Instrumentation Thermocouple And Earthing Cables Lot 1 Instrumentation Thermocouple And Earthing Cables Lot 1 For Numaligarh Refinery Expansion Project , Lot 1 - Flame Retardant Armoured Signal Cables - Is Cable For Instrument, Annealed Bare Copper, Xlpe Insulation, Al-Mylar Collective Shielded With Atc Drain Wire, Flame Retardant Low Smoke, St2 Pvc Sheathed, Galvanised Steel Wire Flat Armoured, Intrinsic Safeas Per Mr. Note:The Quantity Given Under Column G Is Sum Of Quantity Of Cables As Per Mr And Mandatory Spares Cables As Pertp-1Zzza-Pq-Prc-0005 Nrl Msl Category : 6.210 Instrument Signal Cable , 12Px2.5 Is Blue Flame Retd. Ls Pvc Arm Ovl Shld Cable Code :E5-0.6/1.1-Ttcoco(C)-2.5(12P)Ib Cable Type:Type S31 , 1Px2.5 Is Blue Flame Retd. Ls Pvc Arm Ovl Shld Cable Code: E5-0.6/1.1-Ttcoco(C)-2.5(1P)Ib Cable Type:Type S3 , 6Px2.5 Is Blue Flame Retd. Ls Pvc Arm Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(C)-2.5(6P)Ib Cable Type:Type S21 , 1Px4 Is Blue Flame Retd. Ls Pvc Arm Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(C)-4(1P)Ib Cable Type:Types85 , 2Px4 Is Blue Flame Retd. Ls Pvc Arm Ind+Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(I/C)-4(2P)Ib Cable Type:Type S86 , 6Px1.5 Is Blue Flame Retd. Ls Pvc Arm Ind+Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(I/C)-1.5(6P)Ib Cable Type:Type S17 , 12Px2.5 Is Blue Flame Retd. Ls Pvc Arm Ind+Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(I/C)-2.5(12P)Ib Cable Type:Type S93 , 2Px2.5 Is Blue Flame Retd. Ls Pvc Arm Ind+Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(I/C)-2.5(2P)Ib Cable Tpe:Type S96 , 6Px2.5 Is Blue Flame Retd. Ls Pvc Arm Ind+Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(I/C)-2.5(6P)Ib Cable Type:Type S97 , 1Px1.5 Is Blue Flame Retd. Ls Pvc Arm Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(C)-1.5(1P)Ib Cable Type:Type S1 , 12Px1.5 Is Blue Flame Retd. Ls Pvc Arm Ind+Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(I/C)-1.5(12P)Ib Cable Type:Type S27 , Lot-2 - Flame Retardant Armoured Signal Cables - Nis Cable For Instrument, Annealed Bare Copper, Xlpe Insulation, Al-Mylar Collective Shielded With Atc Drain Wire, Flame Retardant Low Smoke, St2 Pvc Sheathed, Galvanised Steel Wire Flat Armoured, Non-Intrinsic Safe As Per Mr. Note:The Quantity Given Under Column G Is Sum Of Quantity Of Cables As Per Mr And Mandatory Spares Cables As Pertp-1Zzza-Pq-Prc-0005 Nrl Msl Category - 6.210 Instrument Signal Cable , 1Px2.5 Nis Black Flame Retd. Ls Pvc Arm Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(C)-2.5(1P)Nk Cable Type:Type S4 , 2Px1.5 Nis Black Flame Retd. Ls Pvc Arm Ind+Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(I/C)-1.5(2P)Nk Cable Type:Type S11 , 6Px1.5 Nis Black Flame Retd. Ls Pvc Arm Ind+Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(I/C)-1.5(6P)Nk Cable Type:Type S18 , 12Px2.5 Nis Black Flame Retd. Ls Pvc Arm Ind+Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(I/C)-2.5(12P)Nk Cable Type:Type S30 , 2Px2.5 Nis Black Flame Retd. Ls Pvc Arm Ind+Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(I/C)-2.5(2P)Nk Cable Type:Type S14 , 6Px2.5 Nis Black Flame Retd. Ls Pvc Arm Ind+Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(I/C)-2.5(6P)Nk Cable Type:Type S20 , 8Tx2.5 Nis Black Flame Retd. Ls Pvc Arm Ind+Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(I/C)-2.5(8T)Nk Cable Type:Type S95 , 1Px1.5 Nis Black Flame Retd. Ls Pvc Arm Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(C)-1.5(1P)Nk Cable Type:Type S2 , 12Px1.5 Nis Black Flame Retd. Ls Pvc Arm Ind+Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(I/C)-1.5(12P)Nk Cable Type:Type S28 , Lot-3 - Fire Resistant Armoured Signal Cables - Is Cable For Instrument, Annealed Bare Copper, Xlpe Insulation, Al-Mylar Collective Shielded With Atc Drain Wire, Fire Resistant Low Smoke Zero Halogen, St2 Pvc Sheathed, Galvanised Steel Wire Flat Armoured, Intrinsic Safe As Per Mr. Note:The Quantity Given Under Column G Is Sum Of Quantity Of Cables As Per Mr And Mandatory Spares Cables As Pertp-1Zzza-Pq-Prc-0005 Nrl Msl Category - 6.212 Signal Cable- Fire Resistent , 1Px1.5 Is Red+Blue Strip Fire Rest. Lszh Arm Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(C)-1.5(1P)Irb Cable Type:Type S43 , 12Px2.5 Is Red+Blue Strip Fire Rest. Lszh Arm Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(C)-2.5(12P)Irb Cable Type:Type S71 , 1Px2.5 Is Red+Blue Strip Fire Rest. Lszh Arm Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(C)-2.5(1P)Irb Cable Type:Type S45 , 6Px2.5 Is Red+Blue Strip Fire Rest. Lszh Arm Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(C)-2.5(6P)Irb Cable Type:Types61 , 12Px1.5 Is Red+Blue Strip Fire Rest. Lszh Arm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(I/C)-1.5(12P)Irb Cable Type:Type S67 , 6Px1.5 Is Red+Blue Strip Fire Rest. Lszh Arm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(I/C)-1.5(6P)Irb Cable Type:Type S57 , 12Px2.5 Is Red+Blue Strip Fire Rest. Lszh Arm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(I/C)-2.5(12P)Irb Cable Type:Type S94 , 2Px2.5 Is Red+Blue Strip Fire Rest. Lszh Arm Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(C)-2.5(2P)Irb Cable Type:Type S55 , Lot-4 - Fire Resistant Unarmoured Signal Cables - Is Cable For Instrument, Annealed Bare Copper, Xlpe Insulation, Al-Mylar Collective Shielded With Atc Drain Wire, Fire Resistant Low Smoke Zero Halogen, St2 Pvc Sheathed, Unarmoured, Intrinsic Safe As Per Mr. Note:The Quantity Given Under Column G Is Sum Of Quantity Of Cables As Per Mr And Mandatory Spares Cables As Pertp-1Zzza-Pq-Prc-0005 Nrl Msl Category - 6.212 Signal Cable- Fire Resistent , 1Px1.5 Is Red+Blue Strip Fire Rest. Lszh Uarm Ovl Shld Cable Code:E4-0.6/1.1-Ttcxx(C)-1.5(1P)Irb Cable Type: Type S80 , Lot-5 - Fire Resistant Armoured Signal Cables - Nis Cable For Instrument, Annealed Bare Copper, Xlpe Insulation, Al-Mylar Collective Shielded With Atc Drain Wire, Fire Resistant Low Smoke Zero Halogen, St2 Pvc Sheathed, Galvanised Steel Wire Flat Armoured, Non Intrinsic Safeas Per Mr. Note:The Quantity Given Under Column G Is Sum Of Quantity Of Cables As Per Mr And Mandatory Spares Cables As Per Tp-1Zzza-Pq-Prc-0005 Nrl Msl Category - 6.212 Signal Cable- Fire Resistent , 1Px1.5 Nis Red Fire Rest. Lszh Arm Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(C)-1.5(1P)Nr Cable Type: Type S44 , 1Tx1.5 Nis Red Fire Rest. Lszh Arm Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(C)-1.5(1T)Nr Cable Type: Type S48 , 1Px2.5 Nis Red Fire Rest. Lszh Arm Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(C)-2.5(1P)Nr Cable Type:Type S46 , 1Tx2.5 Nis Red Fire Rest. Lszh Arm Ovl Shld Cable Code: E4-0.6/1.1-Ttcxcx(C)-2.5(1T)Nr Cable Type:Type S91 , 1Px4 Nis Red Fire Rest. Lszh Arm Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(C)-4(1P)Nr Cable Type:Type S87 , 12Px1.5 Nis Red Fire Rest. Lszh Arm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(I/C)-1.5(12P)Nr Cable Type:Type S68 , 2Px1.5 Nis Red Fire Rest. Lszh Arm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(I/C)-1.5(2P)Nr Cable Type:Type S52 , 6Px1.5 Nis Red Fire Rest. Lszh Arm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(I/C)-1.5(6P)Nr Cable Type:Type S58 , 6Tx1.5 Nis Red Fire Rest. Lszh Arm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(I/C)-1.5(6T)Nr Cable Type:Type S64 , 8Tx1.5 Nis Red Fire Rest. Lszh Arm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(I/C)-1.5(8T)Nr Cable Type:Type S74 , 12Px2.5 Nis Red Fire Rest. Lszh Arm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(I/C)-2.5(12P)Nr Cable Type: Type S70 , 6Px2.5 Nis Red Fire Rest. Lszh Arm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(I/C)-2.5(6P)Nr Cable Type:Type S60 , 6Tx2.5 Nis Red Fire Rest. Lszh Arm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(I/C)-2.5(6T)Nr Cable Type:Type S98 , 12Px4 Nis Red Fire Rest. Lszh Arm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(I/C)-4(12P)Nr Cable Type:Type S90 , 8Tx2.5 Nis Red Fire Rest. Lszh Arm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(I/C)-2.5(8T)Nr Cable Type:Type S99 , Lot-6 - Fire Resistant Unarmoured Signal Cables – Nis Cable For Instrument, Annealed Bare Copper, Xlpe Insulation, Al-Mylar Collective Shielded With Atc Drain Wire, Fire Resistant Low Smoke Zero Halogen, St2 Pvc Sheathed, Unarmoured, Non Intrinsic Safeas Per Mr. Note:The Quantity Given Under Column G Is Sum Of Quantity Of Cables As Per Mr And Mandatory Spares Cables As Pertp-1Zzza-Pq-Prc-0005 Nrl Msl Category - 6.212 Signal Cable- Fire Resistent , 1Px1.5 Nis Red Fire Rest. Lszh Uarm Ovl Shld Cable Code:E4-0.6/1.1-Ttcxx(C)-1.5(1P)Nr Cable Type:Type S81 , 1Px2.5 Nis Red Fire Rest. Lszh Uarm Ovl Shld Cable Code:E4-0.6/1.1-Ttcxx(C)-2.5(1P)Nr Cable Type:Type S82 , 12Px1.5 Nis Red Fire Rest. Lszh Uarm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxx(I/C)-1.5(12P)Nr Cable Type:Type S83 , 2Px1.5 Nis Red Fire Rest. Lszh Uarm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxx(I/C)-1.5(2P)Nr Cable Type: Type S84 , 6Px1.5 Nis Red Fire Rest. Lszh Uarm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxx(I/C)-1.5(6P)Nr Cable Type:Type S79 , Lot-7 - Flame Retardant Thermocuple Cable (K-Type) Cable For Instrument, Annealed Bare Copper, Xlpe Insulation, Al-Mylar Collective Shielded With Atc Drain Wire, Flame Retardant Low Smoke Low Halogen, St2 Pvc Sheathed, Galvanised Steel Wire Flat Armoured As Per Mr. Note:The Quantity Given Under Column G Is Sum Of Quantity Of Cables As Per Mr And Mandatory Spares Cables As Pertp-1Zzza-Pq-Prc-0005 Nrl Msl Category - 6.213 - Instrument Thermocouple Cable , 1Px16awg Yellow Flame Retd. Ls Pvc Arm Ovl Shld T/C-K Cable Code:X4-0.6/1.1-Ttcoco(C)-16(1P)Y Cable Type: Type S37 , Lot-8 - Flame Retardant Earthing Cable Cable For Instrument, Annealed Bare Copper, Xlpe Insulation, Al-Mylar Collective Shielded With Atc Drain Wire, Flame Retardant Low Smoke Low Halogen, St2 Pvc Sheathed, Unarmouredas Per Mr. Note:The Quantity Given Under Column G Is Sum Of Quantity Of Cables As Per Mr And Mandatory Spares Cables As Pertp-1Zzza-Pq-Prc-0005 Nrl Msl Category - 6.210 Instrument Signal Cable , 1Cx6 Green+Blue Strip Flame Retd. Ls Pvc Unarm Cable Code:E5-0.6/1.1-Sc-6(1C)Gb Cable Type:Type E1 , 1Cx6 Green+ Yellow Strip Flame Retd. Ls Pvc Unarm Cable Code:E5-0.6/1.1-Sc-6(1C)Gy Cable Type:Type E2 , 1Cx6 Green Flame Retd. Ls Pvc Unarm Cable Code:E5-0.6/1.1-Sc-6(1C)G Cable Type:Type E3 , 1Cx2.5 Green+ Yellow+ Green Strip Flame Retd. Ls Pvc Unarm Cable Code:E5-0.6/1.1-Sc-2.5(1C)Gyg Cable Type:Type E6 , 1Cx10 Green+ Yellow +Green Strip Flame Retd. Ls Pvc Unarm Cable Code:E5-0.6/1.1-Sc-10(1C)Gyg Cable Type:Type E7 => Limited