}

Tender For Renovation Of The Office Space Being Provided To Consultants Of Cpmu,Drip Phase Ii Iii, puram-Delhi

Central Water Commission has published Tender For Renovation Of The Office Space Being Provided To Consultants Of Cpmu,Drip Phase Ii Iii. Submission Date for this Tender is 16-12-2023. Dismantling Work Tenders in puram Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

40956210
Tender For Renovation Of The Office Space Being Provided To Consultants Of Cpmu,Drip Phase Ii Iii
Open Tender
Indian
Delhi
Puram
16-12-2023

Tender Details

Tender For Renovation Of The Office Space Being Provided To Consultants Of Cpmu, Drip Phase Ii Iii; 1 Renovation Ofthe Office Space Being Provided To Consultants Of Cpmu, Drip Phase-Ii & Iii 2 Dismantling Aluminium / Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Material And Stacking Of Serviceable Material With In 50 Meters Lead As Directed By Engineer-In-Charge. 3 Dismantling Of Gi Shaft Of Centalised Ac Duct Including Disposal Of Rubbish To The Dumping Groundwithin 50 Metres Lead. 4 Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm 5 Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres Lead. 6 Dismantling Wooden Boardings In Lining Of Walls And Partitions, Excluding Supporting Members But Including Stacking Within 50 Metres Lead :Thickness Above 10 Mm Up To 25 Mm 7 Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantledor Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or Asapproved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leadsincluding All Lifts Involved. 8 20 Mm Cement Plaster Of Mix : 1:4 ( 1 Cement: 4 Fine Sand ) . 9 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3 Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600X600 Mm 10 Providing And Fixing Tiled False Ceiling Of Specified Materials Of Size595x595 Mm In True Horizontal Level, Suspended On Inter Lockingmetal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanized @120 Grams / Sqm, Both Side Inclusive ) Consisting Of Main T Runnerwith Suitably Spaced Joints To Get Required Length And Of Size 24X38mm Made From 0.30 Mm Thick ( Minimum ) Sheet, Spaced At 1200Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30Mm Thick ( Minimum ) Sheet, 1200 Mm Long Spaced Between MainT At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm Andsecondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of0.30 Mm Thick ( Minimum ) Sheet To Be Interlocked At Middle Of The1200x600 Mm Panel To Form Grids Of 600X600 Mm And Wall Angle Ofsize 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texturein The Grid Including, Required Cutting / Making, Opening For Serviceslike Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. MainT Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Ofsize 27 X 37 X 25 X1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50Mm Long Dash Fasteners, 4 Mm Gi Adjustable Rods With Galvanisedbutterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mmcenter To Center Along Main T, Bottom Exposed Width Of 24 Mm Of Allt-Sections Shall Be Pre-Painted With Polyester Paint, All Complete Forall Heights As Per Specifications, Drawings And As Directed Byengineer-In-Charge.12.5 Mm Thick Fully Perforated Gypsum Board Tile Madefrom Plasterboard Having Glass Fibre Conforming To Is:2095 Part I, Of Size 595X595 Mm, Having Perforation Of9.7X9.7 Mm At 19.4 Mm C / C With Center Borders Of 48Mm And The Side Borders Of 30 Mm, Backed With Nonwoven Tissue On The Back Side, Having An Nrc ( Noisereduction Coefficient ) Of 0.79, With 50 Mm Resin Bonded Glass Wool Backing. 11 Providing And Fixing At All Height Wall Panelling With Phenol Bondedbamboo Mat Board Conforming To Is:13958-1994 Including Providingand Fixing To Frame Work Made Of 50Mm X 50Mm Hardwood Plugsincluding Cutting Brick Work And Fixing In Cement Mortar And Makinggood The Wall Etc. And Also Providing And Fixing Wooden Mouldedcorner Beading Of Triangular Shape To The Junction Of Panelling Etc.With Iron Screws All Complete As Per Direction Of Engineer-In-Charge.12Mm Thickness 12 Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paintand The Like By Scrapping, Sand Papering And Preparing The Surfacesmooth Including Necessary Repairs To Scratches Etc. Complete. 13 Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Overplastered Surface To Prepare The Surface Even And Smooth Complete. 14 Distempering With 1St Quality Acrylic Distember ( Ready Mix ) Havingvoc Content Less Than 50 Grams / Litre Of Approved Brand Andmanufacture To Give An Even Shade : Old Work ( One Or More Coats ) 15 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps Atjunctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Includingcleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P.Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) : 16 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately ) 17 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) : With Float Glass Panes Of 5 Mm Thickness ( Weight Notless Than 12.50 Kg / Sqm ) 18 Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is : 6315, Having Brand Logo Embossed On The Body / Plate With Double Spring Mechanism Anddoor Weight Upto 125 Kg, For Doors, Including Cost Of Cutting Floors, Embedding In Floors As Required And Making Good The Same Matching To The Existing Floor Finishing And Cover Plates With Brass Pivot Andsingle Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Engineer-In-Charge. With Stainless Steel Cover Plate Minimum 1.25 Mm Thickness 19 Fitting Charges Of Door & Windowshutters, Float Glass Etc. 20 Providing And Fixing Film On Glass Of Approved Make& Shade With Complete Asper Architectural Drawingsand Direction Of Engineer In Charge 21 Deduction Of The Cost Of Exsting Duct Of Centrailed Ac 22 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bellpoint With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductorsingle Core Cable In Surface / Recessed Steel Conduit, With Pianotype Switch, Phenolic Laminated Sheet, Suitable Size Ms Box Andearthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copperconductor Single Core Cable Etc. As Required.Group C 23 Wiring For Light / Power Plug With 2X4 Sq. Mm Frls Pvcinsulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvcinsulated Copper Conductor Single Core Cable For Loop Earthingas Required. 24 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With Thefollowing Sizes Of Frls Pvc Insulated Copper Conductor, Singlecore Cable In Surface / Recessed Steel Conduit As Required.2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire 25 Supplying And Fixing Following Modular Switch / Socket On Theexisting Modular Plate & Switch Box Including Connections Butexcluding Modular Plate Etc. As Required.5 / 6 A Switch 26 Supplying And Fixing Following Modular Switch / Socket On Theexisting Modular Plate & Switch Box Including Connections Butexcluding Modular Plate Etc. As Required.15 / 16 A Switch 27 Supplying And Fixing Following Modular Switch / Socket On Theexisting Modular Plate & Switch Box Including Connections Butexcluding Modular Plate Etc. As Required.3 Pin 5 / 6 A Socket Outlet 28 Supplying And Fixing Following Modular Switch / Socket On Theexisting Modular Plate & Switch Box Including Connections Butexcluding Modular Plate Etc. As Required.6 Pin 15 / 16 A Socket Outlet 29 Supplying And Fixing Following Size / Modules, Gi Box Alongwithmodular Base & Cover Plate For Modular Switches In Recess Etc.As Required.3 Module ( 100Mmx75mm ) 30 Supplying And Fixing Following Size / Modules, Gi Box Alongwithmodular Base & Cover Plate For Modular Switches In Recess Etc.As Required.6 Module ( 200Mmx75mm ) 31 Supplying And Fixing Following Size / Modules, Gi Box Alongwithmodular Base & Cover Plate For Modular Switches In Recess Etc.As Required.12 Module ( 200Mmx150mm ) 32 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earthbar, Din Bar, Interconnections, Powder Painted Includingearthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) .16 Way, Double Door 33 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, CCurve, Miniature Circuit Breaker Suitable For Inductive Load Offollowing Poles In The Existing Mcb Db Complete Withconnections, Testing And Commissioning Etc. As Required.Single Pole 34 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, CCurve, Miniature Circuit Breaker Suitable For Inductive Load Offollowing Poles In The Existing Mcb Db Complete Withconnections, Testing And Commissioning Etc. As Required.Single Pole And Neutral 35 Supplying And Fixing Following Rating, Double Pole, 240 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63 A 36 Supply And Installation Of Led Lights 2X2 Complete In All Respect. 37 Supply And Installation Of Wall Fan Complete In All Respect. 38 Supply And Installation Of Copper Pipe For 8 No. 3 Tonn Cassettee Ac @ 15 M / Ac 39 Supply And Refilling Of 8 No.3 Tonn Cassette Ac Gas. 40 Installation Charges Of 8 No.3 Tonn Cassettee Ac Including Fasteners Etc. 41 Supply And Installation Of 08 No. Stand For Cassette Ac 42 Supply And Installation Of 04 No. Core Wire From Indoor To Outdoor Of 08 No.Cassette Ac 43 Supply And Installation Of 08 No. Window Ac 44 Providing And Fixing Of Roller Blinds

Key Value

Document Fees
Refer document
EMD
INR 100000.0 /-
Tender Value
INR 49.83 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail