Repairing / Replacement Work Of Defective / Vandalised Electrical Items Required To Start The Operation Of Buses At Kharkhari Nahar Dtc Bus Depot.- 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 2 Group C 3 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 4 Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 5 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 6 3 X 1.5 sq. mm 7 3X 2.5 sq. mm 8 3X 4 sq. mm 9 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 10 5/6 A switch 11 15/16 A switch 12 3 pin 5/6 A socket outlet 13 6 pin 15/16 A socket outlet 14 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 15 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 16 3 Module (100 mmX75 mm) 17 12 Module (200 mmX150 mm) 18 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 19 125 A, 36kA, FPMCCB 20 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 21 8 way (4 + 24), Double door 22 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 23 Single pole 24 Single pole and neutral 25 Triple pole 26 Triple pole and neutral 27 Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 28 63 A 29 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 30 Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A, “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 31 Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. 32 For 8 way, Double door SPN MCBDB 33 Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. 34 For 8 way, Double door TPN MCBDB 35 Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. 36 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 37 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 38 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. 39 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 40 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 41 3½ X 50 sq. mm (35 mm) 42 Supply of XPLE insulated PVC sheathed AL conductor cable 1.1 KV grade conforming to IS-7098 of size 3.5X50 sq. mm. 43 S/I/T/C of LED tube fitting 20 watt 44 S/I/T/C of Ceiling Fan 48” 45 Dismantling work of old/Existing electric fittings as required 46 S/I/T/C of LED flood Light 100 watt IP66 47 S/I/T/C of Sleek Surface mounted downlight LED Fitting round 6500K,12 Watt 48 Repairing ofDBs, LT Panel including wiring, joints, MCB etc as required as per site 49 Supply ofthree phase5HP, 3.7 KW Horizontal Openwell Submersible pump 50 Supply of three phase submersible pump controllers (with single phase preventer) for three phase 5Hp, 3.7KW rating 51 Supply of size 3 core 2.5Sq. mm. flat cable for submersible pump motor 52 Supply of CPVC column pipe 40mm dia (1.5 inch) 53 Supply of Elbow 90degree 40 mm dia (1.5 inch) 54 Supply of Male Threaded Adapter Plastic 40 mm dia (1.5 inch) 55 Supply of Union 40 mm dia (1.5 inch) 56 Installation and commissioning of Openwell submersible pump motor with pump controller including all wiring connections etc as required. 57 S/I/T/C of 600mmIndustrial Wall fan 1440 RPM 58 S/I/T/C of 300mmExhaust fan 1400 RPM 59 (+)Add prevailing cost index @ 31.27% On DSR-2016 rate) 60 (-)@9.5% below on (DSR-2016 Rate+Add prevailing cost index @ 31.27%