Improvement Electrical Installation And Fans In Malaria Circle Office At Je Maintenance Office C-Block In Ward No. 232 Yamuna Vihar Under Shahdara ( North ) Zone; 2 Od16628 / 2023-2024:1.10.3 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required Group C 3 Od16629 / 2023-2024:1.15.3 Rewiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable As Earth Wire In Existing Surface / Recessed Steel / Pvc Conduit Including Dismantling As Required.Group C 4 Od16630 / 2023-2024:1.7.4 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.3 X 6 Sq. Mm 5 Od16631 / 2023-2024:1.7.3 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.3 X 4 Sq. Mm 6 Od16632 / 2023-2024:1.7.2 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.3 X 2.5 Sq. Mm 7 Od16633 / 2023-2024:1.23.4 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box / Cover Including Connections Etc. As Required.3 Pin 5 / 6 Amp Socket Outlet 8 Od16634 / 2023-2024:1.23.1 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box / Cover Including Connections Etc. As Required.5 / 6 Amps Switch 9 Od16635 / 2023-2024:1.30 Supplying And Fixing Metal Box Of 180Mm X 100Mm X 60Mm Deep ( Nominal Size ) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 A Socket Outlet And 15 / 16 A Piano Type Switch, Connections, Painting Etc. As Required. 10 Od16637 / 2023-2024:2.3.2 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcbirccb / Isolator8 Way, Double Door 11 Od16638 / 2023-2024:2.10.1 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, Ccurve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole 12 Od16639 / 2023-2024:2.12.1 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40Amps 13 Od16640 / 2023-2024:19.1 Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cm / M / W ) Minimum 6.00, Air Delivery Minimum 210 Cum / Min , 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. 14 Od16641 / 2023-2024:1.48 Supplying And Fixing Extra Conduit Down Rod Of 20 Cm Length G.I. Pipe 15 Mm Dia, Heavy Gauge Including Painting Etc. As Required. ( Note : More Than 5 Cm Length Shall Be Rounded To The Nearest 10 Cm And 5 Cm Or Less Shall Be Ignored ) 15 Od16642 / 2023-2024:7.7.1 Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required.Upto 35 Sq. Mm ( Clamped With 1Mm Thick Saddle ) 16 Od16643 / 2023-2024:7.6.1 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required.Upto 35 Sq. Mm 17 Od16644 / 2023-2024:5.12 Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required 18 Od16645 / 2023-2024:5.2 Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal / Coke And Salt As Required 19 Od16646 / 2023-2024:1.50.1 Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage Connection Testing, Commissioning Etc. As Required.Upto 450 Mm Sweep 20 122.1.2:Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-2C*6 Sqmm 21 122.1.47:Supply Of 250 Mm ( 10 Inch ) Sweep 1250 Rpm Exhaust Fan Fresh Air Type Complete With Shutter Blades Etc. As Required. 22 122.2.2: P / Fhot Press Sheet Mouldedcompound ( Smc ) Fire Retardant ( Temp. Resistance Up To 200 C ) , Ip 55 Weather Proof Polebox Of Innerdimension 200X160x98mm ( Ns ) Complete With Suitable Arrangement For Fixing Of 2 Nosof 6 To 32 Amp Single Pole Mcb & 63 Amp. Doublepole Isolator ( Mcb / Isolator Excluded ) Withneutral Link Duly Shorting On Din Channel With2 Nos Of Ms Clamps With Ss Back Plateofsuitable Size With Danger Monogram Property Printed On The Coveretc Asreqd. Asreqd. 23 122.2.29:Sitc Of 100W Led Flood Light Luminiare Fitted With Lens, Made Of Pressure Die Cast Aluminium Housing & Toughened Glass Cover Complete With The Following Specification As Reqd With Ip 66 Protection ( A ) Total System Wattage =100 Watt + / - 5% ( B ) Luminaire Efficacy>=100 Lm / W ( C ) Power Factor>=0.95 ( D ) Protection Class- Ip-66 24 122.2.39:S / I / T / C Of Led Tube Type Luminaire 20 Watt Rating Complete With Polycarbonate Housing Batten Integrated Electronic Driver Prewired With High Efficient Leds With The Following: ( A ) Total System Wattage 20 Watt + / - 5% ( B ) Luminous Efficacy Lumens / Watt >=95 ( C ) Power Factor >=0.95 25 122.2.4:Sitcof Pillar Box Size 900 Mm X 450Mm X 250Mm Suitable For Mounting Incomer Of 250 A Mccb / Main Switch 4 Pole And Energy Meter 3 Phase Complete With Eluotropic Grade Aluminium Bus Bar Of Size 25Mm X 19 Mm Mounted On Galvanized M. S. Body Power Quoted Pilferage Proof Smc Door Duly Welded With S.S. Withrain Cover Size 40Mm X 40Mm X 5Mm X 600Mm Height In Cutting 300 Mm Height Below Groundand Covered With Shode Proof Smc Sheet Of 3 Mm As Required. 26 122.2.176:Supplying & Installation Of Hot Cold & Normal Floor Standing Top Loading Water Dispenser With Cooling Cabinet Fridge Cold Water Storage Capacity Up To 3.5 Ltr With Hot Water Storage Capacity Up To 1 Ltr As Required. 27 Od16661 / 2023-2024:2.12.2 Supplying And Fixing Following Rating, Double Pole, 240 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63A 28 Od16662 / 2023-2024:2.1.2 Providing And Fixing Following Capacity Tp&N Disconnector Fuse Switch Unit Inside The Existing Panel Board With Isi Marked Hrc Fuses Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required. 29 Od16663 / 2023-2024:2.3.1 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcbirccb / Isolator6 Way, Double Door