Tender For Annual Plan-Erath Gp-Anganwadi No 42 Electrification Work In Ward No 8 - Electrification In First Floor And Addl Points In Ground Floor-General Electrical Work., Erathu-Kerala

Government Departments has published Tender For Annual Plan-Erath Gp-Anganwadi No 42 Electrification Work In Ward No 8 - Electrification In First Floor And Addl Points In Ground Floor-General Electrical Work.. Submission Date for this Tender is 11-12-2023. Electrical Maintenance Tenders in Erathu Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

40931085
Tender For Annual Plan-Erath Gp-Anganwadi No 42 Electrification Work In Ward No 8 - Electrification In First Floor And Addl Points In Ground Floor-General Electrical Work.
Open Tender
Indian
Kerala
Erathu
11-12-2023

Tender Details

Tender For Annual Plan-Erath Gp-Anganwadi No 42 Electrification Work In Ward No 8 - Electrification In First Floor And Addl Points In Ground Floor-General Electrical Work.; 1 Part 1-Electrification-List Of Materials Attached Seperately 2 90.2.1.1:Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988, Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1.00 Sq Mm Frlspvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providingswitch Boardmain And Continuous Earthing With No.14 Swg Bare Copper, Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping / Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates ( White ) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And DbS Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. ( Rohs Compliant Modular Accessories ) .Single Control Light Point With 6A, Plate Ceiling Rose - Short Point 3 90.2.1.2:Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988, Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1.00 Sq Mm Frlspvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providingswitch Boardmain And Continuous Earthing With No.14 Swg Bare Copper, Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping / Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates ( White ) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And DbS Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. ( Rohs Compliant Modular Accessories ) .Twin Control Light Point With 6A, Plate Ceiling Rose - Short Point 4 90.2.1.3:Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988, Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1.00 Sq Mm Frlspvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providingswitch Boardmain And Continuous Earthing With No.14 Swg Bare Copper, Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping / Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates ( White ) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And DbS Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. ( Rohs Compliant Modular Accessories ) .Single Control Light Point Without Ceiling Rose - Short Point 5 90.2.1.4:Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988, Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1.00 Sq Mm Frlspvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providingswitch Boardmain And Continuous Earthing With No.14 Swg Bare Copper, Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping / Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates ( White ) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And DbS Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. ( Rohs Compliant Modular Accessories ) .Single Control Ceiling Fan Point With 6 A, 3 Plate Ceiling Rose & With Socket Size Stepped Electronic Regulator. - Short Point 6 90.2.1.6:Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988, Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1.00 Sq Mm Frlspvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providingswitch Boardmain And Continuous Earthing With No.14 Swg Bare Copper, Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping / Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates ( White ) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And DbS Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. ( Rohs Compliant Modular Accessories ) .Combined Plug Point With 6 A, 5 Pin Plug Socket Controlled By 6 A, Switch In The Same Switch Board As That Of Light Points 7 90.2.1.7:Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988, Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1.00 Sq Mm Frlspvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providingswitch Boardmain And Continuous Earthing With No.14 Swg Bare Copper, Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping / Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates ( White ) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And DbS Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. ( Rohs Compliant Modular Accessories ) .Independent Plug - Short Point 8 Od175987 / 2023-2024:Supply And Fixing 9W Led Lamp As Required 9 1.58:Supplying And Fixing Pvc Batten / Angle Holder Including Connection Etc. As Required. 10 90.3.21.3:Supply & Installation Of Light Fittings On C / U Shaped Flat Iron Bracket Supply, Conveyance, Installation, Testing And Commissioning The Light Fittings Of Following Types Made From 0.5Mm Crca Sheet Complete With All Accessories Andlamps Etc. Directly On Wall Using 2 Nos. C / U Brackets Made From 20 X 3 Mm Ms Flat, Painting The Flat Iron Bracket And Giving Connections With Required Length Of 16 / 0.20Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss Or Extending The Original Wiring And Giving Connection Etc. As Required.1200 Mm 1X20w Led Lamp With Box Type Fixture 11 Od175998 / 2023-2024:Supply And Providing 400 Mm Light Duty Plastic Body Wall Mounting Fan Cromptonor Equivalant Make Suitably Mounting On Wall 12 90.4.8:Charges For Cutting Holes Suitable For Accommodating Exhaust Fans Up To 305Mm Sweep Including Plastering Colour Washing Etc. As Required. 13 Od175991 / 2023-2024:Supply, Conveyance, Installation, Testing And Commissioning Of 225 Mm Light Duty Exhaust Fan In The Existing Opening, Fixing Necessary Bolt And Nuts, Making Good The Damages Etc. As Required Including Giving Connections With Required Length Of Suitable Size Pvc Insulated And Pvc Sheathed 3 Core Round Copper Conductor Flex Wire Conforming To Relevant Iss. 14 90.4.1:Supply And Installation Of Suitable Size Ms Rod Type Fan Clamp In The Rcc Slab As Per Is 732 As Required. 15 90.4.5.4:Supply, Installation, Testing And Commissioning Of Ceiling Fan Of Following Sizes Including Wiring The Down Rods Of Standard Length ( Up To 30 Cm ) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required.1200Mm Sweep - Ceiling Fan Complete With Service Value Minimum 4.0 ( Cub Meter / Minute / Watt ) , Air Delivery Minimum 210 ( Cubic Meter / Minute ) , Copper Winding Suitable For 230V / 240V Single Phase Ac Supply 16 90.6.10.1:Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required20 Mm 17 90.6.10.2:Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required25 Mm 18 1.17.2:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.2 X 1.5 Sq. Mm 19 1.17.11:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.2 X 2.5 Sq. Mm 20 1.17.13:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.4 X 2.5 Sq. Mm 21 1.17.20:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.2 X 4 Sq. Mm 22 90.6.6.2:Supply And Drawing Frls Pvc Insulated & Sheathed 650 / 1100 V Grade 3 Core Copper Conductor Flat Cable For Submersible Pump Motor Conforming To Is 694 Part I 1990 As Required Including Giving Necessary Connections Of The Following Sizes.2.50 Sq Mm 23 90.10.3.15:Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required ( Rohs Compliant ) 32A Dp Switch With Indicator 24 1.24.1:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5 / 6 Amps Switch 25 1.24.3:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15 / 16 Amp Switch 26 1.24.4:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5 / 6 Amp Socket Outlet 27 1.24.5:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15 / 16 Amp Socket Outlet 28 1.27.1:Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.1 Or 2 Module ( 75Mmx75mm ) 29 1.27.2:Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.3 Module ( 100Mmx75mm ) 30 1.27.4:Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.6 Module ( 200Mmx75mm ) 31 Od176054 / 2023-2024:Supply, Conveyance And Erection Ofthe Following Sizes Of B Class Gi Pipe In Single Section Across The Wall / Well And Painting With 2 Coats Of Synthetic Enamel Paint Over A Coat Of Zinc Chromate Primer Etc. As Required.40 Mm Dia Gi Pipe 32 Od176055 / 2023-2024:Supply And Installation Of 1 Hp, 220 Volt Submerceble Motor Pumpset In The Existing Well Using Suitable Rope Etc In Positon ( Crompton / Mahindra Or Equivalant ) 33 Od176059 / 2023-2024:Supplying And Fixing Of 25 Mm Or Nearest Sizes Of Suction Hose Along With Pump Set In Position ( Hycon Or Equivalant Make ) 34 2.3.3:Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcbirccb / Isolator12 Way, Double Door 35 2.10.1:Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 36 2.11:Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 37 2.12.1:Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 38 2.14.1:Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 Volts, Residualcurrent Circuit Breaker ( Rccb ) , Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.25 Amps 39 5.4:Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. 40 5.9:Supplying And Laying 25 Mm X 5 Mm G.I Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection / Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required. ( Jointing Shall Be Done By Overlapping And With 2 Sets Of G.I. Nut Bolt & Spring Washer Spaced At 50Mm ) 41 90.16.1.1:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required2.00 Mm Copper Conductor ( 14 Swg ) 42 90.16.1.3:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg ) 43 90.16.2.1:Supply And Laying Of The Following Sizes Of B Class Gipipe Laid 0.6 M Below Ground Level Including Excavating Trench Of Suitable Size And Refilling Etc, As Required.15.Mm Dia. G.I Pipe ( Medium Class ) 44 90.16.5.1:Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.2.00 Mm ( 14 Swg ) 45 90.16.5.3:Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.3.15 Mm ( 10 Swg ) 46 Od176083 / 2023-2024:Charges For Preparation Of Kseb Service Connection Documents For Availing Single Phase Service Connection And Producing To The Consumer Including Test Report Drawing Etc. 47 Od176084 / 2023-2024:Supply And Providing 12X3 Mm Brass Nut And Bolt With Washers In Position Including Drilling Holes 48 Od176085 / 2023-2024:Supply And Providing 25X6 Mm Brass Nut And Bolt With Washers In Position Including Drilling Holes 49 Od176086 / 2023-2024:Supply And Installation Of Dust And Vermin Proof Wall Mounting Meter Box ( 400X300x190mm ) Sintex Make ( Gsmb-4030 ) Or Equivalant Make With Base Plate Suitable To Fix Single Phase Energy Meter And Hrc Fuse Units And Neutral Link On Wall Using Suitable Nut Bolt Etc. 50 Od176087 / 2023-2024:32 A, 2 Way Neutral Links Mounted On Dmc / Smc Base 51 Od176088 / 2023-2024:Supply And Providing 32, Hrc Fuse Base With Suitably Ratedlink 52 Od176089 / 2023-2024:Supply And Providing Suitable Size Anchor Bolt Hook Grouted On Wall For Service Wire

Key Value

Document Fees
INR 555 /-
EMD
INR 2034.0 /-
Tender Value
INR 81353.0 /-