor, field bunds etc. and obtaining NOC from statutory authorities (as r equired), and obtaining NOC from respective landowners in respect of final restoration of their land etc., disposal of debris and re turning surplus material to designated disposal areas/ storage location, as directed by Engineer-in-Charge, restoration of land, fac ilities and boundary wall etc. for facilities dismantled/ damaged by Contractor during construction;#Preparation of As-Built drawing s, Pipe book and other records as per specifications etc.;#Supply of all materials (other than those specifically undertaken to be s upplied by the Owner under the contract);#All other acts, deeds, matters and things necessary to make the pipeline ready for commiss ioning and completing the works in all respects as per drawings, specifications and instructions of Site Engineer/ Engineer-in-Charg e. Note: Liability of Owner to provide ROW to contractor shall be limited to the extent between the hook-up points with existing pipeli ne including for laying transition pipeline section. Additional space required by contractor beyond the above limits, including for access to site, shall be arranged by contractor at his own cost & initiative. Payment under this item shall be made only for the tra nsition pipe laid more than 12 m length on both sides. Transition Pipe laying upto 12 m length on both sides is included in the SOR item for Tie-In and Hook up.\"
61DIAMETER
628.625\"
63Civil Non ITC
64EARTHWORK :
65Earth work in surface excavation (not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan) in all kinds of soil including getting out and disposal of excavated earth up to all lead and lift, as directed by the Engineer-in-Charge.
66Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in widt h as well as 10 sqm on plan) including getting out and disposal of excavated earth, all works up to any lead and lift, as directed b y the Engineer-in-Charge :
67In all kinds of soil
68Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms including getting out the excavated soil and disp osal of surplus excavated soil, all works up to any lead and lift, as directed by the Engineer-in-Charge :
69In all kinds of soil
70Extra rates for quantities of works, executed in difficult conditions as per following: [Note: The extra percentage rate is applicab le in respect of each item but limited to quantities of work executed in these difficult conditions. The unit, namely, metre depth, to be considered for payment, shall be the depth measured from the sub soil water level upto the centre of gravity of the quantity e xecuted in difficult conditions. The depth shall be reckoned correct to 0.1 metre. 0.05 metre or more shall be taken as 0.1 metre an d less than 0.05 metre ignored.] :
71Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in d epth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5m.
72Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
73Supplying chemical emulsion (Chlorpyriphos/ Lindane emulsifiable concentrate of 20%) in sealed containers including delivery as spec ified.
74Diluting and injecting chemical emulsion (Chlorpyriphos/ Lindane E.C. 20% with 1% concentration) for POST-CONSTRUCTIONAL anti-termit e treatment (excluding the cost of chemical emulsion) :
75Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres/ sqm of the vertical surface of the substru cture to a depth of 300 mm including excavation channel along the wall & rodding etc. complete :
76\"Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diamete r holes and plugging with cement mortar 1 : 2 (1 cement : 2 Coarse sand) to match the existing floor : \"
77Treatment of existing masonry using chemical emulsion @ 1 litre per hole at 300 mm interval including drilling holes at 45 degree an d plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole :
78Filling the excavated earth to required grade, level & profile in low lying areas including watering, ramming, compacting at optimummoisture content to 90% of Proctor\"s density consolidation by rolling with 8 to 10 tonne power rollerin layers not exceeding 20 c m thickness, including clearing the area by cutting of shrubs, bushes, grass, vegetation, debris etc. stacking and disposing out of plot area to an unobjectional area as directed by Engineer-in-Chargecomplete in all respects inclusive of cost of all labour, mate rials, tools, tackles etc. as per drawings, specifications and direction of the Engineer-in-Charge.
79Supplying and filling selected earth/ moorum (excluding black cotton soil) from Contractor\"s own borrow areas including royalty, wit h all leads and lifts in low laying areas and filling to required grade and level including watering, compacting at optimum moisturecontent to 90% of Proctor\"s density, consolidation androlling with 8 to 10 tonne power rollerin layers not exceeding 20 cm thic kness, complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.
80CONCRETE WORK :
81Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
821:1.5:3 [1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived fr om natural sources]
831:2:4 [1 cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from n atural sources]
841:3:6 [1 cement : 3 coarse sand (Zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from n atural sources]
851:4:8 [1 cement : 4 coarse sand (Zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from n atural sources]
86Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in p osition with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete :
87Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 [1 cement : 2 coarse sand (Zone-III) derived from natu ral sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources]
88Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 Kg per square metre on dam p proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
89Making plinth protection 50 mm thick of cement concrete 1:3:6 [1 cement : 3 coarse sand derived from natural sources : 6 graded ston e aggregate 20 mm nominal size derived from natural sources] over 75 mm thick bed of dry brick ballast 40 mm nominal size, well ramm ed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth, etc . complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direc tions of the Engineer-in-Charge.
90REINFORCED CEMENT CONCRETE :
91Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishi ng and reinforcement - All work up to plinth level :
921:1.5:3 [1 cement : 1.5 coarse sand (Zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived fr om natural sources]
931:2:4 [1 cement : 2 coarse sand derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sour ces]
94Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fille ts, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering , shuttering, finishing and reinforcement, with :
951:1.5:3 [1 cement : 1.5 coarse sand (Zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived fr om natural sources]
96Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 Degree landings, balconies, shelves, chajjas , lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cos t of centering, shuttering, finishing and reinforcement, with :
971:1.5:3 [1 cement : 1.5 coarse sand (Zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived fr om natural sources]
98Centering and shuttering including strutting, propping etc. and removal of form for all heights :
99Foundations, footings, bases of columns, etc. for mass concrete
100Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
101Suspended floors, roofs, landings, balconies and access platform
102Lintels, beams, plinth beams, girders, bressumers and cantilevers
103Columns, Pillars, Piers, Abutments, Posts and Struts
104Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto pli nth level :
105Thermo-Mechanically Treated bars of grade Fe-500D or more
106Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above pl inth level :
107Thermo-Mechanically Treated bars of grade Fe-500 D or more
108Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using coarse aggregate as wellas fine aggregate derived from natural sources and cement content as per approved design mix, manufactured in fully automatic batch ing plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , ex cluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as pe r IS:9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per directionsof the Engineer-in-Charge. [Note : Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design m ix is payable/ recoverable separately] :
109All works upto plinth level
110All works above plinth level upto floor V level
111Supplying and providing non-shrinkable cement grout (SHRINKKOMP 20 or any other equivalent approved brand) for grouting holding downbolts in pocket holes for equipment foundation, including necessary surface preparation mixing of grout, curing as per manufacturer \"s recommendation/ specification and directions of the Engineer-in-Charge. [Note: This item shall be operated under specific instruc tions of the Engineer-in-Charge]
112MASONRY WORK :
113Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in :
114Cement mortar 1:4 (1 cement : 4 coarse sand)
115Cement mortar 1:6 (1 cement : 6 coarse sand)
116Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to fl oor V level in all shapes and sizes in :
117Cement mortar 1:6 (1 cement : 6 coarse sand)
118CLADDING WORK :
119Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut Granite (of any colour and s hade) for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour an d texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matc hing pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete atall levels :
120Area of slab up to 0.50 sqm
121Providing and laying Burnt Terracota Tiles 12 mm thick for facia, over walls, sloping RCC Roofs etc. at all levels and locations lai d over and including a backing coat of 15 mm thick cement mortar (1 cement : 3 sand) and joints filled with coloured cement of same colour as tiles complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per specifications and d irections of the Engineer-in-Charge.
122Providing and fixing 12 mm thick Elevational Brick Tiles for facia, vertical face of walls, etc. at all levels and locations laid ov er and including a backing coat of 15 mm thick cement mortar (1 cement : 3 sand) and joints filled with coloured cement of same colo ur as tiles complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per specification and direct ions of the Engineer-in-Charge.
123Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part I) decorative type, core of block board constructionwith frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on bot h faces of shutters :
12435 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
125STEEL WORK :
126Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing i n position and applying a priming coat of approved steel primer all complete.
127Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrange ments for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27. 5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS:4454 (Part-1) and M.S. top co ver of required thickness for rolling shutters :
12880 x 1.25 mm M.S. laths with 1.25 mm thick top cover
129Providing and fixing ball bearing for rolling shutters.
130Supplying and fixing circular/ hexagonal M.S. Sheet ceiling fan box with clamp, 140 mm internal diameter, 73 mm height, 3 mm thick r im bottom, and top lid of 1.5 mm thick, M.S. sheet lids shall be screwed into the M.S. box by means of 3.0 mm diameter round headed screws, clamp shall be made of 12 mm diameter M.S. bar bent to shape as per standard drawings with over all length as 80 cm completein all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of t he Engineer-in-Charge.
131Supplying, fabricating, erecting, placing and fixing in position M.S. structural works using rolled/ built up sections for truss, cl addings, bracings, purlins, supporting frames made of joists, tubes, pipes, channels, angles, plates, flats, bars etc. including cut ting to required size welding of joints, fixing anchor plates, including bolts, theading, nuts, washers, sleeves etc. includingpre paration of detailed fabrication drawings & submission to the Engineer-in-Charge for approval before start of fabrication, supplying& applying painting with two coats of epoxy paint \"EPILUX 155 High Build Enamel over a coat of \"EPILUX 610\" Primer of M/s BERGER orany other approved equivalent make as per manufacturer’s recommendation, complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. (Excluding the cost of conc rete work).
132Supplying, fitting and fixing hot dip galvinised barbed line wire through holes in fencing posts (already made in the body of the po st), tightening and fixing the wire in tight condition with straining bolts (straining bolts at end post) including the cost of cutt ing and lapping joints, making holes, straining bolts, galvanised staples, binding wires etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.
133Supplying & fixing welded steel wire fabric of rectangular mesh 75 x 25 mm size, weight not less than 7.75 Kg/sqm fixed on angle iro n frame by welding, painted with two coats of synthetic enamel paint of over a coat of red oxide zinc chrome primer complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engin eer-in-Charge. [Note: This item is for openings in DG, Compresoor, Transformer/ VCB Room/ AVR Room. Angle iron frame shall be paid s eparately].
134Supplying and placing in position 5.0 mm thick steel chequered plates over cable ducts, valve pits etc. including provision for lift ing arrangements complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifica tions and directions of the Engineer-in-Charge.
135Supplying, fitting and fixing punched tape concertina spiral coil of 50 turns per coil having core wire of 2.6 mm diameter made of h igh carbon spring steel of high tensile strength as per IS:4454 (Part-I, Grade-II) having minimum galvanising coating thickness equi valent to 230 grams per square metre and low carbon steel strip of 0.5 mm thickness having a series of barbes punched all along the length on both sides of the strip at regular interval as per IS:513, DD quality having minimum galvanising coating thickness of 12 m icrons. Hardness of tape should be between 137-180 VPN (Victor Penetration Number). The coil should be clipped sufficiently at regul ar intervals. The coil should not be stretched for more than 6.0 m length and the minimum diameter of the coil in the closed conditi on should not be less than 600 mm complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per dr awings, specifications and directions of the Engineer-in-Charge.
136FLOORING :
137Supplying and laying flat brick soling in foundation trench, in floors, garages, sumps, etc., with bricks of class designation 50 la id to proper slope, level and grade etc. filling of the joints with sand etc. complete in all respects inclusive of cost of all labo ur, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.
138Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1: 2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting ofmix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 k g of cement or as per manufacturer\"s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
139Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make & colour using acid and/or alkali resisting mor tar bedding and filling joints with acid and/or alkali resisting cement as per IS:4457, all complete as per specifcations and direct ions of the Engineer-in-Charge :
140In flooring on a bed of 10 mm thick mortar 1:4 (1 acid and/or alkali resistant cement : 4 coarse sand) :
141In dado/ skirting on 12 mm thick mortar 1:4 (1 acid and/or alkali resistant cement : 4 coarse sand) :
142Providing and laying Polished Granite stone slab (Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent) flooring in required de sign and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 1 8 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. al l complete as specified and as directed by the Engineer-in-Charge.
143Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cemen t: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and poli shing complete.
144Providing and fixing ceramic glazed floor tiles of first quality conforming to IS:15622 (thickness to be specified by the manufactur er) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by the Engineer-in-Charge i n skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cem ent slurry @ 3.3 Kg/sq.m. including pointing in white cement mixed with pigment of matching shade complete.
145Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of first qualityconforming to IS:15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick be d of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 Kg/sq.m. including pointing the joints wit h white cement and matching pigments etc., complete.
146Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the Manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 ce ment : 4 coarse sand), jointing with grey cement slurry @ 3.3 Kg/sq.m. including grouting the joints with white cement and matching pigments etc., complete :
147Size of Tile 600x600 mm
148Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absor ption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement basedhigh polymer modified quick set tile adhesive (water based) conforming to IS:15477, in average 6 mm thickness, including grouting o f joints. [Note: Payment for grouting of joints shall be made separately] :
149Size of Tile 600x600 mm
150Providing and fixing removable raised/ false access flooring with system (Unitile Solid Feel (USF) 800 or equivalent) and its compon ents of approved make for different plenum height with possible height adjustment up to 50 mm, comprising of modular load bearing fl oor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of: (A) Providing at required spacing to form modular framework, pedes tals made out of G.I. tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75 mm x 75 mm x 3.5 mm welded with G.I. fully threaded stud 16 mm outer diameter with two G.I. Check nuts screwed on the stud for level adjustment up to 50 mm, locking and stabilizing thepedestal head in position at the required level. The pedestals shall be fixed to the sub-floor (base) through base plate using epox y based adhesive of approved make or the machine screw with rawl plug. (B) Stringers system in all steel construction hot dipped gal vanized of rectangular size 570x20x30x0.80 mm thick having holes at both ends for securing the stringers on to the pedestal head usi ng fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assemblyshall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel. The system shall pro vide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete asper the architectural drawings, as specified and as directed by the Engineer-in-Charge. (C) Providing and fixing Access Floor panelof 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall besteel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Gauges: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange) . The panel should be corrosion resistant epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate isfilled with Pyrogrip non-combustible Portland cementitious core mixed with lightweight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology up to 1 mm thickness for superior adhesion and Sur face flatness within 0.75 mm.The panel is to withstand a Concentrated Load of 363 Kg applied on area 25 mm x 25 mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minim um 1250 Kg/sq.m. and, an impact load of 50 Kg all complete as per the approved manufacturers specification and as per the direction of the Engineer-in-Charge. All specification must be printed on the side of the panel to ensure the quality of the product :
151Providing and fixing 2 mm thick P.V.C. (BHOR or equivalent make) sheet/ tile flooring on a smooth and damp proof base using rubber b ased adhesives includingrolling with light wooden roller weighing about 5 Kg, all complete including cost of preparation of subgra de, damp proof course consisting of 30 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm n ominal size) as directed by the Engineer-in-Charge.
152ROOFING & CEILING :
153Providing gola 75x75 mm (in 75x75 mm deep chase) in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and do wn gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design.
154Making Khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggr egate of 20 mm nominal size) over P.V.C. sheet 1 m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse s and) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
155Providing and fixing on wall face Unplasticised Rigid PVC (uPVC) rainwater pipes (110 mm diameter, single socketed) conforming to IS :13592 Type-A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion.
156Providing and fixing on wall face Unplasticised-PVC (UPVC) moulded fittings/ accessories for Un-plasticised Rigid PVC rainwater pipe s conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion :
157Coupler (110 mm)
158Single Push-fit Coupler (110 mm)
159Bend- 87.5 Degrees (110 mm)
160Shoe - Plain (110 mm)
161Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of a pproved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 82 25:1987, Non-combustible as per BS 476:1970 (Part-4) and Light Reflectance of 85% (minimum) to be laid in true horizontal level susp ended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick (galvanized @ 120 grams per sqm includingboth sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross-T of size 15x32 mm of length 1200 mm andsecond ary intermediate cross-T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm, suspended from ceiling using galv anised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully thr eaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24 x24x0.40 mm of length 3000 mm to be fixed on periphery wall/ partition with the help of plastic rawl plugs at 450 mm center to cente r and 40 mm long dry wall SS screws. The work shall be carried out as per specifications, drawing and as per directions of the Engin eer-in-Charge :
162With semi-perforated 12 mm thick micro tegular edged GRG false ceiling tiles.
16315 mm cement plaster on the rough side of single or half brick wall of mix :
1641:6 (1 cement : 6 fine sand)
16515 mm cement plaster on rough side of single or half brick wall of mix :
1661:6 (1 cement : 6 coarse sand)
1676 mm cement plaster of mix 1:3 (1 cement : 3 fine sand)
1686 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams.
169Neat cement punning.
170Providing & fixing galvanized chicken wire net 20 Gauge, 20 mm mesh size in plastering work at the junction of RCC Columns/ Beams & brickwork as directed by the Engineer-in-Charge.
171Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
172Water thinnable cement primer
173Finishing walls with water proofing cement paint of required shade :
174New work (Two or more coats applied @ 3.84 Kg/10 sqm)
175Finishing walls with textured exterior paint of required shade :
176New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
177Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
178Two or more coats on new work
179Polishing on wood work with ready mixed wax polish of approved brand and manufacture :
180Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wa ll surface to prepare the surface even and smooth complete.
181Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 gra ms/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour :
182Two coats
183Providing & fixing white vitreous china water closet squatting pan (Indian type) along with \"S\" or \"P\" trap including dismantling ofold WC seat and \"S\" or \"P\" trap at site complete with all operations including all necessary materials, labour and disposal of dism antled material including malba, all complete as per the directions of Engineer-in-Charge :
184Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, blac k finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of me mbrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemi cal parameters of the membrane shall be as under : (a) Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5 cm. (b) Tear strength in longitudinal and transverse direction as 300/250N. (c) Softening point of membrane not less than 150°C. (d)Cold flexibility shall be up to -2°C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane.
185Extra for covering top of membrane with Geotextile, 120 GSM non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membra ne with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation.
186ROAD WORK :
187Preparation and consolidation of sub-grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the s ub grade and disposal of surplus earth with lead up to 50 metres.
188Supplying and stacking at site :
18990 mm to 45 mm size stone aggregate
190Stone screening 13.2 mm nominal size (Type A)
191Moorum
192Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rollin g with 3 wheeled road/ vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite ty pe of screening/ binding material to fill up interstices of coarse aggregate, watering and compacting to the required density.
193Surface dressing on new surface with paving bitumen of grade VG-10 of approved quality using 2.25 Kg of bitumen per sqm with 1.65 cu m of stone chippings 13.2 mm nominal size per 100 sqm of road surface, including consolidation with road roller of 6 to 8 tonne capa city etc. complete.
194Providing and laying design mix reinforced cement concrete of M-30 grade in roads/ taxi tracks/ runways, using cement content as perdesign mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specifi ed design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading, levelling to required s lope/ camber and compacting mechanically by using screed board vibrators, vaccum dewatering process and finally finishing in require d texture by floating & brooming with wire brush, including steel form work with sturdy M.S. channel sections, curing, making provis ion for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing ex pansion joints as per drawing including dowel cap, sponge, sealing tape, bitumen painting, debonding tape and filling joints with ap proved joint filler and sealants, complete all as per direction of the Engineer-in-Charge. [Notes: (1) Item of joint fillers, sealan ts, dowel bars with sleeve/ tie bars to be paid separately. (2) The item rate is inclusive of cost of dowel cap, sponge, sealing tap e, bitumen painting, debonding tape. (3) Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design m ix is payable/ recoverable separately].
195Cement concrete manufactured in automatic batching plant (RMC plant) including transportation to site in transit mixer
196Providing and fixing in position pre-moulded joint filler in expansion joints. [Note: Unit \"CM\" shall mean \"PER CENTIMETRE DEPTH PERCENTIMETRE WIDTH PER METRE LENGTH\"].
197Providing and laying in position bitumen hot sealing compound for expansion joints etc. :
198Using Grade \"A\" sealing compound. [Note: Unit \"CM\" shall mean \"PER CENTIMETRE DEPTH PER CENTIMETRE WIDTH PER METRE LENGTH\"].
199Painting road surface marking with adequate nos of coats to give uniform finish with ready mixed road marking paint conforming to IS :164, on bituminous surface in white/ yellow shade, including cleaning the surface of all dirt, scales, oil, grease and foreign mate rial etc. complete :
200New work (Two or more coats)
201Supplying and fixing Road Hump of minimum size 350 mm width x 50 mm thick made of Carbon Black mixed Rubber with Additive of LDPE fo r reinforcement & UV resistant colouring agent of black & yellow colour with 4 reflective glass beads, of weight not less than 16 Kg /metre, and capacity to withstand minimum 35 tonne weight (moving vehicle load) including cleaning the road surface of all dirt, sca les, oil, grease and foreign material etc. and fixing the hump on the Road top as per manufactures specifications with necessary fas teners complete in all respects inclusive of cost of all labour, materials, fasteners, tools, tackles etc. as per specification and directions of the Engineer-in-Charge.
202Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fullycovered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to Type-III of ASTM-D-49 56-01 as approved by the Engineer-in-Charge, letters, borders etc. as per IRC:67:2001 in silver white with blue colour back ground a nd with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressu re conforming to Class-II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized alu minium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with t heft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of alu minium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structura l frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and directions ofthe Engineer-in-Charge. [Note: Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment] :
203Providing and applying 2.5 mm thick road marking strips (retro-reflective) of specified shade/ colour using hot thermoplastic materi al by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank hea ter and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the ro ad surface of all dirt, seals, oil, grease and foreign material etc. complete as per directions of the Engineer-in-Charge and accord ance with applicable specifications.
204Providing and laying factory made chamfered edge interlocking Cement Concrete paver blocks in foot path, park & lawns driveway or li ght & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in req uired colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver b locks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer\"s specifications & directions of the Engineer-in-Charge :
20580mm thick Cement Concrete paver block of M-30 grade with approved colour, design & pattern.
206Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line,level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thi ckness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc . as per directions of the Engineer-in-Charge. [Notes: (1) Length of finished kerb edging shall be measured for payment. (2) PrecastC.C. kerb stones shall be approved by the Engineer-in-Charge.]
207SANITARY INSTALLATIONS :
208Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS:7231, with allfittings and fixtures complete, including cutting and making good the walls and floors wherever required :
209W.C. pan with ISI marked white solid plastic seat and lid.
210Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I cl amps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
211One urinal basin with 5 litre white P.V.C. automatic flushing cistern
212Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, includ ing painting of fittings and brackets, cutting and making good the walls wherever require :
213White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap
214Flexible Pipe :
21532 mm diameter
216Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board grou nd fixed to wooden cleats with C.P. brass screws and washers complete.
217Providing and fixing toilet paper holder :
218C.P. Brass (Ref. Make: JAQUAR, Model: Cat. No.-1151 or approved equivalent).
219Re-painting sand cast iron/ centrifugally cast iron (spun) iron, soil, waste, vent pipes and fittings with one coat of synthetic ena mel paint of any colour such as chocolate, grey or buff, etc. :
22075 mm diameter pipe
221Providing and fixing the following washroom fittings, complete in all respects; inclusive of cost of all materials, labour, tools, t ackles etc. as per specifications and directions of the Engineer-in-Charge :
222Stainless steel liquid soap container (spring loaded push type) with lid and brackets fixed to P.V.C. cleats with C.P. brass screws,etc.
223C.P. brass double coat hook (Ref. Make: JAQUAR, Model: Cat. No. 1161 or approved equivalent).
224WATER SUPPLY :
225Internal Work - Exposed on wall: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. Th is includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per directions of the E ngineer-in-Charge :
22615 mm nominal outer dia pipes
22720 mm nominal outer dia pipes
22825 mm nominal outer dia pipes
22932 mm nominal outer dia pipes
230Internal Work - Concealed in wall: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for ho t & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This i ncludes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same inclu ding testing of joints complete as per directions of the Engineer-in-Charge :
23115 mm nominal dia pipes
23220 mm nominal dia pipes
233Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
23425 mm nominal bore
23532 mm nominal bore
236Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms:
23715 mm nominal bore
238Providing and fixing 15mm diameter C.P. brass tap as per following with C.P. brass flange including cutting & making good the walls wherever required, etc. complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specificatio ns and directions of the Engineer-in-Charge :
239Bib Cock (Ref. Make: JAQUAR, Model: Cat. No. 0021 or approved equivelent)
240Providing and fixing 15mm diameter C.P. brass angle valve as per following with C.P. copper connecting pipe 375mm long or as require d including nuts, washers, C.P. brass flange, etc. including cutting & making good the walls wherever required, etc. complete in allrespects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Ch arge :
241Angle Valve (Ref. Make: JAQUAR, Model: Cat. No. 0053 or approved equivalent)
242Providing and fixing 15mm diameter C.P. brass stop cock with wall flange (Ref. Make: JAQUAR, Model: Cat. No. 0933 or approved equiva lent), male end with C.P. copper connecting pipe 375mm long or as required including nuts, washers, C.P. brass flange etc. includingcutting & making good the walls wherever required complete in all respects inclusive of cost of all materials, labour, tools, tackl es etc. as per specifications and directions of the Engineer-in-Charge.
243Providing & fixing Angle Valve(Ref. Make: JAQUAR, Model: Cat. No. 563 or approved equivalent) and Health Faucet with flexible tube8mm diameter x 1.5 m long (Ref. Make: JAQUAR, Model: Cat. No. 549 or approved equivalent).
244Providing and fixing rectangular high density polyethylene water storage loft tank with cover (Ref. Make: SINTEX or approved equival ent), conforming to ISI:12701, colour of opaque white or as approved by the Engineer-in-Charge. The rate includes making necessary h oles for inlet, outlet & overflow pipes. The base support including fittings & fixtures for tank shall be paid separately.
245DRAINAGE :
246Providing, laying and jointing glazed stoneware pipes Class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cem ent : 1 fine sand) including testing of joints etc. complete :
247150 mm diameter
248200 mm diameter
249250 mm diameter
250Providing and fixing square mouth S.W. gully trap class SP-1 complete with C.I. grating, brick masonry chamber with water tight C.I.cover with frame of 300x300 mm size (inside dimension). The brick masonary chamber shall be constructed with common burnt clay F.P. S. (Non-modular) bricks of class designation 7.5. [Note: Weight of the cover shall not less than 4.50 kg and weight of the frame sha ll not be less than 2.70 kg as per standard design] :
251100x100 mm size P-type
252Providing and laying non-pressure NP-2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in t he proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
253250 mm dia. R.C.C. pipe
254300 mm dia. R.C.C. pipe
255450 mm dia. R.C.C. pipe
256Providing and laying Non Pressure NP-4 class (Heavy duty) R.C.C. pipes including collars/ spigot jointed with stiff mixture of cemen t mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
257450 mm dia R.C.C. pipes
258Constructing brick masonry chamber for underground C.I. inspection chamber and bends with common burnt clay F.P.S. (Non-modular) bri cks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 Kg and weight of frame 15 Kg), R.C.C. topslab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cemen t : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :
259Inside dimensions 455x610 mm and 45 cm deep for single pipeline :
260Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diam eter, 1.8 m long complete as per standard design :
261With common burnt clay F.P.S. (Non-modular) bricks of class designation 7.5
262Constructing brick masonry Septic Tank with brickwork in cement mortar 1:6 including R.C.C. 1:2:4 (1 cement : 2 sand : 4 graded coar se aggregate) top slab, C.I. cover all as per standard drawing, etc. complete in all respects inclusive of cost of all materials, la bour, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge :
263For 10 Users
264Constructing percolation pit of size 3.0m diameter and 2.0m deep, filled with 40 mm size brick ballast including providing suitable pre-cast RCC covers with lifting lugs, laying of 150mm diameter x 5.0m long U.P.V.C. pipe embedded in pit/ outlet pipe all complete as per specification and directions of the Engineer-in-Charge.
265Providing and fixing self cleaning S.C.I. heavy quality Floor/ Nahani trap with 100mm diameter inlet and 100mm diameter outlet, 125m m C.P. brass grating (heavy type) with or without vent arm including cost of cutting and making good the walls and floors, jointing with lead caulked joints, connecting with waste water pipe etc. complete in all respects inclusive of cost of all materials, labour,tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.
266Providing and fixing 32mm diameter (Nominal Bore) brass ball valve of approved quality complete with high pressure copper floats, co mplete in all respects inclusive of cost of all materials, labour, tools, tackles, etc. complete as per specifications and direction s of the Engineer-in-Charge.
267Construction of second class brick masonary open surface drain (Size: 200mm wide & 200mm average depth) in cement mortar 1:4 laid ov er a bed of 150mm thick cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including mak ing haunches and providing 15mm thick cement plaster in CM 1:4 (1 cement : 4 coarse sand) with a floating coat of neat cement insideand its top and exposed surfaces, including excavatioin, disposal of the surplus earth up to any lead and lift as per standard desi gn and drawing, complete in all respects inclusive of cost of all labour, materials, carriages, excavation and refilling, curing etc ., as per specifications and directions of the Engineer-in-Charge.
268Constructing Brick Masonary catch pit in cement mortar 1:4 (1 cement : 4 coarse sand) including necessary excavation, 200mm thick fo undation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm size) and inside and top plastering (15mm thic k) with cement mortar 1:4 (1 cement : 4 coarse sand) finished with a floating coat of neat cement making necessary connections to dr ains inclusive ofall labour, material, equipment, etc., all complete as per drawing, specifications and directions of the Engineer -in-Charge :
2691000mm x 1000mm x depth up to 1200mm inner dimensions.
270750mm x 750mm x depth up to 1000mm inner dimensions
271600mm x 600mm x depth up to 750mm inner dimensions
272PILE WORK :
273Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and lengt h below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the le ngth of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads [No tes: (1) Length of pile for payment shall be measured up to bottom of pile cap. (2) Truck Mounted rotary/ TMR/ Tubewell boring machi ne shall not be used] :
274450 mm diameter piles
275Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified dia meter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost ofsteel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. [Note: Length of pile for payment shall be measured upto to the bottom of pile cap] :
276400 mm diameter piles
277Vertical load testing of piles in accordance with IS:2911 (Part-IV) including installation of loading platform by Kentledge/ Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per sp ecification & the direction of the Engineer-In-Charge. [Notes : (1) Initial and Routine Load Test shall not be carried out by Dynami c method of testing. (2) Testing agency shall submitt the design of loading platform for the approval of the Engineer-in-Charge.] :
278Single pile up to 50 tonne Safe Capacity :
279Initial Test (Test Load 2.5 times the Safe Capacity) [Note: Unit \"EA\" shall mean \"PER TEST\"]
280Routine Test (Test Load 1.5 times the Safe Capacity) [Note: Unit \"EA\" shall mean \"PER TEST\"]
281Group of two or more piles up to 50 tonne Safe Capacity :
282Initial Test (Test Load 2.5 times the Safe Capacity) [Note: Unit \"EA\" shall mean \"PER TEST\"]
283Routine Test (Test Load 1.5 times the Safe Capacity) [Note: Unit \"EA\" shall mean \"PER TEST\"]
284ALUMINIUM WORK :
285Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of requireddia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neopre ne gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural d rawings and the directions of the Engineer-in-Charge. [Note: Glazing, paneling and dash fasteners to be paid for separately] :
286For fixed portion :
287Powder coated aluminium (Minimum thickness of powder coating 50 micron)
288For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittin gs wherever required including the cost of EPDM rubber/ neoprene gasket required. [Note: Fittings shall be paid for separately] :
289Powder coated aluminium (Minimum thickness of powder coating 50 micron)
290Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket et c. complete as per the architectural drawings and directions of the Engineer-in-Charge. [Note: Cost of aluminium snap beading shall be paid in basic item] :
291With float glass panes of 5.50 mm thickness
292Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS:6315, having brand logoembossed on the body/ plate with double spring mechanism and door weight up to 125 Kg, for doors, including cost of cutting floors,embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivotand single piece M.S. sheet outer box with slide plate etc. complete as per directions of the Engineer-in-Charge. :
293With stainless steel cover plate minimum 1.25 mm thickness
294Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per d irections of the Engineer-in-Charge :
295Powder coated (Minimum thickness 50 micron) aluminium tubular handle bar
296Providing and fixing brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for al uminium doors including necessary cutting and making good etc. complete.
297Filling the gap in between Aluminium/ Stone/ Wood frame and adjacent RCC/ Brick/ Stone/ Wood/ Ceramic/ Gypsum work by providing weat her/ structural non-sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and directions of t he Engineer-in-Charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600 :
298Up to 5 mm depth and 5 mm width
299Up to 10 mm depth and 10 mm width
300Up to 20 mm depth and 20 mm width
301Providing and fixing, on fixed glazing/ doors/ window panes, sun control film \"HP NATURAL 35 SAFETY COMBINATION FILM-4Mil\" of M/s. G ARWARE or approved equivalent make and shade, all complete as per manufacturer\"s specification and as per directions of the Engineer -in-Charge.
302Grading roof for water proofing treatment with :
303Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
304Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflec tivity Index (SRI) of 105 on top of concrete roof in three coats @ 10.76 litre/10 sqm. One coat of self-priming of elastomeric water proofing liquid (dilution with water in the ratio of3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thi ckness of complete application/ system not less than 500 microns). The operation shall be carried out after scrapping and properly c leaning the surface to remove loose particles with wire brushes, complete in all respect as per directions of the Engineer-in-Charge .
305Supplying and using water proofing compound like CICO, PUDDLE or any other approved brand with Cement Plaster/ CC/ RCC complete in a ll respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the En gineer-in-Charge.
306Supplying, assembling, lowering and fixing in vertical position in bore well Un-plasticized P.V.C. medium well screen (RMS) pipes wi th ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per d irections of the Engineer-in-Charge :
307Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, forall leads & lifts, all complete as per directions of the Engineer-in-Charge.
308Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulde rs, in required thickness, for all leads & lifts, all complete as per directions of the Engineer-in-Charge.
309Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravellayer, for all leads & lifts, all complete as per directions of the Engineer-in-Charge.
310GENERAL WORKS :
311Providing and filling bituminastic compound in 50mm thick x 150mm deep grooves around foundations, in floors, pavements and expansio n joints, etc. complete as per directions of the Engineer-in-Charge.
312Providing and fixing 75mm diameter P.V.C. pipe (4 Kg/sq.cm) for Weep Holes in Masonry/ RCC wall including providing 230x230x230 mm s ize (approx.) filter using pebles of 40mm & down size in every weep hole on retaining side etc. complete in all respects inclusive o f cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge.
313HORTICULTURE & LANDSCAPING :
314Supplying and stacking of good earth at site including royalty and carriage up to any lead complete. [Note: Volume of earth measuredin stacks will be reduced by 20% for payment].
315Supplying and stacking sludge at site including royalty and carriage up to any lead complete. [Note: Volume of sludge measured in st acks will be reduced by 8% for payment].
316Supplying and stacking of well decayed cattle manure at site including royalty and carriage up to any lead complete. [Note: Volume o f cattle manure measured in stacks will reduced by 8% for payment].
317Supplying and stacking at site dump manure from approved source, including carriage up to any lead complete. [Note: Volume of manuremeasured in stacks will be reduced by 8% for payment] :
318Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm,refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, fillin g with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared u nserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete. [Note: Cost of sludge, manure or extra earth shall be paid for separately under relevant item of SOR].
319Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by vo lume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) floodingwith water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts. [Note: Cost of manure, sludg e or extra good earth if needed shall be paid separately under relevant item of SOR].
320Holes 1.2 m diameter and 1.2 m deep
321Holes 60 cm diameter and 60 cm deep
322Grassing with selection No. 1/ Doob grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supply and filling of good earth, if required during maintenance period. [N ote: The grass and good earth shall be paid for separately under relevant item of SOR] :
323In rows 5 cm apart in both directions
324Supply and planting sapling (not less than 45 cm in height and 60 cm centre to centre) of Casurina, Labrum, Gulmohar, Ashokas, Bottl e Palm, Bougenvilla, Hibiscus, Roses or other approved type of variety of plants, watering & maintenance for 30 days minimum complet e in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engine er-in-Charge.
325Civil ITC
326EARTHWORK :
327Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in widt h as well as 10 sqm on plan) including getting out and disposal of excavated earth, all works up to any lead and lift, as directed b y the Engineer-in-Charge :
328In all kinds of soil
329Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
330CONCRETE WORK :
331Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
3321:3:6 [1 cement : 3 coarse sand (Zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from n atural sources]
3331:4:8 [1 cement : 4 coarse sand (Zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from n atural sources]
334REINFORCED CEMENT CONCRETE :
335Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishi ng and reinforcement - All work up to plinth level :
3361:1.5:3 [1 cement : 1.5 coarse sand (Zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived fr om natural sources]
337Centering and shuttering including strutting, propping etc. and removal of form for all heights :
338Foundations, footings, bases of columns, etc. for mass concrete
339Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto pli nth level :
340Thermo-Mechanically Treated bars of grade Fe-500D or more
341Extra for providing richer mixes at all floor levels. [Note: Excess/ less cement over the specified cement content used is payable/ recoverable separately] :
342Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. [Note: Cement content considered in M-30 is @ 340 Kg/cum]
343Add for using extra cement in the items of design mix over and above the specified cement content therein. [Note: Unit \"QN\" shall me an \"QUINTAL\"]
344Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using coarse aggregate as wellas fine aggregate derived from natural sources and cement content as per approved design mix, manufactured in fully automatic batch ing plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , ex cluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as pe r IS:9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per directionsof the Engineer-in-Charge. [Note : Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design m ix is payable/ recoverable separately] :
345All works upto plinth level
346Supplying and providing non-shrinkable cement grout (SHRINKKOMP 20 or any other equivalent approved brand) for grouting holding downbolts in pocket holes for equipment foundation, including necessary surface preparation mixing of grout, curing as per manufacturer \"s recommendation/ specification and directions of the Engineer-in-Charge. [Note: This item shall be operated under specific instruc tions of the Engineer-in-Charge]
347MASONRY WORK :
348Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in :
349Cement mortar 1:4 (1 cement : 4 coarse sand)
350STEEL WORK :
351Supplying, fabricating, erecting, placing and fixing in position M.S. structural works using rolled/ built up sections for truss, cl addings, bracings, purlins, supporting frames made of joists, tubes, pipes, channels, angles, plates, flats, bars etc. including cut ting to required size welding of joints, fixing anchor plates, including bolts, theading, nuts, washers, sleeves etc. includingpre paration of detailed fabrication drawings & submission to the Engineer-in-Charge for approval before start of fabrication, supplying& applying painting with two coats of epoxy paint \"EPILUX 155 High Build Enamel over a coat of \"EPILUX 610\" Primer of M/s BERGER orany other approved equivalent make as per manufacturer’s recommendation, complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. (Excluding the cost of conc rete work).
352FLOORING :
353Supplying and laying flat brick soling in foundation trench, in floors, garages, sumps, etc., with bricks of class designation 50 la id to proper slope, level and grade etc. filling of the joints with sand etc. complete in all respects inclusive of cost of all labo ur, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.
354FINISHING :
35515 mm cement plaster on rough side of single or half brick wall of mix :
3561:6 (1 cement : 6 coarse sand)
3576 mm cement plaster of mix 1:3 (1 cement : 3 fine sand)
358Neat cement punning.
359GENERAL WORKS :
360Providing and filling bituminastic compound in 50mm thick x 150mm deep grooves around foundations, in floors, pavements and expansio n joints, etc. complete as per directions of the Engineer-in-Charge.
361Electrical-ITC
36210 CSW Works Supply
363SAFETY EQUIPMENT - Supplying the following Safety Equipment as per directions of Site Engineer / Engineer-in-Charge complete in all respects including transportation charges:RUBBER HAND GLOVES: Rubber hand gloves suitable for 11/6.6 KV operation with ISI mar k.
364SAFETY EQUIPMENT - Supplying the following Safety Equipment as per directions of Site Engineer / Engineer-in-Charge complete in all respects including transportation charges:Supply and installation of 11/6.6 KV Discharge Rod
365INSULATING MATS - Supply & installation of 2000 mm X 1000 mm and of thickness as mentioned below, approved quality insulating Elasto mer mats as per specifications:Insulating Elastomer mats conforming to IS 15652:2006 of thickness 2 mm (Class A)
366SAFETY EQUIPMENT - Supplying the following Safety Equipment as per directions of Site Engineer / Engineer-in-Charge complete in all respects including transportation charges:Supply of fully charged CO2 fire extinguishers as per specifications (4.5 kg capacit y as per IS: 2878 latest)
367ACDB Panel:Supply of ACDB Panel (IP-4X Degree of Protection) with base frame, 200 A Bus Bar having incomers and feeders, suita ble for 03 phase DG supply, of approved make, as indicated in technical specifications and cable entries from Top, complete in all r espects.
368\"Silent Diesel Generating Set : Supply of CPCB IV compliant Silent Type DG setalong-with processor based AMF system, Industrial Lead-Acid Batteries for Starting o f DG Set, Acoustic Enclosure, exhaust piping with its support structure, internal fuel tank of 12 hrs. capacity etc., as given in th e technical specification complete in all respects 20 KVA, 3-Phase, 415 V\"
369\"Silent Diesel Generating Set : Supply of CPCB IV compliant Silent Type DG setalong-with processor based AMF system, Industrial Lead-Acid Batteries for Starting o f DG Set, Acoustic Enclosure, exhaust piping with its support structure, internal fuel tank of 12 hrs. capacity etc., as given in th e technical specification complete in all respects 30 KVA, 3-Phase, 415 V\"
3701.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH,C2, Smoke density<40% CU,3CX2.5 sqmm,2XWY
3711.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH,C2, Smoke density<40% CU,6CX2.5 sqmm,2XWY
3721.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH,C2, Smoke density<40% CU,2CX4 sqmm,2XWY
3731.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH,C2, Smoke density<40% CU,1CX70 sqmm
3741.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH,C2, Smoke density<40% AL,3CX10 sqmm,A2XFY
3751.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH,C2, Smoke density<40% AL,4CX10 sqmm,A2XFY
3761.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH,C2, Smoke density<40% AL,4CX16 sqmm,A2XFY
3771.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH,C2, Smoke density<40% AL,3.5CX25 sqmm,A2XFY
3781.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH,C2, Smoke density<40% AL,3.5CX50 sqmm,A2XFY
379Electrical resistance based corrosion monitoring system consisting of following items: Flareweld Access Fitting Assembly
380Electrical resistance based corrosion monitoring system consisting of following items: Hollow Plug Assembly
381Electrical resistance based corrosion monitoring system consisting of following items: Heavy Duty Protective Cover
382Electrical resistance based corrosion monitoring system consisting of following items: Primary Packing for Hollow Plug Assembly
383Electrical resistance based corrosion monitoring system consisting of following items: ER Probe Extension Adapter
384Electrical resistance based corrosion monitoring system consisting of following items: Retrievable flush ER probe
385Electrical resistance based corrosion monitoring system consisting of following items: Transmitter (intrinsically safe) as per s pecification including 5 m suitable cable for connection with ER probe.
386Electrical resistance based corrosion monitoring system consisting of following items: Receiver with Safety Barrier & 3 digit LE D display suitable for interfacing with SCADA as per specification.
38720 CSW Works Services
388CABLE TRENCH: :Excavationin unpaved areas of earth in worksites for conventional cable trenches for a depth upto 1.5 metres including shoring,strutting etc. (if necessary), backfilling the trench, job complete in all respects,including alllaboura nd materials complete asper drawings, specification and directionsofSite Engineer / Engineer-in-Charge
389WBM ROAD / CONCRETE BREAKING: :WBM Road/concrete breaking for cable trenches including required shoring strutting etc., and repa iring of the road/dyketooriginal condition and disposing off excess materials(within thework site) job complete in all r espects including the cost of labour, tools, materials, load, lifthire charges of equipments, ifany, complete asper drawings , specification and directionsofSite Engineer / Engineer-in-Charge.
390Cable Laying - Layingofall typeof cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cabl e racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and inst allation of all required materialssuch as fixingclamps, screws, cable straps, tags, etc.as required (other than the supplyofthe conduits, cables, pipes, cable racks, trays,poles,structures and panels) complete in all respect, including cost of allla bour, tools, consumable materials, etc. and cutting the cables in required lengths asper drawings, specification and directionso fSite Engineer / Engineer-in-Charge: :Power cables LT : OD upto 20 mm
391Cable Laying - Layingofall typeof cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cabl e racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and inst allation of all required materialssuch as fixingclamps, screws, cable straps, tags, etc.as required (other than the supplyofthe conduits, cables, pipes, cable racks, trays,poles,structures and panels) complete in all respect, including cost of allla bour, tools, consumable materials, etc. and cutting the cables in required lengths asper drawings, specification and directionso fSite Engineer / Engineer-in-Charge: :Power cables LT : OD above 20 mm and upto 40 mm
392Cable Laying - Layingofall typeof cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cabl e racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and inst allation of all required materialssuch as fixingclamps, screws, cable straps, tags, etc.as required (other than the supplyofthe conduits, cables, pipes, cable racks, trays,poles,structures and panels) complete in all respect, including cost of allla bour, tools, consumable materials, etc. and cutting the cables in required lengths asper drawings, specification and directionso fSite Engineer / Engineer-in-Charge: :Control cables (T&I) : OD upto 20 mm
393Cable Laying - Layingofall typeof cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cabl e racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and inst allation of all required materialssuch as fixingclamps, screws, cable straps, tags, etc.as required (other than the supplyofthe conduits, cables, pipes, cable racks, trays,poles,structures and panels) complete in all respect, including cost of allla bour, tools, consumable materials, etc. and cutting the cables in required lengths asper drawings, specification and directionso fSite Engineer / Engineer-in-Charge: :Control cables (T&I) : OD above 20 mm and upto 30 mm
394Cable Laying - Layingofall typeof cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cabl e racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and inst allation of all required materialssuch as fixingclamps, screws, cable straps, tags, etc.as required (other than the supplyofthe conduits, cables, pipes, cable racks, trays,poles,structures and panels) complete in all respect, including cost of allla bour, tools, consumable materials, etc. and cutting the cables in required lengths asper drawings, specification and directionso fSite Engineer / Engineer-in-Charge: :Control cables (T&I) : OD above 30 mm and upto 40 mm
395Cable Laying - Layingofall typeof cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cabl e racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and inst allation of all required materialssuch as fixingclamps, screws, cable straps, tags, etc.as required (other than the supplyofthe conduits, cables, pipes, cable racks, trays,poles,structures and panels) complete in all respect, including cost of allla bour, tools, consumable materials, etc. and cutting the cables in required lengths asper drawings, specification and directionso fSite Engineer / Engineer-in-Charge: :Installation, laying of 2 Pair PVC insulated copper conductor un-armoured telephone cabl es in 16 mm/ 25 mm/ 32 mm PVC conduits from IDFthrough ceiling/ wall/trench and post-laying end to end testing of telephone cables . The job includes supply, installation, fixing of wall mounted telephone socket outlet with 2 port telephone jack face plate (white / cream colour) including RJ11 I/O with modular plate & switch box/ gang box for fixing the face plate & accessories, supply and ins tallation of PVC Conduits, all required materials such as fixing clamps, screws, cable straps, tags etc. as requiredcomplete in al l respects as per specifications & scope of work, drawings and directions of Site Engineer/ Engineer-in-charge including cost of alllabour, tools & tackles, materials etc.
396Cable Laying - Layingofall typeof cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cabl e racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and inst allation of all required materialssuch as fixingclamps, screws, cable straps, tags, etc.as required (other than the supplyofthe conduits, cables, pipes, cable racks, trays,poles,structures and panels) complete in all respect, including cost of allla bour, tools, consumable materials, etc. and cutting the cables in required lengths asper drawings, specification and directionso fSite Engineer / Engineer-in-Charge: :Installation, laying of Cat 6 LAN Cables in 16 mm/ 25 mm/ 32 mm PVC conduits from networ k switch through ceiling/wall/trench and post-laying end to end testing of cables. The job includes supply, installation & fixing ofDuplex (2 port) Face plate (Network I/O point) (white/ cream colour) for Local Area Network including RJ45 I/O, modular plate & swi tch box/ gang box for fixing the face plate & accessories, supply and installation of PVC Conduits, all required materials such as f ixing clamps, screws, cable straps, tags etc. as required complete in all respects as per specifications & scope of work, drawings a nd directions of Site Engineer/ Engineer-in-charge including cost of all labour, tools & tackles, materials etc.
397Silent LT DG set - Erection, Installation including transportation from owner desginated location, connecting, testing and commissio ning of owner supplied Emergency LT DG set including execution of terminal connection of power/control cable. The work shall includegrounding of alternator neutral, earthing, providing water pipe connection for Radiator water make-up complete with valve, solenoidvalve etc. piping for fuel line, fabrication, welding, erection and painting of owner supplied support structure (including supply of shortfall support structure, if any) for exhaust piping, mounting on channels/AVM pads, installation of PLC based AMF panel, NIG panel, exhaust piping including insulation and cladding, fuel piping etc., materials, labour, tools and tackles, consumables etc , a sper drawings, specification and directionsofSite Engineer / Engineer-in-Charge: :LT DG set with PLC based AMF panel, fueltank etc
398\"LT Panel - Erection, installation including transportation from owner desginated location, testing and commissioning of415 V, own er supplied power-control- centres, motor control centres, soft starters, APFC panel etc. assembling as required, installation on th e already made foundation channels, aligning, levelling, grouting, assembling, making all the inter connections /outgoing/incoming p ower & control cable/ bus duct connection including making holes for cable entries as required as per drawing, specifications and di rections of the Site Engineer/Engineer-in-Charge including cost of all materials, tools labour etc. complete in all respect includin g termination of all power, control cables, installation of thermistor controller, internal wiring, earthing of LT panels, supply ofcable glands etc.complete as per cable schedule, drawings etc.: :Weight of unit above 1000 kgbut upto and including 3000 kg \"
399Corrosion monitoring probes: :Installation of corrosion monitoring probes including 2\" Flareweld on station piping at desired lo cation and 12 O\"Clock position for mounting of ER Probe under the supervision of site engineer. Flareweld assembly shall be suppliedby owner. The job complete in all respect with material, tools & tackles, consumables etc.
400Erection, Installation,Testing & Commissioning of the Owner supplied high mast tower with the help of suitable tools and plants, wir ing of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5sq. mm, lugs, MCB and all labour.Scope of work shall include erection & installation of high mast tower, cable connections, erect ion & installation of luminaries & aviation lights, lightning finial,all accessories, cables, etc., erection, foundation casting &grouting of owner supplied FLP feeder pillar, end connection termination & laying of Owner supplied cable from feeder pillar to bas ecompartment of high mast complete with all materials and labour as per instruction of Site Engineer/EIC. Earthing works for High Mast tower including construction of earth pits to be operated in relevant separate item.:For 30 M Height High Mast Tower
40130 CSW Works Composite
402GI CABLE TRAY: :Supply, installation & fixing of prefabricated perforated GI cable trays with tray cover of width 150 mm, 300 mm , 450 mm & 600 mm as per site requirement for laying of cables with standard rung spacings. Load for support span of 2.5 meter as 30 , 60, 75 & 90 (in Kg/Mtr) respectively with concentric static load as 70 Kg at the centre, with materials, labour, tools and tackles , consumables etc , asper drawings, specification and directions of Site Engineer / Engineer-in-Charge.
403CABLE MARKER: :Supply, erection & installation of MS cable markers, including excavation, installation of the markers, cement co ncrete grouting, backfilling, materials, labour, tools and tackles, consumables etc , asper drawings, specification and directions ofSite Engineer / Engineer-in-Charge.
404LT Cable joint (1.1 KV) - Making straight through joints on Al/Cu conductor XLPE/PVC insulated armoured cable including the supply o f required materials such as cable jointing kit (of heat shrinkable sleeve type of Raychem/Mseal/3M) , materials, labour, tools and tackles, consumables etc , asper drawings, specification and directionsofSite Engineer / Engineer-in-Charge: :Power cablesLT : OD upto 20 mm
405LT Cable joint (1.1 KV) - Making straight through joints on Al/Cu conductor XLPE/PVC insulated armoured cable including the supply o f required materials such as cable jointing kit (of heat shrinkable sleeve type of Raychem/Mseal/3M) , materials, labour, tools and tackles, consumables etc , asper drawings, specification and directionsofSite Engineer / Engineer-in-Charge: :Power cablesLT : OD above 20 mm and upto 40 mm
406EARTH ELECTRODES: :Supplying, installation, testing of GI earthing electrode, including the supply and installationof the CI c over, charcoal /special backfill etc. and construction of chamber; complete asper drawings,specifications and directions of the Si te Engineer, Including thecostof alllabour, tools, materials etc. completein all respects.
407EARTHING SYSTEM SET (06 PITS)::Supply, installation, testing of earthing system consisting of 6 earth pits of perforated GI pipe s earthing electrodes and copper plate terminal block including construction of chamber using cement concrete with earthing pit cove r and frame, supply of charcoal, salt etc including supply of interconnecting cables / strips including necessary welding etc comple te as per drawings, specifications and directions of the site engineer, including cost of tools, materials etc complete in all respe cts as per drawing The job shall also include testing of each earth pit and the entire earthing system on whole. (Note: Earthing forfield instruments shall be provided from Station earth grid covered in Electrical SOR.)
408EARTHING SYSTEM SET (03 PITS): :Supply, installation, testing of earthing system consisting of 3 earth pits of perforated GI pip es earthing electrodes and copper plate terminal block including construction of chamber using cement concrete with earthing pit cov er and frame, supply of charcoal, salt etc including supply of interconnecting cables / strips including necessary welding etc compl ete as per drawings, specifications and directions of the site engineer, including cost of tools, materials etc complete in all resp ects as per drawing The job shall also include testing of each earth pit and the entire earthing system on whole. (Note: Earthing fo r field instruments shall be provided from Station earth grid covered in Electrical SOR.)
409EARTH STRIP / WIRE / ROPE / CABLE - Supply, installing and testing of earthing strip/wire/rope/cable forcompletely making the eart hing grid system by supplying, laying theGI / Cu strip and makingall the necessaryweldingjoints, connecting to the earthing electrodesand existing earthinggridetc., complete as per drawings, specifications and directions of the Site engineer/Engineer -in-charge, including the cost of all labour, tools, materials, etc. complete in all respect: :50 mm X 6 mm G.I. earthing strip
410EARTH STRIP / WIRE / ROPE / CABLE - Supply, installing and testing of earthing strip/wire/rope/cable forcompletely making the eart hing grid system by supplying, laying theGI / Cu strip and makingall the necessaryweldingjoints, connecting to the earthing electrodesand existing earthinggridetc., complete as per drawings, specifications and directions of the Site engineer/Engineer -in-charge, including the cost of all labour, tools, materials, etc. complete in all respect: :40 mm X 5 mm G.I. earthing strip
411EARTH STRIP / WIRE / ROPE / CABLE - Supply, installing and testing of earthing strip/wire/rope/cable forcompletely making the eart hing grid system by supplying, laying theGI / Cu strip and makingall the necessaryweldingjoints, connecting to the earthing electrodesand existing earthinggridetc., complete as per drawings, specifications and directions of the Site engineer/Engineer -in-charge, including the cost of all labour, tools, materials, etc. complete in all respect: :25mm x 4 mm copper flat
412EARTH STRIP / WIRE / ROPE / CABLE - Supply, installing and testing of earthing strip/wire/rope/cable forcompletely making the eart hing grid system by supplying, laying theGI / Cu strip and makingall the necessaryweldingjoints, connecting to the earthing electrodesand existing earthinggridetc., complete as per drawings, specifications and directions of the Site engineer/Engineer -in-charge, including the cost of all labour, tools, materials, etc. complete in all respect: :GI wire(8 SWG)
413EARTH STRIP / WIRE / ROPE / CABLE - Supply, installing and testing of earthing strip/wire/rope/cable forcompletely making the eart hing grid system by supplying, laying theGI / Cu strip and makingall the necessaryweldingjoints, connecting to the earthing electrodesand existing earthinggridetc., complete as per drawings, specifications and directions of the Site engineer/Engineer -in-charge, including the cost of all labour, tools, materials, etc. complete in all respect: :Copper cable as per specification s - 100 Sq.mm
414EARTH STRIP / WIRE / ROPE / CABLE - Supply, installing and testing of earthing strip/wire/rope/cable forcompletely making the eart hing grid system by supplying, laying theGI / Cu strip and makingall the necessaryweldingjoints, connecting to the earthing electrodesand existing earthinggridetc., complete as per drawings, specifications and directions of the Site engineer/Engineer -in-charge, including the cost of all labour, tools, materials, etc. complete in all respect: :Copper cable as per specification s - 10 Sq.mm
415Supply, erection & installation of cable conduits made up of GI pipes of medium class \"B\" subject to owner\"s approval in trenches (a lready made), on walls, concrete structure etc., including supply and installation of all the necessary pipe fittings such as bends,sockets, elbows, tees etc., bending, threading, binding, clamping, providings, spacers, plugs, packings, bushings etc., as required Job complete in all respects including the cost of all labour, tools, material etc.and as per specifications and directions of s ite engineer / Engineer-in-Charge: :25 mm
416Supply, erection & installation of cable conduits made up of GI pipes of medium class \"B\" subject to owner\"s approval in trenches (a lready made), on walls, concrete structure etc., including supply and installation of all the necessary pipe fittings such as bends,sockets, elbows, tees etc., bending, threading, binding, clamping, providings, spacers, plugs, packings, bushings etc., as required Job complete in all respects including the cost of all labour, tools, material etc.and as per specifications and directions of s ite engineer / Engineer-in-Charge: :37 mm
417Supply, erection & installation of cable conduits made up of GI pipes of medium class \"B\" subject to owner\"s approval in trenches (a lready made), on walls, concrete structure etc., including supply and installation of all the necessary pipe fittings such as bends,sockets, elbows, tees etc., bending, threading, binding, clamping, providings, spacers, plugs, packings, bushings etc., as required Job complete in all respects including the cost of all labour, tools, material etc.and as per specifications and directions of s ite engineer / Engineer-in-Charge: :50 mm
418Supply, erection & installation of cable conduits made up of GI pipes of medium class \"B\" subject to owner\"s approval in trenches (a lready made), on walls, concrete structure etc., including supply and installation of all the necessary pipe fittings such as bends,sockets, elbows, tees etc., bending, threading, binding, clamping, providings, spacers, plugs, packings, bushings etc., as required Job complete in all respects including the cost of all labour, tools, material etc.and as per specifications and directions of s ite engineer / Engineer-in-Charge: :100 mm
419STEEL STRUCTURAL WORKS:Supply, fabrication, erection, installation of steel structural works of any type and shape such as cableraks, cable trays, push button control posts etc., as requiredjob complete in all respects including the cost of all labour, tool s, material etc., complete.and as per specifications and directions of site engineer/ Engineer-in-Charge.
420FLAME PROOF FITTINGS - All equipment under this category shall be suitable (minimum requirments) for location in zone-I gas group II A & IIB (Temp. class T3) area with a separate terminal box for incoming cable and a separate terminal box for out going cable (whereapplicable), apart from separate enclosure for each equipment including control gear etc. in IP 65 cast aluminium LM-6 certified en closure: :FLAMEPROOF TUBELIGHT, 2x22Watt, LED, SUITABLE FOR Exd Gas Group II C, as per IS/IEC 60079-2007
421FLAME PROOF FITTINGS - All equipment under this category shall be suitable (minimum requirments) for location in zone-I gas group II A & IIB (Temp. class T3) area with a separate terminal box for incoming cable and a separate terminal box for out going cable (whereapplicable), apart from separate enclosure for each equipment including control gear etc. in IP 65 cast aluminium LM-6 certified en closure: :FLAMEPROOF LED WELL GLASS FITTING 125 W, Supply, installation, testing & commissioning of Ex\"d\" (Flameproof) Well Glas s Light Fixture with provision ofCable Entries: 2 Nos. x 3/4\" ET, Cable Glands: 2 Nos. x 3/4\" ET (Max. OD 20mm) - Ex\"d\"(IIA/IIB), Double Compression type, Brass Nickel Plated with PVC Hood. Blanking Plug: 1 No. x 3/4\" ET - Ex\"d\", Brass Nickel Plated. Gasket: Neo prene, Hardware: SS 304, Earthing: External 2 Nos. (M6), Internal 1 No. (M5), and as per attached detailed technical specification.
422FLP & WP JUNCTION BOX - Supply, erection, installation, testing andcommissioning of flameproof & weather proof junction box for pr oviding cable termination of motor, including connection and termination of earthing wire and conduits etc., including supply & inst allation of double compression cable glands & flame proof plugs for sealing all spare entries complete as per drawings, specificatio ns and direction of the Site Engineer, including the cost of all labour, tools, consumable materials etc., complete in all respect: :4 way junction box with 4 cable entries (4 x 3/4\") at bottom & 20 nos. terminals.
423FLP/WP EXHAUST FANS: :Flame proof, weather proof, single phase, 12\" exhaust fan, IP65, LM6 type EF1001 of FCG or equivalent alon gwith supporting frame, bolts, louvers, flame proof motor, including supply & installation of double compression cable glands & flam e proof plugs for sealing all spare entries, complete in all respects
424SHOCK TREATMENT CHART: :Supply and installation of shock treatment chart framed in good qualityglass in English / Hindi / Loca l Language.
425CAUTION BOARD: :Supply and installation of vitreous enamel caution boards suitable for 440 V/11KV/6.6 KVas per IS 255 includin g fixing on the wall with all the required hardware etc. complete in English / Hindi/ Local Language.
426Point wiring - Supplying, installation and testing with 1.5 Sq.mm stranded PVC insulated copper conductor wires for phase & neutral of 650V grade including earthing by providing 1.5 Sq.mm earth insulated continutity wire of copper in PVC conduit (Supply & installa tion of PVC conduit covered elsewhere in SOR) recessed on wall/ceiling/ false celing including supply & installation of switch boxes ,junction boxes, pull boxes, bushes, screws, check nuts, bends, modular switches and sockets . Thecircuit wiring with 4 Sq.mm PVC copper wire from D.B. to switchboard as required is also in the scope of the contractor: :1 light point controlled by 1 switch
427Point wiring - Supplying, installation and testing with 1.5 Sq.mm stranded PVC insulated copper conductor wires for phase & neutral of 650V grade including earthing by providing 1.5 Sq.mm earth insulated continutity wire of copper in PVC conduit (Supply & installa tion of PVC conduit covered elsewhere in SOR) recessed on wall/ceiling/ false celing including supply & installation of switch boxes ,junction boxes, pull boxes, bushes, screws, check nuts, bends, modular switches and sockets . Thecircuit wiring with 4 Sq.mm PVC copper wire from D.B. to switchboard as required is also in the scope of the contractor: :2 light points controlled by 1 switch
428Point wiring - Supplying, installation and testing with 1.5 Sq.mm stranded PVC insulated copper conductor wires for phase & neutral of 650V grade including earthing by providing 1.5 Sq.mm earth insulated continutity wire of copper in PVC conduit (Supply & installa tion of PVC conduit covered elsewhere in SOR) recessed on wall/ceiling/ false celing including supply & installation of switch boxes ,junction boxes, pull boxes, bushes, screws, check nuts, bends, modular switches and sockets . Thecircuit wiring with 4 Sq.mm PVC copper wire from D.B. to switchboard as required is also in the scope of the contractor: :3 light points controlled by 1 switch
429Point wiring - Supplying, installation and testing with 1.5 Sq.mm stranded PVC insulated copper conductor wires for phase & neutral of 650V grade including earthing by providing 1.5 Sq.mm earth insulated continutity wire of copper in PVC conduit (Supply & installa tion of PVC conduit covered elsewhere in SOR) recessed on wall/ceiling/ false celing including supply & installation of switch boxes ,junction boxes, pull boxes, bushes, screws, check nuts, bends, modular switches and sockets . Thecircuit wiring with 4 Sq.mm PVC copper wire from D.B. to switchboard as required is also in the scope of the contractor: :4 light points controlled by 1 switch
430Ceiling fan wiring: :Wiring with PVC insulated 2.5 sqmm copper conductor wire for fan points (1 fan point controlled by 1 modula r switch) including providing space for electronic regulator in switch box, providing and fixing fan hook in the ceiling as per spec ifications and drawings.
431Exhaust fan / wall bracket fan wiring: :Wiring with PVC insulated 2.5 sqmm copper conductor wire for phase & neutral , 650 V gra de including earthing , the third pin with 1.5 sqmm copper conductor earthing insulated continuity wire for exhaust/ wall bracket fa n including providing and fixing of 5 pin 6 A modular socket and 10 A modular switch near the door or as as per specifications and d rawings. The circuit wiring shall be with 4 sq. mm PVC copper wire from switchboard to 1st exhaust fan for multiple exhaust fans in one circuit.
43216 A power plug point wiring: :Wiringfor 250 V single phase and neutral 16 amps modular power plug point with PVC insulated 4 sq. mm. copper conductor wires for phase & neutral, 650 V grade including earthing, the third pin with 2.5 sq. mm copper conductor e arthing insulated continuity wire, complete with providing and fixing of 6 pin 16/6A modular socket and 20/10 A modular switch (1 pl ug point per circuit) as per specifications and drawings
4336 A plug point wiring: :Wiring for 250 V single phase and neutral 6 amps modular plug point with PVC insulated 2.5 sq. mm. coppe r conductor wires for phase & neutral, 650 V grade including earthing, the third pin with 1.5 sq. mm copper conductor earthing insul ated continuity wire, complete with providing and fixing of 5 pin 6A modular socket and 10 A modular switch (1 plug point per circui t) as per specifications and drawings.
434\"AC point wiring: :Point wiring for power plug point with 4 sq.mm stranded PVC insulated copper wire including earthing the thir d pin with 2.5 sq. mm copper insulated earthing wire complete with supply and fixing of recessed mounted industrial type 3 pin 32 A metal cladsocket and plug, 20A MCB (Motor duty) housed in a 16 gauge M.S. Box \"
435Lighting Distribution Board / AC Distribution Board - Supply , installation, testing and commissioning of TPN lighting / AC Distribu tion board ofapproved make, with rating and feeders as per specification. The DB shall be of IP-42 protection class and shall conf orm to IS 8623. The board shall be fitted with an acrylic door as per specifications and drawings: :Type III Distribution Board:Double Door EURODB of Havells or equivalent approved make having bus bar 200 A TPN, 1 Incomer 125 A FP MCB Isolator with 125 A FP R CCB (Senstivity 100 mA) alongwith 3 numbers 63 A TPN MCB as per specification.
436Lighting Distribution Board / AC Distribution Board - Supply , installation, testing and commissioning of TPN lighting / AC Distribu tion board ofapproved make, with rating and feeders as per specification. The DB shall be of IP-42 protection class and shall conf orm to IS 8623. The board shall be fitted with an acrylic door as per specifications and drawings: :Type IV DIstribution Board: Double Door Translucent Euro DB of Havells or approved make, having 100 A TPN Copper Bus bar, 1x63 A TPN MCB , 1x63 A RCCB (100 mA S ensitivity), 9x6A SP MCB & 6x20 A SP MCB as per specification
437Lighting Distribution Board / AC Distribution Board - Supply , installation, testing and commissioning of TPN lighting / AC Distribu tion board ofapproved make, with rating and feeders as per specification. The DB shall be of IP-42 protection class and shall conf orm to IS 8623. The board shall be fitted with an acrylic door as per specifications and drawings: :Type V Distribution Board: D ouble Door, EURO DB of Havells or equivalent approved make having 200 A TPN Bus Bar, 1 x 100 A FP MCB, 1x100 A FP RCCB (100 mA Sensi tivity), 9x32 A SPN Motor duty MCB as per specification.
438Lighting Distribution Board / AC Distribution Board - Supply , installation, testing and commissioning of TPN lighting / AC Distribu tion board ofapproved make, with rating and feeders as per specification. The DB shall be of IP-42 protection class and shall conf orm to IS 8623. The board shall be fitted with an acrylic door as per specifications and drawings: :Critical Light DB: Euro DB D BOXx of Havells or equivalent make complete with bus bar, neutral links, earth links and 1 x 6 A MCB SPN & 7x2 A SPN MCB
439Decorative Light fittings - Supply, installation, connection, earthing and testing of the following fittings, including supply and i nstallation of drop pipes, hooks, fittings, fixtures, nuts,bolts, supports, on walls, outlet box for regulators and all other requir ed materials etc. as per specifications, drawings and directions of the Site Engineer including cost of all labour, tools, materialsetc. complete in all respects.Make of the fittings can be the make mentioned in the respective SOR items or equivalent model from t he approved make list given in the specifications: :LED light fittings, Recess mounting type, Sereno LED-RC869B LED 30S-6500 PSEW30L120 D8 or equivalent approved make with LEDs: Supply and fixing of recess mounted weather prooflight Sereno LED-RC869B LED 30 S-6500 PSE W30L120 D8 or equiavlent approved make with LEDs, 42 W or more, having 2950 lumens or more output. LED Fitting of PHILLIP S or equivalent approved make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc i ncluding installation with LED of approved make.
440Decorative Light fittings - Supply, installation, connection, earthing and testing of the following fittings, including supply and i nstallation of drop pipes, hooks, fittings, fixtures, nuts,bolts, supports, on walls, outlet box for regulators and all other requir ed materials etc. as per specifications, drawings and directions of the Site Engineer including cost of all labour, tools, materialsetc. complete in all respects.Make of the fittings can be the make mentioned in the respective SOR items or equivalent model from t he approved make list given in the specifications: :LED light fittings with LEDs, Sereno LED-Suspended-SP824 P LED 30S-5000 GR O D or approved equivalent:Supply and fixing of surface mounted weather prooflight SP824 P LED 42 W having 2950 lumens output fittin g of PHILLIPS or equivalent approved make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc including installation with LED of approved make.
441Swan neck lighting pole with LED well glass light: :Supply, installation, testing and commissioning of swan neck lighting pole o f100mm nominal Diameter B class MS pipe (Height of bottom of light fitting shall be 5 meters from FGL), having base Plate 200mmx20 0mmx5mmalong with Flameproof and Weatherproof 2x18W LED well glass light fitting complete with lamp and builtin control gear and c hoke of approved make, including supply and installation of earthing conductor of 8 SWG GI wire, nuts, bolts, Neck portion of lighti ng pole shall made up be of 50mm diameter GI pipe (radius of neck shall be 250mm). The pole shall be painted with 01 coat of primer and 02 coats of aluminium paint. The job shall also include supply and installation of 4 way Flameproof/weather proof junction box ( with 4 cable entries) having 8 Nos., 6A, 440V shrouded terminal, with double compression FLP glands/lugs with looping arrangement an d supply and termination of 3C X 2.5 sq. mm. armoured copper PVC/XLPE insulated cable from JB to light fitting The job complete in a ll respects as per specifications, drawings and instructions of EIC / Site engineer.
442Ceiling fan: :Ceiling fan, BEE 5 star rated,with electronic regulator & other accessories and fittings etc. of or approved mak e with 56\" Sweep size
443Wall mounted fan: :12\" Oscillating wall mounted bracket fan, noiseless, plastic moulded construction, rotary device for 3 step s peed control integrated unit of approved make with all accessories complete in all respect.
444Exhaust fan - Supply, installation, testing of single phase 230 V, industrial type heavy duty exhaust fan of GEC/Usha/Crompton Greav es or of approved make fitted/ provided with louvres, supports etc. including making the required opening on walls, fixing and conne cting the wires etc. including earthing the body of the fan, making good the opening on the wall etc. complete as per specifications , drawings and direction of Site Engineer including the cost of all labour, tools, materials etc. complete.:18\" Sweep
445Exhaust fan - Supply, installation, testing of single phase 230 V, industrial type heavy duty exhaust fan of GEC/Usha/Crompton Greav es or of approved make fitted/ provided with louvres, supports etc. including making the required opening on walls, fixing and conne cting the wires etc. including earthing the body of the fan, making good the opening on the wall etc. complete as per specifications , drawings and direction of Site Engineer including the cost of all labour, tools, materials etc. complete.:12\" Sweep
446PVC Conduit pipes - Supply, installation, fixing in position, PVC conduit pipes, of ISI marked , in concrete, brick work etc. duringor after construction by making grooves in the wall, ceiling etc. cutting threads and jointing the pipes with PVC couplers, providi ng necessary tees, bends, junction boxes etc. with 12 SWG GI wire inside conduit without joint for concealed wiring, including makin g good the concrete, brick work, surfaces etc. complete as per drawings and direction of Site Engineer / Engineer-in-charge includin g cost of all labour, materials etc.: :19 mm
447PVC Conduit pipes - Supply, installation, fixing in position, PVC conduit pipes, of ISI marked , in concrete, brick work etc. duringor after construction by making grooves in the wall, ceiling etc. cutting threads and jointing the pipes with PVC couplers, providi ng necessary tees, bends, junction boxes etc. with 12 SWG GI wire inside conduit without joint for concealed wiring, including makin g good the concrete, brick work, surfaces etc. complete as per drawings and direction of Site Engineer / Engineer-in-charge includin g cost of all labour, materials etc.: :25 mm
448PVC Conduit pipes - Supply, installation, fixing in position, PVC conduit pipes, of ISI marked , in concrete, brick work etc. duringor after construction by making grooves in the wall, ceiling etc. cutting threads and jointing the pipes with PVC couplers, providi ng necessary tees, bends, junction boxes etc. with 12 SWG GI wire inside conduit without joint for concealed wiring, including makin g good the concrete, brick work, surfaces etc. complete as per drawings and direction of Site Engineer / Engineer-in-charge includin g cost of all labour, materials etc.: :32 mm
449Supplying and laying reinforced cement concrete light duty hume pipe, non pressure type (NP3), centrifugallycast conforming to I.S .458 with 1:3:6concrete casing at joints as required with necessary slope including excavation, backfilling, supply of collars, jo inting of pipes with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement: 2 fine sand), testing of joints, complete i n all respects as per specifications, drawingand the direction of the EIC/Site Engineer: :300 mm dia
450Supply fixing and erection of modular cable transit (MCT) for cable entry to building in proper frame including supply of peelable t ype, spare block, stay plates compression wedgs etc. with all accessories as per specification considering 20 % minimum spare in eac h module to be installed as per instruction of Engineer in charge/ site engineer: :Galvanised mild steel frame with packing spac e of Min.120x240 mm with multi diameter blocks and accessories with peeling off arrangement to adjust cable size from 3.5mm to 99mm outer dia
451Lightining Arrestor: :Supply, installation and testing of Lightning arrestor on top of the MOV buiding or MOV CP buiding for div erting lightning surges to the ground. The work shall include supply of 1.2 Meter long copper lightning arrestor with 5 spronged phe nyl rod base plate etc. complete with necessary insulators including supply and fixing of 50 x 6 mm GI earthing strip of required le ngth and connection to the main earthing grid.
452Construction of shallow foundation with M20 grade concrete for the highmast considering the safe soil bearing capacity at site as 10T/sqmtr at 2 metre depth complete with all materials and labour as per instruction of Site Engineer/EIC. Design of foundation shallbe provided by IOCL. Piling work if required as per soil strata in foundation of high mast is not covered in this scope of work andshall be taken up separately.:For 30 M Height High Mast Tower
453Tele & Inst works CSW HRPL
4541 Telecom and OFC
4551 Supply
456Supply of permanently-lubricated HDPE pipe of 40 mm OD (as per TEC GR) with minimum pressure rating of 8 Kg/cm2 and wall thickness of 3.5 mm, along with duct accessories such as couplers, end caps, end sealing plugs, warning tape etc.
457Supply ofOFC Jointing kits as per tender specifications.
458Supply of Electronic Marker Locator cum Cable/ Pipe Locator, Fault Locator as per tender specifications
459Supply of full range (upto 8 feet) RF iD Disk type Electronic Markers as per tender specifications
460Supply of pre-fabricated printed KM markers for OFC & HDPE as per tender specifications
461Supply of Joint pit markers for OFC joint locations as per tender specifications
462Supply ofpre-fabricated RCC (1:1.5:3) Joint Box with lid as per tender specifications
463Supply of Transition pits for building entry points as per tender specifications
464Supply of 89 mm OD, Schedule 80, API 5L Grade-B/ ASTM A106 MS pipe for cable conduit as per tender specifications
465Supply of wall mounted Fibre Termination Box (FMS) as per tender specifications
4662 Service
467Laying of HDPE pipe (excluding blowing of OFC) inmainline pipe trench at the bottom in all types of soil (including roads, canals,rivers, nullahs, water course crossings, submerged crossings, saltpan areas etc.) including supply and installation of suitable str aps for strapping the HDPE duct with mainline pipe for anti buoyancy, installation of HDPE duct accessories such as plastic couplers , end caps, end plugs, cable sealing plugs, supply and installation of warning tape, consumable guide rods, HDPE jointing, inspectio n of HDPE joints, testing the installed HDPE duct by blowing \"mandrel\" with compressed air,pressure testing the HDPE pipe after la ying as per procedure and performing all work as per drawings, specifications and instruction of the Engineer-in-charge/ Site Engine er and provisions of the contract document for making the duct ready in all respect for OFC blowing. The job includes transportation , loading and unloadingof HDPE ducts in nominal length of 1000 meters and duct accessories such as couplers, end caps, end sealingplugs etc. to various sites along the entire ROW / HDD crossinglocations as per specifications and directions of Engineer-in-char ge/ Site Engineer
468Laying of HDPE Pipe in trenches/ walls/ concrete structure/ panels etc. as per specifications & drawings & blowing/ laying of Owner supplied Aurmoured/Unarmoured Optical Fibre Cable in HDPE pipe,jointing & splicing of OFC, carrying out end to end testing of laid Optical fibre cables by taking OTDR traces and submitting the OTDR trace printouts to Site Engineer/ Engineer-in-charge. The job includes the supply and installation of required materials such as fixing clamps, screws, tags etc. as required to complete the job in all respects as per drawings and directions of Site Engineer/ Engineer-in-charge including cost of all labour, tools & tackles, test instruments, materials etc. The job includes handing over the tested cables to the Telecom Works Contractor and providing necessary assistance/ support to the Telecom Works Contractor in commissioning of Local Area Network.
469Trenching for laying of HDPE in Independent trench Excavationin unpaved areas of earth in worksites for conventional cable trenches for a depth upto 1.65 metres including shoring,strutting etc. (if necessary), backfilling the trench, as directed byEngineer-in-charge/ Site Engineer,including alllabourand materials complete asper drawings and tender specifications
470Transportation (loading and unloading) of Owner supplied unarmoured Optical fibre cable (OFC) to various sites along Right of Way (R OW), pre laying testing of each cable drum for each fibre and taking the OTDR traces, submission of OTDR traces (in hard as well as soft copy) to Engineer-in-charge/ Site Engineer, blowing of OFC through contractor laid HDPE, jointing / splicing of OFC, post insta llation testing of OFC for each fibre for each drum laid & taking OTDR traces, submission of OTDR traces (in hard as well as soft co py) to Engineer-in-charge/ Site Engineer as per the scope, specifications and directions of Engineer-in-charge/ Site Engineer
471Installation of OFC jointing kits as per drawings, specifications and directions of Engineer-in-charge/ Site Engineer
472Installation of RF iD type Electronic Markers as per tender specifications. The job includes configuration & programming of the Elec tronic markers to write information data as per directions of Engineer-in-charge/ Site Engineer.
473Installation of pre-fabricated printed KM markers for OFC & HDPE as per tender specifications, drawings and directions of Engineer-i n-charge/ Site Engineer
474Installation of OFC Joint pit markers at every joint location as per specifications, drawings and directions of Engineer-in-charge/ Site Engineer
475Installation of pre-fabricated RCC (1:1.5:3) Joint Box with lidas per tender specifications, drawings and directions of Engineer-i n-charge/ Site Engineer.
476Installation of Transition Pits at building entry points as per tender specifications, drawings and directions of Engineer-in-charge / Site Engineer
477Installation of wall mounted Fibre Termination Box (FTB) as per tender specifications and directions of Engineer-in-charge/ Site Engineer
4783 Composite
479Supply and installation of IDF (intermediate distribution frame) / Distribution box of20 Pair capacity with mounting arrangement a s per specifications
480Supply and installation of IDF (intermediate distribution frame) / Distribution box of10 Pair capacity with mounting arrangements as per specification.
481Supply and installation of MDF (Main distribution frame) /Distribution box of50 Pair capacity as per specifications
482Laying ofHDPE conduit and blowing of OFC cable inside the SV/MOV premises along the boundary wall, line item includes supply & installation ofsuitable clamps , connectors, fixture, corner bends, tools & tackles (comprising of anchor bolts/nuts/accessories etc) required for OFC entry inside SV/MOV loctaionalong theboundary wall by clamping of HDPE conduit at a height of 1 meter above the finished ground level and extending it along the length of boundary wall at 1 meter height upto the transition pit inside SV/RCP building as per attached drawing no. STD-793-00. The line item includes all sevices required for blowing of OFC cable iin HDPE conduit inside the MOV/SV loctaion as per STD - 793 drawing.
4832 Instrumentation
4841 Supply
485Supply of Pressure Indicators (PI) of the range 0 to 5 Kg / Cm2 as per the technical specifications attached in the Tender
486Supply of Pressure Indicators (PI) of the range 0 to 100 Kg / Cm2 as per the technical specifications attached in the Tender.
487Gauge Saver (0-1 Kg/Cm2)
488Supply of flame proof and weather proof fittings including EP/WP certificates as per the technical specifications attached.
489FLP/ WP Junction Box, Type C. (Nos. of terminals: 60 Nos.; Bottom entry: 1 No. - 1 1/4\" & 1 No.- 1\"; Left side entry: 1 No. - 1\" & 3Nos.- 1/2\"; Right side entry: 2 No. - 1\" & 2 Nos.- 1/2\") along with FLP cable glands & FLP plugs for all the cable entries of the J unction as per technical specifications.
490FLP/ WP Junction Box, Type D. (Nos. of terminals: 24 Nos.; Bottom entry: 1 No. - 1\"; Left side entry: 3 Nos.- 1/2\"; Right side entry : 3 Nos.- 1/2\") along with FLP cable glands & FLP plugs for all the cable entries of the Junction as per technical specifications.
491FLP/ WP Emergency Shut Down Push Button Switch(with2 nos. cable entry provision of 1/2\" NPT) with steel hammer chained with mainunit.
492Supply of Cable Glands - flame proof and weather proof including EP/WP certificates:
4931 1/4\" (5/4\") Cable Glands
4941\" Cable Glands
4951/2\" Cable Glands
496Supply of Plugs - flame proof and weather proof including EP/WP certificates:
4975/4\" Plugs
4981\" Plugs
4991/2\" Plugs
500Supply of Reducers - flame proof and weather proof including EP/WP certificates:
5011\" to 1/2\" Reducers
5021\" to 3/4\" Reducers
5033/4\" to 1/2\" Reducers
504Supply and placing in position 5 mm thick steel checkered plates over cable ducts, valves, pits etc including keeping provision of h oles for lifting arrangement and providing lifting arrangement complete in all respect inclusive of cost of all labour, material, ca rriage etc as per specification & the direction of the engineer in-charge/site engineer
505Supply of 8IN, 600 # Series -Short Neck Scrapper Detector Switch- As per Tender Specification
506Supply of Jacking Bracket for 600# Scrapper Detector
507Supply of Field Fittings & SS Tubes.-Non-Coastal Application - As per tender Specification
508Supply of Process Tube, Material: Stainless Steel, Manufacturing process: Seamless, Mat Specification:ASTM A269, Grade: TP316, end F inish: Plain End, 1/2 IN OD, 0.065 IN Thickness, 3000 MM Length.
509Supply of Fitting, Bushing, 25.4 MM X 12.7 MM NPT(F), Material: Carbon Steel, Manufacturing Process: Forged, Material Specification:A105, End Finish: Threaded, conform to ANSI 16.11
510Supply of Male Connector, 12.7 MM MNPTX 12.7 MM OD Tube, Material: SS316, 211 kg/sqcm (3000 psi) complete with ferrules & nuts as pe r ANSI B.2.1.
511Supply of Female Connector, 12.7 MM FNPT X 12.7 MM OD Tube, 211 kg/sqcm (3000 lbs) complete with ferrules and nut as per ANSI B.2.1,Material : SS316.
512Supply of FITTINGS Union Tee, 3X12.7 MM OD Tube, 211 kg/sqcm (3000 lbs) as per ANSI 16.11, Material : SS316
513Supply of FITTINGS 2 Way Valve Manifold 2 x 12.7 MM FNPT, Material : SS316 with blanking plug for each port.
5141/2\" OD SS Tube End cap as per tender specifications
515Hex nipple 12.7 MM MNPT X 12.7 MM MNPT X 80 MM Long
5162 Service
517As built documentation for all stations i.e. Sankari, Irugur, SV locations covering a) Control /signalling cable layout drawings, b) Cable trench details, c) Cable marker details, d) Earth grid layout, e) Field instrument termination details, f) Cable schedule, g) Junction box wiring details, h) Earth resistivity measurement data, i) Field panel termination details, j) Calibration data of all instruments tested as per scope, k) OTDR Traces of the laid OFC.
5183 Composite
519Installation, testing and commissioning ofPressure Indicator (PI) of various ratings as per directions of Engineer in-charge/ Site engineer and Drawings
520Taking delivery, shifting within a road distance of 500 meters and installation & testing of the following instruments (pressure Gauge, Pressure Switch, Pressure Transmitter, flow meters, density meters etc. of various ratings by fabrication and installing all the required pipe fittings with pressure pipes, valves, plugs, tees, nipples, junction box, cables, supply and erection of all other required materials such as the supporting structure clamps, cannopy, screws, nuts, bolts, aluminium sheets, GI wire, steel plats, cement concrete etc. complete in all respects including supply of suitable size non flame proof cable gland at control panel end and terminating the already laid cables at field, junctionbox and control panel end, mounting the junction boxes as per the Drawings, specifications and directions of the engineer in-charge/site engineer including cost of all labour, materials, consumables, tools, tackles and services rendered etc. All the instruments shall have to be properly connectedto the earth pit through GI wires. The works shall include labelling, tagging using SS plates, glanding and ferruling at both field and panel side. Installation to be done as perOEMs recommendations, vendor drawings and other approved drawings. The scope shall include providing assistance in testing and commissioning of the instruments along with loop checking and providing assistance to control system vendor
521INSTALLATION OF PI+PS/PT: Installation, assistance in testing and commissioning of Pressure gauges and Pressure switches (PI+PS) / Pressure Gauge and Pressure Transmitter (PI+PT) of various ratings as per the directions of Engineer-in-charge/ Site engineer and drawings.
522INSTALLATION OF PT / PS: Installation, assistance in testing and commissioning of Pressure Transmitter (PT) / Pressure Switch (PS) of various ratings as per the directions of Engineer in-charge/ Site engineer anddrawings.
523INSTALLATION OF TEMPERATURE TRANSMITTER: Installation and assistance in testing & commissioning of temperature elements/temperature transmitter(TT) by making necessaryholes on the pipes, welding the socket for thermowell on the pipe including supply of boss, silicon paste etc as per the directions of engineer in-charge/site engineer and drawings.
524INSTALLATION OF SURFACE MOUNTED TEMPERATURE TRANSMITTER: Installation and assistance in testing & commissioning of temperature elements/temperature transmitter(TT) by welding the weld pad on the surface of the pipe, silicon paste etc as per the directions of engineer in-charge/site engineer and drawings.
525INSTALLATION OF EMERGENCY SHUTDOWN SWITCH/ MANUAL CALL POINT: Installation and testing of emergency shut - down (ESD) Push button/ Manual Call Point. This includes mounting of termination box as per the drawings, specification and instruction of Engineer in-charge/ Site engineer, replacement of broken glass covers and painting it in red colour.
526INSTALLATION OF SCRAPPER DETECTOR: Installation, assistance in testing and commissioning of Scrapper Detector of various ratings as per OEM recommendations, vendor drawings, directions of engineer in-charge/site engineer andother approved drawings.
527Installation ofexplosion proof/flame proof junction boxes, non-flame proof junctionbox for marshalling of control cables, terminating the cables at field and control panel end, mounting the junction boxes, connecting to earthing grid by supplying and installing all the required materials such as supporting structure, cement concrete, painting, GI wire etc. (excluding supply of the Junction Boxes) in all respects complete as per specifications, drawings and direction of site Engineer including supply of suitable size non-flame proof cable glands at Control Panel end and the cost of labour, tools, materials, glanding, ferruling etc. complete in all respects.
528Carrying out the instrumentation and control system jobs on the already erected actuator assembly of motor operated valves (MOVs) & Remote Operated Valves (ROVs) by making the instrument air connection (in ROVs) & necessary cable connection at field and control panel end (excluding the supplyof cables) calibrating the control components, adjusting the limit switches, testing the whole assembly as per drawings specifications and direction of the engineer in-charge/site engineer complete in all respect, including supply of suitable size non-flame-proof cable glands, ferruls, drilling/cutting of plate for fixing glands at Control Panel end and the cost of all labour, tools, glanding, ferruling, consumables etc.
529INSTALLATIONOF CONTROL PANEL/ CONSOLE DESK/ UPS/ RIO/ RTU/ PLC/ ACDB: Taking delivery, shifting the panels to installation site and erection, installation, testing of Control panels/ RTU panel, mounted with all the instruments, power supply units, UPS & battery banks logic control systems , barriers, providing assistance to control system vendor for commissioning of control system including panels, control desk etc. installation on already made foundations or fixing on walls, or steel structure or fixtures aligning, levelling, grouting, inter-wiring outgoing, incoming cable terminations as required, earthing, testing, complete in all respects as per drawings, specifications and directions of the engineer in-charge/site engineer, including supply of suitable size non-flame proof cable glands for all incoming/outgoing cables and the cost of the materials, tools, labour, glanding, ferruling etc. complete in all respects.The indicated quantity iscumulative weight of panels.
530AIR CONDITIONERS - CASSETTE TYPE : Supply& Installation of 1.8TCassette Type ACs flushed with false ceiling (Daiken / Hitachi / Carrier) along with 5KVA Voltage Stablizer & MS stand for outdoor unit, refregerant piping, drain piping complete as per instruction of EIC / Site Engineer.
531INSTALLATION OF MANUAL CALL POINT (EXPLOSION PROOF & WEATHER PROOF): Installation of Manual Call Point (Explosion Proof & Weather Proof) in Hazardous area, terminating the cables at field and control panel end, connecting to earthing grid by supplying and installing all the required material such as supporting structure, cement concrete, painting, GI wire etc. (excluding supply of the Manual Call Point) complete in all respects as per specifications.
532INSTRUMENTATION JOBS FOR HOV Carrying out the instrumentation and control system jobs on the already erected actuator assembly of hand operated valves (HOV) by making the necessary cable connection at field and control panel end (excluding the supplyof cables) calibrating the control components, adjusting the limit switches, testing the whole assembly as per drawings specifications and direction of the engineer in-charge/site engineer complete in all respect, including supply of suitable size non-flame-proof cable glands, ferruls, drilling/cutting of plate for fixing glands at Control Panel end and the cost of all labour, tools, glanding, ferruling, consumables etc.
533INSTALLATION OF INFRARED HYDROCARBON DETECTORS (POINT TYPE / OPEN PATH TYPE): Terminating the cables at field and control panel / RTU end, connecting to earthing grid by supplying and installing all the required materials such as supporting structure, canopy, cement concrete, painting, GI wire etc.(excluding supply of the Hydrocarbon detector) complete in all respectsas per specifications.
534INSTALLATIONJOBS for Metering SKID Carrying out the instrumentation and control system job on the already erected Metering skid & necessary cable termination in the skid junction boxes at field end and control panel end (excluding the supplyof cables) as per drawings specifications and direction of the engineer in-charge/site engineer complete in all respect, including supply of suitable size non-flame-proof cable glands, ferruls, drilling/cutting of plate for fixing glands at Control Panel end and the cost of all labour, tools, glanding, ferruling, consumables etc.
535AIR CONDITIONERS - SPLIT TYPE Supply& Installation of 1.8TSplit Type five star BEE rated ACsalong with 5KVA Voltage Stablizer & MS stand for outdoor unit, refregerant piping, drain piping complete as per instruction of EIC / Site Engineer
536MAGNETIC PROXIMITY SWITCH Supply & installation of MAGNETIC PROXIMITY SWITCH with suitable junction box for termination of leads/cable for extending contact to control system for unauthorised entry of building / MOV fencing.
537CSW - Mechanical Services
538Taking delivery of equipments from designated stores/stockyard,shifting / transporting to station premises, placing on pre-constructed foundations, assembling together all sub-assemblies, levelling, alignment, grouting, cleaning and flushing by water/ nitrogen as applicable, draining, checking, testing with Nitrogen, dressing and making good of the foundation and completing the work in allrespects in accordance with the relevant drawings, manufacturer\"s installation instructions, specifications and instructions of Site Engineer / EIC. Note: Weight of equipment is indicative only, Payment shall be done based on actual weight of equipment, as applicable
539SCRAPER BARREL
5408\" x 12\" 600# Scrapper Barrel
541INSULATING COUPLING
5428\" x 600# Insulating Coupling
5434\" x 600# Insulating Coupling
544FILTRATION/METERING/PRS SKID
545FLOW TEE
5468\" x 600# Flow tee (Equal) - AG
547UNDER GROUND EQUIPMENT INSTALLATION
548FLOW TEE
5498\" x 4\" x 600# Flow Tee (Unequal) -UG
550Taking delivery & transporting of pipes from designated stock pile location /Designated godown both from outside & inside station premises. Taking delivery of pipe fittings, steel flanges, spiral wound metallicgaskets & fasteners, insulating gaskets, etc. from designated location within station premises/ stockyard/ store, transporting the same to site, fabrication and erection of above ground piping including cutting,edge preparation, bending, threading, lining up, welding and intsalling pipes and pipe fittings, flanges,elbows, equal and reducing outlet tees, concentric/eccentric reducers, y-type strainers, drain funnels, vent pipes and tapping for instruments such as pressure gauges, thermal relief valves, pressure safety valves, thermowells etc.,installing abovegroundatallelevations connectingwith equipment nozzles, valves, vessels, in line instruments etc., welded and threaded pipe line of different pressure ratings, flushing pipes by water after cleaning by compressed air, cleaning by card board blasting, hydrostatic testing of each section by water to the specified pressure and carrying out low pressure pneumatic testing at specified pressure, draining the water and drying the piping with nitrogen, draining the water, tie-in, final cleaning-up and dispoal of wastes and surpluses including providing all inputs such as labour, material, equipments and consumables necessary to perform the work (other than those specifically under taken by the owner in this contract) and completing the work in all respects in accordance with the drawings, specifications and instructions of Site Engineer / EIC. Note: Thickness and Grade mentioned in the item are for reference only and may vary. Payment shall be based on OD.
551PROCESS PIPING
5528 NPS API 5L/ ASTM A106/ A333 Pipe
5536 NPS API 5L/ ASTM A106/ A333/ A53 Pipe
5544 NPS ASTM A106/ A333/ A53 Pipe
5553 NPS ASTM A106/ A333/ A53 Pipe
5562 NPS ASTM A106/ A333/ A53 Pipe
5571 NPS ASTM A106/ A333/ A53 Pipe
5583/4 NPS ASTM A106/ A333/ A53 Pipe
559Taking delivery of pipes (bare/3LPE coated), pipe fittings, steel flanges, spiral wound metallic gaskets & fasteners from designated location within station premises/stockyard/stores transporting the same to site, fabrication and erection of underground piping including cutting, edge preparation, bending, threading, lining up and welding, excavating, trenching in all kind of soil to specific depths as indicated in drawings and installing pipes and all types of pipe fittings like flanges, elbows, equal and reducing outlet tees, concentric/eccentric reducers, drain funnels, vent pipe and tapping for instrument such as pessure gauges, thermal relief valves, pressure safety valves, thermowells etc., underground at elevations indicated in the drawing connecting with equipment nozzles, valves, vessels, in-line instruments etc., cleaning the material surface by sandblast or with power wire brush (wherever sand blast cleaning is not possible) free of dust, grease, mill scales etc., and applying single layer polyurethane coating(PU) using 100% solvent free elastomeric plyurethane/ liquid epoxy, with approved materials,Equipment etc, holiday detection of the coating, cleaning of coated pipes by water flushing after cleaning by compresed air, cleaning by card board blasting, hydrostatic testing of each section by water to the specified pressure and carrying out low pressure pneumatic testing at specified pressure, draining the water and drying the piping with nitrogen, draining the water, tie-in, back filling, restoration of site final cleaning up and disposal of water and surpluses, providing all inputs such as labour, materials equipment and consumable necessary to perform the work (other than those specifically undertakento be supplied by the owner under the contract) and completing the work in all respects in accordance with the drawings, specifications and instructions of the Site Engineer / EIC.In case of 3LPE coated pipes, weld joints shall be PU coated. Note: 1. Thickness and Grade mentioned in the item are for reference only and may vary. Payment shall be based on OD. 2. Payment for external PU/ epoxy coating shall be done separately as per relevant SOR item.
560PROCESS PIPING
5618 NPS API 5L/ ASTM A106/ A333 Pipe
5626 NPS API 5L/ ASTM A106/ A333/ A53 Pipe
5634 NPS ASTM A106/ A333/ A53 Pipe
5643 NPS ASTM A106/ A333/ A53 Pipe
5652 NPS ASTM A106/ A333/ A53 Pipe
5661 NPS ASTM A106/ A333/ A53 Pipe
5673/4 NPS ASTM A106/ A333/ A53 Pipe
568Taking delivery of valves of all types and pressure rating from the designated location within station premises, transporting the same to site, carrying out pre-hydrotesting of valve and seat test of valve before installation of valve at specified pressure as per instruction of EIC, erecting above ground on preconstructed foundations or underground including earth work in excavation and filling for under ground valves at elevations specified in the drawings, priming and painting of above ground valves, flood coating and wrapping of under ground portions (if applicable) including all inputs, labour, material and consumable (other than those specifically undertaken to be supplied by the owner) and completing the work in all respects in accordance with the drawings, manufacturer\"s installation instructions and specifications and instructions of the Site Engineer / EIC. Note: Payment for conctruction of foundations shall be done seprately as per relevant SOR item.
569API 6D Ball Valves - Gas Over Oil Actuated
5708\"x ANSI 600# fully welded W/W, U/G, API
5718\"x ANSI 600# fully welded W/W, A/G, API
572API 6D Ball Valves -Lever /Gear Operated
5738\"x ANSI 600#, Bolted F/F, A/G, Gear ope
5746\"x ANSI 600#, Bolted F/F, A/G, Gear ope
5754\"x ANSI 600#, Bolted F/F, A/G, Gear ope
5763\"x ANSI 600#, Bolted F/F, A/G, Gear ope
5772\"x ANSI 600#, Bolted F/F, A/G, Gear ope
5788\"x ANSI 600#, fully welded, W/W, A/G, G
5794\"x ANSI 600#, fully welded, W/W, A/G, G
5802\"x ANSI 600#, fully welded, W/W, A/G, l
5814\"x ANSI 600#, fully welded, W/W, U/G, G
582BS 5351 / ISO 17292 Ball Valve / BS 1873 / API 623 / ISO 15761 Globe Valve
5831\"x ANSI 800# HOV W/W BS 5351 / ISO 1729
5843/4\"x ANSI 800# HOV W/W BS 5351 Ball / I
5854\"x ANSI 600# F/F BS 1873 /API 623 Globe
5862\"x ANSI 600# F/F BS 1873 /API 623 Globe
5871\"x ANSI 800# W/W BS 1873 / API 623 / ISO 15761 Globe Valve
588PRESSURE SAFETY VALVE
5891\" X 2\"x ANSI 600# x150# F/F PSV
590Inspection of welding by Digital Radiography (CR) or by conventional film radiographic method on all types of piping including processing of images/films and interpreting the results of weld quality and reporting the same to the Site Engineer together with recommendations as to the acceptability or otherwise of the welds, submitting the finished radiographic films / images as may be approved or directed by Engineer-in-Charge inclusive of supply of all pesonnel, labour, materials, equipment, consumable, inputs, etc. and providing all services complete in all respects as envisaged in the contract documents. Note: i)Payment will be on the basis of number of welds of the respective size radiographed and shall be all inclusive for the complete job of radiographic inspection as envisaged in the contract document. ii)Radiography not involving full girth weld will be paid at 50% of the rate for full girth weld for the respective size. iii)For set-on type branch welding, the rate for radiography will be as applicable to the branch pipe size. iv)Repeat radiography of individual welds due to defective films or repair of welds shall be done at contractor\"s cost. In case where radiography is not possible: v) Verification by utrasonic testing shall be done at contractors cost. vi) Magenetic particle inspection as and where required shall be done at Contractors cost. vii) In case of conventional film radiography, all films shall be digitised and submitted to EIC/ Site Engineer in USB drives. viii) In case of Digital/ Computed Radiography, native files along with image/ pdf files shall be submitted to EIC/ Site Engineer in USB drives.
5918\" NBPipe Joints
5926\" NBPipe Joints
5934\" NBPipe Joints
5943\" NBPipe Joints
5952\" NBPipe Joints
5961\" NBPipe Joints
5973/4\" NBPipe Joints
598Cutting (Hot/ Cold cutting) of portion of existing piping, trimming, grinding, bevelling the edges, aligning without addition of spool piece, welding the joint including supply of all inputs such as labour, materials, equipment, consumables etc. necessary to perform and complete the work in all respect as per specification and instruction of the Site Engineer / EIC. Note: The job also include evacuation of product from the piping section after isolating the section and flushing with water and its disposal.
5998\" OD
6006\" OD
6014\" OD
6023\" OD
6032\" OD
604Cutting (Hot/ Cold cutting) of portion of existing piping upto and including a length of 500 mm, trimming, grinding, bevelling the edges, adding spool piece of required length / tee and the corresponding pipe size, thickness, adjoining and welding both the ends including supply of all inputs such as labour, materials, equipment, consumables etc. necessary to perform and complete the work in all respect as per specification and instruction of the Site Engineer / EIC. Note: The job also include evacuation of product from the piping section after isolating the section and flushing with water and its disposal.
6058\" OD
6066\" OD
6074\" OD
6083\" OD
6092\" OD
610Dismantling by opening joints or by gas cutting/ cold cutting (wherever required as per site condition) of existing steel structural such as support for pipes, pipe fittings, valves, plate forms, walkways, stairways etc. including excavation work wherever required handling, loading into truck for purpose of weighing, shifting to the designated location within the pump station premises and handing over, completing the workin all respect as per drawings, instruction of the Site Engineer / EIC.
611Dismantling of existing over ground piping works of all types and sizes by opening flange joints or by gas cutting/ cold cutting or any other approved suitable means without damaging other portions of work.The job includes cutting the pipes to required sizes as directed, taking out valves, flanges, tees, bends, gaskets nuts, bolts etc. attached supports alongwith any instruments such as pressure gauge, temperature gauge etc. handling, transporting and storing at owner\"s designated store in safe manner to avoid damage including supply of all labour, materials, equipments, consumables etc. necessary to perform and complete the work in all respects as per drawings, instructions of the Site Engineer/ EIC (payment shall be made on linear measurement of dismantled piping including bends tees etc.).Note : The contractor shall indicate the piping system to be dismantled and shall take specific approval from the Site engineer before dismantling of pipe. Certain redundant pipes which in the opinion of the Owner need not be retrieived, those items shall not be dismantelled.
612Dismantling the existing under ground piping, locating, retrieving including excavating the proper trenches by cutting the pipes without damaging other portions of work.The job includes cutting the pipes to required sizes as directed, taking out valves, flanges, tees, bends, gaskets, nuts, bolts etc., handling, transporting and storing at owner\"s designated store in safe manner to avoid damage including supply of all labour, materials, equipment consumables etc. necessary to perform and complete the work in all respects as per drawing, instructions of the Site Engineer / EIC. (Payment shall be made on the linear measurement of dismantled piping including bend, tees, reducers etc.).Note : The contractor shall indicate the piping system to be dismantled and shall take specific approval from the Site engineer before dismantling of pipe.Certain redundant pipes which in the opinion of the Owner need not be retrieived, those items shall not be dismantled.
613Development of As Built Drawings, Data Sheets etc.: Development of as built drawings, data sheets, system details covering all additional facilities incorporated under this project in the station and furnishing them as reference document. Additionally, electronic copy of the documents shall also be furnished in compact disks- For all Stations
614Providing services assistance during pre-commissioning and commissioning of entire SV station piping with or without tap-off/with or without scraper barrel including supply of required amount of nitrogen gas at required pressure, tools and tackles, cranes, skilled and semi-skilled manpower, consumables, etc as per instruction of Engineer-In-charge
615Providing services assistance during pre-commissioning and commissioning of scraper barrel, Knock out drums, filters, metering skid, pressure reduction skids as applicable for entire IP station piping including supply of required amount of nitrogen gas at required pressure, tools and tackles, cranes, skilled and semi-skilled manpower, consumables, etc as per instruction of Engineer-In-charge
616Flexibility and Piping Stress Analysis as per specification
617Installation of Corrosion Coupon including welding of TOR fitting complete with Coupon holder, Caps, Plugs, O-Rings, Nipple & installation of 2\" 600# fullbore threaded ball valve.
618CSW - Mechanical Composite
619Supplying at site, steel structural items such as steel plates, bars, MS gratings, chequered plates, angles, beams channels, commercial quality heavy pipes, C.I. Rollers, bolts & nuts, washers, grouting bolts, padding plates etc., fabrication and erection of saddle supports and other type of supports for pipes manifolds and valves, fabrication and erection of platforms walkways, stairways etc., sand blast/ power brush cleaning, priming and painting the finished structures including supply of all other inputs such as labour, materials, consumable etc. necessary to perform and complete the work in all respect, in accordance with drawings, specifications and instructions of the Site Engineer / EIC.
620Supplying at site, steel structural items such as steel plates, bars, fabrication of gratings by electroforged method,after complete fabrication entire gratings shall be Hot Dip galvanized, gratings shall be normany of size 810mm X 250mm for steps and 1200mm X 1000 mm or 810mm X 1000 mm for platforms / walkways, or any size as advised by EIC. Placing gratings in a replaceable mannerbolting with base frame of ISA by suitable GI clamps and GI fasteners, including supply of all other inputs such as labour, materials, consumable etc. necessary to perform and complete the work in all respect, in accordance with drawings, specifications and instructions of the Site Engineer / EIC.
621Cleaning exposed steel surfaces of piping, equipment and valves etc. by sand blasting or with power wire brush (wherever sand blast cleaning is not possible) free of dust, grease, mill scales etc.and applying single layer polyurethane coating(PU) using 100% solvent free elastomeric plyurethane/ liquid epoxy, with approved materials, labour, equipment etc. and completing the job in all respects as per specification and instructions of the Site Engineer / EIC.
622Surface preparation of piping, equipment and valves etc. by abrasive blast cleaning or with power wire brush (wherever blast cleaning is not possible) confirming to SA 2.5, making the surface free of dust, grease, mill scales etc., application of 1 coat x 50-75 microns DFT ofInorganic Zinc Ethyl Slicate Primer, followed by application of sealer coat of 30 micron DFT and intermediate coat of 150 micron DFT with surface tolerant epoxy mastic paint and 2 coats x 50 micron each DFT of Isocynate Aliphatic Poly Urethene (PU) by airless spray, with approved materials, paints, tools, tackles, consulambles, non-consumables, labour, equipment etc. to complete the job in all respects as per specification and instructions of the Site Engineer / EIC. The total DFT shall be minimum 330 microns.
623Copper Strips/ Flats for Jumpers for Flanged Joints of the Product Process Piping: Supply and Installation of one copper jumper per flanged joint across the flanged joints for valves, spool piece, branch offs etc., of product process piping,The job includes cutting drilling of holes of required size in the copper strips/ flats for bolting purpose and complete the works in all respects as per specifications & drawings and instructions of Site Engineer/ EIC.Note:- Copper jumpers shall be installed in all the flanged joints of Product Process piping only and not in fire water lines.
624Up to 30 mm wide x 3 mm thick Copper str
625\"Hot-tapping works on 8\"\" 600# line size with double-double stopple and tempoprary bypass line: Mobilization of Equipments, Hot Tapping, stopple machine, sandwich valves, welding machine& consumables, cutter housing, stopple housing, stopple head, stopple cutter, pilot drill, cutter holder, Lock O-Ring plus plugs, LOR plus plug holder, required skilled, semiskilled, unskilled manpower,includungSupply and Delivery ofhot tap & Line stopple fittings, Line Stopple Plug with scarfed nipple / Lock O-Ring plus plugs,Hot Tap by-pass fitting,Hot Tap Plug with Scarfed Nipple/Lock O-Ring, Buna N Sealing Elements,pressure equalization fittings, Lock O-Ring plus plugs, Sealing elements, guide bar, Blind Flanges, other tools, fixtures of required pressure rating for 2 nos. hot tap, all accessories, gaskets, fasteners etc. required to complete the job, inline with enclosed Drawing, cleaning and removal of the coating if required, Installation of the cutter housing, carrying out Hot tapping, fabrication and creation of temporary housing to housing bypass line of same size or one size lower pipe along with sandwich isolating valve at each end, stoppling, welding, radiography of weld joint etc. providing all assistance for Hot tapping, N2 testing ,insertion of the stopple plug and blocking flow in the pipeline section, Fabrication and laying of bypass line,installation of gas bags, installation ofLOR plus plug, testing, air bleeding and filling the section with product, Clearing the area,machines, tools & tackles etc., completing the work in all respect with all materials, consumables, tools, tackles, labour etc. to restore normal operation in line with specification of hot tapping given including all material complete under close supervision and as per the direction of the Site-Engineer / Engineer-in-charge. The rates are inclusive of all manpower, equipent, tools & tackles, consumable etc required to complete the job as per scope of work. The rates are exclusive of cold cutting of mainline & hookup work work which are included in the scope of service contractor as per scope of work.\"
626CSW - Mechanical Supply
627Supply and delivery of Spiral Wound Metallic Gaskets as per technical specifications from approved vendors specified in tender document.
628150#
6294\" SWMG ANSI 150#
6302\" SWMG ANSI 150#
6311\" SWMG ANSI 150#
632600#
6338\" SWMG ANSI 600#
6346\" SWMG ANSI 600#
6354\" SWMG ANSI 600#
6363\" SWMGANSI 600#
6372\" SWMG ANSI 600#
6381\" SWMG ANSI 600#
6393/4\" SWMG ANSI 600#
640Supply and delivery of Insulating Gaskets as per technical specifications from approved vendors specified in tender document:
6412\" ANSI 600#
642Supply and delivery of Steel Fasteners as per technical specifications from approved vendors specified in tender document:
643150#
644Fasteners forFlanges 4\" x 150# (0.625\" Dia. X 4.00\" Length)
645Fasteners forFlanges 2\" x 150# (0.625\" Dia. X 4.00\" Length)
646Fasteners forFlanges 1\" x 150# (0.500\" Dia. X 3.00\" Length )
647600#
648Fasteners forFlanges 8\" x 600#(1.125\" Dia. X 9.75\" Length ) - extended stud length for flanges with spectacle blind
649Fasteners forFlanges 8\" x 600#(1.125\" Dia. X 8.25\" Length )
650Fasteners forFlanges 6\" x 600#(1.0\" Dia. X 9.0\" Length)- extended stud length for flanges with spectacle blind
651Fasteners forFlanges 6\" x 600#(1.0\" Dia. X 7.5\" Length)
652Fasteners forFlanges 4\" x 600#( 0.875\" Dia. X 7.75\" Length ) - extended stud length for flanges with spectacle blind
653Fasteners forFlanges 4\" x 600#( 0.875\" Dia. X 6.50\" Length )
654Fasteners forFlanges 3\" x 600#( 0.75\" Dia. X 6.50\" Length )- extended stud length for flanges with spectacle blind
655Fasteners forFlanges 3\" x 600#( 0.75\" Dia. X 5.50\" Length )
656Fasteners forFlanges 2\" x 600#( 0.625\" Dia. X 5.75\" Length ) - extended stud length for flanges with spectacle blind
657Fasteners forFlanges 2\" x 600#( 0.625\" Dia. X 4.75\" Length)
658Fasteners forFlanges 1\" x 600#(0.625\" Dia. X 5.0\" Length )- extended stud length for flanges with spectacle blind
659Fasteners forFlanges 1\" x 600#(0.625\" Dia. X 4.0\" Length )
660Fasteners forFlanges 3/4\" x 600#(0.625\" Dia. X 4.0\" Length )
661Supply and delivery of Steel Flanges as per technical specifications from approved vendors specified in tender document:
662WNRF-150#
6634\", WNRF FLANGE, ANSI - 150# (B 16.5) - ASTM A350 Gr.LF2
6642\", WNRF FLANGE, ANSI - 150# (B 16.5) - ASTM A350 Gr.LF2
6651\", WNRF FLANGE, ANSI - 150# (B 16.5) - ASTM A350 Gr.LF2
666WNRF-600#
6678\", WNRF FLANGE, ANSI - 600# (B 16.5)-ASTM A694 GR. F-60 /65 /70 -ASME16.5
6686\", WNRF FLANGE, ANSI - 600# (B 16.5)- ASTM A 105-ASME16.5
6694\", WNRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2 Cl 1-ASME16.5
6703\", WNRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2 Cl 1-ASME16.5
6712\", WNRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2 Cl 1-ASME16.5
6721\", WNRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2 Cl 1-ASME16.5
6733/4\", WNRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2 Cl 1-ASME16.5
674BLRF-150#
6754\", BLRF FLANGE, ANSI - 150# (B 16.5) - ASTM A350 Gr.LF2
6762\", BLRF FLANGE, ANSI - 150# (B 16.5) - ASTM A350 Gr.LF2
6771\", BLRF FLANGE, ANSI - 150# (B 16.5) - ASTM A350 Gr.LF2
678BLRF-600#
6798\", BLRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2 CL 1
6806\", BLRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2 CL 1
6814\", BLRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2 CL 1
6823\", BLRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2 CL 1
6832\", BLRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2 CL 1
6841\", BLRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2 CL 1
6853/4\", BLRF FLANGE, ANSI - 600# (B 16.5)-ASTM A350 LF2 CL 1
686Supply and delivery of Spectacle Blinds as per technical specifications from approved vendors specified in tender document:
687600#
6888\" 600# F/F R/F- ASTM A 105
6896\" 600# F/F R/F - ASTM A 105
6904\" 600# F/F R/F- ASTM A350 LF2
6913\" 600# F/F R/F- ASTM A350 LF2
6922\" 600# F/F R/F- ASTM A350 LF2
6931\" 600# F/F R/F- ASTM A350 LF2
694Supply and delivery of valves for use in process piping as per technical specifications from approved vendors specified in tender document:
695API 6D Ball valve
6962\" W/W ANSI 600# A/G, API 6D BALL VALVE-ASTM A350 LF2/ASTM A352 LCC
6972\" F/F ANSI 600# A/G, API 6D BALL VALVE-ASTM A350 LF2/ASTM A352 LCC
698BS 5351 / ISO 17292 Ball valve
6991\" W/W ANSI 800# A/G, BALL VALVE- BS 5351-ASTM A350 LF2/ASTM A352 LCC
7003/4\" W/W ANSI 800# A/G, BALL VALVE-ASTM A350 LF2/ ASTM A352 LCC
701BS 1873 / API 623 /ISO 15761 Globe Valve
702600#
7034\"600#,F/F,A/G-ASTM A350LF2/ASTM A352LCC
7042\"600#,F/F,A/G-ASTM A350LF2/ASTM A352LCC
7051\", 800# W/W ASTM A350 LF2/ASTM A352 LCC
706PSV
7071\"x2\"x600# x150# PSV -ASTM A350 LF2/ASTM A352 LCC
708Supply and delivery of pipe fittingsas per technical specifications from approved vendors specified in tender document:
709Un Equal Tee
710600#
7118\"x6\"600#(Sch.80 x Sch.80)ASTM A420 WPL6
7128\"x4\"600#(Sch.80 x Sch.80)ASTM A420 WPL6
7138\"x3\"600#(Sch.80 x Sch.160)ASTM A420WPL6
7146\"x4\"600#(Sch.80 x Sch.80) ASTM A420WPL6
7156\"x3\"600#(Sch.80 x Sch.160)ASTM A420WPL6
7164\"x3\"600#(Sch.80 x Sch.160)ASTM A420WPL6
7174\"x2\"600#(Sch.80 x Sch.160)ASTM A420WPL6
7183\"x2\"600#(Sch.160xSch.160)ASTM A420WPL6
7192\"x1\"600#(Sch.160xSch.160)ASTM A420WPL6
7202\"x3/4\"600#(Sch.160xSch160)ASTM A420WPL6
721Equal Tee
722600#
7238\" 600#(Sch.80) -ASTM A420 Gr.WPL6
7246\" 600#(Sch.80) -ASTM A420 Gr.WPL6
7254\" 600# (Sch.80) -ASTM A420 Gr.WPL6
7263\" 600# (Sch.160) -ASTM A420 Gr.WPL6
7272\" 600# (Sch.160) -ASTM A420 Gr.WPL6
7281\" 600# (Sch.160) -ASTM A420 Gr.WPL6
7293/4\" 600#(Sch.160) -ASTM A420 Gr.WPL6
730Elbow-90 deg LR Bends
731600#
7328\" 600#(Sch.80) -ASTM A420 Gr.WPL6
7336\" 600# (Sch.80) -ASTM A420 Gr.WPL6
7344\" 600# (Sch.80) -ASTM A420 Gr.WPL6
7353\" 600# (Sch.160) -ASTM A420 Gr.WPL6
7362\" 600# (Sch.160) -ASTM A420 Gr.WPL6
7371\" 600# (Sch.160) -ASTM A420 Gr.WPL6
7383/4\" 600# (Sch.160) -ASTM A420 Gr.WPL6
739Elbow-45 deg LR Bends
740600#
7418\" 600# (Sch.80) -ASTM A420 Gr.WPL6
7426\" 600#(Sch.80) -ASTM A420 Gr.WPL6
7434\" 600# (Sch.80) -ASTM A420 Gr.WPL6
7443\" 600# (Sch.160) -ASTM A420 Gr.WPL6
7452\" 600# (Sch.160) -ASTM A420 Gr.WPL6
7461\" 600# (Sch.160) -ASTM A420 Gr.WPL6
7473/4\" 600# (Sch.160) -ASTM A420 Gr.WPL6
748Concentric Reducers
749600#
7508\"x6\" 600#(Sch.80XSch.80) ASTM A420 WPL6
7518\"x4\" 600#(Sch.80XSch.80)ASTM A420 WPL6
7526\"x4\" 600#(Sch.80XSch.80) ASTM A420 WPL6
7536\"x3\" 600#(Sch.80XSch.160)ASTM A420 WPL6
7544\"x3\" 600#(Sch.80XSch.160)ASTM A420 WPL6
7554\"x2\" 600#(Sch.80XSch.160)ASTM A420 WPL6
7563\"x2\"600#(Sch.160XSch.160)ASTM A420 WPL6
7572\"x1\"600#(Sch.160XSch.160)ASTM A420 WPL6
7582\"x3/4\"600#(Sch.160XSch160)ASTM A420WPL6
759Half coupling (Socolet) & Nipple
7601\" 6000# Nipple-ASTM A350 LF2 Cl.1
7613/4\" 6000# Nipple-ASTM A350 LF2 Cl.1
7621\"6000# HALF COUPLING -ASTM A350 LF2Cl1
7633/4\"6000# HALF COUPLING ASTM A350 LF2Cl1
764Weld-o-let
765600#
7668\"X2\" 600# (Sch.160) ASTM A350 LF2, CL1
7676\"X2\" 600# (Sch.160) ASTM A350 LF2, CL1
768Supply of API 5L/ ASTM A333 Gr.6 pipes as per technical specifications from approved vendors specified in tender document:
7696.625\"ODxSch.80 ASTM A 106 Gr B/333 Gr6
7704.50\" OD x Sch.80 ASTM A 333 Gr. 6
7713.5\" OD x Sch.80ASTM A 333 Gr. 6
7722.375\" OD x Sch.160 ASTM A 333 Gr. 6
7731.315\" OD x Sch.160 ASTM A 333 Gr. 6
7741.050\" OD x Sch.160 ASTM A 333 Gr. 6
775Supply and delivery of Fire Fighting Equipment as per techhnical specifications indicated in tender document:
7769 kgDCP Extinguisher- IS 15683 Marked
7774.5 kg CO2 Extinguisher- IS 15683 Marked
7782 kgCO2 Extinguisher- IS 15683 Marked
7792 kg clean agent extinguishers IS 15683 Marked
780Sand drum with scoop
781Pair of Rubber hand gloves for Electrical work bearing IS mark
782First Aid Box with Snake serum
783Fire Bucket
784Safety Helmet
785Strecher with blanket
786Explosimeter
787Portable oxygen LEL meter
788Rescuscitor
789Wind socks
790Red & Green flag (Pairs) 2 nos in each colour
791Extinguisher box for 9 kg DCP Extinguishers
792Dry Chemical Powder silliconised potasium bicarbonate type IS marked, pack of 10 KG
793CO2 cartridge - 200 gm capacity for 9 kg capacity DCP extinguisher
794Water gel blanket
795Positive Pressure type self containing Breathing Apparatus
796Fire Proximity suit
797PCV suit
798Ear plug
799Ear muff
800Loud hailer/ megaphone
801SafetyTorch
802Cotton hand gloves
803Low temparature rubber hand gloves
804Supply and delivery of Flame Arrestor as per technical specifications indicated in tender document:
8054\" Flame Arrester
806Corrosion Coupon: Supply of TOR Fitting Complete W/ Plug & Cap and Full bore Threaded Ball Valve
807TOR fitting complete with Caps, Plugs, O-Rings, Nipple & 2\" 600# full bore threaded ball valve.
808RETRACTABLE CORROSION COUPON HOLDER, 8\"
809Supply of Insulating Coupling as per technical specifications from approved vendors specified in tender document.
8108\" x 600# Insulating Coupling
811Supply of flow tee as per technical specifications from approved vendors specified in tender document.
8128\" x 600# Flow tee (Equal) - AG
8138\" x 4\" x 600# Flow Tee (Unequal) -UG
814CP-ITC
81540 ML CP Supply
816Supply of Solid State Diode Decoupling Device (min 5 kA @ 30 cycles) of approved make including required length of cable as per spec ifications
817Solid State Decoupling Device
818Supply of Surge Arrestors of approvedmake including required length of cable & as per specifications for protection of insulating couplings
819Spark Gap Surge Arrestor for above ground and under ground suitable for 100 kA lightening Impulse Current (10/350 micro s), rated sp ark over voltage <= 1.25 kV in flameproof weatherproof enclosure Ex d IIC,IP 66withconnecting cable (EXFS 100 KU of Dehn or eq .)
820Supply of Cathodic Protection unit of approved make, complete in all respects as given in the specification with all its accessoriesto ensure trouble free operation
821Automatic type Cathodic Protection Power Supply Module (CPPSM) cum Cathodic Protection Transformer Rectifier (CPTR) unit with 48 V D C & 230 V AC input and 25 V, 25 A DC output along with DC-DC converter & TRU with built in digital data logger having GSM mobile pho ne connectivity, SCADA linkage and data downloading facilities for data downloading/monitoring,complete as an intergral unit, as perspecifications and of approved make
822Supply of junction box of approved make as per specification detailed in the tender document complete with all connecting terminal &shunts, other fittings, DC bus, MS plate box, bakelite terminal board, cable termination bolts, painting etc.
823Flameproof & weatherproofAnode Junction Box of approved make
824Supply of Flameproof & weatherproof CJB with accessories for distribution of current among pipelines as per technical specification.
825Supply of wall mounted DC distribution board of approved make in IP-42 ingress protection for power supply to CP equipments as givenin technicalspecifications
826DC distribution board with one incomer, 100 A DP MCB& outgoing feeders 1x63A DP MCB & 2x32 A DP MCB
827Supply of XLPE insulated , PVC sheathed cable, 1100 V gradeconforming to IS: 7098 (P-1) as per specifications and approved make
828Copper Cable size 1cx35 sq. mm Armoured
829Copper Cable size 1cx25 sq.mm Armoured
830Copper Cable size 2cx6 sq.mm Armoured
831Copper Cable size 2cx25 sq.mm Armoured
832Supply ofCu- Cuso4PermanentHalf cell with minimum 10 m length of tail cable, as per specifications of approved make
833Supply ofCu- Cuso4portableHalf cell, as per specifications of approved make
83450 ML CP Services
835Installation of solid state decoupling device as per specifications including terminating the cables in the TLP box with cable lugs,sealing material, laying of cable, testing & commissioning of Zinc anodes etc. all complete with required material, excavation, bac kfilling etc. as per specification and directions of Site Engineer/ Engineer-in-Charge.
836Solid State Decoupling Device
837Installation of surge arrestors including terminating the cables, testing & commissioning of surge arrestors etc. all complete with required material as per specification and directions of Site Engineer / Engineer-in-Charge.
838Surge Diverter/Spark Gap Surge Arrestor
839Installation of Permanent half cells including connecting the cable in the TLP etc. with cable lugs, sealing material, laying of cab le, testing & commissioning of cell etc. all complete with required material, excavation, backfillingetc. as per specifications, r ecommendation of cell supplier and directions of Site Engineer / Engineer-in-Charge.
840Permanent half cell
841Conducting \" Coating-Resistance Survey\" for calculation of specific coating resistance of the pipeline in ohms.sq.m. along the entir e pipeline and submitting the report in hard as well as soft copy as per Specification / approved procedure and directions of Site E ngineer / Engineer-in-Charge.
842Coating Resistance Survey
843Conducting Close Interval Potential Logging Survey at an interval of 1 m over the buried line in the right of way including the costof all competent manpower, transportation and camping facilities etc. to their employees, materials, test instruments, equipments, consumables etc., required for the survey as per the standard specifications, and approved procedures identification of areas/locati ons where coating repair is required alongwith suggestion for remedial measures etc. including the submission of draft reports in 2 sets and incorporation of owner\"s comments in the draft report and final reports in 3 sets including one soft copy containing the su rvey results in the graphical as well as tabular forms computerised colour print and complete in all respects and directions of SiteEngineer / Engineer-in-Charge.
844Close Interval ON/OFF Potential logging survey
845Close Interval Natural Potential Logging Survey
846\"Conducting Direct Current Voltage Gradient Survey over the buried line, logging all measurements,to identify / pin point the coat ing defects on pipeline including the cost of all competent manpower, transportation and camping facilities etc. to their employees,materials, test instruments, equipments, consumables etc., required for the survey as per the standard specifications and approved procedures, identification of areas/locations where coating repair is required alongwith suggestion for remedial measures etc. inclu ding the submission of draft reports in 2 sets and incorporation of owner\"s comments in the draft report and final reports in 3 setsincluding one soft copy containing the survey results in the graphical as well as tabular forms computerised colour print and compl ete in all respects as per directions of Site Engineer / Engineer-in-Charge. Note : The item includes establishing the coating defect at specified locations by excavation in coordination with mainline contract or, who will arrange to repair the defects.\"
847Direct Current Voltage Gradient Survey
848Conducting \"Soil Resistivity Survey\" at anode bed location after ascertaining its suitablity with respect to the existing system , f or installation of Anode Bed (deep / shallow / distributed), as per the specification, approved procedures and instructions of Site Engineer / Engineer-in-Charge.
849Soil Resitivity Survey
850\"Conducting AC interference survey, to detect presence of any AC voltage(induced owing to proximity of any HT transmission line (33 KV and above) crossing or running parallel within a distance of 60 M from thepipeline alignment as per approved procedure. The wor k shall be completed in all respects including survey, data logging for specified period, recommending mitigation measures & post mi tigation survey. The work includes all tools, tackles, consumables etc. all complete, required for survey / test as deemed necessaryand as per the directions of the site engineer / Engineer-in-Charge. Note : AC interference survey shall be done at respective TLP by connecting data logger to maintain record for minimum 24 hours. Thedata to be submitted for each such TLP alongwith coloured graph and recommendations.\"
851AC interference survey
852Conducting Mututal Interference Survey among the new and existing pipelines / facilities /foreign pipeline by taking PSP survey of a ll the pipelines as per approved procedure todetermine level of interference at different places along the pipelineand at point of crossing in common ROW including identifying points andproviding the data/ record in graphical form and carrying out all necess ary work for mitigating the interference observed among the pipelines , including retesting the same to ensure efficacy of the remed ial measures undertaken.The contractor shall submit a full final report with detailed PSP readings at all TLPs along with graphsin3 sets.The item should be complete in all respect including survey, work for mitigating the interference and post mitigating surveyas per specifications/directions of site engineer / Engineer-in-Charge.
853Mutual Interference Survey
854Carrying out the Current Attenuation(CAT) Survey at 50 meters interval by measuring current loss along the mainline pipe and using R adio Detection Instruments. Completing the entire work as per specification and EIC`s direction including all equipments with its ac cessories etc.tools, tackles, Battery transportation (Vehicle), related equipments,consumables, if any labour /manpower and any / al l relevant data collection as may be deemed necessary for carrying out the survey and interpretation /presentation of the results in cluding submission of reports complete in all respect thereof. Also locating the exact position of buried pipeline/defect of Pipelin e coating.Route mapping of the entire stretch at an interval of 10M with the help of GPS instrument (to be arrange by contractor)andsubmission of the hard and soft copy to the EIC.
855\"Cathodic Protection Units : Erection, testing and commissioning of cathodic protection units (CPTR/CPPSM); including supply and installation of all facilities, materials etc., including fuses, all supporting structures, laying and connecting the 1100 V Grade power cable (2 runs of 1Cx25 sqmmCu. conductor XLPE insulated Armoured Cable) from DCDB to CPPSM unit / laying and connecting the 1100 V Grade power cable (owner pr ovided 1 run of 3Cx10 sqmm Al. conductor XLPE insulated Armoured Cable) from ACDB to CPTR unit or both as required,providing earth ing arrangement. The work includes furnishing the test results by conducting all the NO LOAD and ON LOAD tests on the CP units and a djusting settings as required and testing the pipeline section for full cathodic protection for entire stretch. The job complete in all respect shall include costof all labour, tools as per specifications and directions of the Site Engineer / Engineer-in-Charge. \"
856230V AC cum 48 V DC Operated automatic type Cathodic Protection Power Supply Module (CPTR cum CPPSM) unit of rating 25 V, 25 A DC wi th with DC-DC converter & SCADA linkage facility as per specifications
857Installation of CJB / AJBas per technical specifications.
858Installation and commissioning of wall mounted DCDB including supply of all cable end lugs, cable glands, fittings & fixtures and al l other required accessories, tools and tackles complete in all respects as per directions of Site Engineer/Engineer-in-charge. Itemincludes supply and termination of 2 runs of 1cx25 sq. mm copper cable for Battery Bank
859DC distribution board
860Measuring, recording and submitting the cathodic protection readings along the entire pipeline by repeated adjustments of the settin gs of the CPTR/CPPSM units etcas per specifications for achieving full/maximum protection of all the stretches as per the criteriaof protection mentioned in the specifications. Measuring the relevant readings at the cathodic protection stations and \"pipe to soi l potential\" readings at all the test lead locations along the pipelineincluding the CP station parameters like current(AC/DC), vo ltage(AC/DC),circuit resistance,battery voltage/current etc.,preparing and submitting pipe to soil potential profile, graphsand ot her datapertaining to the cathodic protection of the pipeline,job complete in all respects as per specification and instructions o f Site Engineer / Engineer-in-Charge, including cost of all labour, instruments and services rendered.
861CP Readings
862\"Final Commisioning of CP system Final Commissioning of the impressed current cathodic protection system for the mainline for achieving full protection as per protec tion criteria as mentioned in the specifictions through repeated adjustments of the CP units after installation of galvanic anodes f or hot spot protection and mitigation of AC/ DC interference, if any and submission of the resultant data to the owner and testing, measuring, recording and submitting all these data once again after the lapse of a period as per specifications / directions of the Site engineer / Engineer-in-Charge, including the cost of all labour tools and materials as required, complete in all respect.\"
863Commissioning of Mainline CP system
864Pipe to Soil potential Readings : Measurement, recording and submission of Pipe to Soil Potential readings by connecting / disconnec ting the Mg anodes (for achieving optimal protection through TLPs) along the entire pipeline and at stations, including preparing an d submiting relative PSP profile and other relevant data pertaining to the cathodic protection of the pipeline, including cost of al l labour, instruments and services rendered. The readings shall be furnished as per the specifications and as per the directions of the Site Engineer/Engineer-in-Charge
865Cable Laying: Layingofall typeof cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cableracks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and insta llation of all required materialssuch as fixingclamps, screws, cable straps, tags, etc.as required (other than the supplyof the conduits, cables, pipes, cable racks, trays,poles,structures and panels) complete in all respect, including cost of alllab our, tools, consumable materials, etc. and cutting the cables in required lengths asper drawings, specification and directionsof Site Engineer / Engineer-in-Charge:
866Power cables LT : OD upto 20 mm
86760 ML CP Composite
868Zinc Anode for Hot spot protection : Supply, Installation , testing and commisioning of Zinc anode (minimum 10 Kg each) including it s tail cable of size of 1c x 25 sq.mm. XLPE/ PVC insulated stranded copper cable of total length 10 meter including PVC cap, specialback-fill material ( filled in cotton sack) with sealing compound complete in all respect including its excavations, back filling e tc. as per specifications and drawings. The work complete in all respect shall include supply of all labour , tools etc. and shall b e carried out as per the directions of the Site Engineer / Engineer-in-Charge and as per AFC drawings.
869Zinc Anode
870\"Supply& installation of Anode bed ( deep well type with MMO anodes) as per the approved configuration for Impressed Current Catho dic Protection systemincluding supply, laying & termination of all anodes, anode tail cable (XLPE insulated copper conductor) suit able with length for connecting upto Anode junction box without any joints in betweenincluding laying of PVC sleeve / trunk pipe, casing pipe , centralizers, vent pipe& drawing all the lead wires through the pipe and connecting the same with Anode bus in Anodejunction box including erection and providingfoundation of Anode Junction Box as per specifications inlcudingsupply, excavation , backfill of earth etc.as per specification & also compacting the same with soil for restoring it to normal finished ground levelall complete with all labour & material asper instruction of Site Engineer / Engineer-in-Charge, Specifications and approved draw ings. Note : Each Anode bed means anode bed at each location irrespective of number of anode strings required.\"
871Anode bed deep well type
872\"Cable Marker Supply, erectionandinstallation of MS cable markers; including excavation,installation of the markers,cement concrete grouting, back-filling etc.requiredasper drawings,specificationsand directions oftheSite Engineer,including the cost of all ma terials, labour,tools etc. complete in allrespects as per the directions of Site Engineer / Engineer-in-Charge.\"
873Cable marker
874Test Lead Point: Supply, installation, testing & commissioning of Test Lead Point (TLP) fabricated MS Sheet with hinged front door , Heavy Guage MS pipe 100 mm nominal diameter, Phenolic laminated terminal plate, brass terminal bolts, neoprene gasket for front do or, vandal proof concealed lock, etc as per latest revision of Standard AFC drawing (9200-99900-404-603-00 : STD-483). The workinc ludes providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site,including MS hard pipe for cable entry through f oundation, erection of the TLP over concrete foundation, termination of cables to the brass terminal bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazingtechnique), repairing the damage to coat & wrap (with coating repair etc.), backfilling the trenches, cleaning the site, applyingepoxy paint / powder coating etc. The work also includes supply, installation, l aying & termination of all XLPE, Cu cables of required length (as per site conditions) and size, lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like KM location, identification, TLP No., direction of flow, connec tion scheme, type etc., on the side of the TLP box, etc. The name plate shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requir ement. The work complete in all respects including all materials, tools, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge.
875TLP type \"A\" , flame proof & weather proof as per specifications and drawing (With inbuilt provision of Voltmeter & pushbutton for P SP Measurment)
876Type B (Flameproof & Weatherproof as per specifications & drawing) (With inbuilt provision of Voltmeter & pushbutton for PSP Measurm ent)
877Flameproof Type E (With Ingress Protection IP:55)as per specification
878Flameproof Type DMV (With Ingress Protection IP:55)as per specification
879Supply and Installation of CScorrosion coupon with 1 sq. cm bare metal with 2 numbers 4 sq. mm lead of minimum 10 m long lead in asdistance of 0.5 m from the pipeline inclusive of cable & terminating the cable in the TLP terminal. The corrosion couponf areto be installed with specified test lead points for which prior apporval to be obtained from owner. The item also incluseds supply, ins tallation, laying & termination of all CU cables of required length (as per site condition) and size as mentioned in the standard dr awing, toggle switch, cable glands and lugs etc. , complete in all respect as per the direction and specification detailed in the do cumetn complete with all tools , takles & other necessary requirement for preparation of the coupon . The work complete in all respe ct shall include supply of all the labours, tols etc. compete as per the direction of site engineer/engineer in charge.
880Supply, installation, testing and commissioning of two separate 4-20 mA converters(0-20 mV Input, 0 to-2VDCinput respectively,2x 4-20 mA Output in each converter) in pre installedTLPs at SV/IPIG/CP locations as per the approved drawings and specification deta iled in the document complete with tools, tackles & other necessary requirement. The work complete in all respects including all mat erials, tools, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge.
881Preparation & installation of corrosion coupon from owner supplied coated pipe. which involves preparation of sample of size 2\"x4\", application of pipeline coating material on the coupon, soldering 6 sq. mm. cable with coupon, sealing the soldered joint with epoxy , positioning the coupon at the pipe line depth and with in a distance of 0.5 M from the pipeline inclusive of cable & terminating t he cable in the TLP terminal. The corrosion coupons are to be installed with specified Test lead points for which prior approval to be obtained from Owner. The item also includes supply, installation / laying & termination of all XLPE, Cu cables of required length(as per site conditions) and size as mentioned in the standard drawings, toggle switch, cable glands and lugs etc., complete in allrespect. All as per the direction and specification detailed in the document complete with tools, tackles & other necessary require ment for preparation of the coupon. The work complete in all respect shall include supply of all labour, tools etc complete as per t he directions of the Site Engineer.
882Tele & Inst works ML HRPL
8831 ML Supply
884Supply of 2 Pair unarmoured Telephone Cable as per specifications
885Supply of 20 Pair Armoured PIJF Underground Telephone Cable as per specifications
886Supply of 5 Pair Armoured PIJF Underground Telephone Cable as per specifications
887Cat 6 UTP (LAN) Networking Cable as per tender specifications
888Wall mounted telephone socket outlet with 2 port telephone jack face plate (white/ cream colour) including RJ11 I/O. The item includ es modular plate & switch box/ gang box for fixing the face plate.
889Duplex (2 port) Face plate (Network I/O point) (white/ cream colour) for Local Area Network including RJ45 I/O, modular plate & swit ch box/ gang box for fixing the face plate.
890Wall mounted Cabinet (switching closet) for housingNetworking Equipment/ CCTV hardware, patch panel & accessories including power distribution boxes, MCBs/ Isolator Switches, required installation materials as per tender specifications
89124 port Industrial Grade Network Switch with Optical Interfacesas per tender specifications
892Power cable3 core x 2.5 mm2 Armoured, Copper as per tender specifications
893600 VA UPS with battery back-up for LAN switch
8942 ML Services
895Installation of Wall mounted Cabinet (switching closet including network switch , UPS etc in wall mount cabinet) for housingNetworking Equipment/ CCTV hardware, patch panel & accessories including power distribution boxes, MCBs/ Isolator Switches, required installation materials as per tender specifications
896Electrical-Non ITC
89780 CSW Works Composite - NIL ITC
898GI CABLE TRAY: :Supplying and spreading of approved quality fine dry river sand in cable trenches including the cost of all mate rial, transport, load and lift charges, labour, tools and tackles, consumables etc , asper drawings, specification and directionsofSite Engineer / Engineer-in-Charge
899BRICK SOLING: :Supply and laying of approved quality 75 mm thick second class brick flat soling with sand filling in the interst ices, in cable trenches for protectionincluding the cost of all brick and sand, labour, load and lift charges , tools and tackles et c , asper drawings, specification and directionsofSite Engineer / Engineer-in-Charge.
900CP-Non ITC
90170 ML CP Composite -NIL ITC
902Magnesium Anode: Supply, Installation , testing and commisioning of Magnesium anode (minimum 5 Kg each) including its tail cable o f size of 1c x 10 sq.mm. XLPE/ PVC insulated stranded copper cable of total length 10 meter including PVC cap, special back-fill mat erial ( filled in cotton sack) with sealing compound complete in all respect including its excavations, back filling etc. as per spe cifications and drawings. The work complete in all respect shall include supply of all labour , tools etc. and shall be carried out as per the directions of the EIC/ Site Engineer and as per AFC drawings.
903Magnesium Anode
904Test Lead Point: Supply, installation, testing & commissioning of Test Lead Point (TLP) fabricated MS Sheet with hinged front door , Heavy Guage MS pipe 100 mm nominal diameter, Phenolic laminated terminal plate, brass terminal bolts, neoprene gasket for front do or, vandal proof concealed lock, etc as per latest revision of Standard AFC drawing (9200-99900-404-603-00 : STD-483). The workinc ludes providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site,including MS hard pipe for cable entry through f oundation, erection of the TLP over concrete foundation, termination of cables to the brass terminal bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazingtechnique), repairing the damage to coat & wrap (with coating repair etc.), backfilling the trenches, cleaning the site, applyingepoxy paint / powder coating etc. The work also includes supply, installation, l aying & termination of all XLPE, Cu cables of required length (as per site conditions) and size, lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like KM location, identification, TLP No., direction of flow, connec tion scheme, type etc., on the side of the TLP box, etc. The name plate shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requir ement. The work complete in all respects including all materials, tools, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge.
905Type A (With Ingress Protection IP:55)
906Type B (With Ingress Protection IP:55)
907Type C (With Ingress Protection IP:55)
908Type D (With Ingress Protection IP:55)
909Type DAC (With Ingress Protection IP:55)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail