Surveying, Soil Investigation, Design And Supply Of All Materials, Labour, T&P Etc Required For Construction Of Overhead Tank, Pump House, Boundary Wall, Approach Roach, Gates, Site Development, Supply Of All Materials For Laying And Jointing Of Rising Main, Distribution System And E&M Work For Chailnagar Panchyat Water Supply Scheme Distt. Kaushambi.; 1 Construction Of R.C.C Overhead Tank 2 Submission Of Vetted Design, Drawing And Supply Of All Materials, Labour, T&P Etc. And Construct An Rcc Over Head Tank Of M-30 Concrete With Following Capacity With Minimum Freeboard Of 15Cm, Rcc Staircase And 1.2M Wide Balcony, G.I. Pipe And Angle Iron Posts Around The Balcony And At The Dome Periphery, Two Column Rcc Staircasewith Ss Railing In A Slope Of 3:1 From The Balcony To The Top Of Tank And Inside The Tank, Supply And Fixing 10Mm Gauge M.H. Cover Of 60Cm X 60Cm Size With Locking Device, Ventilator, Lightening Conductor, Digitalwater Level Indicator, Fixing Of Puddle Collars And Bell Mouths, Supply And Fixing M.S. Clamps With Rcc Coloumn, 25 Mm Thick Pcc 1:2:4 Floor Over 80 Mm Pcc 1:4:8 In Appron, 150 Mm Semicircular Drain Around The Tank, Escape Channel Of 20M Length, Box Type Enclosure At The Entrance Of The Staircase Having Locking Arrangements, Water Proofing, Three Coats Of Approved Quality Apex Paint And Testing Of Tank For Water Tightness Etc. And Including Testing Bearing Capacity Of Soil , Site Clearance And Other Unforeseen Items As Per Specifications In Tender Document And Manuals Etc. The Depth Of Foundation Is Minimum 2.50M From Existing Ground Level On Pile / Raft Foundation Or At More Depth Based On Design Of Tank For Which No Extra Claim Shall Be Entertained. Made Up Level Of Oht Shall Be Taken As 0.60M Above Road Level. Extra Earth Required For Made Up Level Shall Be Arranged By The Contractor At His Own Cost.All Works Complete Upto The Satisfaction Of Engineer-In-Charge. 3 Supply And Fixing Of C.I D / F Pipes With Required Specials Such As Reducers, Duck Foot Bend, Bell Mouth Etc In Inlet Of The Tank Including Supply Of Ms Clamps, Rubber Insertion Sheet, Nut Bolts, Washer Etc Complete As Detaileda. C.I D / F Pipe Inlet - 2Nos Of 200Mm Diab. C.I D / F Pipe Outlet - 2Nos Of 350Mm Diac. C.I D / F Pipe Overflow - 1Nos Of 250Mm Diad. C.I D / F Pipe Washout - 1Nos Of 250Mm Dia 4 Supply And Fixing Of C.I D / F Sluice Valves As Per Is Code Including Supply Of Jointing Materials , Rubber Insertion Sheet, Nut Bolts, Washer Etc Complete As Detaileda. C.I D / F Pipe Inlet - 2Nos Of 200Mm Diab. C.I D / F Pipe Outlet - 2Nos Of 350Mm Diac. C.I D / F Pipe Overflow - 1Nos Of 250Mm Diad. C.I D / F Pipe Washout - 1Nos Of 250Mm Dia 5 Supply Of Valves, Materials, Labour, T&P And Construct Brick Masonary Sluice Valve Chamber, Fire Hydrant Chamber Including Rcc Cover As Per Type Dept. Design At Inlet, Outlet And Washout Pipes. The Rcc Cover Shall Be Casted In Ss Channel Section With Handles On Both Sides. ( Chambers For Washout And Overflow May Be Combined ) 6 The Words U.P.Jal Nigam ( Urban ) Stating Year Of Construction, Capacity Of Oht As Per Directions Of Engineer-In-Charge Shall Be Painted Prominently In Letter Not Less Than 30 Cm In Height. Maintenance For 12 Months Including Supply Of All Materials Etc Complete. 7 550 Kl @ 20M Staging 8 Renovation Of Existingover Head Tank 9 Renovation Of Existingover Head Tank Which Includes Following Items:- Providing And Erection Of Scaffolding And Shuttering Material Like Challi, Gurra, Nail, Bans, Ballia, Patra Etc. Required For Complete Of Work On All Surgace Area Of Oht From Top Dome To G.L. So As To Give Strong And Safe Plateform To Workers To Work On All Part Of Oht For Repair And Strengthning As Per Direction Of Engineer InCjharge. Surface Preparation- The Surface Of Structure To Be Treated For Strengthning Shall Be Reoughened Properly Either By Raking Joints Or By Haching The Cement Concrete Surface With A Specially Made Haching Tool Or Otherwise Alternatively To / Make The Surface Rough And Dust Free By Providing Spatter Key Or Wire Brush. Injection Grouting In Vertical Surface / Wall Placing And Fixing Nozzle By Drilling Machine In Tank Wall Having Minimum Dia Of Nozzle 15Mm And Provide On A Regular Interval Not Exceeding 1M Including Construction Joints. Injection Of Pidicrete Am ( Ploymer Based On Shrinkage High Strength Grout ) Admisxed With Cement Through Nozle Under Pressure By Sump @ 250Gms Per Bag Of Cement Sealing The Nozzle After Frounting With Polymer Product Mixed With Cement, Making Tank Body In Working And Seapage Free Condition. Change Of Steel Ladder Inside The Tank, Repair Of Mh Cover Of Top Dome, Change Of Mosqeuto Jali With New One Complete. Supply And Fixing Of 20Mm Dia G.I.Pipe Railing In Stair Case And Balcony. ( Taking Only 25% New And 75% Old Materials ) Laying And Fixing Of 3Mm Thick Ms Wire Mesh On Roof Of Slab For Nominal Reinforcement Including Cost Of All Labour, Materials, T&P Etc Required For Completion Of Work. 25 Mm Thick 1:2:4 Plain Cement Concrete Flooring In Apron With Cement Coarse Sand And 20Mm Gauge Stone Ballast, Laid In Panels Finished With 3Mm Floating Coat Of Neat Cement Of Cement Including 75Mm Thick Base Concrete Of 1:4:8 Including Supply Of All Material. Painting Of Outer Surface Of Oht With Weather Proof Paint ( Like Apex Etc. ) As Per Direction Of Engineer In-Charge. Painting Of Iron Work With 1 Coat Primer & 2 Coats Of Approved Emultion Paint As Per Direction Of Engineer Incharge 10 Supply And Installation Of Ci D / F Inlet Pipe, Outlet Pipe, Washout Pipe, Overflow Pipes And Connecting Sluice Valves, Fire Hydrant Valves Of Required Dia And Construction Of Masonary Chambers. All Necessary Work Required For Proper Functioning Of Tank Upto The Satisfaction Of Engineer-In-Charge 11 450 Kl 12 150 Kl 13 Construction Of Pump Houses 14 Provide All Materials, Labour, T&P Etc. Complete And Construct Pump House Size ( 3.6X3.0 ) M Chlorinating Room Size ( 1.8 X 2.5X 3.0 ) M As Per Departmental Type Design And Specifivations Given In Tender Document Including Supply Of Labour, Material Etc For Completion Of Works Upto The Satisfaction Of Engineer-In-Charge 15 Distribution Network 16 Supply Of The Following D.I. Pipes ( K-7 ) Including Specials Conforming To I.S -8329 / 2000 Or Its Latest Amendment ( S ) . Including F.O.R. Destinations Rate Per Metre In Rs., Anywhere In U.P. Including Cost Of One Rubber Gasket Per Pipe Length & Inclusive Of All Taxes & Duties, Third Party Inspection Charges, Packing & Forwarding Charges, Transit Insurance Charges, Road Transportation Charges Etc. 17 350 Mm Dia 18 300 Mm Dia 19 250Mm Dia 20 200 Mm Dia 21 Supply Of The Following Hdpe Pipes Pn-6 / Pe-100 Including Electrofusion Specials As Per I.S. Code No. 4984 / 14151 / 12786 / 13488 Or Its Latest Amendment In Coils / Slandered Lengths With Necessary Jointing Material Like Elctrofusion Coupler For Joints / Junctions, Flanged Joint, Inclusive Of Third Party Inspection Charges Packing And Forwarding Charges, Transit Insurance Charges, Road Transportation Charges Etc. F.O.R. Destination Etc. Complete 22 200 Mm Dia Hdpe Pipe Pn-6: Class Pe-100 23 180 Mm Dia Hdpe Pipe Pn-6: Class Pe-100 24 160 Mm Dia Hdpe Pipe Pn-6: Class Pe-100 25 140 Mm Dia Hdpe Pipe Pn-6: Class Pe-100 26 110 Mm Dia Hdpe Pipe Pn-6: Class Pe-100 27 90 Mm Dia Hdpe Pipe Pn-6: Class Pe-100 28 Excavation For Pipeline Trenches In Ordinary Soil ( Loam, Clay Or Sand ) Including Lift Upto 1.5M And Lead Upto 50M And Refilling, Watering, Ramming Of Excavted Earth In To The Trenches And Disposal Of Surplus Earth Upto 50M From The Center Of The Trenches. D.I. ( K-7 ) Pipes. Guidelines On Environmental Construction And Demolition ( C&D ) Wastes And Grap Circulated By Central Pollution Control Board 2017 And Its Latest Ammendments Shall Be Adhered To For Excavation Of Trench During Laying Of Pipeline. Surplus Material After Backfilling Shall Be Immediately Removed From Site And Temporary Restoration Shall Be Done To Make Road Motorable 29 Carting From The Following Sizes Of D.I.Pipes ( Class K-7 ) And Specials To The Site Of Work, Lowering Them In To Trenches And Laying True To Alignment And Gradient, Cutting Of Pipes, Making Joints Including Cost Of Jointing Material, Rubber Rings, Labour, T&P Etc Including Hydraulic Testing Of Pipeline. It Includes Making Alignment On City Roads, Making Of Trial Pits To Investigate Location Of Various Undergroung Services Like Telephone Cables, Electric Cables, Existing Water And Sewer Lines Complete Required For Proper Completion Of Work. Only Sbr Rubber Gaskets To Be Used As Per Is 5382 And Is 12820 Including Making Bypass Arrangement. 30 350 Mm Dia. D.I. ( K-7 Pipes ) 31 300 Mm Dia. D.I. ( K-7 Pipes ) 32 250 Mm Dia. D.I. ( K-7 Pipes ) 33 200 Mm Dia. D.I. ( K-7 Pipes ) 34 Carting From The Following Sizes Of Hdpe Pn-6 / Pe-100 And Specials To The Site Of Work, Lowering Them In To Trenches And Laying True To Alignment And Gradient, Cutting Of Pipes, Making Joints Including Cost Of Jointing Material, Rubber Rings, Labour, T&P Etc Including Hydraulic Testing Of Pipeline. It Includes Making Alignment On City Roads, Making Of Trial Pits To Investigate Location Of Various Undergroung Services Like Telephone Cables, Electric Cables, Existing Water And Sewer Lines Complete Required For Proper Completion Of Work. Only Sbr Rubber Gaskets To Be Used As Per Is 5382 And Is 12820 Including Making Bypass Arrangement.Jointing Between Hdpe Pipes Shall Be Done As Per Latest Is: 7634 Part-Ii. Only Bar Coded Electro-Fusion Machine ( Automatically Readable ) That Can Read The Bar Code Of The Fittings Automatically 35 200 Mm Dia Hdpe Pipe Pn-6: Class Pe-100 36 180 Mm Dia Hdpe Pipe Pn-6: Class Pe-100 37 160 Mm Dia Hdpe Pipe Pn-6: Class Pe-100 38 140 Mm Dia Hdpe Pipe Pn-6: Class Pe-100 39 110 Mm Dia Hdpe Pipe Pn-6: Class Pe-100 40 90 Mm Dia Hdpe Pipe Pn-6: Class Pe-100 41 Supply Of The Following Dia Of Valves, Class I, Working Pressure 10 Kg / Cm2 Confirmingto Is: 780 / 1969 Or Its Latest Amendments, F.O.R. Destination, Carting And Lowering Them Into The Already Preparedtrenches, Fixing In Position And Jointingthem With Pipelines And Testing Etc. Completeand Also Including Supply Of Jointing Materials Etc. Complete .Including Alltaxes And Insurance, As Per Instructions Of Engineer -In -Charge. 42 350Ø 43 250Ø 44 200Ø 45 150Ø 46 100Ø 47 80Ø 48 Scour Valve - 80 Mm Dia 49 Air Valve - 50 Mm Dia 50 Fire Hydrant - 80 Mm Dia. 51 Dismantling Of Roads For Laying Of Pipe Line Including Sorting Out And Stacking Of Serviceable Materials, Stacking And Disposal Of Unserviceable Materials Including Dismantling And Cleaning Of Septic Tanks As Deemed Necessary 52 Bituminous Road 53 Cement Concrete Road 54 Interlocking Road / Paver 55 Reinstatement Of Following Type Of Roads Dismantled During Laying Of Pipe Line Including Leakage Repair If Any And Supply Of All Materials, Labour And T & P Etc. Required For Proper Completion Of The Work. 56 Bituminous Road 57 Cement Concrete Road 58 Interlocking Road ( 40 % New & 60% Quantity Old Bricks ) 59 Supply Of All Labour, Materials, T&P Etc. All Complete And Construction Of Following Valve Chambers As Per Type Design. 60 Sluice / Wheel Valve ( Surface Box Type ) 61 Sluice Valve ( Masonary Type ) 62 Air Valve 63 Fire Hydrant 64 Supply Of All Labour, Materials, T&P Etc. All Complete And Construction Of Vandal Proof Pillar Type Stand Post At Public Places As Per Type Design And At Locations Identified By Engineer-In Charge. 65 Nala Crossing / Culvert / Road Crossing For More Than 2M Width With Carrier Pipe Including Proper Encasing Of Pipe And Restoring The Drain To Original Condition Inluding Supply Of All Materials, Labour, T&P Etc Complete Upto The Satisfaction Of Engineer-In-Charge 66 Nala Crossing ( Small ) Upto 2M Width With Carrier Pipe And Restoring The Drain To Original Condition 67 Provision Of New Single Brass Tap Ferrule Water House Hold Connection With Fixing Of Saddle ( Electrofusion Tapping Saddle ) For Making Connection With Hdpe Distribution Pipeline Minimum 10M, Di Strap Saddle, Ferrule For Making Connection With Pipes Other Than Hdpe, Connection Fittings, Gm Ferrule Of 15Mm Dia Including Brass Tape With Welded, 20Mm Dia ( Od ) Hdpe Pipe ( Pe-100 / Pn-12.5 ) And 20Mm Dia Od G.I Pipe ( Minimum 1M ) Class B Upto House Holder As Per Type Design Drawings And Including Excavation, Laying And Jointing For Proper Completion Of Workas Per Instructions Of Engineer-In-Charge ( With Making House Connection List With All Data Like Adhar Card / Address Proof, Mobile No., Geotagging Of House Connection With House No. Etc. ) 68 300 Mm Dia.-350Mm Dia 69 200 Mm Dia.-250Mm Dia 70 140 Mm Dia-180Mm Dia 71 90 Mm Dia-110Mm Dia 72 Repair Of Old House Connections In Different Sizes Of Pipes Including Supply, Carting Of Specials, Lowering Them Into Trenches, Cutting, Fixing Them In Proper Alignment And Jointing Including Necessary Excavation For Connection Etc All Complete 73 Provision Of Interconnection In Existing Pipe Network Ac / Pvc / Di / Hdpe Pipe Including Supply, Carting Of Specials, Lowering Them Into Trenches, Cutting, Fixing In Proper Alignment Including Bailing Out Wateretc All Necessary Works Complete Upto The Satisfaction Of Engineer-In-Charge 74 300 Mm Dia.-350Mm Dia 75 200 Mm Dia.-250Mm Dia 76 140 Mm Dia-180Mm Dia 77 90 Mm Dia-125 Mm Dia 78 Provision Of Reinstatement Work For Water House Hold Connection Including Supply Of All Materials, Labour And T & P Etc. Required For Proper Completion Of The Work. 79 Bituminous Road 80 Cement Concrete Road 81 Interlocking Road / Paver 82 Charges To Be Paid For Shifting Of Electricity Poles 83 Rising Main 84 Supply Of Following Sizes ( D.I. ) Pipes For Rising Main Conforming To Latest / Relevant I.S. 8329 / 2000 Specifications With All Jointing Materials Such As Specials Conforming To Latest / Relevant I.S. Specifications, Suitable For D.I Pipes, As Per Is-1239 / 2000 And Is 8329 / 2000 Or Their Latest Amendment Including F.O.R. Destination And All Taxes And Insurance Etc. With Loading, Unloading And Carting Up To Site Of Work, Also Including Supply And Fixing Of Specials All Required For Making Lengths Of These Pipes Complete As Per Instructions Of Engineer -In - Charge. 85 200 Mm Dia K-7 86 Excavation For Pipeline Trenches In Ordinary Soil ( Loam, Clay Or Sand ) Including Lift Upto 1.5M And Lead Upto 50M And Refilling, Watering, Ramming Of Excavted Earth In To The Trenches And Disposal Of Surplus Earth Upto 50M From The Center Of The Trenches. D.I. ( K-7 ) Pipes. Guidelines On Environmental Construction And Demolition ( C&D ) Wastes And Grap Circulated By Central Pollution Control Board 2017 And Its Latest Ammendments Shall Be Adhered To For Excavation Of Trench During Laying Of Pipeline. Surplus Material After Backfilling Shall Be Immediately Removed From Site And Temporary Restoration Shall Be Done To Make Road Motorable 87 Carting From The Following Sizes Of D.I.Pipes ( Class K-7 ) And Specials To The Site Of Work, Lowering Them In To Trenches And Laying True To Alignment And Gradient, Cutting Of Pipes, Making Joints Including Cost Of Jointing Material, Rubber Rings, Labour, T&P Etc Including Hydraulic Testing Of Pipeline. It Includes Making Alignment On City Roads, Making Of Trial Pits To Investigate Location Of Various Undergroung Services Like Telephone Cables, Electric Cables, Existing Water And Sewer Lines Complete Required For Proper Completion Of Work. Only Sbr Rubber Gaskets To Be Used As Per Is 5382 And Is 12820 Including Making Bypass Arrangement. 88 Supply & Fixing Of Following Sizes Of C.I. Double Flanged Sluice Valves As Per I.S. 780 / 1969 Class - 1 F.O.R. Destination Including All Taxes And Insurance. 89 200 Mm Dia K-7 90 Supply Of All Materials, Labour, T & P Etc. And Construct Following Valve Chambers. 91 1 ) Sluice Valve Chambers 92 Dismantling Of Roads For Laying Of Pipe Line Including Sorting Out And Stacking Of Serviceable Materials, Stacking And Disposal Of Unserviceable Materials Upto A Distance Of 50M 93 Bituminous Road 94 Cement Concrete Road 95 Interlocking Road / Paver 96 Reinstatement Of Following Type Of Roads Dismantled During Laying Of Pipe Line Including Supply Of All Materials, Labour And T & P Etc. Required For Proper Completion Of The Work. 97 Bituminous Road 98 Cement Concrete Road 99 Interlocking Road ( 40 % New & 60% Quantity Old Bricks ) 100 Provision Of Road Cutting For Pwd Roads 101 Supply Of All Materials, Labour, And T & P Etc. And Construct R.C.C. M-20 Thrust Blocks. For 200Mm Dia Pipe Includingsupply Of Mild Steel Reinforcement, Its Bending , Fixing And Bending With 0.50Mm Thick Binding Wire, Necessary Centering And Shuttering Including Curing Etc All Complete 102 Supply Of All Labour, Materials And T & P Etc. And Construct Boundary Wallwith Rcc Column As Per Approved Drawing For Oht And Pumping Stations Including Proper Completion Of Work 103 Supply Of All Labour , Materials And T & P Etc .And Provide 3.60 M Wide M.S. Gate And 1 M Wide Wicket Gate With Pillars As Per Department Type Design Drawing. 104 Construction Of 3.5M Wide Cement Interlocking Tiles Of Approved Thickness Approach Road To Oht And Pumping Station Including Preparation Of Subgrade With Lean Concrete 1:6:12, 8 Cm Thick And Sand 5 Cm Thick Supply Of Materials, Labour Etc All Complete 105 Replacement Of Old Damaged 63 Mm Dia Pvc Pipeline With 90 Mm Hdpe Pipe Line Including Supply Of Pipe, Excavation, Carting, Laying, Lowering In Trenches, Jointing With Existing Network Inluding All Labour, Material, T&P At Sections As Approved By Competent Authority Wherever Deemed Necessary & Upto Satisfaction Of Engineer-In-Charge. 106 E & M Works 107 Transportation 108 Transportation, Erection & Dismantling Of Rig Machine 109 Transportation Of Tubewell Assembly 110 Transportation, Erection & Dismantling Of 350 Psi Compressor 111 Transportation, Erection & Dismantling Of 3 Cusec O.P Unit 112 Dc Drilling Upto 200 M 113 Drilling Of 625 Mm. Dia Bore From G.L. To 70 M Bgl. 114 Drilling Of 500 Mm.Dia Bore From 70 M Bglto 100 M Bgl. 115 Drilling Of 500 Mm.Dia Bore From 100 M Bglto 200 M Bgl. 116 Bentonite Clay 117 Flushing Of Bore 118 Electrical Logging Of The Bore 119 Lowering Of Tube Well Assembly And Shrouding Of Pea Gravel 120 300Mm Dia Ms Erw Pipe From G.L. To 65 Mbgl 121 200 Mm.Dia M.S Erwplain / Slotted Pipe From 65 M Bgl To 100 M Bgl 122 200 Mm.Dia M.S Erwplain / Slotted Pipe From 100 M Bgl To 180 M Bgl 123 Supply Of 1.6 Mm To 4.8 Mm Size Pea Gravel Duly Screened And Washed As Per Is 4097 124 Tube Well Assembly : 125 300 Mm.Dia Size 126 200 Mm.Dia Size 127 Developmnet Of Tube Well 128 Development Of Tube Well By 350 Psi Compressor 129 Development Of Tube Well By 3 Cusec O.P. Unit 130 Test : 131 Chemical And Bacteriological Test Of Water Sample From Departmental Approved Lab 132 Pumping Plant & Instrumentation 133 Sitc Of 800 Lpm, 58 M Head, ( Or As Per Requirements Of Site And Instructions Of Engineer Incharge ) Submersiblepump Motor Set With 24M 100 Mm Dia Coloum Pipe, Nrv, Ci D / F Bend 90º, Ci A / F Tee, D / F Pipe ( 1.5 M Long 02 Nos & 1.0 M Long 01 No ) Earthing, Painting, Tools Sets, Wiring Of Pump House Internal & External, Chain Pulley Block & All Pumping Plant Accessories With Nut Bolts And Rubber Packing Etc. 134 Submersible Pump Motor Set 800 Lpm 58 M Head ( Or As Per Requirements Of Site And Instructions Of Engineer Incharge ) As Spare For Scheme 135 3M Long Heavy Duty Coloumn Pipe ( Spare ) 136 Automatic Chlorination System 137 Ce / Ul Certifiedintelligent Smart Energy Meter 138 Motor Operated Actuator With 100 Mm Dia Sluice Valve 139 Ce / Ul Certified Electromagnetic Flowmeter Of Size 100 Mm 140 Soft Starter With Rs485 Port- 400V Class, 22 Kw Rating. 141 Ce / Ul Certified Pressure Transmitter 142 Ce / Ul Certified Hydrostatic Type Sub Soil Water Level Transmitter For Tubewells 143 Ce / Ul Certified Radar Type Level Transmitter For Oht 144 Dg Set : 145 Supplying, Erecting, Testing And Commissioning Of Diesel Generating Set With Alternator Of 40 Kva ( As Per Cpcb-4 Guidelines ) Output Continuous Rating, 3 Phase, 415 V, 50C / S0.8 P. F.A.C Supply, A Totally Enclosed Air Cooled / Liquid Cooled Multi- Cylinder Diesel Engine Developing Suitable Bhp At 1500 Rpm With 10% Overload For 1 Hour In 12Hours, Along With Standard Accessories, Self- Excited, Self-Regulated, Screen Protected Alternator With Static Excitation System Running At 1500 Rpm As Per Is4722-2001 With Voltage Regulation + / - 5 %, With Performance Class G2 And Maximum Fuel Consumption 11.3 Ltr / Hr @75% Loading. Both The Engine And Alternator Direct Coupled On A Common Fabricated Steel Base Frame And Mountedon Anti-Vibrating Pads With Standard Control Panel Comprising Meters, Switchgears, Indicators Connected With Suitable Wires / Cables, The Complete Set Enclosed Incomposite Acoustic Enclosure As Fully Assembled Integral Unit Made Of 16 Swgcrca Sheet, Sound Absorbing Material To Restrict Sound Level Up To 75 Db At 1.0M, Provided With First Filling Of Oil, Diesel Not Less Than 150 Ltr Etc. On Provided M20 Grade Cc Foundation As Per Specificationno. Gen-Dg 146 Supplying, Erecting, Testing And Commissioning Of Microprocessor Based Amf Panel Suitable For Diesel Generating Set Of Above 40 Kva Up To 62.5 Kva Capacity Three Phase, 415 Volts, 50Hz A.C. With All Standard Features, Safeties Etc As Per Specification No. Gen-Amf. 147 Providing Earthing With Galvanized Iron Earth Plate Size 60 X 60 X 0.6 Cm With Funnel With A Wire Mesh For Watering And Brick Masonry Block C.L. Cover Complete With All Materials, Testing & Recording The Results As Per Specification No. Ea-Ep 148 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 3½ Core 50 Sq. Mm. Copper Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Cu 149 Automation Work Of Tubewell 150 Ce&Ul Certified Plc / Rtu In Ip54 Enclosure Suitable To Communicate With Gsm Based Modem Unit With Cpu And Power Supply With Analog And Digital Parameter And Features As Specified, For Each Tubewell / Oht To Store And Transmit Data On Gsm Backbone, Rtu / Plc Designed With Logic To Transfer Data At Multiple Stations As Specified In Tender Technical Specification 151 Gsm / Gprs Based Wireless Communication With 4G Modem For Rtu / Plc Capable To Transfer And Gather Data From Remote Sites To Control Stations All Accessories Included With Signal Enhancer Antenna Made For Pumping Plant Internet Charges As Specified In Tender Technical Specification 152 Auto Phase Reversal Unit Suitble For Above Pumping Plant With Inbuilt Time Delay And Enclosure ( Confirmation To Iec:60947-1 & Iec: 60947-B-1 ) 250 Amp 153 Ce / Ul Certified Pressure Transmitter 154 Ce / Ul Certified Surge Protector For Control Panel 155 Ce / Ul Certified 7 Hmi Touch Screen Suitable To Communication With Plc / Rtu For Local Display And Control Of Process Parameter 156 Complete Cabling For Tubewell Including All Power & Control Cables Of All Equipments At Pump House And Oht 157 Control Panel With Ip-54 Protection Industrial Grade For All Equipments Seprate For Control 24V And Power Equipments 158 Installation, Testing And Commissioning For One Tubewell 159 Trial Run For Three Months Period 160 Lcs Work 161 Ce / Ul & Bis Certified Industrial Grade Led Monitor With Latest Configuration As Per Specification, 65 162 Desktop Pc With I5 / I7 Processor For As Per Specification Mentioned In Technical Bid Document 163 Ce / Ul Certified 3 Kva Ups With Batteries As Per Specificatins Mentioned In Technical Bid Document 164 Full Development Version / Run Time Version Of Required Tags Scada Software With Customization Of Software For Lcs As Per Requirement As Per Specs Mentioned In Technical Bid Document 165 Ce / Ul Certified Local Control Room Plc With Redundant Cpu & Power Supply At Lcs In Ip 54 Enclouser As Per Specifications Mentioned In Technical Bid Document. 166 Gsm Based Wirewless / Broadband / Equipment Communication System For Plc Capable To Transfer & Received Data & Gather Data From Remote Sites To Control Station. All Accessories Included Signal Enhancer Antenna Along With Running Expenses Till Dlp 167 Ce / Ul Certified Firewall For Network Protection 168 Surge Protector For Ethernet Communication Protection 169 Ce / Ul Certified Industrial Grade Ethernet Switch 170 Canon / Hp Or Equivalent Lazer Printer 1018 0R Equivalent 171 Security Serveillance Ip Camera With Recorder 172 Installation, Commissioning And Testing Including Required Furniture, A / C, Etc. 173 Trial Run For 3 Months Period 174 Scadadisplay ( Mcs ) 175 Ce / Ul & Bis Certified Industrial Grade Led Monitor With Latest Configuration As Per Specification, 65 176 Video Wall Media Player Of Same Oem 177 Desktop Pc With I5 / I7 Processor For As Per Specification Mentioned In Technical Bid Document 178 Ce / Ul Certified 5 Kva Ups With Batteries As Per Specification Mentioned In Technical Bid Document 179 Full Development Version Of Required Tags Scada Software With Customization Of Software For Mcs As Per Requirement As Per Specification Mentioned In Technical Bid Document 180 Ce / Ul Certified Master Control Room Plc With Redundant Cpu & Power Supply At Mcs In Ip 54 Encloser As Per Specification Mentioned In Technical Bid Document 181 Ce / Ul Certified Field Gateway Agent For Transfering Data From Mcs To Central Control Room 182 Gsm Based Wirewless / Broadband / Equipment Communication System For Plc Capable To Transfer & Received Data & Gather Data From Remote Sites To Control Station. All Accessories Included Signal Enhancer Antenna Along With Running Expenses Till Dlp 183 Ce / Ul Certified Firewall For Network Protection 184 Surge Protector For Ethernet Communication Protection 185 Ce / Ul Certified Industrial Grade Ethernet Switch 186 Mobile App Facility System Architecture ( Industries Internet Based & Viewed Through Apps For Increased Local & Remote Visibility 187 Canon / Hp Or Equivalent Lazer Printer 1018 Or Equivalent 188 Security Serveillance Ip Camera With Recorder 189 Installation, Commissioning And Testing Including Required Furniture, A / C, Etc. 190 Trial Run For 3 Month Period For Scada Equipments 191 Servo Voltage Stabilizer 40 Kva 192 Trial Run For 3 Months Period Including Chlorination