Tender For Provision Of Laundry Plant For Girls Cadets At Rimc Dehradun; 1 Supply, Installing, Fixing & Commissioning Of Industrial Type Front Loading, High Spin 30 Kg Heavy Dutywashing Extractor With Following Specificationsincluding Required Necessary Pipe, Tees, Bends, Elbow, Valves And Electric Connection From The Existing Connection Complete All As Specified And Asdirected. 2 Specification :- 3 Washing Extractor Should Be High Spin With Soft Mount Of 30 Kg Capacity, Electric Heated, Front Loading Open Pocket Type With Stainless Steel Cabinet And Plc Controlled. 4 Capacity ( 1:10 ) 30 Kg Dry Weight Of 100% Cottons Per Charge. ( Inner Cylinder Volume To Be At Least 10 Ltrs For 1Kg Of Dry Linen. ) 5 Outer Cabinet Should Be Stainless Steel Of 304 Quality Front, Sides & Top Covers. S.S. Front Door Interlocked With Drive. 6 Outer Drum Should Be Stainless Steel Of 304 Quality Duly Reinforced To Support Front Door, Bearing Housing, Springs, Electric Motor & Shock Absorbers. 7 Inner Cylinder Stainless Steel Of 304Quality. Dimpled Perforations. Coned S.S. Back-End- Plate With Tapered S.S Bush At The Center And Push Fit Main Shaft For Easy To Dismantle. 8 Suspension : Springs & Hydraulic Shock Absorbers. 9 Bearing Housing Cast Iron One Piece Bearing Housing With Extra Wide Roller & Ball Bearings Packed With Lubricants & Sealed. Self Lubricating Seals For Water Tightness & For Lubricant Tightness Of Bearings. 10 Drive Single Motor With Variable Frequency Drive For Various Speeds For Wash, Distribution, Low, Normal & High Spin Extract. 11 Computer Fully Programmable Microprocessor With At Least 30 Customized Or Preset Processes With Step By Step Lcd Instructions For Cycle Advance, Variable Time Signal, Process Modification & Diagnostic Checks. 12 Soap Dispenser : 5 Compartment In-Built Soap Dispenser For Powder & Liquid Detergents, Each Fitted With Independent Water Solenoid Valve & Pressure Jet. Optional Provision For External Liquid Dozing. 13 Inner Cylinder Dimensions : Ø 900 X 500 Mm Depth. 14 Inner Cylinder Volume : 318 Ltrs. 15 Final Extract Speed / G Force: Atleast 800 Rpm / 321 G. 16 Clear Door Opening: Ø 500 Mm. 17 Electric Motor Size: 5.5 Kw, 415V, 3Phase, Ac. 18 Water Inlet: Ø 25 Mm ( 0.75 Bsp ) Solenoid Valve Operated. 19 Electric Heating Load : 12 / 18 Kw. 20 Drain: Ø 65 Mm ( 2.5 Bsp ) Motorized, Non Clog Chain 21 Dimensions: Width:1300 Mm, Depth:1400 Mm, Height: 1725 Mm 22 Weight: 1380 Kg. 23 Electric Supply : 415V ±5%, 3Phase, 50 Hz, Ac. 24 Makes :- Stefab, Fabcare, Supershine 25 Supply, Installing, Fixing & Commissioning Of Industrial Type Front Loading Drying Tumbler 30 Kg Capacity With Following Specificationsincluding Required Necessary Pipe, Tees, Bends, Elbow, Valves And Electric Connection From The Existing Connection And Complete All As Specified Anddirected. :- 26 Specification :- 27 Electric Heated With Stainless Steel Cylinder, Microprocessor Control, Reversible With Cool Down Feature. 28 Capacity : 30Kg Dry Weight Of 100% Cottons Per Charge. 29 Outer Cabinet Should Be Double Walled For Heat Insulation, Hot Painted. Front & Back Service Only. It Can Be Joined Together For Multiple Installation. 30 Inner Cylinder Should Be Stainless Steel 304 Grade Perforated Inner Cylinder, Back End Plate Reinforced With M.S. Channel / Trunion. 31 Electric Controls Should Be Based On Micro Processor Control For Drying & Cool-Down Time. Auto Digital Temperature Control With Moisture Control & Humidity Sensor. 32 Drive: Main & Idle Drive Through V Belts & Pulleys Running On Self Aligning Ball Bearings Encased In Plummer Blocks. 33 Suction Blower: Aluminum Cast Suction Blower Driven By Independent Blower Motor. Optimized Air Flow. 34 Electric Radiator: Formed Out Of Stainless Steel Heating Elements With Galvanized Rectangular Fins. 35 Lint Screen : Self Cleaning Lint Screen Removable From The Front. 36 Inner Cylinder Dimensions : Ø 950 X 850 Mm Depth. 37 Inner Cylinder Volume : 602 Ltrs. 38 Clear Door Opening : Ø 650 Mm. 39 Drive Motor : 0.75 Kw, 415V, 3-Phase, Ac.Isi Marked Or Equivalent. 40 Blower Motor : 0.75 Kw, 415V, 3-Phase, Ac.Isi Marked Or Equivalent. 41 Exhaust : 210 X 210 42 Electric Heating Load : 24 Kw. 43 Dimensions:Width:1050Mmxdepth:1425Mmxheight:1980Mm. 44 Weight : 570 Kg. 45 Electric Supply : 415V ±5%, 3-Phase + N, 50 Hz Ac. 46 Makes:- Stefab, Fabcare, Supershine 47 Supply, Installing, Fixing, Testing & Commissioning Of Vacuum Ironing Table With Following Specificationsincluding Required Necessry Pipe, Tees, Bends, Elbow, Valves And Electric Connection From The Existing Connection Complete All As Specified Anddirected.:- 48 Specification :- 49 Rectangular Table Top Of Size 1200X750mm With Centrifugal Suction Along With Extended Exhaust Duct With Rack & Concealed Lighting Device 50 Main Body: Metallic Hot Painted. All Components To Be Easily Accessible. 51 Tabletop : Densely Perforated Aluminum Plate Padded With High Porosity & Heat Resistant Silicon Padding & Polyester Cover. 52 Table Heater: 1Kw Thermostatically Controlled Stainless Steel Tubular Heater Fitted Below The Aluminum Table Top To Keep The Padding Dry At All Times. 53 Suction Blower: Heavy Duty Centrifugal Blower Driven By Independent 0.37Kw Blower Motor Activated By Spring Loaded Full Length Foot Pedal. 54 Exhaust :Extended Exhaust Duct With Full Length Rack & Concealed Lighting Device. 55 Dimensions Width :1430Mm, Depth:1090Mm, Height:1300Mm. 56 Weight : 120 Kg. 57 Electric Supply : 415V ±5%, 3Phase, 50 Hz, Ac. 58 Makes:- Stefab, Fabcare, Supershine 59 Supplying, Installing, Commissioning & Testing Of Electric Steam Generator Electric Fully Automatic With Following Specificationsincluding Required Necessary Pipe, Tees, Bends, Elbow, Valves And Electric Connection From The Existing Connection Complete All As Specified Anddirected.:- 60 Specification 61 Capacity Of Steam Generator Should Be 8 Kg Per Hour Capacity Withelectric Portable. Fully Automatic With Pump Along With Stainless Steel Pressure Vessel. Automatic Steam Release Safety Plug. Audio Video Signal For Low Water Level. Steam Solenoid Valve With Flow Control Knob. Built In Water Storage Tank. 62 Steam Pressure-: 8 Kg / Cm² 63 Pressure Vessel:- 12 Ltrs. Capacity. 64 Water Feed Pump:- 700 Watts. 65 Water Level Controller:-Float Type With Stainless Steel Float Ball. 66 Pressure Control Switch:- Dia Phragm Type With Pressure Differential Of 0.5 Kg. 67 Electric Heating Load:- 6 Kw With Option To Use 2, 4 Or 6 Kw. 68 Water Storage Tank:- 25 Ltrs 69 Dimensions:- Width - 350Mm, Depth - 600Mm, Height - 870Mm. 70 Weight:- 110 Kg. 71 Electric Supply:- 415V ±5%, 3Phase, 50 Hz, Ac. 72 Makes:- Stefab, Fabcare, Supershine 73 Supply, Installing, Testing And Commissioning Of High Spin, Front Loading, Soft Mount Hydrocarbon Dry Cleaning Machine 15Kg With Following Specificationsincluding Required Necessary Pipe, Tees, Bends, Elbow, Valves And Electric Connection From The Existing Complete All As Specified Anddirected.:- 74 Specification 75 Dry Cleaning Machine Should Be Of Capacity 15Kg. High Spin, Soft Mount. Front Loading, Open Pocket. Multi Solvent. Computer Controlled. Up To 80% Solvent Recovery. 76 Capacity : 15Kg Dry Weight Per Charge. 77 Type Of Solvent : Mto / Hydrocarbon Solvent. 78 Main Body & Base Tanks: Formed Out Of Steel Sheets & Plates Welded Construction. 79 Inner Cylinder : Stainless Steel Perforated Of S.S. 304 Quality. 80 Soft Mount Top Suspension: Dynamically Tuned Top Suspension With Coil Springs &H Ydraulic Cushions Should Absorb Even Severe Out-Of-Balance Load Vibrations. No Special Foundations Shall Be Required. 81 Vfd Drive: Single Motor With Variable Frequency Drive ( Vfd ) For Various Speeds Of Wash, Distribution, Low & Final High Spin Extract. 82 Computer : Programmed Computer Should Provide Option So Flight Shades, Dark Shades, Gentle Wash, Strong Wash, Normal Spin, High Spin, Short Cycle & Full Cycle. Step By Step Lcd Display Should Provide Cycle Status & Variable Time Signal. 83 Inner Cylinder Dimensions : Ø 700 X 425 Mm Depth. 84 Inner Cylinder Volume 163 Ltrs. 85 Base Tank I : 150 Ltrs. Solvent Transfer By Motorized Pump. 86 Base Tank Ii : 150 Ltrs. Solvent Transfer By Motorized Pump. 87 Drive Motor Size: 1.5 Kw. 88 Solvent Pump I: 0.37 Kw. 89 Solvent Pump Ii: 0.37 Kw. 90 Filter I: Surface Area : 9400 Sq.Cm. Cartridge Filters. 91 Filter Ii: Surface Area : 9400 Sq.Cm. Cartridge Filters. 92 Dimensions: Width:1580Mm, Depth:1100Mm, Height:1750Mm. 93 Weight: 760 Kg. 94 Electric Supply : 415V ±5%, 3Phase, 50 Hz, Ac. 95 Makes:- Stefab, Fabcare, Supershine 96 Supply Of Movable Stainless Steel Trolley Of Minimum Size 850 Mm ( W ) X 650 Mm ( D ) X 800 Mm ( H ) Havingcarrying Capacity 50 Kg With Two Shelves, Mounted On 4 Nos Swiveling Type ( Ball Bearing ) Rubber Wheels Complete All As Oem Recommendation Complete All As Specified Anddirected. Makes:- Stefab, Fabcare, Supershine 97 Supply Of Movable Stainless Steel Trolley Of Minimum Size 850 Mm ( W ) X 650 Mm ( D ) X 1680 Mm ( H ) Havingcarrying Capacity 50 Kg With Two Shelves, Mounted On 4 Nos Swiveling Type ( Ball Bearing ) Rubber Wheels Complete All As Oem Recommendation Complete All As Specified Anddirected. Makes:- Stefab, Fabcare, Supershine 98 Supplying, Fixing, Jointing And Testing Galvanised Steel Water Tubing Medium Grade ( Isi Marked ) With All Fittings ( Isi Marked ) Such As Bend, Elbow, Socket, Reducer Etc Fixed To Walls And Ceilings Or Laid In Floors Complete All As Specified Anddirected For The Following Sizes: - 99 ( A ) 50Mm Bore 100 ( B ) 40Mm Bore 101 ( C ) 32Mm Bore 102 ( D ) 25Mm Bore 103 ( E ) 15Mm Bore 104 Supply & Fixing Sheet Metal Enclosure, Triple Pole & Earth Enclosure With Interlocked Switched Socket & Surface Mounting Box Ip55 ( 3P+E ) Three Pin & Earth Plug And Socket With Triple Pole Mcb C Curve63 Amp, 415 Volts, 10 KaC Curvecomplete All As Specified And Directed. 105 Supplying And Fixing Gun Metal Gate Valve Flanged Type Is 778, With Iron Wheel Head Screwed Both Ends And Fixed To Pipe Complete All As Specified And Directed Of Following Sizes. 106 ( A ) 50Mm Bore 107 ( B ) 40Mm Bore 108 ( C ) 25 Mm Bore 109 ( D ) 15 Mm Bore 110 M&L For Point Wiring With 1.5 Sqmm ( Nominal Area ) Pvc Insulated And Unsheathed Single Core Cable 1100 Volts Grade With Stranded Copper Conductor In And Including Pvccasing And Capingincluding Accessories Along With Continuous Earth Wire 1.5 Sqmm Pvc Insulated, Unsheathed Stranded Copper Conductor Cable And Connected To Common Earth Dolly, With And Including 1.6 Mm Thick Cadmium Plated Sunk Ms Pressed Steel Terminal Boxes With 3.0 Mm Thick Hylam Sheet Cover Fixed With Brass Screw Complete With All Accessories For One Light Point / Fan Point Controlled By One, One Way Switch. 111 ( A ) One Light / Fan Point Controlled By One Switch. 112 ( B ) One 5 Pin Socket Outlet 5 Amps Controlledwith One Switch On The Same Board. 113 ( C ) One 5 Pin Socket Outlet 5 Amp Controlled By One Switch On Independent Board. 114 All As Per Item No 11 But With 2.5 Sqmm Multi Strand Copper Conductor Cable For One 15 Amp Socket Outlet Controlled By One Switch On Independent Board And 1.5 Sqmm Pvc Insulated Multi Strand Copper Conductor Cable As Continuous Earth Wire Complete. 115 S&F Switch Piano Flush Button Single Pole One Way 5 Amp Complete All As Specified Anddirected. 116 S&F Socket Outlet, 5 Pin, 6 Amp2 In 1, Flush Type, Universal Complete All As Specified Anddirected. 117 S&F Socket Outlet 2 In 1, 5 Pin, 5 And 15 Amp Flush Type Complete All As Specified Anddirected. 118 S&F Switch Piano Flush Button Single Pole One Way 15 Amp Complete All As Specified Anddirected. 119 S&F Ceiling Rose 3 Terminal / Pvc / Polycarbonate, Isolated Body Complete All As Specified Anddirected. 120 S&F Fan Regulator Stepped Type Electronic Fan Regulator Flush Type On The Existing Phenolic Laminated Sheet Etc As Reqd Complete All As Specified Anddirected. 121 S&Fangular Lamp Holder Including 9W / 12W, Pvc / Polycarbonate Type With Back Plate Suitable For Angular Fittings Complete All As Specified Anddirected. 122 S&F Led Tube Light Fitting Of Led 20 Wincluding Required Length Of 1.5 Sqmm Pvc Multi Stranded Copper Conductor Toelectrical Connection From Ceiling Rose To Connector Of Led Fitting Including Testing On Complete All As Specified Anddirected. 123 Sheet Metal Enclosure Mcb Db, Double Door , 08 Way Spn, 240 Volts With 200 Amps Rated Bus Bar With Blanking Plates Wherever Required Complete All As Specified Anddirected. 124 S&F Mcb Single Pole And Neutral 240 Volts, 25 To 40 Amps Complete All As Specified Anddirected. 125 S&F Mcb Single Pole 240 Volts, 6 To 32 Amps Complete All As Specified Anddirected. 126 Earthing Complete Formachinery Equipment Installed At Power House / Sub Station With Galvanized Iron Earth Plate Electrode 600Mm X 600Mm X 6Mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Metres Deep Below Normal Ground Level ) Vertically, With Top Edge Of Plate Not Less Than 1.5 Metre Below Normal Ground Level Connected To Gi Strip 25Mm X 4Mm Main Earthing Leadby Means Of Bolts, Nuts, 127 Check Nuts And Washers Of Galvanised Iron And Protected With 32Mm Dia Light Grade Gi Pipe All As Shown In Electrical Plate No 3 Of Mes Schedule Part-I Connecting To Earthing Test Point & To Main Switch Board Andtesting On Completion With And Including Necessary Excavation And Earth Work In Any Type Soil, Earth Lead Connected To Earth Test Point & To Main Switch Board Etc With & Including Adequate Quantity Of Charcoal Dust And Common Salt, Test Point, Pcc ( 1:3:6 ) Type C-1 ( Using 20Mm Gradedcrushed Stone Aggregate ) For Earth Pit With 40 X 40 X 6Mm Mild Steel Angle Iron Frame For Cover, Internal Surface Of Concrete Shall Be Given 10Mm Thick Plaster In Cm 1:4, Pre Cast Rcc ( 1:2:4 ) Type B-1 ( Using 20Mm Graded Crushed Stone Aggregate ) 40Mm Thick Cover, Reinforced With 8Mm Dia Deformed Or Tmt Bars 3 Nos Both Way With 12Mm Dia Round Bar Handle, Gi Medium Grade Watering Pipe 20 Mm Dia With Funnel And Wire Mesh And 40Mm Dia Gi Light Grade Earth Lead Protection Pipe Etc Complete All As Specified And Directed. Note: ( I ) Cost Of Gi Strip 25X4mm And 32 Dia Medium Grade Up To 7.5 Mtrs Is Included In The Rate Quoted Of This Item. ( Ii ) If The Desired Earth Resistance Is Not Found Within Permissible Limit Shall Be Redone By The Contractor At No Extra Cost. 128 Supply And Fixing Earth Continuity Conductor Or Main Earth Lead Duly Mounted On Epoxy Type Insulators Fixed To Wall On Batten, Clamps, Cable Tray Or Drawn In Heavy Duty Conduit Pipe Fixed Wall Along With Connected Earthing Strip To All Installed Machineries / Equipment’S Of Laundry Plant Along Withthe Wall Necessary Connection To Main Earth For Loop Earthing As Required By 25X3 Mm Aluminium Strip Complete All As Specified And Directed. 129 Supply, Laying, Fixing & Testing Armoured Cable Size 16X4 Sqmm Pvcbedded Electric Copper Cable Multi Stranded Conductor 1100 Volt Grade 650 / 1100V Complete All As Specified And Directed. 130 M&L For Sub Main Wiring With 2 Runx 6 Sqmm + 6 Sqmm Earth Wire Single Core Pvc Insulated Cable Unsheathed Multi Stranded Copper Conductor Lt 1100 Volts Grade Frls Cable ( Isi Marked With Valid Cml No ) Drawn In & Including Pvc Conduit Of Dia Not Less Than 25Mm In Concealed ( Isi Marked With Valid Cml No ) Including Its All Fittings / Accessories Complete All As Specified Anddirected. 131 Supply And Laying Xlpe Insulated Galvanised Steel Strip Or Wire Armoured Electric Power Cable With Stranded Aluminium Conductor 1100 V Gradeof Size 95 Sqmm 3.5 Core After Cutting To Required Length With Necessary Glands, Nuts, Bolts, And Lugs Complete All As Specified And Directed. 132 Excavation In Trenches Soft / Loose Soil Not Exceeding 1.5 Mtr Wide And Not Exceeding 1.5 Mtr In Depth And Getting Out Excavated Soil / Sand / Unsv Lt Cable For Laying Of Cable And Getting Out Complete All As Specified Anddirected. 133 Supply & Laying Sand Coarse Dry As In Cushioning Of Underground Electric Cable In Trenches, Laid To A Uniform Thickness Of 23Cm ( 15Cm Under The Cable & 8Cm Over The Cable ) And Gently Punned Down To 18Cm Thickness All Complete All As Specified And Directed. Note :- Only Punned Down Sand Thickness 18Cm Shall Be Measured And Paid 134 Returning Filling In Including Spreading Leveling Watering And Well Ramming In Layers Not Exceeding 25 Cm In Hard / Loose Soil Complete All As Specified Anddirected. 135 Removing Excavated Material Not Exceeding 50 Mtr And Depositing Where Directed At A Level Not Exceeding 1.5 Mtr Above The Starting Point Complete All As Specified Anddirected. 136 M&L For Laying Reinforced Precast Concrete Cable Cover, Class Lv, Type I, Flat, Size 250 Mm X 150Mm X 40Mm To U / G Cable Laid Dry Flat Over The Cable With Width Equal To Length Of The Cable And Abutting Each Other With Gap Between Adjacent Slab Not Exceeding 10Mm Over Under Ground Cable For Cable Protection In Trenches Complete All As Specified Anddirected. 137 Cutting Existing Road / Hardstand Of Any Type By Using Crow Bar Chisel Up To Adepth Of 30 Cm For Laying Gi Pipe Including Making Good The Surface By Returning Filling Watering Ramming In Layers 150 Mm Thick Pcc 1:2:4 Over 200 Mm Thick Hard Core Of Broken Bricks / Stones Over Returning Filling Watering Ramming In Layers Not Exceeding 25 Cm Thick Complete All As Specified Anddirected. 138 M&L For Gi Tubing Light Grade ( Isi Marked ) With All Fitting / Accessories For Protection Of Cable On Pole / Wall And Under Road Crossing Including Clamps, Nut Bolt Etc All As Specified And Directed Ofsize 50Mm Diacomplete All As Specified Anddirected. 139 Supply, Installing, Commissioning And Testing Of Lt Panel / Outdoor Kiosk Type, Factory Made, Weather And Vermin Proof Fixed On And Including Ventilation And Louvers Arrangement, Pcc ( 1:2:4 ) Type B-1 In Foundation Of Required / Suitable Size And As Directed At Site With Angle Iron Frame Of Size 40X40x6mm, 3 Phase, 4 Wire, 415 Volts, 50 Hz, Fabricated Out Of 3.15 Mm Thick Ms Sheet Including Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer And Keeping Adequate Working Space Inside The Box ( Outer Width Of The Box Not Less Than One Inch ) And Double Door Be Provided With Proper Hinged And Sliding Door Handle Including Locking Arrangement As Directed And Before Manufacturing The Panel And The Same Have The Following Electric Controls. 140 Comprising Of The Following. 141 Incomer :– 142 ( I ) 320Amp 4P On Load Change Over Switch - 1 Nos 143 ( Ii ) Mccb – 1No 320A 4P Mccb – 1Nos 144 ( Iii ) Ryb Indication Lamps – 1Set 145 ( Iv ) Digital Type Multifunction Meter – 1Set Copper Bus Bar Rated For 500A 146 Outgoings. 147 ( I ) 160 Amp 4P Mccbs – 2 Nos 148 ( Ii ) 100 Amp 4P Mccbs – 1 Nos 149 ( Iii ) 63 A 4P Mccbs–1 Nos 150 Floor Mounting Type With Canopy.