Tender For Repair To Fencing, Boundary Wall Of Otm Accommodaiton In The Aor Of Age B / R-I Under Ge Hisar Mil Station.; 1 Dismantling Galvanized Steel Barbed Wire Of Any Description Fixed To Any Type Of Fencing Posts.Note :- Each Line Of Horizontal / Vertical / Diagonal Wire To Be Measured For The Purpose Of Payment. 2 Dismantling Posts Or Struts ( Wood, Steel Or R.C.C. ) Any Section, Including Taking Out Embedded Portion Embedded In Concrete, Brick Work, Masonry Etc. And Making Good Disturbed Ground All As Directed. 3 Excavating In Post Holes ( Or Similar Holes ) Each Not Exc 0.50 Cum, Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers N.Exc 25Cm, Watering, And Removing Surplus Soil To A Distance N.Exc 50 M And Making Good Surface In Soft / Loose Soil. 4 S&F Mild Steel Work Such As Angle Iron In Posts & Struts In Fencing Including Cutting Tops To Shape As Directed, Drilling Holes, Notching For Wire Etc., Flat Iron Fillets ( For Securing Wire Mesh Etc ) Including Necessary Welding Where Required As Per Site Requirement And Other Similar Works Complete, Conforming To Gde E-165 ( Fe 290 ) . 5 S&F Ms Holdfast, Fi, Hook And Pintle Hinges, Large Hasp And Staples, Clamps, Hooks For Hanging Fans And Similar Small Articles Conforming To Grade E-165 ( Fe 290 ) Including Necessary Welding Etc. And Fixed In Position. 6 S&F Mild Steel Screw Bolts ( Machine Made ) With Hexagonal Or Square Heads At One End And Screwed The Other, Or Screwed Both Ends, Each Screwed End To Be Fitted With Washers And One Hexagonal Or Square Nut, Exc 5 Cm Bot Not Exc 10Cm Long And Dia Of Neck Not Less Than 10Mm Complete All As Specified. 7 Supply And Fixing Mild Steel Galvanized Chain Link Fencing Any Size Or Type As Directed Complete All As Specified.Note:-1. Weight Per Kg Of Chain Link Fencingshallbe Ascertained By Convening Boo Orderedby Accepting Officer, 2. Flat Iron, Round Bars, Nut Bolts And Washer Shall Be Measured And Paid For Separately Under Respective Items. 8 S&F Mild Steel Round Bars As In Tie Bars Fixed To Fencing Posts Including Cut To Length, Bent To Shape, Welding Of Bar At Spots As Directed And Other Similar Works, Conforming To Grade E-165 ( Fe 290 ) , Complete, All As Specified & Directed. 9 M&L Pcc 1:3:6 Type C2 Using 40 Mm Graded Stone Aggregate In Foundations, Filling And Mass Concrete. 10 M&L For Preparation Of New Steel And Iron Surfaces Of Any Description Over 10 Cm In Width Or Girth And Applying Two Coats Of Synthetic Enamelpaint Of Approved Tint Over A Coat Of Zinc Chrome Primer Complete All As Specified And Directed. 11 Demolition Of Brick / Stone Masonry Built In Cement / Lime Mortar Of Any Mix And Stacking Serviceable Stones Aside For Reuse & Removing Unserviceable Materials In Low Laying Area, Complete, All As Directed. 12 Taking Down Cement Plaster Or Cement Lime Plaster On Pcc / Stone Surface / Brick Surfaces Including Raking Out Joints Hacking For Key Scrubbing Down With Water Etc All As Directed. 13 Demolition Of Cement Concrete ( Un-Reinforced ) In Ground Floor And Paving Not Exc 15 Cm Thickness ( Below Or Above Ground Level ) Complete, All As Directed. 14 M&L For Brick Work With Old Size Sub-Class ‘B’ Bricks, Straight Or Curved On Plan Exc 6.00 Metre Mean Radius, Built In Cement Mortar 1:6 Complete All As Specified. 15 All As Per Serial Item No 14.00 Here-In-Before But Except Bricks.Note : Old Serviceable Bricks Retrieved From Serial Item No. 11.00 Here-In-Before Shall Be Used Under This Item. 16 M & L For Rendering 15Mm Thick In Cement Mortar 1:4 On Faces Of Brick Work Or Concrete Surfaces Of Walls, Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. 17 M&L For Rough Cast Finish Plaster By Applying The Under Coat Of Cement And Sand Mortar 1:3 Not Less Than 10 Mm Thick And While It Is Still In Plastic State The Roughcast Mixture Consisting Of Crushed Stone Or Fine Gravel Aggregate ( Size Between 6 To 12 Mm Depending On The Texture Required ) Mixed With Coarse Sand And Cement In The Ratio Of 1: 1: 1 Shall Be Applied And Finished Even Complete . 18 M&L For Preparation Of Newly Plastered Surfaces Of Wall & Applying Two Coats Of Cement Base Paint Of Approved Shade / Tint On Walls Over A Coat Of Primer All As Specified & As Directed. 19 Dismantling Of Wrought Iron Or Mild Steel Work Of Any Description Not Otherwise Provided For In This Schedule All As Specified & Directed. 20 S&F Mild Steel Framed Work As In Steel Frames, Chowkats, Doors Or Gates Of Angle Or Other Section With Gusset Plates, Rails, Braces, Etc., Complete, Drilled For Fixing Of Steel Sheeting Or Other Covering, Doors Etc. To Be Prepared For Hanging Or Sliding With And Including Either Hooks And Hinges Or Steel Hanging Door Fittings ( Exclusive Of Steel Sheeting Or Other Covering, Running Rails And Guides ) And Hanging, Also Fastening And Fixing, Conforming To Grade E-165 ( Fe 290 ) , Complete, All As Specified & Directed. 21 M&L For 75Mm Thick Pcc ( 1:4:8 ) Type D2 Using 40 Mm Graded Crushed Stone Aggregate As Insub Base, Surface Finished Fair And Evencomplete All As Specified. 22 M&L For Factory Made Hard Wearing Coloured Ceramic Tiles 300X300x10mm In Size Or Nearest Higher Size Laid As In Floor Etc, Set And Jointed In Neat Cment Slurry & Pointing In White Or Colured Cementto Match With The Shade Of Tiles Over & Including 20Mm Thick Screed Bed In Cement & Sand Mortar 1:6, Complete, All As Specified & As Directed.Make :- Vc Shield Series Of Somany Or Equivalent Of Make Mentoned In Appx C Here-In-After 23 M & L For Preparing Oldbrick, Stone, Asbestos Cement Or Plastered Surfaces, Concretesurfaces ( Kerb Stone Painting ) Of Any Description Over 10Cm Width Or Girth And Applying One Coats Of Synthetic Enamel Paint Of Any Tint Etc Complete All As Specified And As Directed.