| 1 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required.Group B |
| 2 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module |
| 3 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 4 | 5 amps switch |
| 5 | 5 amps socket |
| 6 | 15 amps switch |
| 7 | 15amps socket |
| 8 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 9 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required |
| 10 | 1 x 1.5 sq.mm |
| 11 | 2 x 2.5 sq.mm |
| 12 | 2 x 4 sq.mm |
| 13 | 2 x 6 sq.mm |
| 14 | Supplying and fixing of following sizes of Heavy duty PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 15 | Supplying and fixing suitable size G.I. box with modular plate and cover in front or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB \"C\" curve including connections, painting etc. as required. |
| 16 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 X 16 sq. mm + 2 X 16 sq. mm earth wire |
| 17 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 18 | Single pole |
| 19 | Single pole neutal |
| 20 | S/F of single box type fitting complete with all accessories i/c makingconnection etc. as required. TMC 5011XT- LED 22W P3241i/c having 1 Nos. of stellar 20watts LED tubelight in the existing fitting as required. (Philips make) |
| 21 | S/F of double box type fitting complete with all accessories i/c makingconnection etc. as required. TMC 5022XT- LED 22W P3242i/c having 2 Nos. of stellar bright 20 watts LED tubelight in the existing fitting as required. (Philips make) |
| 22 | S/F of T-5 LED 13 watts tube with suitable driver i/c making connection as required. Philips make |
| 23 | Repairing the bollard light fittings by replacing the top cover and rusted base plate i/c painting the same with two or more coat as per site requirement |
| 24 | S/F of 9 watts LED bulb in the existing fittign with suitable brass holder i/c making connection as required. |
| 25 | Repairing the ceiling fan by replacing the defective copper winding ball bearing, bushes etc. as required at site |
| 26 | S/F of 1400 mm dia. High speed ceiling fan with suitable down rod with double ball bearing and copper winding i/c making connection as required. |
| 27 | S/F of 25 amps plug top i/c making connection as required. North -west make |
| 28 | Servicing the panel with air blower i/c rubbing the corrosion and painting the same with two or more coat i/c dressign the cables/ wires, replacement of burnt thimbles, testing all the nut bolt and connection etc. as required at site. |
| 29 | S/F of snap-on DLP trunking of 105 mm X 50 mm with suitable cover on the existing wall/ surface i/c having all the accessories such as Flat angle, end caps, internal/ external angle etc. as required at site. |
| 30 | S/I/T/C of 20 watts tube (stellar bright) of LED tube 2100 lumen, 6500k suitable for existingfitting i/c making connection as required. |
| 31 | Supplying, fixing and laying of one number PVC insulated and PVC sheathed/ XLPE aluminium armoured conductor power cable confirming to 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering, refilling the same etc. as required. 4x16 sqmm (for the repairing of street light fittings) |
| 32 | Supplying and fixing of street light pole box of size 8\"x10\" complete with all accessories i/c suitable clamps, suitable bakelite sheet, brass screws, washers and 1 Nos. SP MCB 10 amps capacity i/c making connection etc. as required at site. |
| 33 | Supplying/ installation/ testing and commissioning of 200 watts flood light LED fitting having suitable angle frame, complete with all accessories i/c having pressure dia cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening seperate driver compartment with IP66 protection and Impact resistance of IK07 with KV Build In SPD i/c making connection as required. (Philips make) |
| 34 | Dismantling the existing accessories and depositing the same at Engineering Store. |