}

Tender For Up-Gradation Of Booster Under Mmc-I At Nsg Camp , Manesar, manesar-Haryana

Government Departments has published Tender For Up-Gradation Of Booster Under Mmc-I At Nsg Camp , Manesar. Submission Date for this Tender is 08-12-2023. Foundation Work Tenders in manesar Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

40842562
Tender For Up-Gradation Of Booster Under Mmc-I At Nsg Camp , Manesar
Open Tender
Indian
Haryana
Manesar
08-12-2023

Tender Details

Tender For Up-Gradation Of Booster Under Mmc-I At Nsg Camp , Manesar; 1 Supplying And Laying Of Following Sizedwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc.Conforming Tois 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc.Direct In Ground ( 75 Cm Below Ground Level ) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc., Complete As Required. 2 120 Mm Dia ( Od-120 Mm & Id-103 Mm Nominal ) 3 200 Mm Dia ( Od-200 Mm & Id-175 Mm Nominal ) 4 The Road Crossings Of Power Cablethrough Trenchless Boring.Trenchless Horizontal Boring Using Manual / Machine Moling Techniqueat 0.75 Metre Below The Ground Level For Following Size Pipes, Including Survey Of Under Ground Utilities, Excavation Of Pits, Moling With The Hole Size Not Exceeding 20% Of The Pipe Dia, Backfilling, Compaction And Restoration Of The Pits To Original Condition Etc. As Required.The Rates For Moling, As Indicated Are Inclusive Of Excavation Of Pits, Backfilling, Compaction Andrestoration Of The Pits To Original Condition.Any Damages Occurred To Other Utilities During The Moling Operation Shall Be Immediately Notified And Rectified By The Contractor Without Any Cost Implication To The Department.The Length Of The Hole ( Excluding The Sizes Of The Pits On Both Ends ) Shall Be Considered For The Measurement Of Moling Length. However, Intermediate Pits Will Consider In The Moling Length.I ) Upto 200 Mm Dia Dwc Hdpe / G.I. / Pvc 5 Providing, Laying And Fixing Following Dia G.I. Pipe ( Medium Class ) In Ground Complete With G.I. Fittings Including Trenching ( 75 Cm Deep ) And Re-Filling Etc. As Required ( Zenith / Tata / Jindal-Hisar / Prakash- Surya Make ) 6 80 Mm Dia Nominal Bore 7 150 Mm Dia Nominal Bore 8 Supplying And Laying Of One Number Aluminium Conductor, Xlpe Insulated, Pvc Sheathed, Armoured Power Cable Of 1.1 Kv Grade , Confirming To Is : 7098 ( Part-1 ) 1988 Of Following Size Direct In Ground Including Excavation And Refilling The Trench Etc As Required, But Excluding Sand Cushioning And Protective Covering. 9 3.5 X 120 Sq. Mm 10 3.5 X 400 Sq. Mm 11 Supplying And Laying Of One Number Aluminium Conductor, Xlpe Insulated, Pvc Sheathed, Armoured Power Cable Of 1.1 Kv Grade , Confirming To Is : 7098 ( Part-1 ) 1988 Of Following Size In The Existing Rcc / Hume / Metal Pipe As Required. 12 3.5 X 120 Sq. Mm 13 3.5 X 400 Sq. Mm 14 Supplying And Laying Of One Number Aluminium Conductor, Xlpe Insulated, Pvc Sheathed, Armoured Power Cable Of 1.1 Kv Grade , Confirming To Is : 7098 ( Part-1 ) 1988 Of Following Size In The Existing Masonry Open Duct / Along Pole / Loose For Connections Etc As Required. 15 3.5 X 120 Sq. Mm 16 3.5 X 400 Sq. Mm 17 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. [ Make-Comet / Hex / Dowells / Jainson ] 18 3½ X 120 Sq. Mm ( 45Mm ) 19 3½ X 400 Sq. Mm ( 82Mm ) 20 Supply, Installation, Testing And Commissioning Of Outdoor Type Totally Enclosed, Dust And Vermin Proof, Pedestal Mounted Inspection Box / Junction Box Of A Suitable Size But Not Less Than 600 Mm Wide X 900 Mm Height X 450 Mm ( Deep ) Fabricated From 2 Mm Thick Crca Sheet Steel Having Front And Back Openable Doors With Locking Arrangement On Both Sides, Tapered Top ( Roof ) , Including Detachable Cable Gland Plates Made Of 3 Mm Thick Crca Sheet, Including Pre-Paint Treatment, Phosphating And Powder Coating By Approved Siemens Grey Paint, Consisting Of 500 Amps 4 Strip Aluminium Bus Bars With Heat-Shrinkable Coloured Sleeves And Including Frp / Dmc / Smc Bus Bar Supports At Required Intervals, Etc. As Required, Suitable For Operation On 433 Volts, 50 Hz, 3-Phase, 4-Wire A.C. Supply System, The Entire Panel Shall Have One Common G.I. / Aluminium Bar Of Size 25 Mm X 5 Mm At The Rear With 2 Earth Studs Or Terminals, A Danger Notice Plate Fixed, Etc., Complete As Required. The Feeder Pillar Should Be Complete With A Mounting Frame Made Of 50 Mm X 50 Mm X 6 Mm Angle Iron With 900 Mm Long Legs. The 4 Legs Of The Feeder Pillar Shall Be Erected On A Suitable Size 1:3:6 Cement Concrete ( 1:3:6 Cement; 3 Sand; 6 Graded Stones Of 20 Mm Size ) Pedestal Having 900Mm Of Depth ( 600Mm Below Ground And 300Mm Above Ground ) . 21 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. 22 Providing And Fixing 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. 23 Providing And Fixing 25 Mm X 5 Mm G.I. Strip On Surface Or In Recess For Connections Etc. As Required. 24 Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal / Coke And Salt As Required. 25 Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required. 26 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required. 27 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface / Recessed Conduit / Submain Wiring / Cable As Required. 28 Supplying And Making Cable Route Marker With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) Of Size 60 Cm X 60 Cm At The Bottom And 50 Cm X 50 Cm At The Top With A Thickness Of 10Cm Including Inscription Duly Engraved As Required. 29 Panel No 01-Booster No 01Fabrication, Supply, Installation, Testing, And Commissioning Of Electrical Control Panel Of Cubical Construction, Floor-Mounted Type, Fabricated Out Of A 2 Mm Thick Crca Sheet With Enclosure Protection Class Ip 42, Suitable For Operation On A 415-Volt, 3-Phase, 50 Hz, 4-Wire A.C. Supply System, Dust- And Vermin-Proof, Powder-Coated In An Approved Siemens Gray Shade After 7 Tank Pre-Treatment Processes. The Panel Shall Be Compartmentalized Type With Hinged Lockable Doors, Detachable Cable Gland Plates Made Of 3 Mm Thick Crca Sheet, Cable Alleys Of Suitable Size On Both Sides For Cabling Routing, Openable Type Rear Cover And Complete With 4 Strips Of Aluminium Bus Bars Of 400 Amps Capacity With Heat-Shrinkable Coloured Sleeves And Frp / Dmc / Smc Bus Bar Supports At Required Intervals, Control Terminals, And Suitable Sized Terminal Blocks For Incoming And Outgoing Cables, Including Providing And Fixing Interconnection From Busbars To Switch Gears And Up To Terminal Blocks With Suitable Sized Insulated Aluminium Conductor / Solid Aluminium Strip And Control Wiring With Suitable Sized Insulated Copper Conductor Cable, Including Suitable Size M.V. Danger Board Fixed On Panel. The Entire Panel Shall Have One Common Copper Bar Of Size 25 Mm X 5 Mm At The Rear With Two Earth Studs / Terminals. 30 The Panel Shall Be Supplied With A Bottom Base Ms Channel, Not Less Than 100 Mm X 50 Mm X 5 Mm Thick. Suitable Size Of M.V. Danger Boards Shall Be Fixed On Panel. The Panel Base Should Have Four 300 Mm Long Legs ( Made Of Angle Irons 50 X 50 X 6 Mm Or Other Suitable Means ) To Raise The Panel From The Floor, And A Removable 2 Mm Thick Powder-Coated Crca Sheet Cover Must Be Provided On Four Sides Of The Pedestal. The Base Frame Of The Panel Should Be Grouted Into The Floor With Four 12Mm Dia X 200Mm Long Bolts And Nuts.The Panel Shall Have Provision To Accommodate The Following Switch Gears As Mentioned Below In Item No 18 And With The Required Front Area ( Approximate Front Area 2000 Mm X 1500 Mm ) And Depth Minimum 450 Mm. ( Drawings Will Be Approved Before Fabrication Of The Panel ) . 31 Providing And Fixing The Following Switch Gears, Metres, And Accessories On The Existing Cubicle Panel Board, Including Drilling Holes In The Panel, Making Connections, Testing And Commissioning, Etc. As Required. ( Panel No 01-Booster No 01 ) 32 400 Amps, Four Poles, Mccb, 50 Ka, With Microprocessor Base Overload And Short Circuit Protection Release, Ics = 100% Of Icu, And Withspreader Terminals. 33 Direct Rotary Handle ( Rhom ) For 400 A Mccb 34 3Ph Led Ammeter Cl -1 With Inbuilt Selector Switch For 3 Phases. Flush Mounting 96 X 96 Mm. 35 3Ph Led Voltmeter Cl 1 ( 0-500V ) With Inbuilt Selector Switch For 3 Phases. Flush Mounting 96 X 96 Mm. 36 Mcb Sp 6A, C-Curve 10Ka 37 Cts 400 / 5 A Amps, 15 Va With Class 1.0 Accuracy 38 Led Indicator Lamp, Red. 240 V Ac. 39 Led Indicator Lamp, Yellow. 240 V Ac. 40 Led Indicator, Lamp, Blue, 240V Ac. 41 Star Delta Starter ( As Per The Following Details For 50 Hp / 37 Kw, Three-Phase, 415 Volt Motor Pump Set ) 01 Nos 42 125 Amps , Tp, Mccb, 50 Ka Breaking Capacity With Spreaders Terminals. ( Dn1-160M L&T Or Similar Specification In Siemens / Abb / Schnider ) 43 Direct Rotary Handle ( Rhom ) For 125 A Mccb 44 3 Pole, 415 V, Power Contactor Ac3 Dutyrating95 A. 45 Overload Relay. Mn12 ( 28-46.5A ) Of L&Tor Similar Specification In Siemens / Abb / Schneider ) 46 Add-On Aux. Contact Block ( 1 No + 1 Nc ) For Star Delta Starter. 47 Cts 150 / 5 Amps, 5Va With Class 1.0 Accuracy 48 Single Phasing Preventer With U / V &O / V , 3 Ph, 415 V Ac. 49 Star Delta Timer. 50 Led Indicator Lamp, Red. 240 V Ac. 51 Led Indicator Lamp, Yellow. 240 V Ac. 52 Led Indicator, Lamp, Blue, 240V Ac. 53 3Ph Led Ammeter Cl 1 With Inbuilt Selector Switch For 3 Phases. 54 Push Button For Start ( Green ) 55 Contact Block No For Push Button 56 Push Button Forstop ( Red ) 57 Contact Block Nc For Push Button 58 Mcb Dp, 10Ka, 10 Amp For Control Circuit. 59 On, Off, Trip Indicating Lamps. 60 Auto-Manual Selector Switch. 61 Star Delta Starter ( As Per The Following Details For 30 Hp / 22 Kw, Three-Phase, 415 Volt Motor Pump Set ) 01 Nos 62 100 Amps , Tp, Mccb, 50 Ka Breaking Capacity With Spreaders Terminals. ( Dn0-100M L&T Or Similar Specification In Siemens / Abb / Schnider ) 63 Direct Rotary Handle ( Rhom ) For 100 A Mccb 64 3 Pole, 415 V, Power Contactor Ac3 Dutyrating80 A. 65 Overload Relay. Mn5 ( 20-33A ) Of L&Tor Similar Specification In Siemens / Abb / Schneider ) 66 Add-On Aux. Contact Block ( 1 No + 1 Nc ) For Star Delta Starter. 67 Cts 100 / 5 Amps, 5Va With Class 1.0 Accuracy 68 Single Phasing Preventer With U / V &O / V , 3 Ph, 415 V Ac. 69 Star Delta Timer. 70 Led Indicator Lamp, Red. 240 V Ac. 71 Led Indicator Lamp, Yellow. 240 V Ac. 72 Led Indicator, Lamp, Blue, 240V Ac. 73 3Ph Led Ammeter Cl 1 With Inbuilt Selector Switch For 3 Phases. 74 Push Button For Start ( Green ) 75 Contact Block No For Push Button 76 Push Button Forstop ( Red ) 77 Contact Block Nc For Push Button 78 Mcb Dp, 10Ka, 10 A For Control Circuit. 79 On, Off, Trip Indicating Lamps. 80 Auto-Manual Selector Switch. 81 40 Amps , Tp, Mccb, 50 Ka Breaking Capacity With Spreaders Terminals. ( Dn0-100M L&T Or Similar Specification In Siemens / Abb / Schnider ) 82 Direct Rotary Handle ( Rhom ) For 40 A Mccb 83 125 Amps , Tp, Mccb, 36 Ka Breaking Capacity , Ics = 100% Icu Withadjustable Overloadand Adjustable Short-Circuit Protectiondz1-160D 84 Direct Rotary Handle ( Rhom ) For 125 A Mccb 85 Panel No 02 ( Booster No 01 ) Fabrication, Supply, Installation, Testing, And Commissioning Of Electrical Control Panel Of Cubical Construction, Floor-Mounted Type, Fabricated Out Of A 2 Mm Thick Crca Sheet With Enclosure Protection Class Ip 42, Suitable For Operation On A 415-Volt, 3-Phase, 50 Hz, 4-Wire A.C. Supply System, Dust- And Vermin-Proof, Powder-Coated In An Approved Siemens Gray Shade After 7 Tank Pre-Treatment Processes. The Panel Shall Be Compartmentalized Type With Hinged Lockable Doors, Detachable Cable Gland Plates Made Of 3 Mm Thick Crca Sheet, Cable Alleys Of Suitable Size On Both Sides For Cabling Routing, Openable Type Rear Cover And Complete With 4 Strips Of Aluminium Bus Bars Of 400 Amps Capacity With Heat-Shrinkable Coloured Sleeves And Frp / Dmc / Smc Bus Bar Supports At Required Intervals, Control Terminals, And Suitable Sized Terminal Blocks For Incoming And Outgoing Cables, Including Providing And Fixing Interconnection From Busbars To Switch Gears And Up To Terminal Blocks With Suitable Sized Insulated Aluminium Conductor / Solid Aluminium Strip And Control Wiring With Suitable Sized Insulated Copper Conductor Cable, Including Suitable Size M.V. Danger Board Fixed On Panel. The Entire Panel Shall Have One Common Copper Bar Of Size 25 Mm X 5 Mm At The Rear With Two Earth Studs / Terminals. 86 The Panel Shall Be Supplied With A Bottom Base Ms Channel, Not Less Than 100 Mm X 50 Mm X 5 Mm Thick. Suitable Size Of M.V. Danger Boards Shall Be Fixed On Panel. The Panel Base Should Have Four 300 Mm Long Legs ( Made Of Angle Irons 50 X 50 X 6 Mm Or Other Suitable Means ) To Raise The Panel From The Floor, And A Removable 2 Mm Thick Powder-Coated Crca Sheet Cover Must Be Provided On Four Sides Of The Pedestal. The Base Frame Of The Panel Should Be Grouted Into The Floor With Four 12Mm Dia X 200Mm Long Bolts And Nuts.The Panel Shall Have Provision To Accommodate The Following Switch Gears As Mentioned Below In Item No 20 And With The Required Front Area ( Approximate Front Area 2000 Mm X 1200 Mm ) And Depth Minimum 450 Mm. ( Drawings Will Be Approved Before Fabrication Of The Panel ) . 87 Providing And Fixing The Following Switch Gears, Metres, And Accessories On The Existing Cubicle Panel Board, Including Drilling Holes In The Panel, Making Connections, Testing And Commissioning, Etc. As Required. ( Panel No 02-Booster No 01 ) 88 400 Amps, Four Poles, Mccb, 50 Ka, With Microprocessor Base Overload And Short Circuit Protection Release, Ics = 100% Of Icu, And Withspreader Terminals. 89 Direct Rotary Handle ( Rhom ) For 400 A Mccb 90 3Ph Led Ammeter Cl 1 With Inbuilt Selector Switch For 3 Phases. Flush Mounting 96 X 96 Mm. 91 3Ph Led Voltmeter Cl 1 ( 0-500V ) With Inbuilt Selector Switch For 3 Phases. Flush Mounting 96 X 96 Mm. 92 Cts 400 / 5 A Amps, 15 Va With Class 1.0 Accuracy 93 Led Indicator Lamp, Red. 240 V Ac. 94 Led Indicator Lamp, Yellow. 240 V Ac. 95 Led Indicator, Lamp, Blue, 240V Ac. 96 Mcb Sp 6A C-Curve 10Ka 97 Star Delta Starter ( As Per The Following Details For 30 Hp / 22 Kw, Three-Phase, 415 Volt Motor Pump Set ) 02 Nos 98 100 Amps , Tp, Mccb, 50 Ka Breaking Capacity With Spreaders Terminals. ( Dn0-100M L&T Or Similar Specification In Siemens / Abb / Schnider ) 99 Direct Rotary Handle ( Rhom ) For 100 A Mccb 100 3 Pole, 415 V, Power Contactor Ac3 Dutyrating80 A. 101 Overload Relay. Mn5 ( 20-33A ) Of L&Tor Similar Specification In Siemens / Abb / Schneider ) 102 Add-On Aux. Contact Block ( 1 No + 1 Nc ) For Star Delta Starter. 103 Cts 100 / 5 Amps, 5 Va With Class 1.0 Accuracy 104 Single Phasing Preventer With U / V &O / V , 3 Ph, 415 V Ac. 105 Star Delta Timer. 106 Led Indicator Lamp, Red. 240 V Ac. 107 Led Indicator Lamp, Yellow. 240 V Ac. 108 Led Indicator, Lamp, Blue, 240V Ac. 109 3Ph Led Ammeter Cl 1 With Inbuilt Selector Switch For 3 Phases. 110 Push Button For Start ( Green ) 111 Contact Block No For Push Button 112 Push Button Forstop ( Red ) 113 Contact Block Nc For Push Button 114 Mcb Dp, 10Ka, 10Afor Control Circuit. 115 On, Off, Trip Indicating Lamps. 116 Auto-Manual Selector Switch. 117 Mcb Dp, 10Ka, 40Amp For Control Circuit. 118 40 Amps , Tp, Mccb, 50 Ka Breaking Capacity With Spreaders Terminals. ( Dn0-100M L&T Or Similar Specification In Siemens / Abb / Schnider ) 119 Direct Rotary Handle ( Rhom ) For 40 A Mccb 120 125 Amps , Tp, Mccb, 36 Ka Breaking Capacity , Ics = 100% Icu Withadjustable Overloadand Adjustable Short-Circuit Protectiondz1-160D 121 Direct Rotary Handle ( Rhom ) For 125 A Mccb 122 ( Panel No 03 -Booster No Typeiv ) Fabrication, Supply, Installation, Testing, And Commissioning Of Electrical Control Panel Of Cubical Construction, Floor-Mounted Type, Fabricated Out Of A 2 Mm Thick Crca Sheet With Enclosure Protection Class Ip 42, Suitable For Operation On A 415-Volt, 3-Phase, 50 Hz, 4-Wire A.C. Supply System, Dust- And Vermin-Proof, Powder-Coated In An Approved Siemens Gray Shade After 7 Tank Pre-Treatment Processes. The Panel Shall Be Compartmentalized Type With Hinged Lockable Doors, Detachable Cable Gland Plates Made Of 3 Mm Thick Crca Sheet, Cable Alleys Of Suitable Size On Both Sides For Cabling Routing, Openable Type Rear Cover And Complete With 4 Strips Of Aluminium Bus Bars Of 400 Amps Capacity With Heat-Shrinkable Coloured Sleeves And Frp / Dmc / Smc Bus Bar Supports At Required Intervals, Control Terminals, And Suitable Sized Terminal Blocks For Incoming And Outgoing Cables, Including Providing And Fixing Interconnection From Busbars To Switch Gears And Up To Terminal Blocks With Suitable Sized Insulated Aluminium Conductor / Solid Aluminium Strip And Control Wiring With Suitable Sized Insulated Copper Conductor Cable, Including Suitable Size M.V. Danger Board Fixed On Panel. The Entire Panel Shall Have One Common Copper Bar Of Size 25 Mm X 5 Mm At The Rear With Two Earth Studs / Terminals. 123 The Panel Shall Be Supplied With A Bottom Base Ms Channel, Not Less Than 100 Mm X 50 Mm X 5 Mm Thick. Suitable Size Of M.V. Danger Boards Shall Be Fixed On Panel. The Panel Base Should Have Four 300 Mm Long Legs ( Made Of Angle Irons 50 X 50 X 6 Mm Or Other Suitable Means ) To Raise The Panel From The Floor, And A Removable 2 Mm Thick Powder-Coated Crca Sheet Cover Must Be Provided On Four Sides Of The Pedestal. The Base Frame Of The Panel Should Be Grouted Into The Floor With Four 12Mm Dia X 200Mm Long Bolts And Nuts.The Panel Shall Have Provision To Accommodate The Following Switch Gears As Mentioned Below In Item No 22 And With The Required Front Area ( Approximate Front Area 2000 Mm X 1200 Mm ) And Depth Minimum 450 Mm. ( Drawings Will Be Approved Before Fabrication Of The Panel ) . 124 Providing And Fixing The Following Switch Gears, Metres, And Accessories On The Existing Cubicle Panel Board, Including Drilling Holes In The Panel, Making Connections, Testing And Commissioning, Etc. As Required. ( Panel No 03 -Booster No Typeiv ) 125 400 Amps, Four Poles, Mccb, 50 Ka, With Microprocessor Base Overload And Short Circuit Protection Release, Ics = 100% Of Icu, And Withspreader Terminals. 126 Direct Rotary Handle ( Rhom ) For 400 A Mccb 127 3Ph Led Ammeter Cl 1 With Inbuilt Selector Switch For 3 Phases. Flush Mounting 96 X 96 Mm. 128 3Ph Led Voltmeter Cl 1 ( 0-500V ) With Inbuilt Selector Switch For 3 Phases. Flush Mounting 96 X 96 Mm. ( Single Function Meters. 129 Cts 400 / 5 A Amps, 15Va With Class 1.0 Accuracy 130 Led Indicator Lamp, Red. 240 V Ac. 131 Led Indicator Lamp, Yellow. 240 V Ac. 132 Led Indicator, Lamp, Blue, 240V Ac. 133 Mcb Sp 6A C-Curve 10Ka 134 Star Delta Starters ( As Per The Following Details For 25 Hp / 18.5 Kw, Three-Phase, 415 Volt Motor Pump Set ) 02 Nos 135 80 Amps , Tp, Mccb, 50 Ka Breaking Capacity , Ics = 100% Icu Withadjustable Overloadand Adjustable Short-Circuit Protection With Spreaders Terminals. ( Dn0-100M L&T Or Similar Specification In Siemens / Abb / Schnider ) 136 Direct Rotary Handle ( Rhom ) For 80 A Mccb 137 3 Pole, 415 V, Power Contactor Ac3 Dutyrating80 A. 138 Overload Relay. Mn5 ( 14-23A ) Of L&Tor Similar Specification In Siemens / Abb / Schneider ) 139 Add-On Aux. Contact Block ( 1 No + 1 Nc ) For Star Delta Starter. 140 Cts 100 / 5 Amps, 5 Va With Class 1.0 Accuracy 141 Single Phasing Preventer With U / V &O / V , 3 Ph, 415 V Ac. 142 Star Delta Timer. 143 Led Indicator Lamp, Red. 240 V Ac. 144 Led Indicator Lamp, Yellow. 240 V Ac. 145 Led Indicator, Lamp, Blue, 240V Ac. 146 3Ph Led Ammeter Cl 1 With Inbuilt Selector Switch For 3 Phases. 147 Push Button For Start ( Green ) 148 Contact Block No For Push Button 149 Push Button Forstop ( Red ) 150 Contact Block Nc For Push Button 151 Mcb Dp, 10Ka, 10 A For Control Circuit. 152 On, Off, Trip Indicating Lamps. 153 Auto-Manual Selector Switch. 154 Mcb Dp, 10Ka, 40 Amp For Control Circuit. 155 40 Amps , Tp, Mccb, 50 Ka Breaking Capacity With Spreaders Terminals. ( Dn0-100M L&T Or Similar Specification In Siemens / Abb / Schnider ) 156 Direct Rotary Handle ( Rhom ) For 40 A Mccb 157 125 Amps , Tp, Mccb, 36 Ka Breaking Capacity , Ics = 100% Icu Withadjustable Overloadand Adjustable Short-Circuit Protectiondz1-160D 158 Direct Rotary Handle ( Rhom ) For 125 A Mccb 159 Panel No 04 ( Type 2 Qtrs ) Fabrication, Supply, Installation, Testing, And Commissioning Of Electrical Control Panel Of Cubical Construction, Floor-Mounted Type, Fabricated Out Of A 2 Mm Thick Crca Sheet With Enclosure Protection Class Ip 42, Suitable For Operation On A 415-Volt, 3-Phase, 50 Hz, 4-Wire A.C. Supply System, Dust- And Vermin-Proof, Powder-Coated In An Approved Siemens Gray Shade After 7 Tank Pre-Treatment Processes. The Panel Shall Be Compartmentalized Type With Hinged Lockable Doors, Detachable Cable Gland Plates Made Of 3 Mm Thick Crca Sheet, Cable Alleys Of Suitable Size On Both Sides For Cabling Routing, Openable Type Rear Cover And Complete With 4 Strips Of Aluminium Bus Bars Of 400 Amps Capacity With Heat-Shrinkable Coloured Sleeves And Frp / Dmc / Smc Bus Bar Supports At Required Intervals, Control Terminals, And Suitable Sized Terminal Blocks For Incoming And Outgoing Cables, Including Providing And Fixing Interconnection From Busbars To Switch Gears And Up To Terminal Blocks With Suitable Sized Insulated Aluminium Conductor / Solid Aluminium Strip And Control Wiring With Suitable Sized Insulated Copper Conductor Cable, Including Suitable Size M.V. Danger Board Fixed On Panel. The Entire Panel Shall Have One Common Copper Bar Of Size 25 Mm X 5 Mm At The Rear With Two Earth Studs / Terminals. 160 The Panel Shall Be Supplied With A Bottom Base Ms Channel, Not Less Than 100 Mm X 50 Mm X 5 Mm Thick. Suitable Size Of M.V. Danger Boards Shall Be Fixed On Panel. The Panel Base Should Have Four 300 Mm Long Legs ( Made Of Angle Irons 50 X 50 X 6 Mm Or Other Suitable Means ) To Raise The Panel From The Floor, And A Removable 2 Mm Thick Powder-Coated Crca Sheet Cover Must Be Provided On Four Sides Of The Pedestal. The Base Frame Of The Panel Should Be Grouted Into The Floor With Four 12Mm Dia X 200Mm Long Bolts And Nuts.The Panel Shall Have Provision To Accommodate The Following Switch Gears As Mentioned Below In Item No 24 And With The Required Front Area ( Approximate Front Area 2000 Mm X 1200 Mm ) And Depth Minimum 450 Mm. ( Drawings Will Be Approved Before Fabrication Of The Panel ) . 161 Providing And Fixing The Following Switch Gears, Metres, And Accessories On The Existing Cubicle Panel Board, Including Drilling Holes In The Panel, Making Connections, Testing And Commissioning, Etc. As Required ( Panel No 04 -Type 2 Qtrs ) 162 250 Amps, Four Poles, Mccb, 50 Ka, With Microprocessor Base Overload And Short Circuit Protection Release, Ics = 100% Of Icu, And Withspreader Terminals. 163 Direct Rotary Handle ( Rhom ) For 250 A Mccb 164 3Ph Led Ammeter Cl 1 With Inbuilt Selector Switch For 3 Phases. Flush Mounting 96 X 96 Mm. 165 3Ph Led Voltmeter Cl 1 ( 0-500V ) With Inbuilt Selector Switch For 3 Phases. Flush Mounting 96 X 96 Mm. ( Single Function Meters. 166 Cts 250 / 5 A Amps, 10Va With Class 1.0 Accuracy 167 Led Indicator Lamp, Red. 240 V Ac. 168 Led Indicator Lamp, Yellow. 240 V Ac. 169 Led Indicator, Lamp, Blue, 240V Ac. 170 Mcb Sp 6A C-Curve 10Ka 171 Star Delta Starter ( As Per The Following Details For 15 Hp / 11 Kw, Three-Phase, 415 Volt Motor Pump Set ) 01 Nos 172 50 Amps , Tp, Mccb, 50 Ka Breaking Capacity , Ics = 100% Icu Withadjustable Overloadand Adjustable Short-Circuit Protection With Spreaders Terminals. ( Dn0-100M L&T Or Similar Specification In Siemens / Abb / Schnider ) 173 Direct Rotary Handle ( Rhom ) For 50 A Mccb 174 3 Pole, 415 V, Power Contactor Ac3 Dutyrating50 A. 175 Overload Relay. Mn5 ( 9-15A ) Of L&Tor Similar Specification In Siemens / Abb / Schneider ) 176 Add-On Aux. Contact Block ( 1 No + 1 Nc ) For Star Delta Starter. 177 Cts 50 / 5 Amps, 5Va 178 Single Phasing Preventer With U / V &O / V , 3 Ph, 415 V Ac. 179 Star Delta Timer. 180 Led Indicator Lamp, Red. 240 V Ac. 181 Led Indicator Lamp, Yellow. 240 V Ac. 182 Led Indicator, Lamp, Blue, 240V Ac. 183 3Ph Led Ammeter Cl 1 With Inbuilt Selector Switch For 3 Phases. 184 Push Button For Start ( Green ) 185 Contact Block No For Push Button 186 Push Button Forstop ( Red ) 187 Contact Block Nc For Push Button 188 Mcb Dp, 10Ka, 10A For Control Circuit. 189 On, Off, Trip Indicating Lamps. 190 Auto-Manual Selector Switch. 191 Star Delta Starter ( As Per The Following Details For 25 Hp / 18.5Kw, Three-Phase, 415 Volt Motor Pump Set ) 01 Nos 192 80 Amps , Tp, Mccb, 50 Ka Breaking Capacity , Ics = 100% Icu Withadjustable Overloadand Adjustable Short-Circuit Protection With Spreaders Terminals. ( Dn0-100M L&T Or Similar Specification In Siemens / Abb / Schnider ) 193 Direct Rotary Handle ( Rhom ) For 80 A Mccb 194 3 Pole, 415 V, Power Contactor Ac3 Dutyrating80 A. 195 Overload Relay. Mn5 ( 14-23A ) Of L&Tor Similar Specification In Siemens / Abb / Schneider ) 196 Add-On Aux. Contact Block ( 1 No + 1 Nc ) For Star Delta Starter. 197 Cts 100 / 5 Amps, 5 Va With Class 1.0 Accuracy 198 Single Phasing Preventer With U / V &O / V , 3 Ph, 415 V Ac. 199 Star Delta Timer. 200 Led Indicator Lamp, Red. 240 V Ac. 201 Led Indicator Lamp, Yellow. 240 V Ac. 202 Led Indicator, Lamp, Blue, 240V Ac. 203 3Ph Led Ammeter Cl 1 With Inbuilt Selector Switch For 3 Phases. 204 Push Button For Start ( Green ) 205 Contact Block No For Push Button 206 Push Button Forstop ( Red ) 207 Contact Block Nc For Push Button 208 Mcb Dp, 10Ka, 10 A For Control Circuit. 209 On, Off, Trip Indicating Lamps. 210 Auto-Manual Selector Switch. 211 Mcb Dp, 10Ka, 40 Amp For Control Circuit. 212 40 Amps , Tp, Mccb, 50 Ka Breaking Capacity With Spreaders Terminals. ( Dn0-100M L&T Or Similar Specification In Siemens / Abb / Schnider ) 213 Direct Rotary Handle ( Rhom ) For 40 A Mccb 214 125 Amps , Tp, Mccb, 36 Ka Breaking Capacity , Ics = 100% Icu Withadjustable Overloadand Adjustable Short-Circuit Protectiondz1-160D 215 Direct Rotary Handle ( Rhom ) For 125 A Mccb 216 Providing And Fixing 3 Ph Multifunction Meter For The Measurement Of Parameters Voltage, Current, Power Factor, Frequency, Kw And Kwhflush Mounting In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections And Testing, Etc. As Required. 217 Providing And Fixingadd-On Aux. Contact Block ( 2 No + 2 Nc ) ) Forpower Contactorin Existing Cubicle Panel Board Including Making Connections, Etc. As Required. 218 Providing And Fixing 400 Amps , 4 Pole, 415 V, Category Ac-23A. On Load Change Over Switch, In Open Execution In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required. 219 Credit For Existing Panel.Disconnection Of Existing Motor Control Panels Installed At The Following Places From Their Foundation And Disconnection Of Incoming And Outgoing Connections And Credit For The Panels.I ) Booster No 01 -2 Nos Panel.Ii ) Booster No Type Iv -1 No Panelii ) Booster Near Type 2 -1 No Panel 220 Add 1.0633 Multiplying Factor For Gst On Dsr

Key Value

Document Fees
Refer document
EMD
INR 122959.0 /-
Tender Value
INR 61.47 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail