}

Tender For Quotation For Basic Rate Of Material For Energy Department, Jharkhand., ranchi-Jharkhand

Government Departments has published Tender For Quotation For Basic Rate Of Material For Energy Department, Jharkhand.. Submission Date for this Tender is 14-12-2023. Fire Resistant Coatings Tenders in ranchi Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

40979658
Tender For Quotation For Basic Rate Of Material For Energy Department, Jharkhand.
Open Tender
Indian
Jharkhand
Ranchi
14-12-2023

Tender Details

Tender For Quotation For Basic Rate Of Material For Energy Department, Jharkhand.- 1 Façade Light, 180 Watt I / P V-88 ~264Vac, Pf >0.95 / 230V Ac Control Protocal-Dmx 512, Colour-Rgbww, Protection Tyep Costant Current Limiting, Recovers Automatically After Fault Condition Is Removed I.E Shut Down O / P Voltage, Repower On To Recover, Safety Standard- Ul60950-1, Tuven60950-1 Eac Tp Tc 004 Approved, Total Fitting Ip 65, Class 1 Insulation, Beam Angle-20 Degree, Lense- Pmma Pcb Covered With Thermal Epoxy Silicon Type Minium 4 Mm Thick Fixture Body- Al Die Casting And Rectangular Shape. Control Circuit Induvidual, Dynamic Control Facade Lighting System. Make- Unilux Llt Model No.- Uni / Fldmx 240 / Colourpro, Cirtificate-Bis, Ik05, Ip 65, Lm80, Lm79, Phoobiologocal Test Report, Led-Osram / Edision, Driver-Menwell 2 Façade Light, 40 Watt I / P V-88~Vac, Pf .0.95 / 230V Ac, Control Protocal - Dmx 512, Colour-Rgbww, Protection Type: Constant Current Limiting, Recovers Automatically After Fault Condition Is Removed I / E Shut Down O / P Voltage, Repowre On To Recover, Safety Standard- Ul60950-1, Tuven60950-1 Eac Tp Tc 004 Approved, Total Fitting Ip 65, Class 1 Insulaton, Beam Angle- 20 Degree, Lense- Pmma Pcb Convered With Thermal Epoxy Silicon Type Minium 4 Mm Thick Fixture Body- Al Die Casting And Rectangular Shape. Control Circuit Individual, Dynamic Control Facade Lighting System. Make- Unilux Llt Model No.-Uni / Fldmx 240 / Colourpro. Cirtificate- Bis, Ik05, Ip 65 Lm80, Lm79, Phoobiologocal Test Report, Led-Osram / Edision, Driver-Menwell. 3 Façade Light, 50 Watt I / P V-88~264 Vac, . Pf .0.95 / 230V Ac, Controla Protocol- Dmx 512, Colour- Rgbww, Protection Type : Constant Current Limiting, Recovers Automatically After Fault Condition Is Removed I / E Shut Down O / P Voltage, Repower On To Recover, Safety Standard- Ul60950-1, Tuven60950-1 Eac Tp Tc 004 Approved, Total Fitting Ip 65, Class 1 Insulation, Beam Angle- 20 Degree, Lense- Pmma Pcb Covered With Thermal Epoxy Silicon Type Minium 4 Mm Thick Fixture Body- Al Die Casting And Rectangular Shape, Control Circuit Individual. Dynamic Control Facade Lighting Syste. Make- Unilux Llt Model No.- Uni / Fldmx 240 / Colourpro. Cirtificate- Bis, Ik05, Ip 65, Lm80, Lm79, Phoobiologocal Test Report, Led-Osram / Edision, Driver- Menwell. 4 Supply Controlling Of Dmx512 Signal Amplifier Set 5 512 X 2 Channel Dmx Controller Live And Stand Alone Both Operation 6 Supply Of Out Door Distribution Box With Mccb Of Sutiable Size. 7 Supply And Laying Of 3 Core 4.0 Sq Mm Flexible Copper Cabel. 8 Supply And Laying Of 3 Core 1.5 Sq Mm Flexible Coppercable 9 Rgb Type Neon Flex With Control Protocol Dmx, Aluminium Channel & Ac To Dc Power Supply, 18 Watt / Mtr. Silicon Based Ip 66 Type, Uni / Fldmx18 / Colourpro ( Linner ) 10 Providing And Installation Of Chemical Earhting Sytem Length 3 Mtr 25 Mm Dia, High Tensile Low Carbon Steel Road Bonded By High Conductivity Copper On Outer Surrace As Per Iec 62561-2 Including Universl Clamp. 11 Supply And Laying 25Mm X 5Mm G.I Strip At 0.5 Mtr Below Ground As Strip Earthign Electrode. 12 Suppply And Fixing Of Following Sizes Of Medium Pvc Conduit Along With Accessories In Surface / Recess Including Cutting Of Wall And Making Good The Same Cast Of Recessed Conduit As Reqd. 25 Mm 13 150 Watt Flood Lgiht Code: Wattage : 150 Cct: Ww Ip Rating: Ip65 Make- Jaguar / Bajaj / Or Equi. 14 90 Watt Flood Light Code: Wattage : 90 Cct : Ww Ip Rating : Ip65 Make: Jaguar / Bajaj / Or Equi. 15 18 Watt Surface Light Code: Wattage: 18 Cct : Ww Ip Rating : Ip20 Shape: Round. Make- Jaguar / Bajaj / Or Qui. 16 18 Watt Flood Lgiht Code : Wattage: 18 Cct :Ww Ip Rating : Ip65 Shape: Round. Make- Jaguar / Bajaj / Or Equi. 17 18 Watt Post Up Light Code: Wattage : 18 Cct : Ww Ip Rating : Ip54 Shape: Round. Make- Jaguar / Bajaj / Or Equi. 18 18 Watt Post Up Light Code: ( Decorative ) Wattage: 18 Cct :Ww Ip Rating : Ip65 Shape:Round Make- Jaguar / Bajaj / Or Equi. 19 7 Watt Decorative Bollard Light Code: Wattage: 7 Cct :Ww Ip Rating : Ip65 Shape:Round. Make- Jaguar / Bajaj / Or Equil 20 Decorative Pole Single Arm 5 Mtr 21 Installation Of Decorative Pole 22 Installation Of Bollard. 23 Supply, Installation, Testing And Commissioning Of 5Th Generation ( Min ) Full Inverter Vrf System With Modular Type Outdoor Unit Of Scroll Dc Compressors For Cooling And Heating Applications. Offered Odu Should Have Minimum Cop Of 3.7 At 100% Loading For Ambient Temp 35 Deg C Dbt And Indoor Conditions 27 Deg C Dbt & 19 Deg C Wbt. Offered Outdoor Units Must Have Minimum Ieer Of 5.5. Manufacturer Of The Proposed Vrf Unit Shall Be The Oem Of The Compressor Also. Outdoor Unit Should Consists Of Minimum 2Nos Inverter Compressor For & Above 18Hp Odu. The Unit Shall Be Suitable Of 3Phase, 50Hz & 380V Power. The Unit Shall Have Inbuilt Oil Level Sensor Inside Compressor So As To Have 24 X 7 Monitoring Of Safe Oil Level For Ensuring Proper Lubrication Of Compressor For Its Safe Operation. This Oil Level Sensor Technology Will Further Increase Energy Saving By Avoiding Periodic ( 8Hrs ) Oil Return Cycle. The Unit Should Have Factory Manufactured Anti Corrosive Technology For Its Condenser Fins So As To Resist Corrosive Environment Created Due To Pollution, Acidic Rains. This Anticorrosive Treatment Should Have Third Party Certification From Ul / Tuv Under The Salt Spray Test Method Of Iso21207. Make: Lg 24 20Hp ( Heating & Cooling ) 25 18Hp ( Heating & Cooling ) 26 16Hp ( Heating & Cooling ) 27 Supply, Installation, Testing And Commissioning Of Ceiling Suspended Type4-Way Cassetteunit Completewith Electronic Expansion Valve, Evaporator Coil, Factory In-Built Drain Pump, Drain Pan, Panel, Cordless Remote, Etc Of Below Capacities. Make: Lg 28 2.5Tr 29 3.0Tr 30 3.5Tr 31 4.0Tr 32 4.5Tr 33 Supply, Installation, Testing And Commissioning Of Wall Mount Type Vrf Indoor Unit With Electronic Expansion Valve, Evaporator Coil, Drain Pan, Panel, Cordless Remote, Etc Of Below Capacities. Make: Lg 34 1.59Tr 35 Supply, Installation, Testing And Commissioning Of Ceiling Suspended Type Ceiling Suspendedtype High Static Ducted Unit Complete With Electronic Expansion Valve, Evaporator Coil, Factory In-Built Drain Pump, Drain Pan, Panel, Cordless Remote, Etc Of Below Capacities. Make: Lg 36 8Tr 37 Supply Of Ceiling Suspended Type Ceiling Suspendedtype Fresh Air Intake Unit Complete With Electronic Expansion Valve, Evaporator Coil, Drain Pan, Panel, Cordless Remote, Etc Of Below Capacities. Make: Lg 38 8Tr 39 Supply, Installation, Testing And Commissioning Of Vrf Y-Joint As Below 40 Idu Joint 41 Odu Joint 42 Supply, Installation, Testing And Commissioning Of Touch Screen Type Central Controller Can Control Upto 64Nos Indoor Unit, Having Feature As Below: A. Can Control Indoor Function: On / Off, Mode, Temperature, Fan Speed B. Indoor Operation Scheduling Can Be Done C. Can Be Intigrate With Bacnet Ip / Modbus Tcp 43 Supply, Installation, Testing And Commissioning Of Interconnecting High Pressure Copper Refrigerant Piping Work Suitable For Refrigerant R 410Adulyinsulatedwithelastomericnitrile Rubber Typetubular Insulation Of Density 55+ / -10% Kg / M3 Betweenindoor&Outdoor Units As Per Specifications. External Refrigerant Piping Shall Be Laid On 16 G Gi Covered Perforated Cable Trays. Piping Inside Occupied Area & Vertical Shaft Inside The Ahu Room Shall Be Supported Using 16 G Gi Hangers. All Exposed Pipe Shall Have Uv Coating On Insulation & Cost To Be Included In The Piping. Cable Tray Is Quantified Seperately. 44 41.3 Mm O.D. ( Min. Wall Thickness - 1.43 Mm, Insulation - 19 Mm Thick ) 45 34.9 Mm O.D. ( Min. Wall Thickness - 1.21 Mm, Insulation - 19 Mm Thick ) 46 28.6 Mm O.D. ( Min. Wall Thickness - 0.99 Mm, Insulation - 19 Mm Thick ) 47 22.2 Mm O.D. ( Min. Wall Thickness - 0.80 Mm, Insulation - 19 Mm Thick ) 48 19.1 Mm O.D. ( Min. Wall Thickness - 0.80 Mm, Insulation - 13 Mm Thick ) 49 15.9 Mm O.D. ( Min. Wall Thickness - 0.80 Mm, Insulation - 13 Mm Thick ) 50 12.7 Mm O.D. ( Min. Wall Thickness - 0.80 Mm, Insulation - 13 Mm Thick ) 51 9.5 Mm O.D. ( Min. Wall Thickness - 0.80 Mm, Insulation - 13 Mm Thick ) 52 6.4 Mm O.D. ( Min. Wall Thickness - 0.80 Mm, Insulation - 13 Mm Thick ) 53 Supply, Installation, Testing And Commissioning Of Upvc Condensatedrainwaterpipingof Density 20 Kg / M³ Complete With Fittings Like Elbows, Tees, Reducers, Bends, Flanges, Supports, Insulation Etc. As Required And Of Following Sizes. 54 25 Mm Dia Pipe, Insulation Thickness - 13 Mm 55 40 Mm Dia Pipe, Insulation Thickness - 13 Mm 56 Supply, Laying, Termination Of 2Cx1.5 Sqmm Scheilded Control Cable For Communication Between Vrf Odu & Idu 57 Design, Supply, Fabrication & Erection Of Air Distribution Gss Ducting In Accordance With The Approved Ducting Lay Out Drawing, Complete With All Accessories, Dampers, Guide Vanes, Support, Etc. 58 22G ( 0.8Mm ) 59 24G ( 0.63 Mm ) 60 Supply, Installation, Testing & Commissioning Of Thermal-Insulated Flexible Duct Of Following Sizes Duly Supported At Regular Interval As Per Site Requirement Hangers, Nut & Bolts, Gaskets, Round Clamping, Vanes, Etc Complete As Per Specifications In Accordance With The Approved Shop Drawings. 61 Dia 100Mm 62 Supply, Installation And Testing Of Rigid Pvc Pipe With 6 Kg / Cm2 Rating With All Necessary Fittings Such As Elbows & Cowl With Bird Screens For Fresh Air And Exhaust Air. ( If Required ) 63 Dia 150Mm 64 Acoustic Insulation Inside The Sa Ducts With 12 Mm Thick F.G., Tissue Paper & 32 G Aluminum Perforated Sheet. 65 12 Mm 66 Supplying And Fixing Of 13Mm Thickness Duly Laminated Aluminum Foil Of Mat Finish Closed Cell Nitrile Rubber ( Class O ) Insulation On Duct After Applying Suitable Adhesive For Nitrile Rubber. The Joints Shall Be Sealed With 50 Mm Wide And 3 Mm Thick Self Adhesive Nitrile Rubber Tape Insulation Complete As Per Specifications And As Required 67 Installation Of Grill / Vcd : 68 Supply, Installation, Testing , Balancingand Fixingofpowder Coated Aluminiumextruded Grillfor Returnairasper Specification & Thesizes Will Be As Per Schedules Anddrawing.Refer Technical Specification For Detail Description.The Colour Approval Shall Be Taken From Client / Architect Before Ordering Of Material. 69 Supply, Installation, Testing, Balancingand Fixingofpowder Coated Aluminium Extruded Grillwith Aluminium Construction Collar Damper For Supplyairasper Specification & Thesizes Will Be As Per Schedules Anddrawing.Refer Technical Specification For Detail Description.The Colour Approval Shall Be Taken From Client / Architect Before Ordering Of Material. 70 Installation Of Mouth Piece Canvass Connection : 71 Connecting Duct With Indoor Unit With Suitable Canvas Cloth 72 Supply And Commissioning Of Vrf Systems Including Additional Referigernt R410ain All Respect To Complete The Systemas Per Site Requirements 73 Duly Epoxy Coated / Galvanised Of M.S. Structure For Installing Vrv / Dx Outdoor Units Along With Vibration Isolation Pad . For Vrv / Vrf Module / Outdoor 74 Providing And Fixing Tiled False Ceiling Of Specified Materials Of Size 595X595 Mm In True Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanized @ 120 Grams / Sqm, Both Side Inclusive ) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick ( Minimum ) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet, 1200 Mm Long Spaced Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel To Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting / Making, Opening For Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Of Size 27 X 37 X 25 X1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gi Adjustable Rods With Galvanised Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. 12.5 Mm Thick Square Edge Pvc Laminated Gypsum Tile Of Size 595X595 Mm, Made Of Gypsum Plasterboard, Manufactured From Natural Gypsum As Per Is 2095 Part I And Laminated With White 0.16Mm Thick Fire Retardant Pvc Film On The Face Side And 12Micron Metalized Polyester On The Back Side With All Edges Sealed With Sub Head : 12.0 Roofing 266 Code Description Unit Rate No.The Face Side Pvc Film Which Goes Around And Wrapsthe Edges And Is Bonded To The Edges And The Back Side Metalized Polyester Film So As To Make The Tile Acompletely Sealed Unit. 75 Rental Of Material Including L / C For S / F Of The Followoing Item And Dismentaling Charges For The Same. 76 1 ) Tower Air Conditioenrs With Extended Flexible Refrigrant Pipe For Outdoor Rate Per Tr.1St Day 77 Sub Day 78 1200 Mm ( 48 ) Special Finish Ceiling Fan Complete Including Connection Etc As Rqd. 79 Repairing Of 30Kva Online Ups By Replacing Following Items As Reqd. 80 Bypass Card ( Ps1312 Dr1 ) Hsn:85049090 81 Inverter Card ( Ps1503dr4 ) Hsn:85049090 82 Dc Fan ( Nmb-24V / 0.49Amp ) - Hsn:85049090 83 Service Charge ( Sac:998717 ) 84 S.I.T.C Of 4500Va / 36V Sine Wave Inverter 85 Painting Of 7 Mtr Pole 86 Painting Of 9 Mtr Pole

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail