}

Tender For Supply And Complete Installation Of Smart Grid Directional Sensors Sets (With All Required Accessories And Parts), Computers, Battery With Charger, Ht And Lt Fault Locator Machine (Van Mounted) Under The Jurisdiction Of Se, Eudc, Mathura, mathura-Uttar Pradesh

Government Departments has published Tender For Supply And Complete Installation Of Smart Grid Directional Sensors Sets (With All Required Accessories And Parts), Computers, Battery With Charger, Ht And Lt Fault Locator Machine (Van Mounted) Under The Jurisdiction Of Se, Eudc, Mathura. Submission Date for this Tender is 28-11-2023. Measuring wheels Tenders in mathura Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

40716367
Tender For Supply And Complete Installation Of Smart Grid Directional Sensors Sets (With All Required Accessories And Parts), Computers, Battery With Charger, Ht And Lt Fault Locator Machine (Van Mounted) Under The Jurisdiction Of Se, Eudc, Mathura
Open Tender
Indian
Uttar Pradesh
Mathura
28-11-2023

Tender Details

Supply And Complete Installation Of Smart Grid Directional Sensors Sets ( With All Required Accessories And Parts ) , Computers, Battery With Charger, Ht And Lt Fault Locator Machine ( Van Mounted ) Under The Jurisdiction Of Se, Eudc, Mathura , Providing & Complete Work Of Installation Of Smart Grid Bi-Directional Sensors Sets As Per Following Specifications :- , Supply Of Smart Grid Bi-Directional Sensors Sets For 3 Nos. 33 Kv Lines ( 20 Km, 16 Km And 20 Km ) 3 Nos. Of 11 Kv Line ( 08 Km, 07 Km And 07 Km ) With Due Warranty Period. 3 Year Amc ( Cost Of Maintenance & Replacement Of Damaged Items Are Liable To Be Covered For Amc Period ) Shall Be Started Immediately After Completion Of Due Warranty Period. A. Supply Of 26 Set Of Grid Sensors Supporting Cellular Network ( Fault Passing Indicator ) , Dcu, Rtu, ( 26 Set ) B. Metryview / Any Other Supporting Software-Core A Mandatory Core-Software And Firmware, Server Computer C. Deployement Of Sensors. D. Support And Services Technical Support Includes: • Supporting The Choosing The Location Of Installation • Supporting The Choosing Optimal Configuration Including Thresholds Etc. • Supporting The Installation From Remote • Configuring The Servers Client Setup And Parameters • Configuring The Server’S Map ( Including A Kmz File If Available ) • Preparing A Simplified Schematic Diagram ( For A Single Set It Includes Only The Line With No Branches ) • Supporting Any Problem Or Question ( Communication, Electrical, Etc. ) , Providing & Complete Work Of Installation Of Computer System With 01 Year Guarntee Period A. Processor ( I-5 12Th Gen. / Ryzen 7, 12 Core 2.5 Ghz Or Higher ) With Supporiting Motherboard. B. Ram- 16 Gb Ddr-4 C. Ssd - 256 Gb & Hard Drive- 01 Tb E. Wifi 6 E F. 24 Inch. Led Display Monitor. G. Multi Function Monochrome Laser Printer Wiht Wi-Fi, Network Auto Duplex Printing Print Speed Utp 30Ppn With Print Resulation 2400X600 Dpi With Scanning. Wifi, Keyboard And 1.1 Kva Ups. , Providing & Complete Work Of Installation Of 24 Volt Battery With Battery Charger Along With Due Guarantee Period , Providing Of Van Mounted Ht Cable Fault Locator :- , Van Mounted Ht Cable Fault Locator With Following Features Along With Due Warranty Period 3 Year Amc ( Cost Of Maintenance & Replacement Of Damaged Items Are Liable To Be Covered For Amc Period ) Shall Be Started Immediately After Completion Of Due Warranty Period. Fully Automatic Live Monitoring And Indication For All Safety Circuit Dc Hipotupto 40 Kv, Fault Conversion ( Burn ) Upto 40Kv With Max Current 350Ma Surge Generator With Surge Voltage 4 / 8 / 16 / 32 Kv Surge Energy 4Kv / 1100J Upto 1500 J Built-In Ir Testing 10 Kv And Above Tdr Pre- Locator With Bipolar Voltage Upto 90 Volt Built-In Arm Multishot More Than 20 Graph In Single Shot With Sampling Rate 400Mhz And More Built-In Ice Method And Voltage Decay Method Facility Optionfor Upgradingvlf And Pd In Future Cable Route Tracer With User Selectable More Than 20 Frequencies Cable Identification Set Generator Set 5Kva Surge Wave Receiver 50 M Cable Set Other Accessories To Be Included : I ) Ac / Dc True Rms Multimeter With 20 A, 1000Vac / Dc And Non Contact Voltage Detection. Ii ) Discharge Rods Iii ) Hand Gloves Iv ) Tool Kit V ) Generator, Of Suitable Capacity, Based On Petrol Engine. Vi ) Digital Portable Thermal Imaging Camera. Vii ) Clamp On Erath Resistance Tester. Viii ) Roto Meter Ix ) Lt Cable For Suitable Size. ( Hv Cable Or Protective Earth Cable, Power Cable 50Mtr. Each With Suitable Clamp ) X ) Auxillary Cable 15 Mtr. , Providing Of Van Mounted Lt Cable Fault Locator :- , Automatic Van Mounted Portable Cable Fault Locating System For Low Voltage Cables With Due Warranty Period :- 3 Year Amc ( Cost Of Maintenance & Replacement Of Damaged Items Are Liable To Be Covered For Amc Period ) Shall Be Started Immediately After Completion Of Due Warranty Period. 1. Cable Fault Locating System Supply Must Comprise Of: A ) 1.5 & 3 Kv Dual Stage Portable Fault Finding System With Integrated Tdr, 1 Nos. ( I ) The System Must Have Arc Reflection Capability ( Arm ) Mode. ( Ii ) The Unit Should Operate On Ac Power Supply 230Vand Should Also Run Based On12 / 24 V Internal Batteries ( Internal Batteries Should Be Provided As Standard ) Built Into The System To Allow Portable Use. ( Iii ) Equipment Should Provide The Following Features : A.Automatic Fault Locating Procedure. B.Expert Mode To Guide The User Where The Users May Not Operate The Unit On A Regular Basis, Through The Gui. C. Automatic End Of Cable And Distance To Fault Location D. Automatic Breakdown Detection. 2.Surge Wave Receiver / Cable Fault Poinpointer, 1 Nos. 3.Accessories To Be Included : A.20A Ac / Dc True Rms Multimeter , With Built In Non Contact Voltage Function, 1000V Ac / Dc , Resistance 60Mohms, Digital Display With Bargraph And Temperature Measurement Upto 1000Deg. B.Digital Measuring Wheel C. Pair Hand Gloves D. Discharge Rod, Earth Rod, Cables And Clamps. E. Dual Stage Portable Fault Finding System. F.Digital Earth Resistance Meter. G. Digital Portable Thermal Imaging Camera. H. Clamp On Erath Resistance Tester. I.Roto Meter J.Htcable For Suitable Size. ( Hv Cable Or Protective Earth Cable, Power Cable 50Mtr. Each With Suitable Clamp ) K. Auxillary Cable 15 Mtr.

Key Value

Document Fees
INR 5000 /-
EMD
INR 600000.0 /-
Tender Value
INR 5.16 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail